24demerits
WATERLYN ASSOCIATION
14305 LAKE CROSSING DR, Charlotte, NC 28278
Seasonal Wading Pool · NC permit/State ID 2060510231
Latest result24 demerits
Last inspectedAug 18, 2026
Inspections on record12
On record sinceJun 25, 2014
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Jun 25, 2014Lower is betterAug 18, 2026
Inspections & violations
Aug 18, 2026 24 demerits · 6 violations
Inspector comments: Pool issued for no night swimming. IFPR complete at time of visit. Play structure and slide removed. Posts remain in place and secure. New plaster and new drain covers. PDSC form approved.
Permit Restriction: Flow meter must remain operable. Flow required at 44 gpm to 80 gpm to meet turnover and flow restriction of the number of returns.
Brandon Vaughn present during the inspection.
Variable speed pump installed.
Gallon size of pool obtained while onsite, 5,285 gallons with turnover at 44 gpm.
3" md, skimmer and return lines.
Pentair TR140C filter
(2) Hayward SP1082 skimmers at 55 gpm with EQ lines disabled.
(4) returns - limiter.
Permit Restriction set on above.
#2 · Water quality: disinfectant residual provided by −6
Chlorine at 0.8 ppm. Corrected to 2.0 ppm during the inspection through feeder.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
No log book. Pool has not opened since 2024. Provide log book to maintain record keeping - chlorine, pH and main drain checks daily and cyanuric acid/total alkalinity weekly. Operator made phone call while onsite to get log book for site.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Windows into restrooms not limited. Corrected during the inspection.
Fence post at side entry gate not secure. When pushed upon, stays in place. Operator made phone call and will have repaired by end of day. Fence still secure.
Gates with >3" underneath. Multiple parts of barrier with 3" or greater underneath. Maintain 2" or less. Pool built 9/1/2006. Repair gate to 2" or less on both gates prior to 2027 operating permit.
<45" between horizontals on wading pool fence and main fence. Maintain at 45" or greater between horizontals.
#22 · Premises: emergency telephone provided −6
Location of emergency phone not visible from pool deck. Location written on pool rules sign during the inspection.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Vacuum line pipe and cleaning supplies in pump room, blocking access to equipment/pumps. Maintain 3 ft. clearance around equipment in all locations.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Hot water >113 F in restrooms. Maintain at 110 F or below.
May 2, 2024 0 demerits · 0 violations
Inspector comments: Inspection conducted with Mike Sudol.
No violations were recorded for this inspection.
May 9, 2023 0 demerits · 0 violations
Inspector comments: No violations.
No violations were recorded for this inspection.
Apr 12, 2022 4 demerits · 1 violation
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
slight floating debris in skimmers, removed during inspection
Apr 28, 2021 0 demerits · 0 violations
Inspector comments: No violations noted
No violations were recorded for this inspection.
May 8, 2020 4 demerits · 1 violation
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed debris in skimmer baskets.
Apr 15, 2019 10 demerits · 2 violations
Inspector comments: Night swimming is not permitted. Ensure permit remains visible at all times.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Initial check, pH at 7.0. CPO- able to correct to 7.2 during inspection. Note that correction levels very close, continue to monitor as required to ensure approved range for pH.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Debris on the bottom and floating in water throughout. Cleaning is needed.
May 24, 2018 0 demerits · 0 violations
No violations were recorded for this inspection.
Jun 20, 2017 2 demerits · 1 violation
#27 · Equipment room: filter backwash discharged through an air gap −2
No air gap for backwash pipe. Provide an air gap for backwash pipe.
Apr 21, 2016 8 demerits · 3 violations
Inspector comments: Note: Returned to site @ ~3:30pm to verify that styrofoam tubing has been placed over all wading pool feature projections. Protective covers have been secured with large cable ties. Check daily & maintain to insure safety.
WADING POOL PERMIT CAN BE ISSUED.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Sand/ debris on wading pool floor. Pollen/ soil visible in slide tunnel. ** Clean.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
All toilets & urinal are dirty. ** Clean thoroughly.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
No backflow protection on hose bib in women's restroom or on hose bib on pool deck (by showers). ** Install vacuum breakers.
Apr 24, 2015 8 demerits · 3 violations
Inspector comments: VGB. paperwork incorrect for feature. Currently have Waterway drain covers. Resubmit PDSC form for approval. Permit will not be issued until PDSC form received and approved.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter not operable. Placed on vertical line so not giving reading. Corrected during the inspection.
#26 · Equipment room: valves and pipes identified by color codes or labels −2
Piping not clearly identified. Clearly identify with color codes or labels.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Water >114 F in restrooms. Maintain at 110 F or below. Damaged countertop in restrooms. Keep in good repair. No paper towels and some toilets without toilet paper in restrooms. Provide soap, paper towels, and toilet paper.
Jun 25, 2014 6 demerits · 2 violations
Inspector comments: Pool permit not posted at the pool today. Permit must be posted so that it is visible. Permit may be obtained at meckpools.charmeck.org.General comment: 27. No sight glass on backwash lines. Provide
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter is installed but not operational. Repair flow meter.
#26 · Equipment room: valves and pipes identified by color codes or labels −2
Directional lines not labeled on equipment. Label equipment lines per rule.
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “WATERLYN ASSOCIATION” or State ID 2060510231). Inspection type (routine vs. follow-up) is not published in the county's data.