‹ Back to search

28demerits

GREYS HARBOR LAKE NORMAN

8701 PINNACLE CROSS DR, Huntersville, NC 28078
Seasonal Swimming Pool · NC permit/State ID 2060501688
Latest result28 demerits
Last inspectedMay 27, 2026
Inspections on record1
On record sinceMay 27, 2026

This facility type is scored in demerits: lower is better (0 = no violations found).

Inspections & violations

May 27, 2026 28 demerits · 7 violations
Inspector comments: Inspection conducted with CPO Ronald Haltom. Follow up from inspection on 5/19. Facility changing from annual to seasonal pool. Residents will only be able to access the grill area and other common areas in the pool enclosure when the pool is permitted during the Summer. Will need to apply for annual pool permit to be able to use these areas year-round. Observed roughly 1/4” of standing water on the pool deck around the 4ft 6in depth marker. Prior to 2027 pool permit being issued, will need to make deck meet .2522 of the NC Pool Rules. Deck shall slope 1/4 - 1/2 inch per foot away from pool to an indirect drain or deck edge. Deck shall be impervious, slip resistant, and without any gaps or offsets > 1/2 inches. Decking will need to be inspected by a pool senior prior to scheduling the 2027 pool permit inspection. Permit issued with the following conditions No Night Swimming No label on pump. Will require impeller verification if motor changed to a different HP. Paper permit will be on our website, https://eh.mecknc.gov/pools, in 3-5 business days for your records.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
One weir with a section of pool noodle attached, not able to move freely. .2518(k) Provide functional weirs. - Corrected.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Ladder extends > 6" into pool. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall. Handrail missing escutcheon plate. .2521 Install handrails per manufacturer instructions.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Throw rope 48 feet long. .2530(a) Provide USCG approved ring buoy with attached 50 foot throw rope. - Corrected.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Pre-2010 fence less than 48" high throughout. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. Pre-2010 fence with gaps > 4" through the fence. .2528(a) Provide no openings in fence and/or gate greater than 4"x4". Pre-2010 fence with footholds < 30” between horizontals. .2528(a) Maintain at least 30" between bottom horizontal and next horizontal on fence and/or gate.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Deck not sloped to drain, roughly 1/4 inch of standing water. .2522(f) Deck shall be sloped to drain. - Will need to correct before permit is issued for 2027.
#22 · Premises: emergency telephone provided −6
Incorrect dialing instructions. .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. - Corrected.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Some chemicals stored in close cupboards with no ventilation. .2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up.

View this inspection on the county portal ›