0demerits
SWIMMAC CAROLINA - LAP
9850 PROVIDENCE RD, Charlotte, NC 28277
Year-Round Swimming Pool · NC permit/State ID 2060530054
Latest result0 demerits
Last inspectedMay 26, 2026
Inspections on record26
On record sinceDec 4, 2013
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Dec 4, 2013Lower is betterMay 26, 2026
Inspections & violations
May 26, 2026 0 demerits · 0 violations
Inspector comments: Inspection conducted with Paul.
All items in compliance. Pool remains in good standing and on A status.
Permit Restriction: Double doors must remain permanently locked/latched or audible alarms installed. Paddock drain covers - Installed 9/1/2023. Provide yearly documentation for recertification of drains after 9/1/2033. Screw change required 9/1/2030. VARIANCE FROM LIFEGUARDS - LIFE GUARDS ARE REQUIRED AT ALL TIMES EXCEPT DURING COMPETITIVE SWIM TEAM PRACTICE COACHES WITH FIRST AID AND CPR/AED TRAINING MUST BE PRESENT ON THE POOL DECK AT ALL TIMES Required Lifeguard: YES Const. Date: 10/1/1990 Rope Length: 50'
No violations were recorded for this inspection.
Nov 17, 2025 0 demerits · 0 violations
Inspector comments: Inspection led by EHS Ariel under supervision of EHS Devon. All items in compliance. Pool remains in good standing and on A status.
Pump too old for spare pump basket.
EHS recommends new ring buoy rope for next inspection. Current ring buoy rope weakened but still operational.
Ladder handrails loose due to removal feature.
Permit Restriction: Double doors must remain permanently locked/latched or audible alarms installed. Paddock drain covers - Installed 9/1/2023. Provide yearly documentation for recertification of drains after 9/1/2033. Screw change required 9/1/2030.
VARIANCE FROM LIFEGUARDS - LIFE GUARDS ARE REQUIRED AT ALL TIMES EXCEPT DURING COMPETITIVE SWIM TEAM PRACTICE COACHES WITH FIRST AID AND CPR/AED TRAINING MUST BE PRESENT ON THE POOL DECK AT ALL TIMES
Required Lifeguard: YES
Const. Date: 10/1/1990
Rope Length: 50'
No violations were recorded for this inspection.
Apr 22, 2025 20 demerits · 6 violations
Inspector comments: 30 Day Intent to Suspend for doors onto pool deck self-closing, self-latching or alarmed, 8 foot clearance (fan) and replacing buoy rope and life guard tubes. Correct and contact Marie Daley at 704-507-6806 when in compliance to lift ITS.
“W” status
Inspection with Paul Rill
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
One buoy missing rope. Lifeguard tubes in disrepair. Allowing 30 days to replace buoy rope (50’ at least 1/4” in diameter) and 3 life guard tubes, due to having enough life saving equipment, but a need for replacement.
.2530(b) Two units of lifesaving equipment (or two lifeguards) must be provided for pools that exceed 3,000 sq. ft. surface area.
.2530(a) Provide USCG approved ring buoy. A rescue tube with lifeguard may be substituted for ring buoy.
*Permit item
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Multiple doors without either missing audible alarms or audible alarms not operable. .2528 (a) Ground level doors on to the pool deck shall self-close, self-latch or self-close with an audible alarm.
*Permit item
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Bleachers within 8’ of pool. Large fan within 8’ of pool.
.2522(a) Provide 8 ft of clear walking space around the pool at all times (>1600 sq. ft). This is indoor pool. Lack of severity does not warrant permit action at this time for bleacher. Discussed keeping maximum amount of space around pool at all times (This is about7 feet where bleachers are).
*Permit item-move large fan
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Chemicals in pump room. Door unlocked to pump room at time of inspection. Pool built 1990.
.2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
.2533(a) The equipment room door shall have a permanent lock and be kept locked when not in use by the pool operator.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Back restroom in need of cleaning.
