4demerits
SLEEP INN
6300 BANNER ELK DR., Charlotte, NC 28216
Year-Round Swimming Pool · NC permit/State ID 2060530103
Latest result4 demerits
Last inspectedJul 17, 2026
Inspections on record17
On record sinceSep 16, 2013
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Sep 16, 2013Lower is betterJul 17, 2026
Inspections & violations
Jul 17, 2026 4 demerits · 1 violation
Inspector comments: Inspection conducted with Ronak Patel.
Signage was corrected during the inspection.
New salt cells installed. Two Hayward T-Cell 9 Salt Cells.
Permit issued.
#18 · Premises: lifeguards present or warning signs posted −4
.2530(c) Provide "Adults should not swim alone." in 1" lettering.
.2530(c) Provide "Children should not use the swimming pool without adult supervision." in 1" lettering.
Correct signage was not posted. Signs were posted with the correct wording and size during the inspection. CDI
May 24, 2022 4 demerits · 1 violation
Inspector comments: Inspection conducted with Ronak Patel.
Pool recently repainted, observed new SDX2 main drains installed. Equalizer lines plugged at wall in in the only skimmer for the pool. New Hayward W3S220T sand filter replaced old cartridge filter. Main drain, skimmer, return lines all 2” lines. 5 Returns observed.
Operator plans to use salt. Approved to install two Hayward Cell-9 salt cells. Currently using existing erosion feeder.
Permit issued.
Paper permit will be available on our website, Meckpools.Charmeck.org in 3–5 business days for your records.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Equalizer line plugged at wall, pop-up cover in skimmer. .2518(k) Skimmers shall be installed per section 8 of NSF Standard 50. Equalizer lines must be abandoned per manufacturer’s requirements. - Corrected. Pop-up cover removed, line plugged.
Jan 21, 2020 50 demerits · 11 violations
Inspector comments: Deck paint starting to peel. Recommend using paint with an aggregate so it is non-slip when repainted.
Body hook heavily rusted. Recommend replacing with a new body hook.
Paper permit expired. Go to our website, Meckpools.Charmeck.org to print the current permit and post in the pool area.
No diving marker cracked. Recommend replacing with a new no diving marker.
Immediate suspension issued.
2)
3)
5)
15)
22)
Contact Will Harrison (704-507-6824) for reinspection when ready.
#2 · Water quality: disinfectant residual provided by −6
Chlorine 0.4 ppm. .2535(4) Maintain chlorine at least 1.0 ppm. - Immediate suspension item.
#3 · Water quality: pool water pH −6
pH 7.0. .2535(1) Maintain pH at 7.2 to 7.8. - Immediate suspension item.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Records stored off site at a sister property. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. - Intent to suspend item.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
New SDX2 main drain covers installed. .2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance. - Immediate suspension item.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Skimmer basket dirty. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Intent to suspend item.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Ring buoy rope heavily knotted, not attached to ring buoy. .2530(a) Provide 14 foot rope attached to ring buoy. - Immediate suspension item.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Main door does not latch. Back door has difficulty latching. .2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. - Intent to suspend item.
Windows all open. Capable of opening > 4". .2528(a) Ground level windows shall not open greater than 4" on to pool deck or child protected by audible alarm. - Intent to suspend item.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Chair too close to pool edge. .2522(a) Provide 5 ft of clear walking space around the pool at all times. - Corrected by operator.
#22 · Premises: emergency telephone provided −6
Emergency phone not functioning. .2530(f) Pool telephone shall be capable of directly dialing 911 or another emergency notification system. - Immediate suspension item.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Chemical storage room fan not functioning. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room.
Pump room fan tied to light switch. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Hot water in the restroom 141.9 F. .2526(i) Water in restrooms shall not exceed 110 F.
Dec 17, 2019 2 demerits · 1 violation
Inspector comments: Please fill out and submit PDSC form that is attached to this email.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed non pool items being stored in pump and chemcal rooms as well as general clutter in chemical room. Eliminate storage of all nonpool items in pump and chemical rooms. Clean out and organize chemical storage room.
Feb 15, 2019 10 demerits · 3 violations
Inspector comments: General Comment: Emergency phone was operable. However, it automatically dials to a relay center. Relay center had Phone number, but not address. Provoded address. Relay Center forwarded to Charlotte Police, not the dispatch. Charlotte Police had address and phone number. Ensure that phone line dials directly to 911 dispatch. Return visit will take place in 7 days to ensure issue is corrected
#3 · Water quality: pool water pH −6
Observed pH at 7.1. Adjusted to 7.3 onsite.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed missing tread on bottum rung of ladder. Replace.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed non pool tems being stored in pump and chemical room. Eliminate storage of non pool items in pump room and chemical room.
Nov 26, 2018 14 demerits · 3 violations
Inspector comments: Issued immediate suspension for inoperable emergency phone (#22)
#3 · Water quality: pool water pH −6
Observed pH at 7.0. Adjusted pH to 7.2 onsite.
#22 · Premises: emergency telephone provided −6
Observed emergency phone inoperable at time of visit. Immediate suspension issued.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed excessive clutter in chemical storage room. Keep storage room clean and orderly. Observed non pool items being stored in the pump room. Eliminate storage of non pool items in pump room.
Feb 8, 2018 26 demerits · 6 violations
Inspector comments: Issued intent to suspend for #5 (records) and #8 (weir).
#3 · Water quality: pool water pH −6
Observed pH at 7.0. Adjusted to 7.2 onsite.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Observed daily written records missing for the past two weeks. Maintain daily written records for pH, chloring and maindrain safety. Maintian weekly written records for total alkalinity and cyanuric acid.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed paint peeling in places on pool floor. Repair.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed weir missing in skimmer. Replace.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed throw rope detached from buoy. Corrected on site.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed non pool items being stored in pumproom and chemical room. Eliminate storage of non pool items in chemical and pump rooms.
