12demerits

DOUBLETREE HOTEL

2600 YORKMONT RD, Charlotte, NC 28208
Year-Round Swimming Pool · NC permit/State ID 2060530047
Latest result12 demerits
Last inspectedMay 22, 2026
Inspections on record23
On record sinceAug 12, 2013

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

01632 Aug 12, 2013: 26May 22, 2014: 8Jun 3, 2015: 12Oct 16, 2015: 20Jun 20, 2016: 26Oct 20, 2016: 22Jun 23, 2017: 24Apr 4, 2018: 12Oct 15, 2018: 28Mar 12, 2019: 26Sep 24, 2019: 22Feb 18, 2020: 12Aug 11, 2020: 16Jan 28, 2021: 16Aug 9, 2021: 32Jan 19, 2022: 22Aug 31, 2022: 16Mar 1, 2023: 18Aug 16, 2023: 14Mar 25, 2024: 12Oct 8, 2024: 4Jul 29, 2025: 2May 22, 2026: 12
Aug 12, 2013Lower is betterMay 22, 2026

Inspections & violations

May 22, 2026 12 demerits · 3 violations
Inspector comments: Conducted inspection with CPO. Pool returned to A status and may reopen; Pump flow must be at least 43gpm for turnover and cannot exceed 74gpm for filter limitation. Flow meter must remain operational. NIGHT SWIMMING RENEWAL DUE 2026 - NIGHT SWIMMING APPROVED WITH SITE VISIT VERIFICATION MADE 3/24/2023 Const. Date: 11/1/1989 Rope Length: 18'
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. One out of two weirs missing. Replace. No permit action.
#22 · Premises: emergency telephone provided −6
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Signage missing and posted callback number within phone box incorrect. Operator corrected during inspection. No permit action.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
No chemical storage room. .2534(1) Chemical storage room shall be weatherproof with a minimum ceiling height of 7 ft.

View this inspection on the county portal ›

Jul 29, 2025 2 demerits · 1 violation
Inspector comments: Observed gap around equalizer covers, recommend filling in gap. Main drain and equalizer covers expire January 13, 2026. Pool must close on that date. If new covers are installed the pool must remain closed until the PDSC form has been approved. Contact Chris Sells with questions at 704 576 8678
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
No chemical storage room. .2534(1) Chemical storage room shall be weatherproof with a minimum ceiling height of 7 ft.

View this inspection on the county portal ›

Oct 8, 2024 4 demerits · 2 violations
Inspector comments: Conducted inspection with James Durham. Pool remains in good standing and on A status.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Chemicals stored in pump room. Items around equipment and piping. Pool built '89. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. Dry chemicals stored directly on floor.
#27 · Equipment room: filter backwash discharged through an air gap −2
No air gap at pool backwash. Pool built 1989. .2513(b) Filter backwash shall be discharged through an air gap.

View this inspection on the county portal ›

Mar 25, 2024 12 demerits · 4 violations
Inspector comments: Conducted inspection with Andy Thomas. Items corrected by end of inspection.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(10) Provide test kit capable of measuring disinfectant level, cyanuric acid and total alkalinity. Some test kit reagents expired. CPO replacing kit. No permit action.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Battery dead in alarm for ground levels doors, not self-latching or alarmed onto pool deck. .2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. Operator replaced battery and corrected doors to have audible alarm. No permit action.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Chemicals stored in pump room. Items around equipment and piping. Pool built '89. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. Dry chemicals stored directly on floor.
#27 · Equipment room: filter backwash discharged through an air gap −2
No air gap at pool backwash. Pool built 1989. .2513(b) Filter backwash shall be discharged through an air gap.

View this inspection on the county portal ›

Aug 16, 2023 14 demerits · 4 violations
Inspector comments: Inspection conducted with operator Andy. All non-compliant items corrected during inspection. Note: CYA readings approaching 100ppm. Correct to ensure proper pool chemistry and continuation of effective disinfection. Night swimming remains approved.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Accumulated debris in skimmers. Cleaned during inspection.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Ring buoy rope exceeding 19’. Operator corrected to required 18’.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Chemicals stored in pump room. Items around equipment and piping. Pool built '89. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. Dry chemicals stored directly on floor. .2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor.
#27 · Equipment room: filter backwash discharged through an air gap −2
No air gap at pool backwash. Pool built 1989. .2513(b) Filter backwash shall be discharged through an air gap.

