8demerits
BLVD 98
9825 UNIVERSITY CITY BLVD, Charlotte, NC 28213
Seasonal Swimming Pool · NC permit/State ID 2060501634
Latest result8 demerits
Last inspectedMay 14, 2026
Inspections on record2
On record sinceMay 15, 2025
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
May 15, 2025Lower is betterMay 14, 2026
Inspections & violations
May 14, 2026 8 demerits · 2 violations
Inspector comments: Permit Restriction: Flow meter must remain operable. Flow required at 125 gpm to 138 gpm to meet turnover and flow restriction of the suction piping.
The below was verified during time of inspection and was in compliance:
1. New Pump Pentair Intelliflo3 VSF 011076, 3 hp
2. Blue White flow meter reading the above flow range.
3. Main drain, skimmer, and return line all 3” pipe through floor.
4. (2) Aquastar R12MFxxx 2017 drain covers.
5. (1) Hayward HCF363T filter
6. (10) returns either on the floor or the wall.
7. (7) skimmers with EQ lines disabled in skimmer and on wall.
NIGHT SWIMMING NOT PERMITTED
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed some furniture on pool deck less than 6 feet from pool surface. Corrected during inspection to be in accordance with notated rule.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Observed flow meter not operable. EHS waited for issue to be corrected during inspection, and the required flow range was verified by EHS
May 15, 2025 8 demerits · 2 violations
Inspector comments: Restriction: Pump must remain set at 3450 RPM to meet turnover of 126 GPM. Pool pump was set at 3450 RPM.
No night swimming permitted.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed some debris on floor of pool.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing, self-latching. Observed one gate not self closing and doors from building out to pool with automatic unlock and no alarm. CDI Gate was fixed so that it self closed and latched. Door automatic unlock was disengaged. All gates/doors must be self closing, self latching or have an audible alarm when opened.
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “BLVD 98” or State ID 2060501634). Inspection type (routine vs. follow-up) is not published in the county's data.