‹ Back to search

4demerits

SHARON SOUTH

8437 KNIGHTS BRIDGE ROAD, Charlotte, NC 28210
Seasonal Wading Pool · NC permit/State ID 2060510083
Latest result4 demerits
Last inspectedApr 21, 2026
Inspections on record13
On record sinceJun 23, 2014

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

01632 Jun 23, 2014: 10Jul 13, 2015: 32May 5, 2016: 6Jun 8, 2017: 16May 1, 2018: 16Apr 22, 2019: 20May 21, 2021: 4Jun 14, 2021: 0Apr 12, 2022: 0May 16, 2023: 0Apr 10, 2024: 0May 6, 2025: 0Apr 21, 2026: 4
Jun 23, 2014Lower is betterApr 21, 2026

Inspections & violations

Apr 21, 2026 4 demerits · 1 violation
Inspector comments: No night swimming
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept in good repair. Observed deck chipping in areas.

View this inspection on the county portal ›

May 6, 2025 0 demerits · 0 violations
Inspector comments: No night swimming. No violations noted

No violations were recorded for this inspection.

View this inspection on the county portal ›

Apr 10, 2024 0 demerits · 0 violations
Inspector comments: No demerits taken.

No violations were recorded for this inspection.

View this inspection on the county portal ›

May 16, 2023 0 demerits · 0 violations
Inspector comments: No violations.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Apr 12, 2022 0 demerits · 0 violations

No violations were recorded for this inspection.

View this inspection on the county portal ›

Jun 14, 2021 0 demerits · 0 violations
Inspector comments: Inspection completed with Christy Lingle and Karen Reopel present. No signature due to COVID-19.

No violations were recorded for this inspection.

View this inspection on the county portal ›

May 21, 2021 4 demerits · 2 violations
Inspector comments: Onsite visit to pool for construction final and operating permit inspection. Renovation of wading pool. Construction final passed. Operating permit issued. All items from previous visit corrected. Scope – Added sun shelf for wading pool. Eliminated main drains. Turnover through skimmers. New pump and filter installed in pump room after plan approval. Approved by Matt Cook. Replaced like for like pump with new model number – same design and max flow as previous Super Pump. New HCF230 sand filter installed. New chlorinator – Pentair 300 rated for 3 lbs/24 hour. Pool requires .4 lbs/day. Permit issued for no night swimming. If wanting night swimming, a return visit shall be made to verify sufficient lighting. State permit will be available online in 2-3 business days. Sticker will be mailed. Jeff Gaeckle present during the inspection. Hayward Sp2670007x10, 1 hp pump. Pool built without main drains. Skimmer equalizers plugged in skimmer.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Faucet handle not operable in men's restroom. Repair so operable. Restrooms not renovated. Original construction.
#33 · Dressing and sanitary facilities: hose bibbs and floor drains provided −2
No hose bib in restrooms. Original construction. Restrooms not renovated.

View this inspection on the county portal ›

Apr 22, 2019 20 demerits · 5 violations
Inspector comments: Night swimming is not permitted. Pool closes at 8pm. No night swimming visit is required.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Observed PH only reaching 7.0. CDI: corrected to 7.6 during inspection.
#22 · Premises: emergency telephone provided −6
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Observed incorrect phone number posted on pool sign for emergency phone. CDI: correct phone number was written in manually during inspection.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Observed flow meter not working properly. CDI: repaired during inspection.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor. Observed chemical bags stored on the floor in separate chemical storage room.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2626(k) Provide shatterproof mirrors. Mirrors in restrooms not shatterproof.

View this inspection on the county portal ›

May 1, 2018 16 demerits · 5 violations
Inspector comments: VGB and PDSC information verified.
#3 · Water quality: pool water pH −6
Observed PH in wading pool measuring below 6.8 at beginning of inspection. Corrected during inspection to 7.6.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed flow meter stuck and not operating properly. Corrected during inspection by pool operator.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed no ventilation in chemical storage room. Observed water on floor of chemical storage room.
#27 · Equipment room: filter backwash discharged through an air gap −2
Observed no air gap on back wash discharge.
#33 · Dressing and sanitary facilities: hose bibbs and floor drains provided −2
Observed no hose bibs in bathrooms.