View this inspection on the county portal ›

Mar 1, 2023 18 demerits · 5 violations
Inspector comments: Inspection conducted with operator Andy Thomas. Intent to suspend permit issued today due to emergency phone not receiving call back to office line. Call Hope McIntosh at 980-229-7549 once phone line has been corrected. Night swimming remains approved. Night time photos verify that light remains sufficient for night swimming. No changes in lighting. Night swim verified for additional 3 years.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Skimmer with accumulated debris. Cleaned during inspection
#22 · Premises: emergency telephone provided −6
.2530 - Emergency phone line has been modified. Phone calls out to 911 dispatch and correct routing of address and phone number have been verified. Upon call back, phone number now goes to menu and office staff can not answer the line. Phone number when called by EHS goes to to hotel menu. *Permit item
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Flow meter not operating. Corrected during inspection.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Chemicals stored in pump room. Items around equipment and piping. Pool built '89. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. Dry chemicals stored directly on floor. .2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor.
#27 · Equipment room: filter backwash discharged through an air gap −2
No air gap at pool backwash. Pool built 1989. .2513(b) Filter backwash shall be discharged through an air gap.

View this inspection on the county portal ›

Aug 31, 2022 16 demerits · 5 violations
Inspector comments: One pool light out, on side without main drains. Operator having repaired 9/3 and sending verification to Marie Daley at 704-507-6806 No Night Swimming until corrected
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Ladder by 4 1/2 FT loose. .2521 Install ladders per manufacturer instructions Keep tight and in good repair.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Gates not self-latching at time of inspection. .2537(b) All gates and doors shall be self-closing, self-latching. Operator adjusted to self-close, self-latch.
#22 · Premises: emergency telephone provided −6
When 911 is dialed front desk could not locate emergency call location to route. .2530(f) Emergency notification systems must provide 24 hr. monitoring, be capable of routing calls to 911, and be able to electronically transfer Automatic Number and Locator Identification for the phone. CPO helped with alarm and educated staff on hitting “alarm” then “911 location” for outgoing emergency call to locate emergency call location (pool, ext 5999). Corrected through education.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Chemicals stored in pump room. Items around equipment and piping. Pool built '89. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
#27 · Equipment room: filter backwash discharged through an air gap −2
No air gap at pool backwash. Pool built 1989. .2513(b) Filter backwash shall be discharged through an air gap.

View this inspection on the county portal ›

Jan 19, 2022 22 demerits · 8 violations
Inspector comments: Intent to Suspend (ITS) for records and pool floor. Contact Marie Daley at 704-507-6806 when in compliance to lift ITS. Changed to "W" ITS status. Verified exterior lighting, need pool lights verified for "Night Swimming". Sent to Marie Daley. Inspection with Leonard Gibson No signature due to COVID Emergency phone: Extension 5999 is posted at pool. Front desk staff was not aware of how to verify location of phone at time of inspection. Ensure staff is trained to identify location of emergency call in case of emergency. Staff figured out how to identify, noted at front desk for other staff and corrected.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Records missing last week of readings. No maintenance recorded for the month. Readings not matching current water quality. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. *Permit item. Will return to verify records.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Pool floor observed with debris and leaves. .2537(14) Keep pool surface and pool floor free of debris. *Permit item.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Debris in skimmer baskets at time of inspection. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Operator cleaned and corrected.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Ladder by 4 1/2 FT loose. .2521 Install ladders per manufacturer instructions Keep tight and in good repair.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Chemicals stored in pump room. Items around equipment and piping. Pool built '89. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
#27 · Equipment room: filter backwash discharged through an air gap −2
No air gap at pool backwash. Pool built 1989. .2513(b) Filter backwash shall be discharged through an air gap.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
One shower leaking and shower holder broken outside. .2526(h) Shower(s) shall be provided. Keep in good repair.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
No paper towels in men's restroom at time of inspection. Provide hand drying.

