ALDEN AT WESTMOOR, THE

1122 BRIDGEFIELD PL, Charlotte, NC 28216
Seasonal Swimming Pool · NC permit/State ID 2060501621
Latest result8 demerits
Last inspectedMay 21, 2026
Inspections on record4
On record sinceJul 26, 2024

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

01224 Jul 26, 2024: 22Aug 14, 2024: 24May 23, 2025: 0May 21, 2026: 8
Jul 26, 2024Lower is betterMay 21, 2026

Inspections & violations

May 21, 2026 8 demerits · 2 violations
Inspector comments: PERSON OF CONTACT FOR POOL IS TERENCE CHRUCH CPO IS DALE RAMIERZ C-155454 CPO required to visiting swimming pool daily. Flow meter must remain operable to ensure pool is maintaining proper turn over rate. Flow must be maintained at 77 to 140 GPM
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. One skimmer had trash and debris. Keep skimmers free of debris
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter not operating at time of inspection .2518(g) Keep flow meter operational.

View this inspection on the county portal ›

May 23, 2025 0 demerits · 0 violations
Inspector comments: Permit Restriction: Flow meter must remain operable. Flow required at 77 gpm to 140 gpm to meet turnover and flow restriction of the filter. Flow verified at 105

No violations were recorded for this inspection.

View this inspection on the county portal ›

Aug 14, 2024 24 demerits · 6 violations
Inspector comments: Pool is to remain closed until a passing return visit has been completed by the health department. Contact Chris Sells 704 576 8678 for return visit.
#2 · Water quality: disinfectant residual provided by −6
Observed cl below 1ppm. Immediate suspension issued. .2535(4) Maintain chlorine at least 1.0 ppm.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Observed no records since July. .2535 (11) The pool operator shall inspect the pool at least daily and maintain written records. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed debris on pool floor around ladder. .2537(14) Keep pool surface and pool floor free of debris.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
Observed ring missing around floor feature fitting. Replace .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair.
#18 · Premises: lifeguards present or warning signs posted −4
Observed signs with adults should not swim alone, and children should not use swimming pool without adult supervision located on fence, not visable from access to pool from clubhouse. .2530(c) All pool signage shall be visible upon entrance to the pool and permanently affixed.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Observed no paper towels in men's room.

View this inspection on the county portal ›

Jul 26, 2024 22 demerits · 6 violations
Inspector comments: OSV to pool with Violet Turner, Weaver Cooke, for return construction and operating permit inspection. All items corrected from previous visit. Hold released in system. CPO also works at different property. CPO is required to make daily visits to the property when the pool is open to the public to manage the pool. Noted - Deck depth marker written as 5 in. 0 ft. during site visit. Given one week to repair to read 0 ft. 5 in. Aquarian stated would be done on Monday, July 29th. Provide photograph documentation of repair. Chlorinator full of tabs but no extra available onsite. Gave operator until Monday to provide. If runs out, the pool shall close to the public. Provide photograph documentation of tabs once received. Permit issued for no night swimming. Permit Restriction: Flow meter must remain operable. Flow required at 77 gpm to 140 gpm to meet turnover and flow restriction of the filter. Pool Width 34 ft.; Rope Length 50 ft.; Max Depth 5 ft. Filtration Pentair Intelliflo VSF, 011056 with (2) VGBA-2017 Aquastar 12MFxxx drain covers. EQ lines plugged in skimmer. Feature Pentair Superflo VST, 342002 with (2) VGBA-2008 Aquastar 9MFxxx drain covers.
#3 · Water quality: pool water pH −6
Pool pH at 8.2. Corrected to 7.8 during the inspection.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Cyanuric acid and total alkalinity not recorded weekly. Operator tested while onsite. Ensure weekly record keeping for CYA and total alkalinity. Ensure daily record keeping for chlorine, pH and main drain checks.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Opening between light and wall >1/2". Corrected during the inspection.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
One picket bent with >4" between. Corrected during the inspection.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Floor wet in pump room due to leak at chlorinator. Replaced o-ring during site visit and repaired leak. Bicarb on chemical storage room floor. Keep up off the floor. Corrected during the inspection.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Some stalls missing toilet paper in restrooms. Provide toilet paper.

View this inspection on the county portal ›

Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “ALDEN AT WESTMOOR, THE” or State ID 2060501621). Inspection type (routine vs. follow-up) is not published in the county's data.