.2526(m) Keep restrooms and fixtures clean and in good repair.
#32 · Dressing and sanitary facilities: floors smooth, slip-resistant, kept clean −2
Build-up of water on the women's restroom floor. Could not view men's due to usage at time of inspection. Ensure floor is kept clean and free of slip hazards.
.2526(c) Restroom floor shall be sloped to drain.
Sep 26, 2024 32 demerits · 10 violations
Inspector comments: Note: Can lights hanging from ceiling in women's restroom. Secure to ceiling.
Intent to Suspend issued for:
.2528 - repair all doors to self-close, self-latch or self-close with audible alarms; repair back door hinge to so door self-closes, self-latches
.2522 - clean deck so that all areas with algae are cleaned and no slip hazard
.2537 - provide portable vacuum or means to clean pool
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Total alkalinity not recorded in last week. Record weekly. All previous weeks with records.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Debris on pool floor. Operator stated that the vacuum was broken. Provide means to vacuum the pool. Intent to Suspend issued.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Some ladders not secure. Secure when in use.
Some diving platforms at deep end of the swimming pool without signage. .2517(e) Secure starting platforms from use by removal; covering; or signage and active supervision.
Ladders in shallow end of pool but greater than 75 ft between ladders. .2521(a) Steps or ladders shall be provided every 75 ft along the shallow area perimeter.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Multiple doors without either missing audible alarms or audible alarms not operable. All doors on to the pool deck shall self-close, self-latch or self-close with an audible alarm. Intent to Suspend issued.
Back door near restrooms missing hinge and does not self-close. Repair door to self-close, self-latch. Intent to Suspend issued.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Standing water on deck floor. Some areas with algae build-up. Eliminate build-up to eliminate slip hazard. Intent to Suspend issued.
#22 · Premises: emergency telephone provided −6
Phone signage inside door of the defibrillator. Moved to be posted so visible at the pool phone.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Leak in ceiling of pump room.
Operator not available to unlock chemical storage room. Two tanks of chlorine/acid stored outside of the chemical storage shed. Door unlocked to pump room. Keep chemicals stored in chemical storage room. Ensure pump room/chemical storage room are kept locked when not in use.
#27 · Equipment room: filter backwash discharged through an air gap −2
Could not view air gap for backwash pit. Goes through wall. Sight glass provided. Ensure air gap provided.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
No backflow prevention device on hose bib in pump room. Provide backflow prevention device.
#32 · Dressing and sanitary facilities: floors smooth, slip-resistant, kept clean −2
Build-up of water and build-up on the women's restroom floor. Could not view men's due to usage at time of inspection. Ensure floor is kept clean and free of slip hazards.
Mar 27, 2024 16 demerits · 4 violations
Inspector comments: POOL HAS BEEN ISSUED A 30 DAY I.T.S FOR LOG BOOK AND DEPTH MARKERS. DEADLINE IS 4/26/2024.
POOL WILL BE CLOSED IF ITEMS ARE NOT RESOLVED. 30 DAYS OF PROPERLY KEPT RECORDS WILL BE REQUIRED FOR REVIEW.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
.2535 (11) The pool operator shall inspect the pool at least daily and maintain written records.
Observed log book records not being properly kept. Records must be kept for every day the pool is open, including weekends and holidays. I.T.S. Issued.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
.2523(a) Provide depth markers on pool walls and pool deck next to the swimming pool.
.2523(c) Depth markers shall be 4 inches in height and of a contrasting color with the background, clearly visible.
.2523(c) Depth markers shall include the word "feet" or symbol "ft".
Observed numerous incomplete or missing depth markers. Correct the depth markers. I.T.S. Issued.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Lifesaving equipment should be conveniently located.
