0demerits
CANDLEWYCK SWIM CLUB-WADING
7151 CANDLEWYCK LN, Charlotte, NC 28226
Seasonal Wading Pool · NC permit/State ID 2060510008
Latest result0 demerits
Last inspectedMay 5, 2026
Inspections on record14
On record sinceApr 23, 2014
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Apr 23, 2014Lower is betterMay 5, 2026
Inspections & violations
May 5, 2026 0 demerits · 0 violations
Inspector comments: No violations noted.
Inspection completed with CPO, Brandon Vaughn.
Night swimming not permitted.
No violations were recorded for this inspection.
May 13, 2025 0 demerits · 0 violations
Inspector comments: No violations observed during the inspection of this wading pool
No violations were recorded for this inspection.
Apr 16, 2024 6 demerits · 1 violation
Inspector comments: Inspection conducted with CPO, Drew Swoope present.
PDSC form reviewed and verified. All non-compliant items corrected.
Night swimming is not permitted.
Permit issued.
#2 · Water quality: disinfectant residual provided by −6
.2531(a) Maintain chlorine in wading pools or children activity pools at least 2.0 ppm. Observed chlorine at 0 ppm. CDI - CPO corrected to 9.
Apr 28, 2023 0 demerits · 0 violations
No violations were recorded for this inspection.
Apr 26, 2023 0 demerits · 0 violations
No violations were recorded for this inspection.
Apr 27, 2022 0 demerits · 0 violations
Inspector comments: David Schult present during inspection. Observed no violations at this time.
No violations were recorded for this inspection.
Apr 13, 2021 18 demerits · 4 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed debris build up in skimmer. PO emptied skimmer during inspection.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
.2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. Observed 3 inch opening connected to an overflow drain in side of wading pool without inlet/face plate present. PO provided an inlet during inspection.
#22 · Premises: emergency telephone provided −6
.2530(f) Emergency phone shall remain operable. Observed emergency telephone not ringing when called back. EHS picked up phone and can hear talking on other end, but no ringing occurred during phone call. PO replaced phone during inspection. Phone now rings when called back.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Observed flow meter stuck during inspection. PIC able to fix flow meter during inspection. Flow meter now in operation.
Apr 9, 2020 4 demerits · 1 violation
Inspector comments: Night Swimming not approved.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
entrance gate to the wading pool was not latching fully, repaired by operator.
May 17, 2019 0 demerits · 0 violations
Inspector comments: No violations were observed during today's inspection.
No violations were recorded for this inspection.
Apr 13, 2018 0 demerits · 0 violations
Inspector comments: Did not observe any demerits today.
No violations were recorded for this inspection.
May 5, 2017 14 demerits · 3 violations
Inspector comments: update psdc form for baby pool SP320521M pool want open till psdc form is approved
#3 · Water quality: pool water pH −6
baby pool ph was low 7.0 but corrected to 7.6 during inspection
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
self-latching gate did not close properly and had chain placed around gate with a lock
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
flow meter was stuck
May 11, 2016 20 demerits · 4 violations
#2 · Water quality: disinfectant residual provided by −6
Observed pool chlorine reading 0.6 ppm at start of inspection. CDI - corrected during inspection. CPO corrected chemicals and chlorine read above 10 ppm by end of inspection. He will continue to adjust before pool opens so that chlorine is at least 2.0 ppm but not so high as above 10.0.
#3 · Water quality: pool water pH −6
Observed pool pH reading leass than 6.8 at start of inspeciton. CDI - corrected during inspeciton. CPO adjusted chemicals and pH read 7.8 by end of inspection.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Obs.erved leaf debris inside pool and on floor of pool.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Obslerved flowmeter not operational at start of inspeciton. CDI - CPO repaired it and it was operational by end of inspection.
May 8, 2015 6 demerits · 2 violations
Inspector comments: 8.. .2518 Skimmer for wading pool does not have a equilizer. Will pass along this information to Katie Wilson and Tim Dutcher.
#19 · Premises: signs prohibit glass containers or pets in pool area −4
.2530- Signage must be posted at wading pools. No signs up in wading pool area as CPO was not sure if the pool would be opened. All required signage posted.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526 - Hot water in restrooms shall not exceed 110F - Hot water in restrooms ranging from 111F-113F. Adjust.
Apr 23, 2014 14 demerits · 4 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Pool wall should be regrouted/sealed between top of wall and deck.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
ensure that all surface skimmers are maintained free of floating debris.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Noted areas on deck that need to be addressed. Regrout areas that are greater than 1/4 inch. (Trip Hazard)
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Toilets were not functioning, must repair prior to operation.
Mirrors must be constructed of shatterproof materials.
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “CANDLEWYCK SWIM CLUB-WADING” or State ID 2060510008). Inspection type (routine vs. follow-up) is not published in the county's data.