12demerits

ONE WEST END

2121 CALDERA ST, Charlotte, NC 28208
Seasonal Swimming Pool · NC permit/State ID 2060501674
Latest result12 demerits
Last inspectedApr 9, 2026
Inspections on record2
On record sinceApr 1, 2026

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

0612 Apr 1, 2026: 12Apr 9, 2026: 12
Apr 1, 2026Lower is betterApr 9, 2026

Inspections & violations

Apr 9, 2026 12 demerits · 2 violations
Inspector comments: Inspection conducted with CPO Jeremy Hines and builder Justin Frantz. Left inspection at 9:55 AM and came back at 10:40 AM once phone was fixed. Permit restriction: Flow meter must remain operable and be between 39 GPM to meet turnover and 62 GPM for the flow restriction of the skimmer and main drain limitation. - Corrected. CPO had turned up pump to vacuum, turned speed back down. Observed items fixed from last inspection. Restrooms stocked, loose urinal piping fixed, pool floor vacuumed, trip hazard removed, chemicals properly stored. Conducted pre-permit inspection. Permit issued with the following conditions No Night Swimming Flow meter must remain operable and be between 39 GPM for minimum turnover and 62 GPM for flow restriction of the skimmer and main drain piping limitation.
#3 · Water quality: pool water pH −6
PH 8.4. .2535(1) Maintain pH at 7.2 to 7.8. - Corrected to 7.5.
#22 · Premises: emergency telephone provided −6
Emergency phone not functioning. .2530(f) Emergency phone shall remain operable. - Corrected.

View this inspection on the county portal ›

Apr 1, 2026 12 demerits · 4 violations
Inspector comments: Inspection conducted with CPO Jeremy Hines and property manager Allen Mzili. Permit condition that flow meter must remain operable and flow is required to be between 39 GPM for minimum turnover and 62 GPM for flow restriction of the skimmer and main drain piping. - Observed at 61 GPM today. From construction final inspection,verified > 45” between access control junction box and the top of the fence. Observed granular cyanuric acid on pool floor and around returns. G.S. 130A-(2)3 Ensure all chemicals are added to the pool per manufacturer’s instructions and pool is kept closed until chemicals have fully dissolved and thoroughly mixed in the pool. - Pre-permit item. Some items from construction need to be addressed. - Trip hazard at sunshelf. Can be temporarily addressed with a cap prior to permit being issued. - Can give 30 days to permanently address if not able permanently addressed on Friday. - Fan in pump room and chemical storage room tied to light switch in pump room. Fans must be wired to operate continuously, can not be tied to light switch. Will need to run separate switches for fans and lights or plate out the wiring for fans so they run continuously. May need an electrical inspection for the work. - Can give 30 days. - No fresh air intake for pump room door and air intake for chemical storage room door painted shut. Plans call for minimum free area of 100 square inches for pump room door and 1900A Air Louvers for chemical storage room door. - Can give 30 days to address. - Foothold at foot showers by both gates. - Can give 30 days to permanently address. Can install full sized showers, ensure that top of shower base is at least 45” from the top of the fence and no other footholds ‘T’ off of the shower post. Pre-permit inspection did not pass G.S. 130A-(2)3 17) 25) 29) Will need to pay a $100 re-inspection fee by calling our office (980) 314-1620 and paying with a credit card prior to scheduling a re-inspection.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Top of the foot showers 36” from the ground. Less than 45” from top of the shower to the top of the fence. .2528(a) Maintain 45" between bottom horizontal and next horizontal on fence and/or gate (post-May 2010). - Can give 30 days to permanently address.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Handrail at sunshelf removed. Temporary cap over anchors sticks up 1 inch. .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. - Pre-permit item.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Fan tied to light switch in pump room. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room. - Can give 30 days. Fan tied to light switch in pump room. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room. - Can give 30 days. Some chemicals stored in the pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. - Pre-permit item. Bag of dry chemicals on pump room floor. .2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor. - Pre-permit item.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
No soap in restrooms. .2526(j) Provide soap and soap dispenser, no glass, at each sink. - Pre-permit item. No toilet paper in restrooms. .2526(l) Provide toilet paper on toilet paper dispensers in restrooms. - Pre-permit item. Piping and flush controls for urinal loose. .2526(m) Keep restrooms and fixtures clean and in good repair.

View this inspection on the county portal ›