PRESERVE AT BALLANTYNE, THE

11280 FOXHAVEN DRIVE, Charlotte, NC 28277
Year-Round Swimming Pool · NC permit/State ID 2060530091
Latest result34 demerits
Last inspectedOct 12, 2026
Inspections on record25
On record sinceJun 26, 2013

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

01734 Jun 26, 2013: 4Oct 16, 2013: 14May 29, 2014: 10Nov 3, 2014: 4May 20, 2015: 14Jun 21, 2016: 4Nov 22, 2016: 10Feb 21, 2017: 10Nov 6, 2017: 22Apr 4, 2018: 16Dec 6, 2018: 12Apr 16, 2019: 4Sep 9, 2019: 12Mar 9, 2020: 12Aug 12, 2020: 6Apr 29, 2021: 14Oct 19, 2021: 30Apr 5, 2022: 4Oct 11, 2022: 10Mar 7, 2023: 12Sep 6, 2023: 14Apr 29, 2024: 8Jul 1, 2025: 30May 12, 2026: 4Oct 12, 2026: 34
Jun 26, 2013Lower is betterOct 12, 2026

Inspections & violations

Oct 12, 2026 34 demerits · 8 violations
Inspector comments: Conducted inspection with CPO and EHS Alex D. Pool remains in good standing and on A status. Night swimming must be re verified for 2026. Const. Date: 4/27/1998 Rope Length: 41' Night Swim?: Yes Pool not heated.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. PH observed at 8.2. Operator corrected to 7.7. No permit action.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide weekly recordings for cyanuric acid and total alkalinity. Two recent CYA/TA readings missing. All other records complete and accurate. Ensure consistent weekly recordings of CYA and TA. No permit action.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Skimmers full of leaves. Operator emptied. No permit action. .2518(k) Replace missing weirs. Two out of six weirs missing. Replace. No permit action.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
.2523(b) Provide depth markers spaced not to exceed 25 feet when measured along the perimeter of the pool. 3 1/2 ft depth marker missing near clubhouse pool entry on decking. Operator replaced and re caulked tile down. No permit action.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Ground level windows shall not open greater than 4" on to pool deck or child protected by audible alarm. Three windows not fitted with limiters. Operator added limiters and corrected. Basketball court windows have plexiglass covering windows from the inside and windows are not accessible by inside patrons. Windows leading to pool deck from maintenance room do not have limiters. Maintenance room locked and only accessible by maintenance. No permit action. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. Brick part of fence by left side of clubhouse too short due to landscaping. Operator cleared out landscaping. Other parts of the fence (especially the left side) also has excess landscaping at bottom of fence. Pool built in 1998. Clear out excess landscaping prior to 2027 permitting season. No permit action.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Furniture within 6’ of pool. Moved and corrected. No permit action.
#18 · Premises: lifeguards present or warning signs posted −4
.2530(c) Provide "Children should not use the swimming pool without adult supervision." in 1" lettering. Signage missing word “THE”. Operator printed new temporary compliant sign. No permit action.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep the flow meter operational. Flow meter not operational. Operator corrected. Flow meter reads 160gpm. No permit action.

View this inspection on the county portal ›

May 12, 2026 4 demerits · 1 violation
Inspector comments: Inspection conducted with Robert Medlin. All out of compliance items were corrected during the inspection by operator.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Gate next to clubhouse was not self closing at time of inspection. .2537(b)All gates and doors shall be self-closing, self-latching. Operator adjusted and corrected during inspection. CDI