View this inspection on the county portal ›

Aug 9, 2021 32 demerits · 9 violations
Inspector comments: Suspended permit for water quality and skimmer equalizer covers. Contact Marie Daley at 704-507-6806 when corrected to lift suspension. Pool MUST REMAIN CLOSED until suspension lifted by Health Dept. Changed to "E" Immediate Suspension status. Permit items to be verified at return visit: Cracked decking, cyanuric acid checks and loose ladder. Will check lighting at return visit. Inspection with Leonard Gibson and Rob Feeney No signature due to COVID
#3 · Water quality: pool water pH −6
pH 6.8 at time of inspection. .2535(1) Maintain pH at 7.2 to 7.8. *Immediate suspension item. Contact Marie Daley at 704-507-6806 when corrected to lift suspension. Pool MUST REMAIN CLOSED until suspension lifted by Health Dept
#5 · Water quality: daily written records of water quality and test kit kept on site −4
No cyaniric acid checks at time of inspecction. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. *Permit item
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
Skimmer equalizer cover detached from wall at time of inspection. Other skimmer equalizer line popped off wall during inspection. .2539(d) All drain covers shall be kept in good condition. Missing, broken, or cracked fittings shall be replaced or reattached before the pool should be used. *Immediate suspension item. Contact Marie Daley at 704-507-6806 when corrected to lift suspension. Pool MUST REMAIN CLOSED until suspension lifted by Health Dept
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Some debris in skimmer baskets at time of inspection. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Operator cleaned and corrected.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Ladder by 4 1/2 FT loose. .2521 Install ladders per manufacturer instructions Keep tight and in good repair.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Cracked piece of deck by ladder at 4 1/2 FT side, greater than 1/2" offset. .2537(2) Decks shall be kept in good repair. .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. *Permit item
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Chemicals stored in pump room. Items around equipment and piping. Pool built '89. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
#27 · Equipment room: filter backwash discharged through an air gap −2
No air gap at pool backwash. Pool built 1989. .2513(b) Filter backwash shall be discharged through an air gap.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Women's restroom toilet in need of cleaning at time of inspection. Soap dispenser not working in women's restroom at time of inspection. .2526(m) Keep restrooms and fixtures clean and in good repair.

View this inspection on the county portal ›

Jan 28, 2021 16 demerits · 5 violations
Inspector comments: Verified PDSC information 2 Aquastar WAV9WR101, 2 Aquastar A10RCFR Checked lighting at time of visit for Night Swimming documentation. Pool not heated. Automatic feeder not programmed and not automatically operating at time of visit. Feeder still shut off with pump. If work is done, ensure automatic chlorine and acid feeder shuts off with pump. Per Executive Order, post all COVID signage No signature due to COVID Inspection with Andy Thomas and Aimee Lee Report to Andy Thomas
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Becket on ring buoy observed detached at time of inspection, voiding US Coast Guard approval. .2530(a) Provide USCG approved ring buoy. Operator replaced buoy and corrected.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
One set of table and chairs within 6' of pool at time of inspection. .2522(a) Provide 6 ft of clear walking space around the pool at all times. Operator moved and corrected.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Chemicals stored in pump room. Items around equipment and piping. Pool built '89. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
#27 · Equipment room: filter backwash discharged through an air gap −2
No air gap at pool backwash. .2513(b) Filter backwash shall be discharged through an air gap.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
Showers turned off at time of inspection, due to cold weather. .2526(h) Shower(s) shall be provided.

