‹ Back to search

10demerits

SHANNON PARK SWIM CLUB

5126 GRAFTON DR, Charlotte, NC 28215
Seasonal Wading Pool · NC permit/State ID 2060510082
Latest result10 demerits
Last inspectedApr 22, 2026
Inspections on record11
On record sinceJun 24, 2014

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

0918 Jun 24, 2014: 10Jun 25, 2015: 18Jun 20, 2016: 0Jun 22, 2017: 14May 24, 2018: 12May 22, 2019: 6May 26, 2022: 8May 30, 2023: 8May 15, 2024: 0Apr 24, 2025: 4Apr 22, 2026: 10
Jun 24, 2014Lower is betterApr 22, 2026

Inspections & violations

Apr 22, 2026 10 demerits · 2 violations
Inspector comments: PERMIT RESTRICTION - FLOW METER MUST REMAIN OPERABLE AT 25 GPM DUE TO MINIMUM TURNOVER REQUIREMENT OF 22 GPM NOT TO EXCEED 52 GPM FOR FILTER LIMITATION. NO NIGHT SWIMMING.
#2 · Water quality: disinfectant residual provided by −6
.2535(4) Maintain chlorine at least 1.0 ppm. Observed pool chlorine measuring 0ppm. CPO added chlorine tablets and EHS observed chlorine was measuring 10ppm.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed debris on pool walls. CPO cleaned out debris while EHS still on-site.

View this inspection on the county portal ›

Apr 24, 2025 4 demerits · 1 violation
Inspector comments: Permit restriction. Flow meter must remain operable and flow must remain between 22 and 52 gallons per minute at all times. built without equalizer.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed leaf debris in pool

View this inspection on the county portal ›

May 15, 2024 0 demerits · 0 violations
Inspector comments: No violations observed during inspection. Pool is not permitted for night swimming. Permit issued.

No violations were recorded for this inspection.

View this inspection on the county portal ›

May 30, 2023 8 demerits · 2 violations
Inspector comments: 20 GPM No night swimming permitted. Pool hours are from sunrise to sunset.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. PH of pool was 6.8 at start of inspection (7.2-7.8). CDI- CPO increased the pH of the pool to 7.8.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(a) Pump room shall be weatherproof with a minimum ceiling height of 7 ft. Pump room is a concealed box of cement blocks with a wooden top about 3 feet high.

View this inspection on the county portal ›

May 26, 2022 8 demerits · 2 violations
Inspector comments: Observed no pump room. Pool permit issued Confirmed all 2in pipe, 1skimmer, 1 return, Hayward sp2670007x10 at 33gpm
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed gate not self closing, corrected during inspection .2537(b) All gates and doors shall be self-closing, self-latching. Observed fence 36” high. .2528(a) Pool gate shall be at least 48" in height measured from outside of barrier. Pre2010.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed deck damaged at right rear side. Corrected during inspection .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile.

View this inspection on the county portal ›

May 22, 2019 6 demerits · 2 violations
Inspector comments: Verified PDSC information.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed fence 36" at wading pool. Pool built prior to 2010. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Obseved bathroom hand sink leaking. .2626(m) Keep restrooms and fixtures clean and in good repair.

View this inspection on the county portal ›

May 24, 2018 12 demerits · 3 violations
#1 · Water quality: water clear enough to clearly see bottom of pool and pool drain −6
.2535(2) Main drains must be clearly visible from the pool deck. Water cloudy and unable to clearly see maind drains. CDI - Water drained, cleaned, and refilled during the inspection. Main drains clearly visible by end of inspection.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2531(a) Wading pool fencing and gates shall be in compliance with all rules described in Rule .2528. Wading pool fence at 36 inches. Pool constructed prior to 2010.
#27 · Equipment room: filter backwash discharged through an air gap −2
.2513(b) Filter backwash shall be discharged through an air gap. No air gap at backwash.

View this inspection on the county portal ›

Jun 22, 2017 14 demerits · 4 violations
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed wading pool fence at 35 inches, latch at 30 inches. Pool constructed prior to 2010.
#22 · Premises: emergency telephone provided −6
Observed no address posted near emergency phone. Corrected during inspection.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed pump room only an enclosed box. Does not have 7ft height ceiling or approved flooring. Also does not have ventilation. Observed chemicals for wade pool stored in main pool pump room. Observed chemical closet fan damaged.
#27 · Equipment room: filter backwash discharged through an air gap −2
Observed backwash line without air gap.

View this inspection on the county portal ›

Jun 20, 2016 0 demerits · 0 violations

No violations were recorded for this inspection.

View this inspection on the county portal ›

Jun 25, 2015 18 demerits · 6 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed palster cracked in bottom of pool.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Gate latch must be a minimum of 54" from ground. Observed gate latch 41". ITS issued.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed flow meter not properly functioning.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed pump room only an enclosed box. Does not have 7ft height ceiling or approved flooring. Also does not have ventilation.
#26 · Equipment room: valves and pipes identified by color codes or labels −2
Label all pipes for equipment. Observed all pipes unlabeled.
#27 · Equipment room: filter backwash discharged through an air gap −2
Observed backwash line without air gap.

View this inspection on the county portal ›

Jun 24, 2014 10 demerits · 2 violations
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Chairs too close to pool edge. Maintain 4' of clearance.
#22 · Premises: emergency telephone provided −6
Emergency phone not operating. Corrected during inspection.

View this inspection on the county portal ›

Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “SHANNON PARK SWIM CLUB” or State ID 2060510082). Inspection type (routine vs. follow-up) is not published in the county's data.