4demerits
CAROLINA CROSSING
10410 STOKESHILL CT, Pineville, NC 28134
Seasonal Spa · NC permit/State ID 2060520137
Latest result4 demerits
Last inspectedApr 14, 2026
Inspections on record13
On record sinceApr 22, 2014
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Apr 22, 2014Lower is betterApr 14, 2026
Inspections & violations
Apr 14, 2026 4 demerits · 1 violation
Inspector comments: Spa heater in disrepair. Operator stated facility does not plan on repairing heater. EHS observed power to heater and gas line disconnected during inspection. EHS advised to email meckpools@mecknc.gov if/when heater is repaired.
EHS advised operator to keep spa closed until pool has passed permitting.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(b) Horizontals shall not be located less than 45" in height. EHS observed horizontals less than 45” in between.Pool/fence is pre 2010.
Apr 29, 2025 4 demerits · 1 violation
Inspector comments: Heater for spa not working will not be replaced/fixed during 2025 season.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(b) Horizontals shall not be located less than 45" in height. Pre-2010 construction. Brick ledge of barrier building 34” from ground to top of ledge.
Apr 16, 2024 0 demerits · 0 violations
Inspector comments: Heater was not on at time of inspection.
No demerits taken.
No violations were recorded for this inspection.
Apr 28, 2023 12 demerits · 3 violations
Inspector comments: David Shulte present during inspection.
Contrasting color bands on spa steps worn in some areas.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Debris on pool floor.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed cleaning needing to be done inside skimmers.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(b) Horizontals shall not be located less than 45" in height. Pre-2010 construction. Barrier brick wall ledge 34” from ground to top of ledge, adjacent to fence.
Apr 19, 2022 0 demerits · 0 violations
Inspector comments: David Schult present during inspection. No violations observed at this time.
No violations were recorded for this inspection.
Apr 6, 2021 12 demerits · 2 violations
#2 · Water quality: disinfectant residual provided by −6
.2535(4) Maintain chlorine at least 1.0 ppm. Observed chlorine at 0.4. PCO corrected concentration. Spa reading 1.5 ppm Chlorine by end of permitting.
#22 · Premises: emergency telephone provided −6
.2530(f) Emergency phone shall remain operable. Observed emergency phone not ringing when EHS calls back posted number. EHS picked up phone and can hear talking through the other end. Key to adjust ringer on phone was stuck. PCO replaced phone during permitting. Phone rang when EHS called number posted.
May 12, 2020 10 demerits · 2 violations
Inspector comments: No signature needed due to COVID-19 guidelines.
Permit Conditions:
“Issuance of a permit by this department does not negate closure required by Executive Order No. 138 or subsequent Orders in effect unless such Orders are rescinded or superseded by another applicable Order.”
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Observed pH at 7.0. Corrected during inspection to pH 7.4.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed cleaning needing to be done inside skimmers.
Apr 24, 2019 4 demerits · 1 violation
Inspector comments: Chemical reagents in testing kit have an expiration date of 8/2019. Timer for spa was checked today, but per CPO Brandon Vaughn gas is not on and he is not certain if owners will turn on for the summer.
Ensure that permit remains visible. Night swimming is not permitted at this pool.
** CPO unable to to sign due to set of afternoon appointments conflicts.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing, self-latching. . Side gate to the left of the main entry of the pool not self closing. CDI- CPO was able to remove some landscaping and adjust gate to allow it to self close. Gate does self latch.
Apr 10, 2018 8 demerits · 2 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed minor debris on pool floor. Make sure to keep clean.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed clogged flowmeter. CDI Operator was able to fix. Make sure to keep in good repair.
Apr 25, 2017 22 demerits · 4 violations
Inspector comments: This is not a pool permit. PDCS form includes eq line covers but eq lines have been plugged. New PDSC form must be submitted and approved by MCHD before permit issued. Permit will be available within 2-3 business days after PDSC form has been approved at meckpools.charmeck.org
#1 · Water quality: water clear enough to clearly see bottom of pool and pool drain −6
Observed chlorine greater than 10ppm. CDI, operator adjusted chlorine to 8.0 while on-site.
#3 · Water quality: pool water pH −6
Observed ph at 6.9. CDI, operator adjusted ph to 7.3 while on-site.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
EQ lines have been plugged. PDSC form not indiacte such. Permit will not be issued until updated PDSC form submitted and approved by Mecklenburg County Health Department.
#14 · Pool maintenance: spa timer working properly −4
Observed spa timer taking 22 minutes. CDI, operator adjusted spa timer to correct time while on-site.
Apr 22, 2016 6 demerits · 1 violation
Inspector comments: #4 Gen Comment: Heater igniter was broken. Needed to be replaced.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Ring buoy rope was fraying. Buoy was replaced and corrected during inspection.
May 1, 2015 4 demerits · 2 violations
Inspector comments: #26 Main drain & skimmer pipes not labeled.
** Corrected during inspection.
SPA PERMIT CAN BE ISSUED.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Forced air vent in equipment room runs off of light switch. ** Fan should run continuously.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
Sheet rock damage in both restrooms. ** Repair.
Apr 22, 2014 0 demerits · 0 violations
No violations were recorded for this inspection.