View this inspection on the county portal ›

Aug 11, 2020 16 demerits · 6 violations
Inspector comments: ITS for gates, ladder and inlet fitting. **Note: Drain covers expire 2021. When Aquastar 6HPs are replaced (expires Feb 2021) flow rating has been reduced to 92 gpm on walls (6HPHAs) and may not meet standard for suction hazard prevention according to max flow rating for pump. Skimmer equalizers will need to be plugged according to state guidance or a different cover found that meets/exceeds standard for pump curve. Main drains expire June 2021. Inspection with: Andy Thomas Report to: Andy.Thomas@hilton.com No signature due to COVID-19
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Ladders removed from side of pool for repair at time of inspection. .2521(a) Steps or ladders shall be provided every 75 ft along the shallow area perimeter. *ITS items.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Gates not self-latching at ime of inspection. Battery dead in alarm for ground levels doors, not self-latching or alarmed onto pool deck. .2537(b) All gates and doors shall be self-closing, self-latching. .2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. Operator replaced batter and corrected doors to have audible alarm. *ITS item
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed missing inlet fittings at time of inspection. .2518(i) Provide inlet fittings in good repair. *ITS item.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Chemicals stored in pump room. Items around equipment and piping. Pool built '89. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
#27 · Equipment room: filter backwash discharged through an air gap −2
No air gap at backwash line to pit. .2513(b) Filter backwash shall be discharged through an air gap.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Soap in men's restroom not dispensing at time of inspection. .2526(j) Provide soap and soap dispenser, no glass, at each sink. .2526(m) Keep restrooms and fixtures clean and in good repair. Per housekeeping, due to COVID-19, unable to get correct soap for dispenser and will work if multiple attempts are made. Suggested signage or repair of fixture to work upon use.

View this inspection on the county portal ›

Feb 18, 2020 12 demerits · 4 violations
Inspector comments: Showers off at time of inspection. **Note: Main drains expire February 2021. When Aquastar 6HPs are replaced (expires Feb 2021) flow rating has been reduced to 92 gpm on walls (6HPHAs) and may not meet standard for suction hazard prevention according to max flow rating for pump. Skimmer equalizers will need to be plugged according to state guidance or a different cover found that meets/exceeds standard for pump curve. Checked lights at time of inspection. Following up with operator regarding chages for Night Swimming.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
No cyaniric acid checks at time of inspecction. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Operator checked and recorded. Corrected.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
One inlet fitting coming off of threads on wall. .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. Operator adjusted. Corrected.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Chemicals stored in pump room. Items around equipment and piping. Pool built '89. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
#27 · Equipment room: filter backwash discharged through an air gap −2
No air gap at backwash line to pit. .2513(b) Filter backwash shall be discharged through an air gap.

View this inspection on the county portal ›

Sep 24, 2019 22 demerits · 7 violations
Inspector comments: Note - flow rating for 6HP covers have changed to 92 gpm and may not be compatible with pump when due for replacement.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Test kit with black residue on bottom of cyanuric acid test tube. Replace test kit as needed. .2535(10) Provide test kit capable of measuring disinfectant level, cyanuric acid and total alkalinity.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
One ladder closest to fitness area with rungs 9" to pool wall. Maintain 3" to 6" between wall and ladder rungs. Pool built 1989. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
One return missing fitting. Replace return fitting. .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Ring buoy rope at 16 ft. due to tie off. Corrected to 18 ft. during inspection. General Comment - Grab rope on ring buoy starting to degrade. Still usable. Replace within 30 days. A return visit will be made in 30 days to verify if documentation not provided.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
New chlorinator installed - CCH Endurance - located at entry to the pump room. Provide 3 ft. clearance around all equipment. Operator indicated that Leslie's Pools has already been contacted to move chlorinator. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
#26 · Equipment room: valves and pipes identified by color codes or labels −2
Some piping not labeled in pump room. .2518(d) Piping and valves shall be labeled with color codes or labels.
#27 · Equipment room: filter backwash discharged through an air gap −2
No air gap at backwash line to pit. Pit is half full of water. .2513(b) Filter backwash shall be discharged through an air gap.

