‹ Back to search

24demerits

COFFEY CREEK APARTMENTS

2208 YAGER CREEK DRIVE, Charlotte, NC 28273
Year-Round Swimming Pool · NC permit/State ID 2060530092
Latest result24 demerits
Last inspectedAug 27, 2026
Inspections on record20
On record sinceAug 14, 2013

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

01836 Aug 14, 2013: 22May 28, 2014: 32Nov 5, 2014: 18Apr 30, 2015: 26Dec 7, 2015: 28Jun 2, 2016: 12Oct 27, 2016: 36Jun 13, 2017: 22Jun 13, 2018: 16Aug 6, 2018: 14Jan 8, 2019: 30Aug 26, 2019: 10Feb 12, 2020: 8Jun 17, 2021: 16Oct 12, 2021: 12Apr 4, 2022: 30Aug 1, 2024: 8Jul 3, 2025: 20Jun 3, 2026: 18Aug 27, 2026: 24
Aug 14, 2013Lower is betterAug 27, 2026

Inspections & violations

Aug 27, 2026 24 demerits · 6 violations
Inspector comments: Conducted inspection with CPO. CPO states pool is currently closed but EHS did not observe signs on open gate. Intent to suspend issued for missing floor fitting and inconsistent records. Call EHS Devon when items have been corrected 7049981122. Items must be corrected within 30 days or permit may be suspended. EHS recommends lowering chlorine for bather comfort. Permit Restriction: Flow meter required. Flow required at 100 gpm to meet turnover and not exceed restriction of returns. Flow greater than 119 gpm exceeds the main drains. Suction Hazard. Note - Aftermarket pump installed with model SPX3206Z1VSPE. Same pump/pump curve as SP3206VSP & SP32950VSP per Hayward Night swimming expired and property not seeking re certification. Const. Date: 5/1/1990 Rope Length: 30'0 Night Swim?: No
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. .2535(11) Provide weekly recordings for cyanuric acid and total alkalinity. Records inconsistent and missing daily maintenance drain checks. Intent to suspend item.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
.2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. Observed 1 missing inlet cover on pool floor. Replace. Intent to suspend item.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Lifesaving equipment should be conspicuously and conveniently located. Ring buoy rope tangled and inaccessible. Operator corrected. .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Ring buoy rope too long. Operator shortened to approved 30ft. No permit action.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing, self-latching. Front gate not self latching. Operator repaired. No permit action. .2528(a) Ground level windows shall not open greater than 4" on to pool deck or child protected by audible alarm. Some windows missing limiters. Operator replaced. No permit action.
#18 · Premises: lifeguards present or warning signs posted −4
Property not approved for night swimming and are not seeking to renew. Change signage from hours of 10am to 10pm to Dawn to Dusk.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Chemical storage in pump room. Pool built 1990. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.

View this inspection on the county portal ›

Jun 3, 2026 18 demerits · 4 violations
Inspector comments: Issued immediate suspension for pH at 6.8. Please call James Bjorneboe at 704-507-6820 when all items have been corrected to schedule re-visit.
#3 · Water quality: pool water pH −6
Observed pH at 6.2. Maintain between 7.2- 7.8 .2535(1) Maintain pH at 7.2 to 7.8.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed 1 of 4 weirs missing. Replace. .2518(k) Replace missing weirs.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
Observed 1 missing inlet cover on pool floor. Replace. .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed fence less than 48” inches places due to landscaping. Ensure all areas of fence are a minimum of 48” inches height. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier.

View this inspection on the county portal ›

Jul 3, 2025 20 demerits · 6 violations
Inspector comments: Issued permit. No night swimming unless verification is sent to Marie Daley at 704-507-6806 Changed to “A” Open for Business Permit Restriction: Flow meter shall remain operable. Flow required at 100 gpm to meet turnover and not exceed restriction of returns. Note - Aftermarket pump installed with model SPX3206Z1VSPE. Same pump/pump curve as SP3206VSP & SP32950VSP per Hayward. Inspection with Ka’son Crawford
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Récords missing daily maintenance. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Operator recorded and corrected.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
One ladder missing stair. .2521 Install ladders per manufacturer instructions. Operator replaced stair and corrected.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Buoy needing rope. Rope available. .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Operator attached rope to buoy and cut to 30’ corrected.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Door onto pool deck not latching or alarmed at time of inspection. .2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. Operator tightened and adjusted to self close, self latch. Corrected.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Chemical storage in pump room. Pool built 1990. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Toilets leaking in both restrooms. .2526(m) Keep restrooms and fixtures clean and in good repair.

