0demerits
CEDARFIELD II
8873 STRATTON FARM ROAD, Huntersville, NC 28078
Seasonal Wading Pool · NC permit/State ID 2060510015
Latest result0 demerits
Last inspectedMay 6, 2026
Inspections on record15
On record sinceMay 16, 2014
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
May 16, 2014Lower is betterMay 6, 2026
Inspections & violations
May 6, 2026 0 demerits · 0 violations
Inspector comments: No violations on this inspection
Permit restrictions: Flow must remain operable. Flow shall be kept at 10pm to 49gpm to meet turnover and flow restriction of filter.
No night swimming
Inspection completed with CPO Niell Riek
No violations were recorded for this inspection.
May 20, 2025 18 demerits · 4 violations
Inspector comments: NO NIGHT SWIMMING.
FLOW METER MUST REMAIN OPERABLE. FLOW SHALL BE KEPT AT 10-49 GPM TO MEET TURNOVER AND FLOW RESTRICTION OF FILTER.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8.
Observed pool pH 7.0. CDI
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522 (c) Provide at least 4 ft clear walking space around wading pool at all times.
Observed chairs on pool deck < 4’ from pool edge. CDI
#22 · Premises: emergency telephone provided −6
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone.
Observed phone number was incorrect on signage. CDI new number posted at sign. 704-947-5031
#26 · Equipment room: valves and pipes identified by color codes or labels −2
.2518(d) Piping and valves shall be labeled with color codes or labels.
Pipes not labeled with directional flow.
Jul 16, 2024 12 demerits · 4 violations
Inspector comments: Inspection conducted with CPO Mike Henson.
Issues from previous inspection corrected. Verified the following for updated in-field plan review:
Electrical permit E4638297 passed inspection 6-4-2024.
Pentair Intelliflo 3 011068 1.5 HP pump
TR-50 filter
4x returns
1 skimmer with EQ line plugged per state guidelines
1.5” piping for skimmer, main drain, and return
4x Aquastar WAV9WRxxx 2017 drain covers
Permit issued with the following conditions
No Night Swimming
Flow meter must remain operable. Flow shall be kept at 10 GPM to 49 GPM to meet turnover and flow restriction of filter.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
New log sheets provided for wading but, but no Total Alkalinity or Cyanuric Acid check for pool or wading pool for July. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. - Corrected. Operator took readings for pool and wading today.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Non-functioning gate with plexiglass installed, creating new horizontals in the fencing. .2528(b) Pre-2010 horizontals shall not be located less than 30" in height.
#26 · Equipment room: valves and pipes identified by color codes or labels −2
No labeling on new piping. .2518(d) Piping and valves shall be labeled with color codes or labels.
#27 · Equipment room: filter backwash discharged through an air gap −2
No air gap for backwash line. .2513(b) Filter backwash shall be discharged through an air gap.
Jul 8, 2024 24 demerits · 7 violations
Inspector comments: Pre-permit and in-field plan review inspection conducted with CPO Mike Henson.
911 has 8801 Stratton Farm Rd. Correct address is 8873 Stratton Farm Rd. Follow up with phone company to correct.
Electrical permit E4638297 passed inspection 6-4-2024. In-Field Plan review did not pass. Observed the following:
Pentair Intelliflo 3 011068 1.5 HP pump
TR-50 filter
4x returns
1 skimmer with EQ line plugged per state guidelines
1.5” piping for skimmer, main drain, and return
4x Aquastar WAV9WRxxx 2017 drain covers
Pre-permit inspection did not pass
In-field plan review
5)
8)
16)
22)
There is a $100 re-inspection fee that must be paid by calling our office (980) 314-1620 and paying with a credit card prior to scheduling a re-inspection.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Log sheet does not provide separate areas for pool and wading main drain, Total alkalinity, and cyanuric acid checks. No records for total alkalinity, cyanuric acid, or main drains for wading pool. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. - Pre-permit item.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Skimmer basket too big to properly fit in the skimmer. Top above the water line. .2518(k) Provide functional skimmer basket designed for this skimmer. - Corrected.
Weir not fully installed, stuck in skimmer throat. .2518(k) Provide functional weirs. - Pre-permit item.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
One wading pool gate stuck. Not able to test. .2531(a) Wading pool gates shall open away from the swimming pool and be self-closing and self-latching. - Pre-permit item.
#18 · Premises: lifeguards present or warning signs posted −4
No lifeguard on duty sign not posted in wading pool area. .2530(c) Provide "Warning - No Lifeguard on Duty" in 4" lettering. - Corrected.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Spare pump basket not provided. .2518(e) Provide a spare basket for pump. - Pre-permit item.
#26 · Equipment room: valves and pipes identified by color codes or labels −2
No labeling on new piping. .2518(d) Piping and valves shall be labeled with color codes or labels.
#27 · Equipment room: filter backwash discharged through an air gap −2
No air gap for backwash line. .2513(b) Filter backwash shall be discharged through an air gap.
Apr 27, 2023 6 demerits · 2 violations
Inspector comments: Verified the main drains and pumps.
Night swimming is prohibited.
David Johnson, CPO present during the inspection.
Permit Issued.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Observed the flow meter stuck. CDI - CPO repaired
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Bathroom mirrors are not shatterproof.