View this inspection on the county portal ›

Jul 1, 2025 30 demerits · 8 violations
Inspector comments: Visit to pool to lift suspension and Permit pool. Pool permitted, no night swimming until lighting verified from CPO Onsite visit due for night swimming 2026 Pool not heated Verified PDSC information is corrected. 2 SDX Retro VGBA 2008, 6 Aquastar 6HPHA “A” Open for Business Inspection with Michael Dennis and Kiana Hurley
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Records missing weekly readings. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Manager checked and recorded. Corrected.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Back gates and front door not latching at time of inspection. .2537(b)All gates and doors shall be self-closing, self-latching. Operator adjusted and corrected.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Furniture within 6’ of pool. .2522(a) Provide 6 ft of clear walking space around the pool at all times. Moved and corrected.
#18 · Premises: lifeguards present or warning signs posted −4
Signage missing word “THE”. .2530(c) Provide "Children should not use the swimming pool without adult supervision." in 1" lettering. Manager replaced sign and corrected.
#21 · Premises: pool and deck lighting provided at pools that operate at night −4
POOL LIGHTS (EXTERIOR)NOT TESTABLE -- NO NIGHT SWIMMING UNTIL REPAIRED OR SHOW VIA PICTURE
#22 · Premises: emergency telephone provided −6
Kings 3 not transferring, correct address to local 911. .2530(f) Emergency notification systems must provide 24 hr. monitoring, be capable of routing calls to 911, and be able to electronically transfer Automatic Number and Locator Identification for the phone. Manager contacted Kings three and had address location transfer corrected.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Some chemicals in pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. Pool built 1998.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Hot water over 110 F in men’s restroom. .2526(i) Water in restrooms shall not exceed 110 F. Glass soap dispensers and possible glass mirrors. .2526(j) Provide soap and soap dispenser, no glass, at each sink. . .2526(k) Provide shatterproof mirrors.

View this inspection on the county portal ›

Apr 29, 2024 8 demerits · 2 violations
Inspector comments: #22 -- EMERGENCY 911 NUMBER DIALS BACK TO MAINTENANCE SUPERVISOR -- 30 DAY INTENT TO SUSPEND Intent to suspend issued for daily records and emergency phone number
#5 · Water quality: daily written records of water quality and test kit kept on site −4
DAILY RECORDS NOT BEING MAINTAINED -- INTENT TO SUSPEND ISSUED -- 30 DAYS TO MAINTAIN
#21 · Premises: pool and deck lighting provided at pools that operate at night −4
POOL LIGHTS (EXTERIOR)NOT TESTABLE -- NO NIGHT SWIMMING UNTIL REPAIRED OR SHOW VIA PICTURE

View this inspection on the county portal ›

Sep 6, 2023 14 demerits · 4 violations
Inspector comments: 30 Day Intent to Suspend (ITS) issued for gates, CPO. Contact Marie Daley at 704-507-6806 when in compliance to lift ITS. Send verification of lighting at night for Night Swimming. Main drains expire December 2024. “W” ITS status
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Staff has changed, CPO no longer on property. Provide documentation of CPO. .2537(c) Pool owner shall provide for the operation and maintenance of the pool by a trained pool operator. *Permit item
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed 1 weir missing out of 6 skimmers. Replace the weir. No Permit Action taken.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Back gate not latching at time of inspection. .2537(b)All gates and doors shall be self-closing, self-latching. *permit item
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Some items within 3’ of equipment in pump room. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.

View this inspection on the county portal ›

Mar 7, 2023 12 demerits · 4 violations
Inspector comments: 30 day Intent to Suspend (ITS) issued for pool wall, tiling/coping, windows onto pool deck and gate openings, greater than half inch around latching mechanism. Contact Marie Daley at 704-507-6806 when in compliance to lift ITS. Also, need to verify night swimming. Send verification to Marie Daley or schedule night swimming visit for renewal of night swimming permissions. Note: Main drains and skimmer equalizer line covers expire Dec 2024. Ensure updates are made and PDSC updated for approval, prior to expiration to avoid permit action.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Pool wall tiling chipped out under coping, very sharp at corner. .2537 No loose coping, keep in good repair *Permit item
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Windows onto pool deck open more than 4”. .2528(a) Ground level windows shall not open greater than 4" on to pool deck or child protected by audible alarm.**Permit item Magna latch below 54" in height. Gaps greater than 1/2" within 18" observed around latching mechanism. .2528(a) Gate latches located at less than 54" shall require the use of key, combination lock or card reader or be located on the inside of the gate at least three inches below the top of the gate with no greater than 1/2" within 18" of latch mechanism.**Permit item Fence less than 48" in height in some areas. Horizontals less than 45" in height on fence in some areas. Pool built 1998. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. .2528(a) Maintain 45" between bottom horizontal and next horizontal on fence and/or gate (post-May 2010).
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Some items within 3’ of equipment in pump room. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Hot water over 110 F in men’s restroom. .2526(i) Water in restrooms shall not exceed 110 F.