Nov 13, 2017 32 demerits · 7 violations
Inspector comments: Issued Immediate Suspension for #2, #3 and #4.
#2 · Water quality: disinfectant residual provided by −6
Observed chlorine at 0.5ppm. Chlorine levels must be at at least 1.0ppm.
#3 · Water quality: pool water pH −6
Observed pH at 6.8. pH must be maintained between 7.2 and 7.8.
#4 · Water quality: water temperature of heated pool −6
Observed pool temperature at 94 degrees. Water temperature in pool should not exceed 90 degrees.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Observed daily maindrain recordings not being kept for November. Maintain daily, written record of main drain safety. Also keep weekly recordings of total alkalinity. No such records observed for November.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed peeling/chipping on pool floor and walls. Repair.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed deck chairs within 5ft of pools edge. Maintain 5ft of deck clearance at all points.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed boxes of tiles being stored in pumproom. Eliminate storage of non-pool items in pump room.
Mar 7, 2017 20 demerits · 5 violations
Inspector comments: Intent to suspend issued.
8)
24)
#2 · Water quality: disinfectant residual provided by −6
No chlorine in the pool. Maintain at least 1ppm free chlorine. Operator had replaced a broken chlorinator line this morning. Corrected to 1ppm.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
CA and TA readings have been the same for months. Check at least weekly Total Alkalinity and Cyanuric Acid, as pool is using stabilized chlorine. Tested by operator.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Pool missing only weir. Install functional weir. - Intent to suspend item.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Provide spare cartridge for cartridge filter. - Intent to suspend item.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Chemicals stored in pump room. Store chemicals in chemical storage room. Corrected by operator.
Gasoline stored in chemical storage room. Store only pool chemicals in chemical storage room. Removed by operator.
Provide either forced air or cross draft ventilation in chemical storage room.
Keep pump room and chemical storage rooms locked when not in use.
Sep 20, 2016 28 demerits · 7 violations
Inspector comments: Significant leak at pool water heater located outside the pump room. Fix leak or bypass water heater.
Immediate suspension issued.
3)
Contact Will Harrison (704-507-6824) when water chemistry is balanced.
#3 · Water quality: pool water pH −6
pH < 6.8. Maintain between 7.2 and 7.8. Operator corrected to > 8.4. - Immediate suspension item.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Observed check marks for Total Alkalinity and Cyanuric Acid checks. Pool using stabilized chlorine. Check and record readings for Total Alkalinity and Cyanuric Acid at least weekly. - Intent to suspend item.
Pool regularly has 7.0 for pH readings with no corrective actions noted. Maintain pH between 7.2 and 7.8.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Pool bottom, walls and steps chipped and pitted. Patch any rough spots and repaint or replaster pool. - Intent to suspend item.
Some of the grouting on wall tiles is gone. Regrout wall tiles. - Intent to suspend item.
Damaged cement around skimmer. Patch and paint. Maintain smooth and in good condition. - Intent to suspend item.
Wet caulking around skimmer opening. Caulking typically will not cure underwater. Drain pool until caulking has set, recaulk or regrout as needed around tiles in skimmer opening - Intent to suspend item.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
All inlet fittings missing. Provide functional inlet fittings. - Intent to suspend item.
#13 · Pool maintenance: contrasting band on steps and benches −4
All tile grout gone. Tile as much as 1.5 inches from leading edge of steps. Provide 2" contrasting color band at leading edge of step or if tiled band maintain tile in good condition within 1 inch of step edge. - Intent to suspend item.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter stuck. Repair or replace.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Hot water > 110F. Maintain at 110F or less.
Feb 3, 2016 38 demerits · 9 violations
Inspector comments: Verified PDSC data matched what was installed. PDSC sheet states two equalizers lines, pool only has one. Permit will not be issued until we have updated form on file.SDX Retro cover installed on equalizer line. Permit will not be issued until A112 cover installed.Immediate suspension issued.3)22)
#3 · Water quality: pool water pH −6
pH < 6.8. Maintain between 7.2 and 7.8. - Immediate suspension item.
#4 · Water quality: water temperature of heated pool −6
Temperature 94.8F. Maintain at no more than 90F. NOTE: THIS IS A REPEAT ISSUE! CALIBRATE OR REPLACE THERMOMETER. Corrected to 85.5F.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Records consistently read 80F for temperature, and consistently below 7.2 for pH with no corrective actions. THIS IS A REPEAT ISSUE! MAINTAIN PH BETWEEN 7.2 AND 7.8 AND CALIBRATE OR REPLACE THERMOMETER. - Intent to suspend item.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Plaster chipping on pool steps and pool floor. Repair.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
Some inlet fittings missing. Install functional inlets.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Table too close to pool. Maintain at least 5 feet clear walkway around pool. Corrected.
#22 · Premises: emergency telephone provided −6
Emergency phone signage with missing city, state and zip code. Refers to a restaurant that no longer exists. Provide accurate signage with correct address and phone number. - Immediate suspension item.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Fan in pump room tied to light switch. Fan shall run continuously. Inadequate ventilation in chemical storage room. Provide forced air ventilation.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Hot water > 110F. Maintain at 110F or less.
Dec 9, 2015 32 demerits · 8 violations
Inspector comments: 8) Equalizer line cover SDX Retro. This cover will need to be replaced with an approved A112 cover installed according to manufacturer's instructions before a permit will be issued this Spring.22) Dialing instructions do not list city, state and zip code. Also states it is located behind a restaurant that no longer exists. Provide correct address information.Verified PDSC form. