10demerits
DRURY INN & SUITES POOL
415 W W T HARRIS BLVD, Charlotte, NC 28262
Year-Round Swimming Pool · NC permit/State ID 2060530071
Latest result10 demerits
Last inspectedJan 6, 2026
Inspections on record26
On record sinceSep 11, 2013
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Sep 11, 2013Lower is betterJan 6, 2026
Inspections & violations
Jan 6, 2026 10 demerits · 2 violations
Inspector comments: Replace ring buoy in inside section of pool or remove.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed 2 of 4 weirs missing. Replace missing weirs.
.2518(k) Replace missing weirs.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Indoor ring bouy in poor condition. Replace. Throw rope in excess of 33 feet. Corrected throw rope onsite. Outside ring bouy and throw rope are in compliance.
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less.
.2530(a) Provide USCG approved ring buoy. A rescue tube with lifeguard may be substituted for ring buoy.
Aug 5, 2025 10 demerits · 3 violations
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed 1 ladder missing rung. replace.
.2521 Install ladders per manufacturer instructions.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed deck chairs within 5 feet of pools edge. Maintain five feet of clearance at all points.
.2522(b) Provide at least 5 ft of clear walking space around the pool at all times.
#18 · Premises: lifeguards present or warning signs posted −4
All warning signs missing. Replaced onsite during inspection with new signage.
Jan 6, 2025 6 demerits · 2 violations
Inspector comments: All items from intent to suspend have been corrected. Permit re instated.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed debris in outside skimmers. Keep skimmers free of debris.
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed 1 ladder missing endcap. Replace.
.2521 Install ladders per manufacturer instructions.
Dec 3, 2024 20 demerits · 4 violations
Inspector comments: Issued intent to suspend for missing weirs and incorrect lifeguard and warning signs. Please correct items with in 30 days and call James Bjorneboe @ 704-507-6820 to schedule re-visit once items are corrected.
Inspection led by Maddie Denoncour.
#3 · Water quality: pool water pH −6
Observed pH at 6.9. Adjusted to 7.2 onsite.
.2535(1) Maintain pH at 7.2 to 7.8.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed all three weirs missing in pool. Replace missing weirs.
.2518(k) Replace missing weirs.
#18 · Premises: lifeguards present or warning signs posted −4
Observed “WARNING NO LIFEGUARD ON DUTY” sign missing. Provided sign in 4 inch letters. Also observed “Children should not use the swimming pool without adult supervision” sign missing. Provide signage in 1 inch letters. Intent to suspend item.
#22 · Premises: emergency telephone provided −6
Observed no phone number posted at emergency phone. Corrected on site.
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone.
Feb 1, 2024 24 demerits · 5 violations
Inspector comments: Issued intent to suspend for missing water quality records (.2535).
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Observed no daily written records. Keep daily written records as required.
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed excessive debris in outside skimmer. Keep skimmers free of debris.
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed throw rope tangled. Corrected on site.
.2530(a) Lifesaving equipment includes body hook and pole and USCG approved ring buoy with required rope length.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed deck chair with in 6 feet of pools edge at outside section of pool. Maintain 6ft of clearance at outside section of pool.
.2522(a) Provide 6 ft of clear walking space around the pool at all times.
#22 · Premises: emergency telephone provided −6
Emergency phone inoperable. Corrected onsite.
.2530(f) Emergency notification systems must provide 24 hr. monitoring, be capable of routing calls to 911, and be able to electronically transfer Automatic Number and Locator Identification for the phone.
Nov 15, 2023 10 demerits · 3 violations
Inspector comments: Maintenance supervisor was advised to add required pool rules on the indoor enclosure section of the pool to be more readily visible to swimmers.
Drain covers replaced and PDSC form items have been verified (10/27/23).
Pool inspection completed by Jordan Johnson accompanied by the Stacie Rhea and Catie Johnson.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs.
Pool missing 3 weirs. Replace weirs.
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.
All skimmers in need of cleaning, debris observed in all 3 pool skimmers.
-Corrected.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions.
Ladder loose in outdoor area of the pool enclosure.
