0demerits
VILLAGES AT ROSEDALE
9134 GREENHEATHER DR, Charlotte, NC 28078
Seasonal Wading Pool · NC permit/State ID 2060510213
Latest result0 demerits
Last inspectedApr 9, 2026
Inspections on record14
On record sinceApr 22, 2014
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Apr 22, 2014Lower is betterApr 9, 2026
Inspections & violations
Apr 9, 2026 0 demerits · 0 violations
Inspector comments: PERMIT RESTRICTION: FLOW RESTRICTION AT 55 GPM MAX DUE TO FILTER SIZE AND SKIMMER MAX FLOW. FLOW METER MUST REMAIN OPERABLE.
No violations were recorded for this inspection.
May 1, 2025 0 demerits · 0 violations
Inspector comments: No violations noted.
Not permitted for night swimming.
No violations were recorded for this inspection.
Jun 28, 2024 0 demerits · 0 violations
Inspector comments: Flow restriction @ 55 GPM
Flow meter must remain operable.
No violations were recorded for this inspection.
Jun 30, 2023 12 demerits · 3 violations
Inspector comments: Pre-permit inspection conducted with CPO Mikey Cook.
Issues from previous inspection corrected. Handle removed from Jandy valve installed after the pump, locking it in place. Flow meter reads 52 GPM after a backwash.
Permit issued
No Night Swimming
Paper permit will be available on our website https://health.mecknc.gov/envhealth/pools in 3-5 business days for your records.
#3 · Water quality: pool water pH −6
PH < 6.8. .2535(1) Maintain pH at 7.2 to 7.8. - Corrected to 7.2.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
No recent main drain checks, total alkalinity or cyanuric acid checks. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity. - Corrected. CPO took readings today and checked main drains.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Fan not functioning in pump room. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room.
Hose stored on top of valves by pump. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
Jun 29, 2023 18 demerits · 4 violations
Inspector comments: Inspection conducted with CPO Mikey Cook.
Note* Skimmer rated for 55 GPM. TR-60 filter rated for 63 GPM. Flow meter reading 69 GPM after a backwash.
Permit denied.
5)
6)
22)
There is a $100 re-inspection fee that must be paid prior to scheduling a re-inspection by calling our office (980-314-1620) and paying with a credit card.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
No recent main drain checks, total alkalinity or cyanuric acid checks. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity. - Pre-permit item.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
Flow meter reading 69 GPM after a backwash. PDSC form submitted said flow meter read 55 GPM. .2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance. - Pre-permit item.
#22 · Premises: emergency telephone provided −6
Emergency phone not functioning. .2530(f) Emergency phone shall remain operable. - Pre-permit item.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Fan not functioning in pump room. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room.
May 4, 2022 22 demerits · 6 violations
Inspector comments: Field confirmed: main drain piping 3" ; skimmer & return line piping 2"
#3 · Water quality: pool water pH −6
pH corrected to 7.8 during inspection
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Keep pool walls & floor free of debris
#22 · Premises: emergency telephone provided −6
Sign posted during inspection
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Natural cross or continuous forced ventilation required
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
Shower sign posted during inspection
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Shower heads installed during inspection; mirrors to be of shatterproof construction; soap not flowing from dispensers
Apr 30, 2021 4 demerits · 1 violation
Inspector comments: No Night Swimming
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Pool floor had leaf debris present. cleaned during inspection by staff.
May 26, 2020 4 demerits · 1 violation
Inspector comments: Night swimming not permitted.
PIC did not sign form due to new Covid protocols.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed two skimmer baskets full of debris. CDI-PO cleaned out.
Apr 29, 2019 14 demerits · 4 violations
#18 · Premises: lifeguards present or warning signs posted −4
.2530(c) Wading pools without a lifeguard shall have a sign posted "Warning - No Lifeguard on Duty" in 4" lettering. No sign was posted. PO posted proper sign.
#22 · Premises: emergency telephone provided −6
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Emergency phone sign not posted at phone. PO posted proper emergency phone sign.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room. Chemical storage room exhaust fan not operating.
.2533(g) Provide a hose bib with backflow prevention device within 50 ft. of the equipment room. Hose bibs in pump room need backflow prevention devices.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
.2626(h) Shower(s) shall be provided. Shower was being renovated at time of inspection, un-usable.
GENERAL COMMENT: Permit issued.
Apr 9, 2018 4 demerits · 1 violation
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518, .2537 Keep skimmer systems clean; Observed skimmer system with collected debris in need of cleaning.
Mar 30, 2017 0 demerits · 0 violations
Inspector comments: Looks Good
No violations were recorded for this inspection.
Apr 21, 2016 0 demerits · 0 violations
No violations were recorded for this inspection.
May 20, 2015 6 demerits · 2 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed some debris on the wading pool floor today.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed the chemical room fan not operating today.
Apr 22, 2014 0 demerits · 0 violations
Inspector comments: 22. Observed telephone sign numbers worn and city not listed. Corrected during inspection, new sign posted.Mr. Danny Richards present during inspection.**Permit Approved** Permit not valid until date listed on permit.
No violations were recorded for this inspection.
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “VILLAGES AT ROSEDALE” or State ID 2060510213). Inspection type (routine vs. follow-up) is not published in the county's data.