View this inspection on the county portal ›

Oct 11, 2022 10 demerits · 2 violations
Inspector comments: POOL HAS BEEN ISSUED AN IMMEDIATE SUSPENSION OF THE PERMIT. POOL IS CLOSED TO SWIMMING BY ORDER OF THE HEALTH DEPARTMENT. CONTACT C. ELMORE AT 704-507-6814 WHEN CLOSURE ITEMS ARE CORRECTED. POOL HAS A NIGHT SWIMMING APPROVAL. C. ELMORE WILL VERIFY NIGHT SWIMMING LIGHTING AFTER DUSK AT A LATER TIME.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed gate at the front of the pool to the left side of the club house to have a hinge that is less than 45 inches from the ground. The hinge provides a foothold. This must be corrected so that no footholds are left less than 45 inches from the ground. It is recommended that the hinge be raised to accomplish this. Observed fence not built to current spec. Less than 48 inches in some places. No Permit Action taken. Built prior to 2010.
#22 · Premises: emergency telephone provided −6
.2530(f) Emergency phone shall remain operable. Observed Kings III call box to be non-functional. Box must operate to call-in and call-out to reach local 911 service. Proper address and phone number for the call box must also be posted and verified with local 911 services.

View this inspection on the county portal ›

Apr 5, 2022 4 demerits · 1 violation
Inspector comments: CPO agreed to email of report. Observed flow meter to be at approximately 185GPM after backwash. Do not exceed 188GPM. Pool has passed inspection. New permit will be available for print on-line at the Health Department website. New permit sticker will be mailed
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed fence to be less than 48 inches in some places. 43 inches-47 inches depending on location. Fence was built prior to 2010. No permit action taken.

View this inspection on the county portal ›

Oct 19, 2021 30 demerits · 6 violations
Inspector comments: CPO AGREED TO EMAIL COPY OF REPORT NO SIGNATURE DUE TO COVID-19 PRECAUTIONS. CONTINUE TO FOLLOW ALL RELEVANT COVID RULES. POOL IS CLOSED TO SWIMMING BY ORDER OF THE HEALTH DEPARTMENT. WHEN CLOSURE ITEMS ARE CORRECTED, CONTACT C. ELMORE AT 704-507-6814 SO THAT CORRECTIONS CAN BE VERIFIED. POOL CANNOT REOPEN PRIOR TO HEALTH DEPARTMENT VERIFICATION OF CORRECTIONS. POOL HAS NIGHTSWIMMING EVALUATION. POOL LIGHTS WERE OBSERVED TO WORK, BUT DECK LIGHTS COULD NOT BE VERIFIED DURING THE DAY AS THEY ARE ON A PHOTO-CELL SWITCH. C. ELMORE WILL FOLLOW-UP TO EVALUATE THE DECK LIGHTS.
#2 · Water quality: disinfectant residual provided by −6
.2535(4) Maintain chlorine at least 1.0 ppm. Observed 0.2 ppm chlorine in the pool. I.S. Issued.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
pH, chlorine, and main drains must be checked once a day and recorded every day the pool is open. Total Alkalinity and Cyanuric Acid (if Cyanuric Acid is in use) must be checked once a week, 100ppm maximum for Cyanuric Acid. Keep proper records for all daily and weekly requirements. Observed gaps in the log book. No Permit Action taken, most of the records were complete.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. Observed 6 total skimmers with 2 missing the weirs. No Permit Action taken.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed ring buoy to be damaged due to weathering and sun. Observed rope to be frayed. Replace ring buoy and throw rope. Rope must be exactly 41 feet long from attachment point. Rope must be at least 1/4 inch thick. .2530(a) Lifesaving equipment includes body hook and pole and USCG approved ring buoy with required rope length. I.S. Issued.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed fence not to current spec. Shorter than 48 inches in some areas. Fence built prior to 2010.
#3 · Water quality: pool water pH −6
Observed pH to be 8.0. 7.2-7.8 Required for safety. I.S. Issued.