Observed body hook to be on the floor behind a large blue storage chest where it was hard to find and access. -CDI Item was moved.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
.2526(a) Post a shower sign visible upon entrance to the pool. Observed no shower sign posted. One was obtained and posted. CDI
Oct 2, 2023 28 demerits · 8 violations
Inspector comments: Pool Drain Safety Compliance (PDSC) has been disapproved by Katie Rudisill who has been working with Jeff Gaeckle. At time of visit, 4 Paddock drain covers installed in pool. Continue to work with health department and submit changes to pdsc@mecknc.gov for approval. Spoke with Tim Dutcher PEHS supervisor, who advised permit action will not be taken at this time. Failure to gain approval on this issue in a timely manner may result in permit action.
Send correspondence to pdsc@mcecknc.gov and Marie.daley@mecknc.gov
Updated CPO to Paul Rill
30 Day Intent to Suspend (ITS) for doors onto pool deck and deck clearance. Contact Marie Daley at 704-507-6806 when in compliance to lift ITS
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Records missing weekly alkalinity check.
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Operator checked and corrected.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
All ladders removed from pool.
.2521(a) Steps or ladders shall be provided every 75 ft along the shallow area perimeter.
.2521(a) Pools greater than 30 ft wide, shall have a ladder on each side of the deep end.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed multiple doors not latching or alarmed at time of inspection.
.2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm.
*Permit item
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Bleachers within 8’ of pool.
.2522(a) Provide 8 ft of clear walking space around the pool at all times (>1600 sq. ft). This is indoor pool. Will have discussion regarding indoor pool clearance at pool greater than 1600 sq ft and follow up with operator, then document decision.
*Permit item
#22 · Premises: emergency telephone provided −6
Signage missing by emergency phone.
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Operator relocated signage by phone and corrected.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
No spare pump basket available for pump.
.2518(e) Provide a spare basket for pump. Note, pump is special order and older, no replacement basket available. Lack of severity does not warrant permit action.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Pump room floor observed with water. .2533(d) Pump room floor shall be kept dry and free of standing water.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Showers in restroom observed soiled and with mold. Restrooms in need of cleaning.
.2526(m) Keep restrooms and fixtures clean and in good repair.
Advised cleaning schedule to mitigate mold issue.
Jan 9, 2023 26 demerits · 7 violations
Inspector comments: Intent to Suspend (ITS) items include: records, offsets in deck/ladders and doors self-closing, self-latching or audible alarm. Contact Marie Daley at 704-507-6806 when corrected to lift ITS.
**Main drains expire November 2023. Replace and submit updated PDSC form PRIOR to expiration to avoid permit action.
Advised showering of patrons before entering pool
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Observed daily main drain checks and temperature not recorded for this week.
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
*Permit items
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Some debris on main drains. Keep drains free of debris.
.2537(14) Keep pool surface and pool floor free of debris. Operator cleaned and corrected.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed loose ladders on ends of pool closest to main entrance. Tighten loose ladders.
.2521 Install ladders per manufacturer instructions.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed multiple doors with chimes turned off. No alarm at back door to equipment. Closer broken on door by front exit.
.2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm.
*Permit item
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Multiple holes in deck from ladders removed and missing plugs with gaps greater than 1/2" on deck around pool. Some items within clearance of pool. Operator removed items for clearance. Corrected.
.2522(a) Provide 8 ft of clear walking space around the pool at all times (>1600 sq. ft).
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile.
*Permit item
#22 · Premises: emergency telephone provided −6
Emergency telephone inoperable at time of inspection.
.2530(f) Emergency phone shall remain operable. Operator repaired and corrected.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Soap out in men’s restroom in back of establishment. .2526(j) Provide soap and soap dispenser, no glass, at each sink.
Oct 19, 2022 12 demerits · 3 violations
Inspector comments: Repair emergency phone. Return visit to take place next week.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Observed daily maindrain checks not recorded for this week. Record daily main drains checks in log book everyday that the pool is open.
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed loose ladders on ends of pool closest to main entrance. Tighten loose ladders.
#22 · Premises: emergency telephone provided −6
Emergency telephone inoperable. Utilized phone in staff office which is less than 75 from pools edge. New signage and phone number was placed visibly in main pool area. Advised to have emergency phone repaired. Return visit to take place next week.