View this inspection on the county portal ›

Aug 1, 2024 8 demerits · 3 violations
Inspector comments: 23-Feeder is plugged directly into wall outlet. Appears to shut off with pump, but ‘flow’ light remains on. Advised to monitor and ensure that feeder shuts off chemical feeding if pump is not in use at all times. Issued permit. Changed to “A” Open for Business Operator does not request Night Swimming Pump is aftermarket, but verified SPX3206Z1VSPE is the same pump curve. From Amada with Hayward in email to Katie Rudisill stated “I can confirm that power end SPX3206Z1VSPE is the correct power end for the SP3206VSP & SP32950VSP.” Flow required at 100 gpm
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
One ladder loose and stair wobbling. Keep tight. .2521 Install ladders per manufacturer instructions.
#18 · Premises: lifeguards present or warning signs posted −4
Lifeguard signage not meeting letter height at time of inspection. .2530(c) Provide "Warning - No Lifeguard on Duty" in 4" lettering. Operator got sign and posted. Corrected.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Chemical storage moved to separate room. No ventilation. Pool built 1990. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room.

View this inspection on the county portal ›

Apr 4, 2022 30 demerits · 8 violations
Inspector comments: Immediate Suspension issued for water quality. Contact Marie Daley at 704-507-6806 when pool is in compliance to lift suspension. Pool must remain closed until suspension is lifted by Health Dept. “E” Immediate Suspension status Other permit items to verify on return visit: records (accurately kept), spare pump basket and chlorinator (working properly and shuts off with pump) Inspection with Will Taylor
#2 · Water quality: disinfectant residual provided by −6
0 ppm chlorine in pool at time of inspection. .2535(4) Maintain chlorine at least 1.0 ppm. *Immediate suspension item. Contact Marie Daley at 704-507-6806 when in compliance to lift suspension. Pool must remain closed with signage posted until suspension is lifted by Health Dept.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Records showing different entries than water quality. Keep accurate and close pool when out of range. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. *Permit item
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Paper towels covering main drain at time of inspection. .2537(14) Keep pool surface and pool floor free of debris.Operator cleaned and corrected.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Skimmers with debris at time of inspection. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Operator emptied and corrected.
#23 · Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 −4
Feeder not shutting off with pump and having issues per operator at time of inspection. .2535(6) Automatic chlorine and bromine feeder pumps shall be automatically prevented from operating when the circulation pump is not in operation. .2535 Automatic acid feeder shall be automatically prevented from operating when the circulation pump is not in operation. .2535(6) Provide NSF approved automatic chlorinator installed per manufacturer instructions. *permit item
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Unable to locate spare pump basket. .2518(e) Provide a spare basket for pump. *permit item
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Chemicals stored in pump room. Items around piping and equipment. Water on pump room floor. Pool built 1990. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. .2533(d) Pump room floor shall be kept dry and free of standing water.
#27 · Equipment room: filter backwash discharged through an air gap −2
Discharge pipe has slit, but no air gap at backwash. .2513(b) Filter backwash shall be discharged through an air gap.

View this inspection on the county portal ›

Oct 12, 2021 12 demerits · 5 violations
Inspector comments: Verified lighting for night swimming. All lighting working at time of inspection. Pool not heated Inspection with Ike Baxter No signature due to COVID
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Skimmers with debris at time of inspection. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Operator emptied and corrected.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Ladder step by 5' loose. Keep tight and in good repair. .2521 Install ladders per manufacturer instructions.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Chemicals stored in pump room. Items around piping and equipment. Pool built 1990. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
#27 · Equipment room: filter backwash discharged through an air gap −2
Discharge pipe has slit, but no air gap at backwash. .2513(b) Filter backwash shall be discharged through an air gap.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Toilet paper holder in men's restroom broken at time of inspection. Toilet observed soiled. .2526(m) Keep restrooms and fixtures clean and in good repair.

View this inspection on the county portal ›

Jun 17, 2021 16 demerits · 6 violations
Inspector comments: Issued permit. Pool and deck lights on and working. Night Swimming Approved. Emergency phone has been repaired and rings back to pool phone. Doors onto pool deck corrected to self-close, self-latch or have alarm. Changed to "A" Open for Business. Inspection with Mike Baxter No signature due to COVID
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Ladder by 5' loose. Keep tight and in good repair. Ladder more than 6" from wall at bottom. .2521 Install ladders per manufacturer instructions. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Fence bolts have been removed creating gaps greater than 4" and fencing section able to be removed. .2528(a) Provide no openings in fence and/or gate greater than 4"x4". Operator bolted and secured to close gaps. Corrected. Landscaping making fence height 44" in some sections. Pool built '90. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
No backflow prevention device on deck hose bib. .2522(h) Provide hose bibs with backflow prevention so that all arears of deck can be reached with a 100 ft hose.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Chemicals stored in pump room. Items around piping and equipment. Liquid chemicals over dry chemicals. Pool built '90. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. .2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up.
#26 · Equipment room: valves and pipes identified by color codes or labels −2
Labeling faded on equipment piping at time of inspection. .2518(d) Piping and valves shall be labeled with color codes or labels. Operator labeled and corrected.
#27 · Equipment room: filter backwash discharged through an air gap −2
Discharge pipe has slit, but no air gap at backwash. .2513(b) Filter backwash shall be discharged through an air gap.