View this inspection on the county portal ›

Apr 29, 2021 14 demerits · 3 violations
Inspector comments: CONTINUE TO FOLLOW ALL RELEVANT COVID RULES POOL HAS PASSED INSPECTION AND BEEN ISSUED THEIR PERMIT STICKER. PAPER PERMIT WILL BE AVAILABLE ON-LINE FOR DOWNLOAD AND PRINTING AT OUR POOLS WEBSITE. POST PERMIT AND STICKER WERE VISIBLE AT POOL AREA. CPO AGREED TO EMAIL COPY OF REPORT NO SIGNATURE DUE TO COVID-19 PRECAUTIONS. DECK HAS BEEN RECOATED. VERIFIED SLIP RESISTANCE BY TESTING FRICTION AGAINST SKIN WHEN DECK WAS WET. OBSERVED POOL LIGHTS TO BE ON. DECK LIGHTS ARE ON AUTOMATIC PHOTO CELL. ENSURE THAT DECK LIGHTS OPERATE AS THEY DID WHEN NIGHT SWIMMING WAS VERIFIED. MAKE SURE ENOUGH LIGHT IS PRESENT FOR SAFETY IF NIGHT SWIMMING IS STILL ALLOWED.
#4 · Water quality: water temperature of heated pool −6
Observed pH to be 8.4 on arrival. pH was adjusted to proper range. -C.D.I.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed 1 weir missing out of 6 skimmers. Replace the weir. No Permit Action taken.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed fence not built to current spec. Less than 48 inches in some places. No Permit Action taken. Built prior to 2010.

View this inspection on the county portal ›

Aug 12, 2020 6 demerits · 1 violation
Inspector comments: “issuance of a permit by this department does not negate closure required by Executive Order No. 120, 138, 141, 147, or subsequent Orders in effect unless such Orders are rescinded or superseded by another applicable Order.” NO SIGNATURE WAS OBTAINED DUE TO COVID-19 SOCIAL DISTANCING
#22 · Premises: emergency telephone provided −6
Observed KINGS III call box non-functional upon arrival. Box was corrected during the inspection and was verified to have correct phone number and address. -CDI

View this inspection on the county portal ›

Mar 9, 2020 12 demerits · 3 violations
Inspector comments: Verified the following: Pump is IntellifloVS 011018 Main drains: (2) Paramount SDX2 Skimmer equalizer covers: (6) Aquastar 6HPHA Filters: (2) TR100 c Piping is 2.5" for skimmers and main drains, out of ground. Gates do not meet current code. Magna-latches are located less than 54" in height on inside of gate. There are gaps are greater than 1/2" within 18" of latching mechanism in some areas on some gates. This item may require correction to avoid permit action. Tim Dutcher and Chris Elmore will make return visit for this item, since pool was permitted in this condition for 2019 pool season. Operator requested a different inspector. Pool will NOT be permitted for Night Swimming without an additional visit made before dawn or after dusk for this permitting season.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Weirs missing at time of inspection. .2518(k) Replace missing weirs. Operator replaced and corrected. Leaves and debris in skimmers. Debris in skimmers. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Operator emptied and corrected.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Magna latch below 54" in height. Gaps greater than 1/2" within 18" observed around latching mechanism. .2528(a) Gate latches located at less than 54" shall require the use of key, combination lock or card reader or be located on the inside of the gate at least three inches below the top of the gate with no greater than 1/2" within 18" of latch mechanism. Fence less than 48" in height in some areas. Horizontals less than 45" in height on fence in some areas. Pool built 1998. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. .2528(a) Maintain 45" between bottom horizontal and next horizontal on fence and/or gate (post-May 2010).
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
No spare pump basket at time of inspection. .2518(e) Provide a spare basket for pump.

View this inspection on the county portal ›

Sep 9, 2019 12 demerits · 3 violations
Inspector comments: POOL IS PERMITTED FOR NIGHT SWIMMING. POOL HAS AQUASTAR 6HP EQ LINE COVERS. AQUASTAR HAS CHANGED THE CERTIFIED FLOW RATE FOR THESE COVERS TO 92GPM. THESE COVERS EXPIRE APRIL 2020. WHEN THE CURRENT COVERS EXPIRE, NEW COVERS MUST BE RATED FOR THE REQUIRED FLOW RATE OF THE CIRCULATION SYSTEM. THE MAIN DRAINS WILL ALSO EXPIRE MARCH 2020. WHEN THESE ITEMS ARE REPLACED, NEW P.D.S.C. PAPERS WILL HAVE TO BE SUBMITTED TO THE HEALTH DEPARTMENT FOR APPROVAL OF THE NEW EQ AND MAIN DRAIN COVERS. BE ADVISED THAT THE EQ LINES CAN BE PLUGGED IN THE POOL AND SKIMMER, WITH THE WATER REMOVED FROM THE LINE, IF THAT IS DESIRED. P.D.S.C. FORMS AND MAIN DRAIN REPLACEMENT WOULD STILL BE REQUIRED.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
OBSERVED CYANURIC ACID RESULT MISSING FROM THE LOG BOOK FOR THE WEEK OF 9/1/2019. CYANURIC ACID, IF USED, MUST BE TESTED AND RECORDED AT LEAST ONCE EVERY WEEK. IT CANNOT BE ALLOWED TO BE HIGHER THAN 100PPM. ALL OTHER TEST RECORDS WERE IN ORDER. NO PERMIT ACTION TAKEN. CORRECT THIS ISSUE.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
OBSERVED 1 WEIR MISSING. THERE ARE 6 SKIMMERS TOTAL. NO PERMIT ACTION TAKEN. REPLACE THE WEIR.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
OBSERVED FENCE TO NOT BE TO CURRENT SPECIFICATIONS. OBSERVED SOME AREAS TO BE LOWER THAN 48 INCHES HIGH (46 INCHES IN SOME LOCATIONS). CONSTRUCTION WAS PRIOR TO 2010. NO PERMIT ACTION TAKEN.