Feb 9, 2022 6 demerits · 2 violations
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed loose ladder at end of pool near locker rooms. Tighten Ladder.
.2521 Install ladders per manufacturer instructions.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed multiple doors with chimes turned off. Chimes must be turned on if doors are not self-closing/ self- latching. Corrected onsite.
Dec 2, 2021 8 demerits · 2 violations
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed loose ladder at corner of pool closest to locker rooms. Tighten ladder.
.2521 Install ladders per manufacturer instructions.
#22 · Premises: emergency telephone provided −6
Emergency phone inoperable at time of inspection. Temporary emergency phone in office next to pool deck is approved until actual emergency phone is repaired. Signs posted and 911 operator had correct information. Once repaired, ensure emergency phone rings back when called.
Mar 16, 2021 28 demerits · 7 violations
Inspector comments: 5 - Some reagents expired. Replace reagents in test kit.
15 - One grab rope on ring buoy starting to degrade and flaking off when picked up. Replace ring buoy within 30 days.
Colleen Dougher present during the inspection. No signature due to covid restrictions. Reports emailed to operator.
Intent to Suspend issued for depth markers on pool wall and deck, doors self-closing, self-latching or with audible alarm, deck damage, and chlorinator verification.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Some debris on main drain closest to pump room. Keep drains free of debris.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
Multiple depth markers on pool walls either peeling off or missing parts of ft/lettering. Provide wall depth markers at 25 ft. apart or less in 4" in lettering. Intent to Suspend issued.
>25 ft. between wall/deck depth marker at 11 ft. 6 in. Right side of pool. >25 ft. between wall depth markers (left side of pool closest to pump room). Maintain 25 ft. or less measured around the pool perimeter on wall depth marker. Intent to Suspend issued.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Ladder handrails not secured at shallow end of pool. Ensure, when in place, they are secure.
Paddock starting platforms measuring at 31" from water level. Platforms shall measure no greater than 30" from water level.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Multiple doors on to pool deck with bell chime as audible alarm. Bells are rusted and are no longer audible. Hard rain occurred during the inspection and bells could not be heard. All doors on to pool deck shall self-close, self-latch or self-close with audible alarm. Intent to Suspend issued.
Door near back restrooms not latching. Repair to self-close, self-latch. Intent to Suspend issued.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Damage to pool deck near back restrooms with offsets >1/2". Repair decking. Intent to Suspend issued.
Some standing water on pool deck where deck is not sloped to drain. Continue to monitor to ensure that it does not present a slip hazard. Some deck drains with debris. Keep clean.
#22 · Premises: emergency telephone provided −6
Emergency phone number faded off of signage. Corrected during the inspection. Phone verified with callback.
#23 · Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 −4
Could not verify chlorinator at time of inspection. Automated chlorinators/acid feeders shall detect flow from the pump and turn off or alarm when no flow. Intent to Suspend issued. Operator must demonstrate flow detection on system.
Dec 8, 2020 32 demerits · 7 violations
Inspector comments: ITS for records, offsets greater than 1/2" on deck, doors self-closing, self-latching or audible alarm and signage (1" exact wording).
Changed to "W" status
No signature due to COVID-19.
Inspection with Colleen Dougher and Rachel Santimaw
Report to dougherco@swimmaccarolina.org
#1 · Water quality: water clear enough to clearly see bottom of pool and pool drain −6
Main drain covers hard to see clearly from deck due to hair, band aids and debris covering parts of cover.
.2535(2) Main drains must be clearly visible from the pool deck. Operator brushed and lifeguard removed debris coving drains to be clearly visible. Corrected.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Main drain checks not logged daily on lifeguard record sheet or in log book.
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
*30 Day Intent to Suspend (ITS) item
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Multiple body hooks on pool deck. One body hook pole measured 10'. .2530(a) Provide at least 12 ft. long pole with body hook securely attached. If emergency equipment is on pool deck, must meet compliance. Operator removed this hook and left correct 12" pole with body hook on deck. Corrected.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Multiple doors onto pool deck not self-closing, self-latching or audible alarm.