Ladder in need of repair.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times for outdoor portion of pool. Some chairs and tables were too close to the pool in the outdoor portion of pool enclosure.
Corrected.
Permanent glass fixture around the door obstructs required 5ft of clearance on the indoor portion of the pool.
Jan 5, 2023 4 demerits · 2 violations
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Some ladders loose. .2521 Install ladders per manufacturer instructions.
Some ladders extend > 6” into the pool. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall.
Handrail missing escutcheon plate. .2521 Install handrail per manufacturer instructions.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Leaky valve near spa heat exchanger. .2533(d) Pump room floor shall be kept dry and free of standing water.
Nov 3, 2022 20 demerits · 5 violations
Inspector comments: Inspection conducted with inspector Hannah Howard and CPO Steve Hoyt.
Labels not observed on spa pumps. Verified that pump is a Sta-Rite pump with 2 HP motor.
Pool safety signage is only posted in the outdoor pool area. Recommend providing safety signage in the indoor pool area as well.
Emergency phone number calls back to front desk. Ensure that someone is at the front desk whenever the pool is open.
Outer rope on ring buoy starting to fray. Recommend replacing with US Coast Guard approved ring buoy and 33 foot throw rope.
#3 · Water quality: pool water pH −6
pH 7.0. .2535(1) Maintain pH at 7.2 to 7.8. - Corrected to 7.2.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Missing 1 of 3 weirs. .2518(k) Replace missing weirs.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Some ladders loose. .2521 Install ladders per manufacturer instructions.
Some ladders extend > 6” into the pool. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall.
Handrail missing escutcheon plate. .2521 Install handrail per manufacturer instructions.
#22 · Premises: emergency telephone provided −6
Phone number posted does not match what 911 has. .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. - Corrected.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Leaky valve near spa heat exchanger. .2533(d) Pump room floor shall be kept dry and free of standing water.
Jan 11, 2022 18 demerits · 5 violations
Inspector comments: Facility has a CPO, but he was not present today.
Immediate suspension issued due to cloudy water.
#1 · Water quality: water clear enough to clearly see bottom of pool and pool drain −6
.2535(2) Main drains must be clearly visible from the pool deck. Pool is cloudy and drains are difficult to see from certain areas of pool deck. *Immediate suspension item
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Entries for cyanuric acid and total alkalinity are missing for the past month.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Surface skimmers shall be installed per manufacturer's instructions. Skimmer baskets are incorrect size and have rocks in them. Skimmers shall be designed and constructed in accordance with section 8 of NSF Standard #50. // .2518(k) Replace missing weirs. Weir missing in 1 skimmer basket.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions. 1 ladder missing end cap and another missing tread.
#27 · Equipment room: filter backwash discharged through an air gap −2
.2513(b) Filter backwash shall be discharged through an air gap. Air gap missing on back wash.
Nov 17, 2021 28 demerits · 7 violations
Inspector comments: Inspection conducted with inspector Sam Cary and maintenance staff Steve Hoyt. Due to COVID-19 precautions, inspection not signed by maintenance.
Verified that outdoor lighting works.
Label missing on pump. Verified Sta-Rite pump with 2 HP motor.
Liquid acid stored in buckets labeled as containing bromine. Ensure chemicals are properly stored in properly labeled containers.
Skimmer baskets with rocks. Use only properly sized NSF approved skimmer baskets. Can use NSF approved weighted baskets.
Intent to suspend issued
5)
#3 · Water quality: pool water pH −6
pH 7.1. .2535(1) Maintain pH at 7.2 to 7.8. - Corrected to 7.2.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Facility does not have a CPO on staff to check the pool every day. .2537(c) Pool owner shall provide for the operation and maintenance of the pool by a trained pool operator. - Intent to suspend item.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Some skimmer baskets are the wrong size. .2518(k) Skimmers shall be designed and constructed in accordance with section 8 of NSF Standard #50.
Maintenance vacuuming through the skimmer. Pool built with Integral vacuum system. .2518 (f) Vacuum the pool through the integral vacuum system.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Some ladders loose. One missing an endcap. .2521 Install ladders per manufacturer instructions.
Ladder missing non-slip tread. .2521(b) Ladders shall have slip-resistant tread.