View this inspection on the county portal ›

Apr 16, 2019 4 demerits · 1 violation
Inspector comments: Pool has Aquastar 6HP equalizer line covers. The company that makes the covers has reduces the certified flow rate for these covers from 224GPM maximum to 92GPM when mounted on the pool wall. These covers expire April of 2020. When the covers are replaced, ensure the covers that are installed meet the flow rate requirements for the pump system. Main drains expire in March of 2020. The pool is not currently approved for swimming after sunset or before sunrise. Approval requires a site visit after sunset or before sunrise. CPO has made an appointment with C. Elmore for 9pm on 4/25/2019 for this evaluation.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed fence to have some areas where height is less than 48" due to landscape build-up. (45"-46") Observed some areas with foot holds and with gaps greater than 4". Observed fence horizontal members to be 36 inches apart. Fence was built prior to 2010, no permit action taken. Observed 4 gates to not be in compliance with requirements. Gates are required to be in compliance regardless of the date of fence construction. Observed spring hinges on 3 gates to extend more than 2 inches and to be lower than 45 inches from the ground. Observed gates to have metal mounting bars providing foot holds lower than 45 inches from ground. Observed gates to have horizontal members 36 inches apart, 45 inches apart is required. Observed gaps under the gates greater than 2 inches and gaps greater than 4 inches through the bottom of the gates. Observed 1 gate to have a gap greater than 1/2" within 18 inches of the gate latch. These items must be corrected. I.T.S. Issued, 30 day deadline expires on May 16th 2019. Contact C. Elmore when corrections are made. 704-507-6814.

View this inspection on the county portal ›

Dec 6, 2018 12 demerits · 3 violations
#3 · Water quality: pool water pH −6
Observed pH to be 7.0. pH corrected to 7.8
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed gaps at some points greater than 4". Pool built before 2010. No permit action taken.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Observed hot water in bathrooms to be 114F. 110F is the maximum temperature in the pool rules for water fixtures.

View this inspection on the county portal ›

Apr 4, 2018 16 demerits · 5 violations
Inspector comments: 30 day ITS for weirs, skimmer baskets, windows open greater than 4", spare pump basket. Annual permit will NOT be renewed on 5/1/18 until items are in compliance. Permit will not permit ‘Night Swimming’ until an onsite visit is conducted before dawn or after dusk to meet compliance with new regulation. It can still be open during daylight without an onsite visit. This includes: Pool illumination is sufficient to illuminate the main drains of the pool and the deck area of the pool so that it is visible at all times the pool is in use. Lighting fixtures are of such number and design to illuminate all parts of the pool, the water, the depth markers, signs, entrances, restrooms, safety equipment and the required deck area and walkways. The illumination is sufficient so that the floor of the pool can be seen at all times the pool is in use. Please contact Marie Daley at 704-507-6806 directly to schedule a visit to verify lighting is sufficient and this condition is met to update permit to allow ‘Night Swimming’.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Some leaves and debris in skimmer baskets. Keep clean. Operator cleaned. Corrected. 1 weir missing. Replace with functional weir. Skimmer basket cracked. Keep in good repair. *30 Day Intent to Suspend item. Contact Marie Daley at 704-507-6806 when items are addressed to lift ITS. **Note: Annual permit will NOT be renewed on 5/1/18 until items are in compliance.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Handrails at both entrances cracked. Keep in good repair.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Windows from club house open greater than 4". Ground level windows shall not open greater than 4" on to pool deck or child protected by audible alarm. *30 Day Intent to Suspend item. Contact Marie Daley at 704-507 -6806 when items are addressed to lift ITS. **Note Annual permit will NOT be renewed on 5/1/18 until items are in compliance. Fence not 48" in height, built in '98. Pool fence shall be at least 48" in height measured from outside of barrier. *No permit action
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Provide spare pump basket. Pump Pentair Challenger CHII-NI-3F-3HP *ITS item
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Chemicals stored on floor. Keep stored off floor. Water on floor in pump room. Pump room floor shall be kept dry and free of standing water.