.2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm.
*30 Day Intent to Suspend (ITS) item. Contact Marie Daley at 704-507-6806 when in compliance to lift ITS.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Multiple holes from ladders removed and cracked plugs, with gaps greater than 1/2" on deck around pool. Chairs for social distancing (COVID) within deck clearance at back of pool.
.2522(a) Provide 8 ft of clear walking space around the pool at all times (>1600 sq. ft).
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile.
*30 Day Intent to Suspend (ITS) item. Contact Marie Daley at 704-507-6806 when in compliance to lift ITS.
#18 · Premises: lifeguards present or warning signs posted −4
Observed pool signage measuring less than 1" in height for lettering. At times there is not a lifeguard, signage must meet regulations.
.2530(c) Provide "Adults should not swim alone." in 1" lettering.
.2530(c) Provide "Children should not use the swimming pool without adult supervision." in 1" lettering.
*30 Day Intent to Suspend (ITS) item. Contact Marie Daley at 704-507-6806 when in compliance to lift ITS.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
No spare pump basket available for pump.
.2518(e) Provide a spare basket for pump. Note, pump is special order and older, no replacement basket available. Lack of severity does not warrant permit action.
Jan 31, 2020 2 demerits · 1 violation
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed loose ladders. Tighten when in place.
.2521 Install ladders per manufacturer instructions.
Nov 14, 2019 6 demerits · 2 violations
Inspector comments: Observed a secondary motor that appears to be used for the injection of an additive for the pool. (Hayward Superpump 3/4HP) This motor is not used to contribute to flow, but it was observed not to have an electrical bonding wire visable. The motor was unplugged and C. Elmore advised that this condition could be a hazard. C. Elmore advised that an electrician should been consulted and an electrical permit/inspection should be obtained for this motor before it can be put back into service. Contact C. Elmore at 704-507-6814 when this is resolved.
Observed some of the records not to be clear on what is being checked on a daily and weekly basis. Disinfectant, pH, water temperature and main drains must be checked on a daily basis. Total Alkilinity and Cyanuric Acid (if in use) must be checked once a week. If water chemistry is corrected, it is valuable to note the correction and outcome. Disinfectant cannot be hand-fed as a means of normal operation when the pool is open to swimming.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed some chips in diving platform surfaces. Maintain the platforms so they remain in good repair.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed rear exit door to self-latch, but not self-close. The door must self-close and self-latch or self-close and be audibly alarmed.
I.T.S. issued. Expires 12/14/19.
Feb 28, 2019 12 demerits · 3 violations
Inspector comments: G.C. OBSERVED NO LIFEGUARDS ON-DUTY DURING SWIMMING. SIGNS AND SAFETY EQUIPMENT WERE PRESENT. LIFEGUARDS ARE REQUIRED DURING SWIMMING.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
OBSERVED DEPTH MARKERS TO HAVE PORTIONS PEELED OFF AND/OR MISSING, SUCH AS THE "FT" MARKINGS. CHECK AND CORRECT ALL DEPTH MARKERS.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
ALL DOORS THAT LEAD TO SPACES EXTERIOR TO THE POOL, SUCH AS LOCKER ROOMS, LOBBY, OR THE OUTSIDE, MUST BE SELF-CLOSING AND SELF-LATCHING OR AUDIBLY ALARMED. OBSERVED ALARMS NON-FUNCTIONAL OR TURNED OFF ON SOME DOORS. OBSERVED GLASS EXIT DOORS THAT WERE SUPPOSED TO REMAIN LOCKED AT ALL TIMES TO BE UNLOCKED AND STANDING OPEN. IT WAS LATER CLOSED, BUT REMAINS NOT SELF-CLOSING AND SELF-LATCHING. CORRECT ALL THE DOOR ON THE DECK, INCLUDING THE GLASS ONES. I.T.S. ISSUED EXPIRES 3/30/19.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
OBSERVED FLOW METER STUCK. REPAIR THE FLOW METER.
