‹ Back to search

4demerits

THORNHILL MEMBERS CLUB

6501 ELMSTONE DR, Charlotte, NC 28277
Seasonal Wading Pool · NC permit/State ID 2060510240
Latest result4 demerits
Last inspectedApr 30, 2026
Inspections on record13
On record sinceMay 15, 2014

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

0816 May 15, 2014: 4May 1, 2015: 12Apr 28, 2016: 6May 18, 2017: 6Apr 25, 2018: 16Apr 17, 2019: 10Apr 23, 2020: 0May 14, 2021: 0May 17, 2022: 14May 11, 2023: 0Apr 24, 2024: 0May 8, 2025: 8Apr 30, 2026: 4
May 15, 2014Lower is betterApr 30, 2026

Inspections & violations

Apr 30, 2026 4 demerits · 1 violation
Inspector comments: EHS walked with Brandon V.. No night swimming. Permit granted. No restrictions . Spoke with Hope M, made aware there are only 2 skimmers at pool, forms shows pool having 3. There are no equalizer lines.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed pool floors with visible debris

View this inspection on the county portal ›

May 8, 2025 8 demerits · 2 violations
Inspector comments: -PDSC verified -No night swimming at wading pool -Wading pool entry gate swinging towards pool not out of compliance due to pre-2010 construction.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed leaf litter on sides and floor of wading pool. View of bottom and main drains is not obscured.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed multiple skimmer baskets with leaf litter and debris. Corrected- CPO empties skimmer baskets and clear debris.

View this inspection on the county portal ›

Apr 24, 2024 0 demerits · 0 violations
Inspector comments: No demerits taken

No violations were recorded for this inspection.

View this inspection on the county portal ›

May 11, 2023 0 demerits · 0 violations
Inspector comments: No demerits taken Night swimming is not approved.

No violations were recorded for this inspection.

View this inspection on the county portal ›

May 17, 2022 14 demerits · 3 violations
Inspector comments: Inspection conducted with Ryan Emerine present.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Observed pH of 7.1. Corrected to 7.4 during inspection.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. Observed 1 of 2 skimmer baskets missing it’s weir. New weir placed during inspection.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. Observed trip hazard at 0 ft depth marker tile. Repaired during inspection.

View this inspection on the county portal ›

May 14, 2021 0 demerits · 0 violations
Inspector comments: Permit Issued.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Apr 23, 2020 0 demerits · 0 violations
Inspector comments: NO VIOLATIONS NOTED. THE EQ LINE COVERS FOR THIS POOL EXPIRE APRIL 2021. THE POOL HAS ONE AQUASTAR 6HP EQ LINE COVER. AQUASTAR HAS CHANGED THE CERTIFIED FLOW RATE FOR THESE COVERS TO 92GPM. WHEN THE CURRENT COVERS EXPIRE, NEW COVERS MUST BE RATED FOR THE REQUIRED FLOW RATE OF THE CIRCULATION SYSTEM. THE MAIN DRAINS WILL ALSO EXPIRE APRIL 2021 AND WILL REQUIRE REPLACEMENT. WHEN THESE ITEMS ARE REPLACED, PDSC PAPERWORK WILL HAVE TO BE SUBMITTED TO THE HEALTH DEPARTMENT FOR APPROVAL. POOL IS NOT APPROVED FOR NIGHT SWIMMING. IF NIGHT SWIMMING IS DESIRED, A NIGHT SWIMMING EVALUATION MUST BE PERFORMED. CONTACT C. ELMORE AT 704-507-6814 FOR THIS EVALUATION IF NIGHT SWIMMING IS DESIRED. STICKER ISSUED. POOL IS NOT APPROVED FOR NIGHT SWIMMING. IF NIGHT SWIMMING IS DESIRED, A NIGHT SWIMMING EVALUATION MUST BE PERFORMED. CONTACT C. ELMORE AT 704-507-6814 FOR THIS EVALUATION IF NIGHT SWIMMING IS DESIRED. “issuance of a permit by this department does not negate closure required by Executive Order No. 120 or subsequent Orders in effect unless such Orders are rescinded or superseded by another applicable Order.” NO SIGNATURE WAS OBTAINED DUE TO COVID-19 SOCIAL DISTANCING

No violations were recorded for this inspection.

View this inspection on the county portal ›

Apr 17, 2019 10 demerits · 2 violations
#3 · Water quality: pool water pH −6
Observed the pH at 6.9. Corrected- Now 7.2. .2535(1) Maintain pH at 7.2 to 7.8.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed debris in the bottom of the pool. Clean. .2537(14) Keep pool surface and pool floor free of debris. NO Night swimming. Report emailed to Katie Buttcher.

View this inspection on the county portal ›

Apr 25, 2018 16 demerits · 3 violations
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. At start of inspection pH measured 7.0. Corrected to 7.4 by end of inspection.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Keep skimmers clean. Debris in skimmers. CDI- cleaned while on site.
#22 · Premises: emergency telephone provided −6
.2530(a) Provide signage with location of emergency phone if not visible from all areas inside pool enclosure. Had Katie Buttcher post directional sign indicating location of emergency phone located inside restroom enclosure.

View this inspection on the county portal ›

May 18, 2017 6 demerits · 1 violation
#3 · Water quality: pool water pH −6
Observed pH reading 8.3. CDI - pH read 7.4.

View this inspection on the county portal ›

Apr 28, 2016 6 demerits · 2 violations
Inspector comments: Wading pool PDSCPump: Pentair Challenger CHII-NI-IF 1.0 HPMain Drain cover: Aquastar R12MF101Equalizer Covers: Aquastar wall-6HP101; floor Aquastar-R8MWading feature PDSCPump: Pentair Challenger CHII-N!-IF 1.0 HPMain Drain cover: Aquastar R12MF101
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed pool gate not self-closing (bent hinge). Keep padlocked closed until repaired.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
Observed mirrors in bathroom not shatterproof.

View this inspection on the county portal ›

May 1, 2015 12 demerits · 3 violations
#3 · Water quality: pool water pH −6
pH measured 6.8 at start of inspection. Corrected by end of inspection to 7.3.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Floor of wading pool covered in old leaves.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.Equipment room has two passive vents in door but they are not located on opposite sides of the room.

View this inspection on the county portal ›

May 15, 2014 4 demerits · 1 violation
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed gate to main pool deck not self closing. Corrected onsite.

View this inspection on the county portal ›

Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “THORNHILL MEMBERS CLUB” or State ID 2060510240). Inspection type (routine vs. follow-up) is not published in the county's data.