View this inspection on the county portal ›

Mar 12, 2019 26 demerits · 7 violations
Inspector comments: Immediate Suspenison for pH. 30 Day ITS items skimmer baskets, pool floor, records and doors self-closing, self-latching or audible alarm. **Note: When Aquastar 6HPs are replaced (expires Feb 2021) flow rating has been reduced to 92 gpm on walls (6HPHAs) and may not meet standard for suction hazard prevention according to max flow rating for pump. Skimmer equalizers will need to be plugged according to state guidance or a different cover found that meets/exceeds standard for pump curve.
#3 · Water quality: pool water pH −6
pH 7.0 at time of inspection. .2535(1) Maintain pH at 7.2 to 7.8. Immediate Suspension item. Contact Marie Daley at 704-507-6806 when corrected to lift suspension. Posted 'Pool Closed' sign
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Records missing weekly CA checks. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. **30 Day Intent to Suspend (ITS) item.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Debris and leaves on pool floor at time of inspection. .2537(14) Keep pool surface and pool floor free of debris. **30 Day Intent to Suspend item.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Debris in skimmer baskets at time of inspection. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. **30 Day Intent to Suspend item.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Doors into gym area not self-latching at time of inspection. .2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. Screw detached from column, creating gap greater than 4". .2528(a) Provide no openings in fence and/or gate greater than 4"x4". **30 Day Intent to Suspend item.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
At time of inspection, chemicals stored in pump room. Less than 3' clearance around piping. Pool built 89. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
#26 · Equipment room: valves and pipes identified by color codes or labels −2
PVC piping replaced, no longer labeled in some areas. .2518(d) Piping and valves shall be labeled with color codes or labels.

View this inspection on the county portal ›

Oct 15, 2018 28 demerits · 7 violations
Inspector comments: 30 Day Intent to Suspend for records, gate self-closing, self-latching, acid/chlorine feeder stopping when pump off
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Records missing weekly TA and CA checks. **30 Day Intent to Suspend (ITS) item.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Some leaves and debris in skimmer basket. Operator cleaned. Corrected.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
.2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. One inlet fitting missing. Operator replaced. Corrected.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Buoy rope tangled. Keep accessible. Operator untangled and corrected.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing, self-latching. Front gate not self-latching at time of inspection. **30 Day Intent to Suspend item. Contact Marie Daley at 704-507-6806 when corrected to lift ITS.
#23 · Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 −4
.2535(6) Automatic chlorine and bromine feeder pumps shall be automatically prevented from operating when the circulation pump is not in operation. .2535 Automatic acid feeder shall be automatically prevented from operating when the circulation pump is not in operation. Feeder continued to operator when pump shut off. **30 Day Intent to Suspend item. Contact Marie Daley at 704-507-6806 when corrected to lift ITS.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
.2512(c) Over the rim fill spouts shall not protrude greater than two inches beyond the edge of the pool. Fill spout protruding approximately 7.5" past edge of pool.

View this inspection on the county portal ›

Apr 4, 2018 12 demerits · 3 violations
Inspector comments: PIC stated pool will be used for night swiming. Verification required. EHS will return to verify.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed build up of debris in skimmers. In need of cleaning. CDI, skimmers cleaned.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed speakers near fencing that were capable of being used as foot holds. CDI, operator had speakers removed.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed flow meter stuck, not working. Meter will be re-placed.