Nov 16, 2018 0 demerits · 0 violations
Inspector comments: No violations noted. Ensure that proper PDSC information is given to Katie Wilson so that PDSC information can be updated to the department.
No violations were recorded for this inspection.
Mar 22, 2018 8 demerits · 2 violations
Inspector comments: Observed doors not used for ingress/egress to be kept locked from the inside. Maintain these doors locked.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed some tile in disrepair. Repair tile damage and maintain pool interior in good repair.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed door alarms not functioning upon arrival. Alarms were corrected.
Nov 17, 2017 8 demerits · 2 violations
Inspector comments: Intent to Supsend issued for depth markers and doors not self-closing/self-latching. Expires on 12/17/17.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
Observed depth markers to have peeled off the inside of the pool wall. Replace damaged/missing depth markers. Numbers must be at least 4 inches high and depth must be designated in feet. I.T.S. Issued.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed ingress/egress doors leading onto the pool deck not to be self-closing/self-latching. Such doors must be either kept locked, be self-closing/self-latching, or be alarmed such that they issue an alert if the door is opened. I.T.S. Issued.
Feb 15, 2017 0 demerits · 0 violations
Inspector comments: No violations observed during inspection.
No violations were recorded for this inspection.
Nov 28, 2016 0 demerits · 0 violations
Inspector comments: No violations observed during inspection
No violations were recorded for this inspection.
Feb 4, 2016 4 demerits · 2 violations
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed loose ladders. Tighten loose ladders.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed water on pump room floor. Repair leak.
Oct 22, 2015 2 demerits · 1 violation
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed ladders loose and greater than 75 feet apart on the shallow end of pool.
Apr 7, 2015 2 demerits · 1 violation
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Observed hot water in bathroom to be at 120F. Hot water shall be no more than 110F.
Nov 20, 2014 8 demerits · 3 violations
Inspector comments: -GC- Staff member was asking about a "waiver" on the main drain regarding their lifespan. Contact Katie Wilson with MCHD regarding this as C. Elmore is not aware of such a document or process.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Observed no notation on some record sheets of main drain checks. Make a notation to note each such check. Do not leave it blank.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed ladders removed such that there is not one set at required intervals.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Observed hot water to be at 115F at least. Hot water in fixtures shall be no hotter than 110F. Observed hand-dryer broken. Ensure all fixtures are properly operational and in good repair.
Mar 10, 2014 18 demerits · 6 violations
Inspector comments: 15 - General Comment: Observed 2 buoys with loose beckets. Provide USCG approved ring buoys. Intent to Suspend issued for #11 and #19. Note: Electrical cord plugged in on deck upon arrival. Removed during inspection. Do not use electrical equipment on deck.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Observed main drain checks not recorded daily; alkalinity not recorded weekly. Record as required.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed only one ladder in pool. Install ladders every 75 ft or less. Intent to Suspend issued. Observed diving platforms not in use and not secured. Provide active supervision and removal, covering, or signage when not in use. Observed some diving platforms >30" above surface water in some areas with water >4 ft. Maintain no greater than 30".
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed some algae on pool deck and stools next to pool. Keep deck clean and maintain 5 ft clearance.
#19 · Premises: signs prohibit glass containers or pets in pool area −4
Observed no signage for pets. Provide sign prohibiting pets. Intent to Suspend issued.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed pump room unlocked. Keep locked.
#27 · Equipment room: filter backwash discharged through an air gap −2
Observed no air gap at backwash line to pit. Keep air gap.
Dec 4, 2013 4 demerits · 1 violation
#5 · Water quality: daily written records of water quality and test kit kept on site −4
KEEP WEEKLY RECORDS FOR ALKALINITY
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “SWIMMAC CAROLINA - LAP” or State ID 2060530054). Inspection type (routine vs. follow-up) is not published in the county's data.