Escutcheon plate missing on handrail. .2521 Install handrail per manufacturer instructions.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Some chairs too close to pool edge. .2522(a) Provide 6 ft of clear walking space around the pool at all times for outdoor portion of pool. - Corrected
Some chairs too close to pool edge. .2522(b) Provide at least 5 ft of clear walking space around the pool at all times for indoor portion of pool. - Corrected.
#22 · Premises: emergency telephone provided −6
Emergency phone not functioning. .2530(f) Emergency phone shall remain operable. - Corrected.
Incorrect dialing instructions posted, phone number not posted. .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. - Corrected.
#27 · Equipment room: filter backwash discharged through an air gap −2
No air gap for backwash. .2513(b) Filter backwash shall be discharged through an air gap.
Jan 20, 2021 16 demerits · 5 violations
Inspector comments: Inspection conducted with inspector Rachel Santimaw and pool operator Steve. Due to COVID-19 precautions, inspection was not signed by the operator.
Outside ring buoy damaged. Recommend replacing with US Coast Guard approved ring buoy with 33 foot throw rope.
Equalizer line covers expire February 1, 2021. Replace with APSP-16 2017 approved covers or abandon the equalizer lines per state guidelines.
Fill line manual fill through check valve. Does not meet ASSE rating of .2512 (listed as ASSE1015). If ever replaced, replace with approved check valve.
“Executive Order No. 141 or subsequent Orders are in effect unless such Orders are rescinded or superseded by another applicable Order.”
Intent to suspend issued.
21
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Missing two weirs. .2518(k) Replace missing weirs.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Some ladders loose. One missing an endcap. .2521 Install ladders per manufacturer instructions.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
One eyeball fitting missing. .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair.
#21 · Premises: pool and deck lighting provided at pools that operate at night −4
Underwater light partially popped out of the niche. .2537(9) Underwater light niches shall be maintained or covered so not to present a hazard. - Intent to suspend item.
#27 · Equipment room: filter backwash discharged through an air gap −2
No air gap for backwash. .2513(b) Filter backwash shall be discharged through an air gap.
Nov 17, 2020 34 demerits · 9 violations
Inspector comments: Inspection conducted with maintenance regional Matt Steller. Due to COVID-19 precautions, inspection was not signed by the operator.
Pool has automatic acid feeder. pH was low on the last inspection as well. Ensure that controller is properly calibrated.
Verified that outside lights still work. Pool still approved for night swimming.
Emergency call back goes to the front desk. Ensure that front desk is always attended or reroute emergency phone call backs to the emergency phone.
Permits posted are expired. Go to Meckpools.Charmeck.org to print current permits and post in the pool area.
Equalizer line covers expire February 1, 2021. Replace with APSP-16 2017 approved covers or abandon the equalizer lines per state guidelines.
Fill line manual fill through check valve. Does not meet ASSE rating of .2512 (listed as ASSE1015). If ever replaced, replace with approved check valve.
“Executive Order No. 141 or subsequent Orders are in effect unless such Orders are rescinded or superseded by another applicable Order.”
Intent to suspend issued
5)
8)
24)
#3 · Water quality: pool water pH −6
pH 7.1. .2535(1) Maintain pH at 7.2 to 7.8. Corrected to 7.2.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
No main drain checks. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for total alkalinity. - Intent to suspend item.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Missing 2 of 3 weirs. .2518(k) Replace missing weirs. - Intent to suspend item.
Some skimmers with debris. Ensure that skimmer baskets are emptied regularly.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Ladders loose, missing endcaps, or steps loose. .2521 Install ladders per manufacturer instructions.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
Eyeball fitting missing from one of the returns. .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
One of two ring buoys damaged. .2530(a) Provide USCG approved ring buoy with attached 33 foot throw rope. Damaged ring buoy removed, other ring buoy and throw rope meets requirements.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter stuck. .2518(g) Keep flow meter operational. - Intent to suspend item.
Spare pump basket not observed. .2518(e) Provide a spare basket for pump.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Chemicals stored in the pump room..2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
Liquid acid for automatic feeder stored in a bucket labeled as containing bromine. .2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Hot water in restrooms 120F. .2526(i) Water in restrooms shall not exceed 110 F.