View this inspection on the county portal ›

Jun 23, 2017 24 demerits · 7 violations
Inspector comments: PDSC form verified during inspection to be incorrect: - The current form indicates that the filtration pump is a Sta-Rite model # P4R6E3-187/ 1HP w/ an Emerson 1HP replacement motor. No identification found on pump itself; however, Sta-Rite cover on lint basket and replacement motor is an Emerson 1 HP. The pump appears to be a Sta-Rite Max-E-Pro model # P6R6E3-206/ 1HP w/ a flow rate of ~104gpm. Note: EHS observed that the 2 main drain covers are Aquastar WAV9WR and that the 2 equalizer line covers are Aquastar 6HP which match that listed on the current PDSC form. ***A new PDSC form must be completed reflecting the correct pump information and this new form must receive final approval by K. Wilson (MCHD Sr. Env. Health Spec.).*** IMMEDIATE SUSPENSION ISSUED for #2 & #3.
#2 · Water quality: disinfectant residual provided by −6
Observed chlorine @ 0ppm. Pool disinfectant system currently being utilized is Hayward Saline Commercial Salt Chlorine Generator. ** Maintain chlorine level at a minimum of at least 1.0ppm. Chlorine level was not able to be raised while EHS on-site. Salt system itself must raise the chlorine level to the required level; otherwise, switching back to use of the erosion feeder that remains in place is an option available if salt system needs repair/ adjustment. Immediate Suspension issued.
#3 · Water quality: pool water pH −6
Observed pH @ 8.2. ** Maintain pH 7.2 - 7.8. An attempt was made to correct pH while EHS on-site; however, pH level dropped to 6.8. Immediate Suspension issued.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
One ladder 8" from pool wall (& the other 2.5" from pool wall). ** Maintain minimum of 3" & a maximum of 6".
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter float stuck. ** Keep flow meter operational.
#27 · Equipment room: filter backwash discharged through an air gap −2
Backwash pipe turns down into sump. ** Backwash water should discharge through a complete air gap.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Leak @ junction of one shower head fixture & column. ** Resolve. There is a combined total of 5 toilets in the men's and women's restrooms. EHS observed 2 toilets in the restrooms w/ waste present in bowls and another toilet stall door posted with an out of service sign; CPO/ engineer states that the sensor for automatic flush feature for this particular toilet needs to be replaced. ** Check sensors for all toilets and repair/ replace sensors if necessary.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
Over-the-rim fill spout extends ~7.5" beyond pool wall. ** Over-the -rim spout shall not protrude more than 2" beyond the edge of the pool.

View this inspection on the county portal ›

Oct 20, 2016 22 demerits · 7 violations
Inspector comments: #25 Portion of pool chemicals are being stored in new storage building that has 1 high vent at each end of the structure. ** Provide natural cross draft ventilation (1 vent high at end & the other vent low at the opposite end) or forced air ventilation. Note: Computer issues delayed CDP entry. EHS slow on field CDP entry.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Residue/ scum on pool wall tiles. ** Clean. Leaves on pool floor. ** Remove debris.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Corner broken off one skimmer lid. ** Replace lid. Accumulation of leaf debris & snakes (3) in skimmer baskets. ** Check skimmer baskets at least daily & empty. Corrected during inspection.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
One ladder 8" from pool wall (& the other 2.5" from pool wall). ** Maintain minimum of 3" & a maximum of 6".
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Some lounge chairs & table chair 5' from pool edge. ** Maintain 6' of clear walking space.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter float stuck. ** Keep operational.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Leak @ junction of one shower head fixture & column. ** Resolve.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
Over-the-rim fill spout extends ~7.5" beyond pool wall. ** Maximum is 2". Hose bib outside equipment/ chemical room has no back flow prevention device. ** Install vacuum breaker.

View this inspection on the county portal ›

Jun 20, 2016 26 demerits · 7 violations
Inspector comments: # 8 Corner of one skimmer lid is broken. ** Replace lid. Updated PDSC form faxed to the Meck. Co. Health Dept. while EHS on-site. INTENT TO SUSPEND issued for #18.
#3 · Water quality: pool water pH −6
Observed pH @ 8.2. ** Maintain 7.2 - 7.8. pH corrected to 7.6 while EHS on-site.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed residue on pool wall tiles. ** Clean. Observed pieces of shredded paper on pool floor. ** Vacuum.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
One ladder 8" from pool wall (& the other 2" - 2 1/2" from pool wall). ** Ladders should both be between 3" and 6" from pool wall.
#18 · Premises: lifeguards present or warning signs posted −4
-- NO LIFEGUARD ON DUTY sign missing the word "WARNING". See .2530 (c) -- Pool rules sign states "Children under 12 years of age must be accompanied by an adult." ** Sign should read "CHILDREN SOULD NOT USE THE SWIMMING POOL WITHOUT ADULT SUPERVISION". See .2530 (c). Lower case letters on sign 3/4" in height. ** All letters must be at least 1" in height . See .2530(c).
#22 · Premises: emergency telephone provided −6
Sign at emergency phone states that the "...phone direct dials 911...", when the caller must dial 911. ** Correct dialing instructions posted at emergency phone while EHS on-site.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Observed leak @ junction of one shower head fixture & column. ** Resolve. Men's hand-cap toilet is dirty. ** Clean.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
Over-the-rim spout extends ~7.5" beyond pool wall. ** Fill spout should not protrude more than 2" beyond edge of pool.