View this inspection on the county portal ›

Feb 12, 2020 8 demerits · 3 violations
Inspector comments: 22) Emergency operator stated static was in the line, but able to hear and connect. Recommended addressing in case of emergency. Verified lights come on for Night Swimming condition of permit.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Skimmers with debris at time of inspection. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Operator emptied and corrected.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Ladder by 5' loose and missing rubber cap. Keep tight and in good repair. .2521 Install ladders per manufacturer instructions.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Chemicals stored in pump room. Items aroung piping and equipment. Pool built '90. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.

View this inspection on the county portal ›

Aug 26, 2019 10 demerits · 3 violations
Inspector comments: ITS for windows onto pool deck and pool signage. Updated CPO to Mike Baxter, expires 5/2024.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Windows onto pool deck observed opening greater than 4" onto pool deck, from clubhouse. .2528(a) Ground level windows shall not open greater than 4" on to pool deck or child protected by audible alarm. **30 Day Intent to Suspend item. Contact Marie Daley at 704-507-6806 when corrected to lift ITS.
#18 · Premises: lifeguards present or warning signs posted −4
Pool signage missing "swimming" verbiage. .2530(c) Provide "Children should not use the swimming pool without adult supervision." in 1" lettering. **ITS item
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Chemicals stored in pump room. Pool built prior to 2004. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.

View this inspection on the county portal ›

Jan 8, 2019 30 demerits · 8 violations
Inspector comments: 30 Day Intent to Suspend (ITS) for records, pipe opening, gate self-latching and trip hazard (damaged deck drain). Contact Marie Daley at 704-507-6806 when in compliance to lift ITS. General comment: Pool signage misisng word "swimming" in "Children should not use the swimming pool without adult supervision." in 1" lettering. If pool signage is replaced correct to exact verbage. This item does not warrant ITS due to contaxt of rule and lack of severity.
#3 · Water quality: pool water pH −6
pH 7.0 at time of inspection. .2535(1) Maintain pH at 7.2 to 7.8. Operator corrected.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Records indicated pH of 7.0 and no maintenance/correction. No maintenance recorded for multiple months. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. **30 Day ITS item
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Skimmer basket with leaves. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Operator emptied. Corrected.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
Gray PVC pipe with no fitting/cover/inlet by side ladder. .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. **30 Day ITS item.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Door from clubhouse not latched, closed at time of inspection. .2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. Audible alarm in place. Operator closed. Corrected. Gate not self-latching. .2537(b) All gates and doors shall be self-closing, self-latching. **30 Day ITS item (for gates).
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
White plastic draining material cracked/has hole greater than 1/2". .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. **30 Day ITS item
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed some standing water under pump. 2533(d) Pump room floor shall be kept dry and free of standing water. Chemicals stored in pump room. Pool built prior to 2004. Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
Restroom hose bibb does not have back flow preventer. .2512(b) Water introduced into the pool, either directly or by the circulation system, shall be supplied through an air gap, anti-siphon vacuum breaker, or backflow preventer.

View this inspection on the county portal ›

Aug 6, 2018 14 demerits · 5 violations
Inspector comments: ITS for doors and gate latch. Windows may not open greater than 4" onto pool deck.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Some main drain checks missing on records. Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Operator added main drain checks. Corrected.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Ladder loose. Keep tight and in good repair.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Latch height on back gate 50". Ensure latch height is at least 54" from ground. *30 Day Intent to Suspend item Inside door not self-closing, self-latching at time of inspection. Ensure doors self-close, self-latch or have audible alarm. *30 Day Intent to Suspend item Contact Marie Daley at 704-507-6806 to lift ITS when issues are addressed.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Chemicals stored in equipment room. Store separately. Pool built 1990.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Provide backflow prevention device on hose bibb in restroom.