.2526(k) Provide shatterproof mirrors.
Apr 27, 2022 8 demerits · 2 violations
Inspector comments: Night swimming is not permitted.
#3 · Water quality: pool water pH −6
ph was below 7.0. Maintain 7.2 to 7.8. Corrected during inspection.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Bathroom mirrors are not shatterproof.
May 14, 2021 14 demerits · 3 violations
Inspector comments: Night swimming NOT allowed.
Inspection completed with Jacob Wilks.
Report to 'Jacob Wilks'
No signature due to COVID-19.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Observed pH of 8.0. CDI: CPO added bicarb and lowered pH. pH now 7.2
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed debris on pool floor. CDI: CPO cleaned.
.2514(c) Pool surfaces shall be slip resistant.Observed small areas of wading pool where paint sealant beginning to separate. This will need to be corrected for 2022 permit to be issued.
#13 · Pool maintenance: contrasting band on steps and benches −4
.2521(b) Provide at least 2"x 2" tile for contrasting color band within 1" of adjacent tiles and edge of the stair tread. Observed "jagged" color band tiles in wading pool. This will need to be corrected before 2022 permit will be issued.
Apr 21, 2020 6 demerits · 3 violations
Inspector comments: Inspection conducted with Jacob Wilks, Landon Wiese, and George Mulligan. Due to COVID-19 precautions, inspection was not signed by the operator.
Verified PDSC information. Observed unlabeled Pentair Challenger pump with 1 HP motor.
Flow meter numbering heavily worn. Recommend replacing.
Permit issued. No night swimming.
“Issuance of a permit by this department does not negate closure required by Executive Order No. 120 or subsequent Orders in
effect unless such Orders are rescinded or superseded by another applicable Order.”
#26 · Equipment room: valves and pipes identified by color codes or labels −2
Fill line piping not labeled. .2518(d) Piping and valves shall be labeled with color codes or labels.
#27 · Equipment room: filter backwash discharged through an air gap −2
No air gap for backwash line. .2513(b) Filter backwash shall be discharged through an air gap.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
No backflow preventor on fill line. .2512(b) Water introduced into the pool, either directly or by the circulation system, shall be supplied through an air gap, anti-siphon vacuum breaker, or backflow preventer.
Apr 2, 2019 0 demerits · 0 violations
No violations were recorded for this inspection.
Jul 26, 2018 14 demerits · 3 violations
Inspector comments: Verified PDSC information
Immediate suspension issued.
Call Chris Sells when pool chemistry is correct at 704 576 8678.
Observed no Cl product suitable for the chlorinator installed at time of inspection.
Proper Cl product brought during inspection.
#2 · Water quality: disinfectant residual provided by −6
Observed Cl at 0 ppm in pool
Maintain at least 2 ppm Cl wading pools.
Immediate suspension.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Observed no records of total alkalinity or cyanuric acid.
Maintain records as required.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed plaster damaged on top step.
Keep pool floor in good repair.
Apr 12, 2018 12 demerits · 3 violations
#3 · Water quality: pool water pH −6
.2535 Pool PH kept between 7.2-7.8; Observed PH measuring 7.0 during inspection; CDI PH corrected to 7.2 during inspection.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537 Pool Floor kept clean; Observed pool floor collecting debris in need of general cleaning.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533, .2534, .2537 Keep equipment rooms dry; Observed pump room wet.
May 5, 2017 8 demerits · 3 violations
Inspector comments: Permit will be posted online at Meckpools.charmeck.org in 1-3 business days. Print a copy to post in the pool area.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Gate not self-closing. Ensure gate is self-closing and self-latching. Corrected by operator.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Fans in pump room and chemical storage room not fuctioning. Provide continuous forced air or cross ventilation for pump room and chemical storage room.
Light in chemical storage room not working. One bulb in pump room burned out. Provide adequate lighting in pump room and chemical storage room.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Two stalls in the women's restroom and two stalls in the men's restroom missing toilet paper. Provide toilet paper on a roll for stalls.
Apr 27, 2016 2 demerits · 1 violation
Inspector comments: PDSC information correct.Pre-permit inspection passed.Permit not valid until available online.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Observed toilets dirty in bathrooms.Keep bathrooms clean.
May 1, 2015 14 demerits · 5 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed chipping paint of pool floor. Keep in good repair.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed flow meter not working. Repairl
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed pump room floor wet. Keep dry.
#27 · Equipment room: filter backwash discharged through an air gap −2
No air gap at backwash line to pit. Provide air gap.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
Observed no backflow prevention on hose bibs. Provide backflow prevention device.
May 16, 2014 22 demerits · 7 violations
Inspector comments: Note: Chlorine puck in skimmer basket. Removed during inspection. Do not place chlorine directly in pool.
Note: 911 address does not match records. Will follow-up.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed chipping pain on pool floor. Keep in good repair.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Deck furniture <4 ft to pool. Corrected.
#22 · Premises: emergency telephone provided −6
Emergency phone not operating. No dial tone. Corrected.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed pump room floor wet. Keep dry.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Observed urinals not operating properly. Repair.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
Observed no backflow prevention on hose bibs. Provide backflow prevention device.
#27 · Equipment room: filter backwash discharged through an air gap −2
No air gap at backwash line to pit. Provide air gap.