0demerits
RAINTREE COUNTRY CLUB
8600 RAINTREE LANE, Charlotte, NC 28277
Seasonal Wading Pool · NC permit/State ID 2060510075
Latest result0 demerits
Last inspectedMay 8, 2026
Inspections on record13
On record sinceMay 16, 2014
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
May 16, 2014Lower is betterMay 8, 2026
Inspections & violations
May 8, 2026 0 demerits · 0 violations
Inspector comments: Inspection completed with Brandon Vaughn
No Demerits notated
No violations were recorded for this inspection.
May 6, 2025 10 demerits · 2 violations
Inspector comments: NIGHT SWIMMING NOT PERMITTED.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. - REPEAT - Observed one door leading from clubhouse and one door from concession stand with exterior access not self-latching and without a working audible alarm. - CDI - CPO installed an audible alarm on each door.
#22 · Premises: emergency telephone provided −6
.2530(f) Provide signage with location of emergency phone if not visible from all areas inside pool enclosure. - Observed emergency phone located inside attendant room without signage posted indicating where the phone is located visibly on the pool deck. - CDI - CPO posted signage indicating where emergency phone is located.
May 8, 2024 4 demerits · 1 violation
Inspector comments: No night swimming
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Observed flow meter not properly functioning. CDI- CPO repaired during inspection.
Apr 20, 2023 0 demerits · 0 violations
No violations were recorded for this inspection.
May 17, 2022 18 demerits · 6 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Clean bottom of pool.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Maintain 45" between bottom horizontal and next horizontal on fence and/or gate (post-May 2010). // .2528(a) Provide no openings in fence and/or gate greater than 4"x4". Fence does not meet current fencing requirements. If fence is replaced or damaged then the fence must be built to current fencing rules.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Flow meter not functioning.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(d) Pump room floor shall be kept dry and free of standing water. Standing water on floor of pump room.
#26 · Equipment room: valves and pipes identified by color codes or labels −2
.2518(d) Piping and valves shall be labeled with color codes or labels. Labels on valves and piping have worn off.
#27 · Equipment room: filter backwash discharged through an air gap −2
.2513(b) Filter backwash shall be discharged through an air gap. No air gap between bottom of backwash pipe outlet and the backwash pit.
Apr 9, 2021 10 demerits · 2 violations
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8.Pool pH was at 7.0, corrected to 7.2 during time of inspection.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed debris on pool surface.
May 14, 2020 8 demerits · 2 violations
Inspector comments: No night swimming approved. Contact inspector at 704-621-2294 to schedule night swimming approval.
Pool operator stated pool is lifeguarded and with gate attendant.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
Observed PDSC form incorrect and wrong main drain covers with actually Paramount SDX2 main drain covers and incorrect pump installed. New PDSC form submitted and approved while on-site.
#27 · Equipment room: filter backwash discharged through an air gap −2
.2513(b) Filter backwash shall be discharged through an air gap.
Apr 25, 2019 6 demerits · 2 violations
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(e) Provide a spare basket for pump. Observed no spare basket. Spare basket provided during inspection.
#26 · Equipment room: valves and pipes identified by color codes or labels −2
.2518(d) Piping and valves shall be labeled with color codes or labels. Observed no color codes or labels on piping and valves.
May 15, 2018 6 demerits · 2 violations
Inspector comments: Observed chip paint around deck; not greater than 1/2 inch. Make sure to correct. Operator stated that decks would be textured and painted this afternoon. Not a trip hazard just not smooth and easily cleanable.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed flow meter not operating. Operator corrected during the inspection.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed poorly ventilated room with damp floor.
May 4, 2017 14 demerits · 4 violations
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
Drain covers on approved form indicate Paramount SDX Retro but Hayward 8" are installed. Permit will not be issued until updated form submitted and approved.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Gate into wading pool area not self closing and not latching. Corrected while on site.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter present but not operating.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Chemical room wet and poorly ventilated.
May 16, 2016 0 demerits · 0 violations
Inspector comments: Permit wil be released once updated PDSC foorm is received and approved. Pump model number is different from what's on file. Main drian covers are Hayward. Covers are listed as Paramount SDX retro. Please update/submit PDSC forms.
No violations were recorded for this inspection.
May 14, 2015 10 demerits · 3 violations
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
No diving markers not visiable.( Deck painted) No diving markers installed during my inspection.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Chairs 3' from waters edge. Trip hazzard.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Wet in pump room. Chemicals stored on the floor.
May 16, 2014 10 demerits · 2 violations
#2 · Water quality: disinfectant residual provided by −6
No chlorine at time of inspection corrected during inspection.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Clean skimmer basket.
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “RAINTREE COUNTRY CLUB” or State ID 2060510075). Inspection type (routine vs. follow-up) is not published in the county's data.