4demerits
MODERA LOSO
3405 S TRYON ST, Charlotte, NC 28205
Seasonal Swimming Pool · NC permit/State ID 2060501651
Latest result4 demerits
Last inspectedApr 15, 2026
Inspections on record3
On record sinceJul 28, 2025
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Jul 28, 2025Lower is betterApr 15, 2026
Inspections & violations
Apr 15, 2026 4 demerits · 1 violation
Inspector comments: PERMIT ISSUED.
POOL IS NOT PERMITTED FOR NIGHT SWIMMING
FLOW METER MEASUREMENT: 70 GPM
5% FLOW METER OBSERVED TO BE OPERATING AND PROPERLY INSTALLED.
PERMIT RESTRICTION: Flow reduction required due to number of returns lower than design flow. Flow must be at least
46gpm for turnover and cannot exceed 120gpm for number of returns. Properly installed 5% accurate flow meter
must be operational at all times. Flow greater than 170 gpm exceeds drain covers. Suction hazard. Note: All
fencing/gates around pool do not meet requirements. Balconies from units and lounge building barrier - doors from
buildings barrier. Salt not approved as primary chlorination.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing, self-latching. Observed two different building doors self-close but unable to self-latch. CDI: CPO repaired doors and they now self-close and self-latch.
Aug 26, 2025 2 demerits · 1 violation
Inspector comments: Intent to Suspend issued for .2526 - install hose bib with backflow prevention device in pump room.
Note: Shower signage blocked by pool furniture. Recommend moving furniture so that signage stays clearly visible. Facility pool rules signage does not meet code requirements. Generic signage required.
Randy Lundquist present during the inspection.
#33 · Dressing and sanitary facilities: hose bibbs and floor drains provided −2
No hose bib in pump room. Provide hose bib with backflow prevention device. Intent to Suspend issued.
Jul 28, 2025 0 demerits · 0 violations
Inspector comments: Observed no non-compliant items.
Permit issued.
Pool not approved for night swimming.
Max Depth - 3 1/2'
Pool Width - 22'
Rope Length - 33'
Pump - Hayward HCP3020VSP
Main Drain - Aquastar A10RCFRxxx
Permit Restriction: Flow reduction required due to number of returns lower than design flow. Flow must be at least 46gpm for turnover and cannot exceed 120gpm for number of returns. Properly installed 5% accurate flow meter must be operational at all times. (Suction Hazard)
Note: Barrier is building, fencing/gates around pool does not meet requirements. Salt not approved as primary chlorination.
No violations were recorded for this inspection.
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “MODERA LOSO” or State ID 2060501651). Inspection type (routine vs. follow-up) is not published in the county's data.