View this inspection on the county portal ›

Oct 16, 2015 20 demerits · 6 violations
Inspector comments: Immediate Suspension issued for #3.
#3 · Water quality: pool water pH −6
Observed pH @ 8.0. ** Maintain pH 7.2 to 7.8. Immediate Suspension issued.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Soil/ scum on pool wall tiles. ** Clean. Grout between pool coping & wall tiles black in areas. ** Clean & re-grout where needed. Some leaf debris on pool floor. ** Clean/ remove.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
One ladder ~9" from pool wall. ** Maintain between 3" and 6" between ladder & wall.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Coping cracked & chipped in various areas. ** Repair.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Portion of chemicals stored in old hot holding unit near dumpster. ** This unit does not meet chemical storage room requirements. See .2534.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Leak @ junction of one shower fixture & column. ** Repair. Handicap toilets need cleaning. (One toilet in women's restroom in disrepair. Posted Out of Service.)

View this inspection on the county portal ›

Jun 3, 2015 12 demerits · 4 violations
Inspector comments: 15 - General Comment - Grab rope on ring buoy beginning to fray from weather. Replace by 6/4/2015 otherwise Immediate Suspension will be issued. Permit not posted on pool deck. Post permit visible upon entrance to the pool. Intent to Suspend issued for door self-closing, self-latching.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
One ladder >6" from pool wall. Maintain between 3" and 6" between ladder rail and pool wall.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Door leading out on to pool deck from the fitness room must remain unlocked due to fire code per engineering. All glass in fitness room is tempered. Door into fitness room is key swipe but does not self-close, self-latch. Door must be made to self-close, self-latch. Intent to Suspend issued.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Some damage to pool coping. Keep in good repair.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Chemicals stored in metal storage bin with no ventilation or lighting. Height of ceiling does not meet requirements. Move to approved chemical storage area that meets code or to pump room.

View this inspection on the county portal ›

May 22, 2014 8 demerits · 3 violations
Inspector comments: #29 Observed leak @ 1 shower where fixture is secured to pool enclosure column. **Per CPO, already on schedule to resolve.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed ~8.5" clearance between 1 ladder & pool wall. **Clearance should not be more than 6" nor less than 3". See .2521(5)
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed cracks in pool coping. **Maintain coping in good repair.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Portion of chemicals stored in old food hot holding unit near dumpster. **This unit does not meet chemical storage room requirements. See .2534.

View this inspection on the county portal ›

Aug 12, 2013 26 demerits · 7 violations
Inspector comments: . #11 Observed approximately 9" clearance between one ladder & pool wall. **maximum should be 6".Immediate suspension issued - #2.Note: No water in restrooms @ start of inspection. Corrected while on-site.
#2 · Water quality: disinfectant residual provided by −6
Observed Cl @ 0ppm. **Maintain chlorine @ 1ppm minimum. IS issued.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Last cyanuric acid & total alkalinity readings July 17th. ** test & record weekly.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
Missing depth marker on pool wall @ end. **install.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed cracks near pool coping & deck. **repair.
#21 · Premises: pool and deck lighting provided at pools that operate at night −4
Pool wall light misaligned creating gap. **correct.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Portion of chemicals stored in old food hot holding unit near dumpster area; hole in bottom of unit. **This unit does not meet chemical storage room requirements. See. 2534.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Hot water in restrooms 124F. **maximum allowed is 110F.

View this inspection on the county portal ›