2demerits
REAVENCREST - WADING
7621 REAVENCREST PARK DRIVE, Charlotte, NC 28277
Seasonal Wading Pool · NC permit/State ID 2060510185
Latest result2 demerits
Last inspectedJun 3, 2026
Inspections on record13
On record sinceApr 28, 2014
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Apr 28, 2014Lower is betterJun 3, 2026
Inspections & violations
Jun 3, 2026 2 demerits · 1 violation
Inspector comments: Inspection completed with Chris G.
Night swimming not permitted.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(d) Pump room floor shall be kept dry and free of standing water. Observed standing water on pump room floor.
Apr 16, 2025 0 demerits · 0 violations
Inspector comments: Permit Conditions: Equalizer line plugged on wall and inside skimmer
No violations were recorded for this inspection.
Apr 11, 2024 14 demerits · 3 violations
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Observed initial pH of approximately 8.0. CDI - PIC corrected via adding acid to pool. Final pH of 7.8 observed
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. Observed 2 ground level club house door leading to entrance of pool deck not self latching and with no audible alarms. CDI by adding audible alarms to doors.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2519(k) Provide operational pressure gauge on filter. Observed filter pressure gauge no operating at time of inspection. Replace and maintain filters as needed.
Apr 20, 2023 6 demerits · 2 violations
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. Observed 2 ground level club house door leading to entrance of pool deck not self latching and with no audible alarms. CDI by adding audible alarms to doors
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
.2512(b) Water introduced into the pool, either directly or by the circulation system, shall be supplied through an air gap, anti-siphon vacuum breaker, or backflow preventer. No back flow preventer on hose bib under deck shower.
Apr 14, 2022 8 demerits · 2 violations
Inspector comments: Inspection conducted with Ryan Emerine.
NIGHT SWIMMING NOT PERMITTED.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed debris on floor and floating on surface of wading pool.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed debris inside skimmer.
Apr 7, 2021 4 demerits · 1 violation
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed debris in wading pool.
**.2537(14) Keep pool surface and pool floor free of debris.
May 6, 2020 0 demerits · 0 violations
No violations were recorded for this inspection.
Apr 22, 2019 10 demerits · 2 violations
Inspector comments: Observed correct pump from PDSC form(Pentair Whisperflo 3/4 HP) but replacement motor was 1 HP.
#4 · Water quality: water temperature of heated pool −6
observed pH at 5-6. Raised to 7.5
#13 · Pool maintenance: contrasting band on steps and benches −4
observed tile contrast band on step in wading pool to be greater than 1 inch to edge.
May 18, 2018 10 demerits · 2 violations
#2 · Water quality: disinfectant residual provided by −6
Upon beginning of inspection chlorine was 0 ppm. CDI chlorine rechecked at 8.0 ppm.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed debris floating in pool.
Apr 20, 2017 4 demerits · 1 violation
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed leaf debris covering drsin covers upon arrival. Removed so could view covers.
May 13, 2016 0 demerits · 0 violations
Inspector comments: Main Drain checked and matches PDSC form submittal.
Phone checked. 911 called and address and location verified.
No violations were recorded for this inspection.
Apr 17, 2015 0 demerits · 0 violations
No violations were recorded for this inspection.
Apr 28, 2014 8 demerits · 2 violations
#18 · Premises: lifeguards present or warning signs posted −4
Warning sign wording incomplete. Sign was replaced immediately.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flowmeter corroded and not operating. New, functional flowmeter was installed.
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “REAVENCREST - WADING” or State ID 2060510185). Inspection type (routine vs. follow-up) is not published in the county's data.