View this inspection on the county portal ›

Nov 6, 2017 22 demerits · 6 violations
Inspector comments: 17) Floor by handrail near fire pit side starting to crack, create hole. Leep in good repair and eliminate possible trip hazard.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
No main drain check on current page logs. Header for main drain on previous pages. Educated opertaor on documenting main drain checks (in good repair, easily visible) daily. Operator added main drain checks to logs. Corrected.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Some leaves and debris in skimmer baskets. Keep clean. Operator cleaned. Corrected. 1 weir missing. Replace with functional weir.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Handrails at both entrances cracked. Keep in good repair.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Gate 1 not self-closing, self latching. Ensure gates self-close, self latch. **Intent to Suspend item Contact Marie Daley at 704-507-6806 when corrected. Gaps at back and side gates greater than 4" built prior to 2010. Eliminate gaps.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Some chairs within 6' of pool. Maintain 6' deck clearance free of trip hazards. Operator moved. Corrected. Deck by handrail near fire pit side starting to crack, creating hole. Keep in good repair and eliminate possible trip hazard.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Provide spare pump basket.

View this inspection on the county portal ›

Feb 21, 2017 10 demerits · 3 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed 2 of 6 weirs missing. Replace missing weirs.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed handrails at both sets of pool steps beginning to crack. Repair or replace handrails.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed cracking/ pitting on pool deck around gazebo with swing. Repair.

View this inspection on the county portal ›

Nov 22, 2016 10 demerits · 3 violations
Inspector comments: Issued intent to suspend for #16
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed minor amount of debris in skimmers. Also observed 1 weir missing. Replace missing weir.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed handrails at both sets of steps cracked. Consider covering or replacing.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed gap greater than 4 inches underneath gate at back left corner of pool area. Eliminate gap.

View this inspection on the county portal ›

Jun 21, 2016 4 demerits · 1 violation
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed two weirs missing. Replace missing weirs. Keep weirs free of debris. Observed minor debris in skimmers.

View this inspection on the county portal ›

May 20, 2015 14 demerits · 4 violations
Inspector comments: Intent to suspend issued:16)
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Plastic coating on handrails cracked. Maintain smooth and in good condition to elminate risk of someone cutting themselves.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Not all gates with at least 54" latch height or 3" down with no openings > 1/2" within 18" of the release mechanism. Make gates complaint.Gap > 4" under one of the gates. Some sections of fence < 48" high.
#21 · Premises: pool and deck lighting provided at pools that operate at night −4
Underwater light not firmly attached to wall. Install light securely to pool wall. Corrected by operator.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter stuck. Repair or replace.

View this inspection on the county portal ›

Nov 3, 2014 4 demerits · 1 violation
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed leaves and debris in skimmers. Keep skimmers free of debris.

View this inspection on the county portal ›

May 29, 2014 10 demerits · 2 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed minor amount of debris in skimmers. Keep skimmers free of debris.
#22 · Premises: emergency telephone provided −6
Observed emergency phone inoperable. Opertaor was unable to hear what inspector was saying. Corrected onsite.

View this inspection on the county portal ›

Oct 16, 2013 14 demerits · 3 violations
Inspector comments: Immediate suspension issued for #22 and 24.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed debris in skimmers. Keep skimmers free of debris.
#22 · Premises: emergency telephone provided −6
Emergency phone connected to 911, but operator could not hear inspector.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed pump inoperable and dismantled on pumproom floor.

View this inspection on the county portal ›

Jun 26, 2013 4 demerits · 1 violation
Inspector comments: General Comment: Back left gate does not self-close as easily as it should. Tighten springs.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Some skimmer baskets with dead frogs and debris. Clean on a regular basis.

View this inspection on the county portal ›

Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “PRESERVE AT BALLANTYNE, THE” or State ID 2060530091). Inspection type (routine vs. follow-up) is not published in the county's data.