PARKSIDE CROSSING

15406 PARKSIDE CROSSING DR, Charlotte, NC 28278
Seasonal Swimming Pool · NC permit/State ID 2060501650
Latest result4 demerits
Last inspectedMay 14, 2026
Inspections on record3
On record sinceJul 3, 2025

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

01326 Jul 3, 2025: 0Aug 15, 2025: 26May 14, 2026: 4
Jul 3, 2025Lower is betterMay 14, 2026

Inspections & violations

May 14, 2026 4 demerits · 1 violation
Inspector comments: Inspection was completed with CPO Joe Brennan. Pool perimeter is fence between amenity building and restroom. Restroom doors and exterior doors of the amenity building are the pool barrier.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 8 ft of clear walking space around the pool at all times (>1600 sq. ft). Observed furniture only allowing 6 ft of clearance around the pool. CDI - Furniture moved to allow 8 ft of clearance around the pool.

View this inspection on the county portal ›

Aug 15, 2025 26 demerits · 7 violations
Inspector comments: Intent to Suspend issued for: .2528 - doors from restrooms shall self-close, self-latch or self-close with audible alarm. .2523 - repair wall and deck depth markers so legible and 4 ft. lettering. .2534 - install fresh air intake vent per plan approval. Zero entry into pool with slope at 13% grade. Grade exceeds rule requirement and requires repair prior to 2026 operating season. SP4.1 indicates that slope shall 1/4" min slope. Slope shall not exceed 1 ft. per 10 ft. or 1% grade. David Schult present during inspection.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Multiple skimmers missing weirs. Not more than half. Replace weirs in skimmer per NSF approval. Some skimmers with build-up. Keep skimmers free of debris.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
Wall depth marker at zero entry cut off and not reflecting actual water depth. Reads 0 ft. 0 in. with water. Other side reads 0 ft. 6 in. Wall depth markers shall be clearly visible. 4" height required. Deck depth marker with 0 in upside down. Depth markers shall be legible. Repair depth marker on pool wall to reflect actual depth and depth marker on deck so legible. Depth markers shall reflect true depth. Intent to Suspend issued.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Doors from restrooms into main entry hall with audible alarms disabled. Doors shall either self-close, self-latch or self-close with an audible alarm. Intent to Suspend issued.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Pool furniture 7 ft. from pool edge. Maintain 8 ft. clearance around the pool.
#22 · Premises: emergency telephone provided −6
Incorrect phone number posted at pool phone. Corrected during the inspection.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
No fresh air intake vent in chemical storage room. Provide fresh air intake vent. Original plan approval shows fresh air intake vent. Install per plan approval. Shown at door into chemical storage room. Intent to Suspend issued. Grill over backwash pit raised with offset >1/2". Appears to be trip hazard. Recommend lowering grate. Recommend adding aggregate to floor finish in pump room and chemical storage room. Floor slick and appears to be a slip hazard.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Sink in men's restroom inside stall without soap. Provide soap at all sinks. Family restroom not accessible or viewed. Could not find keys.

View this inspection on the county portal ›

Jul 3, 2025 0 demerits · 0 violations
Inspector comments: Note: Pool builder to lower pipe for filtration pump into backwash pit or otherwise remove trip hazard created by filtration line running over pump room floor in front of filters. Pool perimeter is fence between amenity building and restroom. Restroom doors and exterior doors of amenity building are pool barrier. Pump flow Filtration 350gpm, Feature 220gpm Max depth 5’ Rope Length 50’

No violations were recorded for this inspection.

View this inspection on the county portal ›

Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “PARKSIDE CROSSING” or State ID 2060501650). Inspection type (routine vs. follow-up) is not published in the county's data.