View this inspection on the county portal ›

Jun 13, 2018 16 demerits · 3 violations
#2 · Water quality: disinfectant residual provided by −6
Initial Cl reading of zero. Corrected during inspection to read 4 ppm
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed staining and chipping on the pool plaster
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Throw rope measured 60'. Rope cut to 30' during inspection

View this inspection on the county portal ›

Jun 13, 2017 22 demerits · 5 violations
Inspector comments: 2 - Chlorine was so high it wasn't showing on test. Once spa inspection was done I retested and it showed 10+.
#2 · Water quality: disinfectant residual provided by −6
Chlorine test only showing 0.2 ppm. Maintain at 1 ppm or higher. Corrected during inspection.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Wall tile at stairs still missing.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Throw rope was 50'. Maintain at 30'. Corrected during inspection.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Leak in piping for spa.
#18 · Premises: lifeguards present or warning signs posted −4
"Children should not use the swimming pool without adult supervision" sign did not have the exact wording. Corrected during inspection.

View this inspection on the county portal ›

Oct 27, 2016 36 demerits · 9 violations
Inspector comments: Immediate Suspension issued for #2. Pool cannot re-open without written approval from the Mecklenburg County Health Department.
#2 · Water quality: disinfectant residual provided by −6
Chlorine @ 0ppm. ** Maintain minimum of 1ppm. Immediate Suspension.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
No pool log entries since 10/20/16. ** A CPO must check pool every day it is open & maintain complete records.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Scum on pool wall tiles. Sand & debris on pool floor. ** Clean. Missing wall tile @ stairs. ** Install.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Skimmer baskets with leaf debris. ** Empty as required.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
Vacuum port attachment in place & hence no protective cap. ** Remove attachment after vacuuming & install cap.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Rope that is part of ring buoy dry rotted. ** Buoy replaced.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Deck drain grates & plastic expansion joint inserts are damaged in numerous areas (sections missing, etc.). ** Replace. Holes for volley ball poles are open. ** Plug/ cap.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Equipment/ chemical room has no natural cross draft ventilation & the forced air vent runs off light switch. ** Forced air vent fan should run continuously.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Hot water at least 114F @ lavatories in restrooms. ** Maximum allowed is 110F.

View this inspection on the county portal ›

Jun 2, 2016 12 demerits · 3 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
15a NCAC 18A .2537 Maintenance and operation. Observed full baskets of debris in the skimmers. CDI-The baskets were cleaned and emptied by the person in charge.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
15A NCAC 18A .2537 Maintenance and Operation. Observed no plug for the vacuum port in the pool. CDI-The person in charge had properly plugged in the port.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
15A NCAC 18A .2537 Maintenance and Operation. Observed damaged deck drains in area outside of the required deck space of 6 feet. Observed deterioraton fo the expansion joint fill ins. Observed holes in the ground used for volleyball poles and needs to be covered properly when not in use.

View this inspection on the county portal ›

Dec 7, 2015 28 demerits · 7 violations
Inspector comments: #17 Plug volley ball net holes for poles in pool deck. IMMEDIATE SUSPENSION ISSUED FOR #22.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Soil on pool wall tiles. ** Clean. Sediment (& some worms) on pool floor. ** Clean.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Skimmer baskets full of leaves. ** Empty as needed. CDI.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
Two NO DIVING markers spaced 29' a part. ** Maximum distance is 25'. Install additional marker.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
One floor inlet missing part of fitting. ** Correct. Vacuum port extension still in place on pool wall. ** Part removed & protective plug put in place as required while EHS on-site.
#21 · Premises: pool and deck lighting provided at pools that operate at night −4
Pool wall light not secured at bottom. ** Correct.
#22 · Premises: emergency telephone provided −6
Emergency phone not working. Address & phone # not posted @ emergency phone. ** Resolve/ correct.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Equipment/ chemical room floor wet due to leak @ spa circulation pump. ** Resolve. No natural cross draft ventilation & forced air vent fan works off light switch. ** Provide.

View this inspection on the county portal ›

Apr 30, 2015 26 demerits · details not yet loaded

Violation details for this inspection are not yet loaded on this site. We're still importing older records — check the official county portal for the full report.

Nov 5, 2014 18 demerits · details not yet loaded

Violation details for this inspection are not yet loaded on this site. We're still importing older records — check the official county portal for the full report.

May 28, 2014 32 demerits · details not yet loaded

Violation details for this inspection are not yet loaded on this site. We're still importing older records — check the official county portal for the full report.

Aug 14, 2013 22 demerits · details not yet loaded

Violation details for this inspection are not yet loaded on this site. We're still importing older records — check the official county portal for the full report.

Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “COFFEY CREEK APARTMENTS” or State ID 2060530092). Inspection type (routine vs. follow-up) is not published in the county's data.