View this inspection on the county portal ›

Jun 8, 2017 16 demerits · 6 violations
Inspector comments: EHS verified that information on current PDSC form to be correct at time of inspection. GC #17 Observed concrete chipped from pool deck between storage building & wall leading to men's restroom. ** Maintain deck in condition where there are no offsets > 1/2".
#2 · Water quality: disinfectant residual provided by −6
Observed chlorine @ 1.0ppm. ** Maintain minimum chlorine level of at least 2.0ppm. Chlorine level raised to 3.0 while EHS on-site.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
-- Equipment room/ chemical room has double doors that have a vent in the bottom of each side; however, the equipment room/ chemical room does not have any natural cross draft ventilation or forced air ventilation. ** Provide proper ventilation. See .2533(e) & .2534(3) -- Equipment room/ (chemical room) floor wet under wading pool filtration system due water leaking from filter drain plug area (?) & from leak at pump (pipe seal?). ** Resolve. Keep equipment room/ chemical room dry.
#26 · Equipment room: valves and pipes identified by color codes or labels −2
Filtration system piping not identified (i.e. main drain line, skimmer line, etc.). ** Identify piping by labels or color codes.
#27 · Equipment room: filter backwash discharged through an air gap −2
Backwash water discharges into storm drain at far right corner of parking lot (lot located to right side of the clubhouse & pool). ** Backwash water shall be discharged through a suitable air gap. See .2513 (b)
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Women' shower has leak @ "elbow" plumbing joint before shower head. ** Resolve.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
Hose bib located in equipment room/ chemical room has no back flow protection. ** Install vacuum breaker on hose bib.

View this inspection on the county portal ›

May 5, 2016 6 demerits · 1 violation
Inspector comments: NOTE: PDSC form needs updated to show new pump info. Pump model: Haywood Super Pump SP2607X10
#3 · Water quality: pool water pH −6
pH was 6.9 at beginingof inspection. pH corrected to 7.3 during inspection.

View this inspection on the county portal ›

Jul 13, 2015 32 demerits · 9 violations
Inspector comments: #27 Backwash line in equipment room has no air gap & unable to determine if exterior discharge point w/air gap. Intent to Suspend Issued for #5, #8 (missing weir) & #17.
#2 · Water quality: disinfectant residual provided by −6
Cl @ .6ppm. ** Maintain at least 2.0ppm. Cl raised to 6.0 ppm.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Record form does not include daily main drain checks. Weekly total alkalinity & cyanuric acid levels not being recorded. **Maintain complete records. (ITS)
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Sediment/soil on wading pool floor. ** Remove sediment.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Skimmer interior ring chipped. **Replace if possible. Missing 1 (of 1) weir. ** Install. (ITS)
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Major deck damage @ skimmer skimmer and expansion joint has missing caulk. ** Correct. (ITS) Basket of pool toys at pool edge. 2 chairs 3' from wading pool edge. ** Maintain 4' of clear walking space.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter float stuck. ** Rectify.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Equipment/chemical room has no cross or forced air ventilation. Equipment /chemical room floor wet @ wading pool circulation system. Leak @ chlorine line connection. ** Correct.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Womens' shower inoperable/handle missing. ** Repair. Large gap around one of the shower drains. ** Fill//close gap.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
No backflow prevention on hose bib (for hose). ** Install vacuum breaker.

View this inspection on the county portal ›

Jun 23, 2014 10 demerits · 3 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed missing weir. Needs Replacing.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed chain link greater than 2.25 inches.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
Observed no backflow preventer on threaded faucet.

View this inspection on the county portal ›