Feb 25, 2020 8 demerits · 2 violations
Inspector comments: Verified PDSC information.
#3 · Water quality: pool water pH −6
Observed pH below 7.0 corrected to 7.2 during inspection.
.2535(1) Maintain pH at 7.2 to 7.8.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed ladder greater than 6 inches from wall.
.2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall.
Nov 5, 2019 40 demerits · 12 violations
Inspector comments: 6 - THP for pump at 2.6 hp. Pump listed as 2 hp pump on PDSC form. Max-e-glass II pump does not have 2.5 hp pump.
Intent to Suspend issued for light flush to wall and gate at outside barrier.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Log book without weekly alkalinity records. Missing some weeks. Record total alkalinity weekly.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Light protruding from pool wall in outside pool area. Repair light to wall. Intent to Suspend issued.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
One weir missing in outdoor skimmer and one skimmer with debris in basket. Replace skimmer weir and keep skimmer baskets clean of debris to allow for proper circulation.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Multiple ladders with >6" from pool wall to ladder rung. Maintain 3" to 6" between pool wall and ladder rung. One ladder missing end cap. Provide end cap to prevent damage to the pool wall.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
One return fitting missing eyeball. Replace eyeball fitting.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
One ring buoy rope at 31 ft. and other ring buoy rope to short due to tied off rope. Replaced with 33 ft. rope during inspection.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Outside gate locked. No key available. Gate shall self-close, self-latch. Latching mechanism less than 54". Provide no opening greater than 1/2" within 18" of latch mechanism. Repair gate to self-close, self-latch with no opening greater than 1/2" wihtin 18" of latch mechanism. If approved by Code Enforcement, gate can be made not a gate and part of the pool barrier by removing latching mechanism and securing permanently. Intent to Suspend issued.
Fence at <48" around outside pool. Maintain 48" or greater for fencing.
Trash can located outside of pool barrier outside provides foothold. Eliminate foothold.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter stuck. Maintain a functional flow meter.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Plastic container in pump room with no label.
.2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up.
#27 · Equipment room: filter backwash discharged through an air gap −2
No air gap at backwash line to pit. Provide air gap.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
No shower sign posted. Post visible upon entry to swimming pool on inside and outdoor pool areas.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
Fill line manual fill through check valve. Does not meet ASSE rating of .2512 (listed as ASSE1015). If ever replaced, replace with approved check valve.
Jan 14, 2019 12 demerits · 3 violations
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed ladder missing end cap. Replace missing end cap.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed throw rope at 31 feet. Throw rope must remain at 33 feet. Corrected to 33 feet on site.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed deck chairs within 6 feet of pools edge on outside section of pool. Maintain 6 feet of deck clearance at all points. Corrected onsite.
Nov 19, 2018 8 demerits · 2 violations
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed missing endcap on one ladder. Replace.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed ring bouy in outdoor section of pool with rope 20' in length. Corrected to 33' onsite.
Feb 5, 2018 26 demerits · 7 violations
Inspector comments: Intent to suspend issued.
24)
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Some skimmer baskets full. Clean skimmer baskets regularly.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Some ladders loose or missing endcaps. Maintain secure and in good condition with endcaps.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
One inlet fitting missing. Provide functional inlet fittings.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Pool with two ring buoys. One with throw rope that was too short. Provide US Coast Guard approved ring buoy with 33 foot throw rope. Non-complaint ring buoy removed by operator.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Some outside deck chairs too close to pool edge. Maintain at least 6 feet clear walkway around the pool. Corrected.
Caulking peeling by one of the skimmers. Maintain deck free of trip hazards.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter installed between the pump and the filter. Install flow meter on the filtered water light per manufacturer's instructions. Recommend installing after the heater. - Intent to suspend item.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Some chemicals stored in pump room.
Provide either forced air or cross ventilation in chemical storage room.
Recommend adding lighting to chemical storage room.
Dry chemicals stored on the ground. Corrected by operator.
