0demerits
GALLOWAY RIDGE
7033 ALVA TR, Charlotte, NC 28216
Seasonal Swimming Pool · NC permit/State ID 2060501652
Latest result0 demerits
Last inspectedApr 10, 2026
Inspections on record3
On record sinceAug 27, 2025
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Aug 27, 2025Lower is betterApr 10, 2026
Inspections & violations
Apr 10, 2026 0 demerits · 0 violations
No violations were recorded for this inspection.
Sep 23, 2025 10 demerits · 3 violations
Inspector comments: Lizzie Morris present during the inspection.
One skimmer basket damaged during the inspection while trying to remove. Replace skimmer basket (near smaller steps) within 30 days.
Intent to Suspend issued for:
.2528 - move Knox box to eliminate foothold.
.2525 - maintain weekly record keeping for CYA and TA
.2537 - maintain 3 ft. clearance around equipment - move liquid feeder tubing to allow equipment accessible.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Cyanuric acid and total alkalinity not recorded weekly. Record weekly. Intent to Suspend issued.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Knox box added to front of building above stone on front wall. Provides horizontal within 45" of top of barrier. Eliminate horizontal, either lower or move further left to ensure 45" at angle to top of barrier. Intent to Suspend issued.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Hayward CAT controller installed. Piping run across floor. Equipment not accessible. Move piping so that 3 ft. clearance available around equipment. Intent to Suspend issued.
Floor wet in pump room after backwash. Keep floor dry. Move/cut piping for backwash line to eliminate water on pump room floor.
Aug 27, 2025 0 demerits · 0 violations
Inspector comments: Permit issued.
Pool not approved for night swimming.
Permit Restriction Flow meter must remain operational. Pool pump flow must be at least 247gpm for turnover and not exceed 280gpm for number of returns and filtration rate.
Note: 2 sets of life safety equipment required
Pump: Hayward HCP3020VSP (x2)
Main drains: Aquastar 1216xxx VGBA2017 (x2)
No violations were recorded for this inspection.
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “GALLOWAY RIDGE” or State ID 2060501652). Inspection type (routine vs. follow-up) is not published in the county's data.