6demerits
VILLAS AT TREVI VILLAGE, THE
11110 TREVI VILLAGE BLVD, Charlotte, NC 28262
Seasonal Swimming Pool · NC permit/State ID 2060501626
Latest result6 demerits
Last inspectedApr 6, 2026
Inspections on record2
On record sinceApr 23, 2025
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Apr 23, 2025Lower is betterApr 6, 2026
Inspections & violations
Apr 6, 2026 6 demerits · 2 violations
Inspector comments: PERMIT RESTRICTIONS:
1). Filtration flow meter shall remain operable. Flow required at 69 GPM to 138 GPM to meet turnover and flow restrictions of the suction pipe sizing.
2). Feature pump flow meter must remain operable. Flow shall not exceed 62 GPM due to drain Cover Flow restriction. Suction Hazard.
NOTE:
- This pool cannot use the feature until flow restrictions verified by the department.
- The pool operator stated that they are not and will not utilized the pool feature for the season.
- Pool operator: Frank Marcum present during permit inspection.
- Night Swimming is NOT Permitted .
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(10) Provide test kit capable of measuring disinfectant level, cyanuric acid and total alkalinity.- Observed several testing chemicals kit are expired on year 2024 or 2025. Obtain a new and up to date chemicals testing kit.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
.2526(a) Post a shower sign visible upon entrance to the pool.- Observed no shower sign at the pool. Obtain a shower sign.
Apr 23, 2025 14 demerits · 3 violations
Inspector comments: No night swimming
Pumps and drain covers verified during inspection as same on PDSC form
Filtration pump must be 69 gpm to 138 gpm. Feature pump must not exceed 62 gpm. Flow meters must remain operational.
Flow rates on both pumps were incorrect during inspection, but operator was able to adjust speed on variable speed pumps and the flow rates were reduced within the permit restriction ranges.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
.2539(b) All suction fittings shall be installed in accordance with the manufacturer's instructions. Drain covers are only approved if filter pump flow is below 138 gpm. Flow observed on flow meter during inspection was above 180 gpm. CDI - Operator adjusted variable speed pump and reduced the flow on flow meter to 120 gpm during inspection.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Debris present on bottom of pool
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Clean debris out of skimmer baskets.
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “VILLAS AT TREVI VILLAGE, THE” or State ID 2060501626). Inspection type (routine vs. follow-up) is not published in the county's data.