Oct 23, 2017 22 demerits · 6 violations
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Some ladders loose. One ladder missing an endcap. Maintain secure and in good condition.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
One inlet fitting broken. Replace.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Throw ropes 29 feet. Provide 33 foot throw rope. Corrected by operator.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Some deck chairs too close to the pool. Maintain at least 5 feet deck clearance on inside pool area and at least 6 feet deck clearance on outside pool area. Corrected by operator.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter stuck. Repair or replace.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
No ventilation in chemical storage room. Provide either continuous forced air or cross ventilation.
Mar 21, 2017 4 demerits · 1 violation
Inspector comments: OBSERVED DAILY AND WEEKLY RECORDS BEING KEPT, BUT WITHOUT A SPECIFIC ENTRY FOR DAILY MAIN DRAIN CHECKS. THIS MUST BE DONE EVERY DAY THE POOL IS OPEN.
OBSERVED SOME PATCHING TO THE DECK, CONTINUE TO MAKE REPAIRS TO THE DAMAGED DECK AREAS, SPECIFICALY AROUND THE LADDERS.
CPO: ALLEN EBY
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
OBSERVED FLOW METER TO BE NON-FUNCTIONAL. REPAIR THE FLOW METER.
Nov 29, 2016 22 demerits · 5 violations
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
Observed ladder missing rubber foot. Replace rubber foot.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed 21ft. throw ropes on ring buoys. Pool width is 21ft. Rope was corrected to 32ft. -CDI
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed damage and wear to decking, mastic, and ladder anchor points. Repair such damage and wear.
#22 · Premises: emergency telephone provided −6
Observed 911 phone non-functional. Phone was replaced. -CDI
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed flow meter stuck. Repair it.
Jan 20, 2016 14 demerits · 3 violations
Inspector comments: G.C. Observed pump doesn't match submitted PDSC sheet. Submit new correct PDSC sheet to Katie Wilson at MCHD.
#3 · Water quality: pool water pH −6
Observed pool pH to be 6.9. pH 7.2-7.8 is required. Pool closed by manager instruction.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Observed all records properly kept except alkalinity not kept weekly. Alkalinity must be kept 1 time a week at least.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed flow meter stuck. Repair it.
Sep 24, 2015 10 demerits · 2 violations
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed throw rope to be 35ft. long. Throw rope was shortened to 33ft. -CDI
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed minor deck damage at the outside pool ladder. Repair any such damage.
Feb 11, 2015 12 demerits · 4 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed minor debris in skimmers. Keep skimmers free of debris.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed loose ladder. Tighten loose ladder.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed minor deck chipping at outside ladder. Repair.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Observed hot water in restrooms at 117 degrees. Hot water in restrooms should not exceed 110 degrees.
Oct 15, 2014 24 demerits · 7 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Some algea on pool walls and in skimmers. Keep clean and in good repair.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
One skimmer without weir and one damaged skimmer basket. Keep in good repair and replace weirs where needed.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
One ladder missing slip resistant tread. Replace tread on ladder rung.
#22 · Premises: emergency telephone provided −6
Emergency phone not visible from outdoor deck. Wording on sign had fade from sun. Corrected during inspection.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter stuck. Keep operational.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
No lighting or cross/forced ventilation in the chemical storage room. Provide adequate lighting and continuous forced ventilation or cross ventilation. Pump room floor wet. Keep dry.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Water in restrooms >113 F. Maintain at 110 F or below.
Mar 12, 2014 2 demerits · 1 violation
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
WATER ON PUMP ROOM FLOOR
Sep 11, 2013 16 demerits · 5 violations
Inspector comments: Permit not posted. Post visible on deck. Found at meckpools.charmeck.orgIntent to Suspend issued for #9
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed algae on pool walls. Keep clean.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed algae in skimmers and on baskets. Keep clean.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
Observed 3 wall depth markers without ft. Provide ft for 3 1/2 ft. Intent to Suspend issued.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed one end cap missing on ladder. Replace.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed no cross/forced ventilation in chem storage room. Provide adequate ventilation.
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “DRURY INN & SUITES POOL” or State ID 2060530071). Inspection type (routine vs. follow-up) is not published in the county's data.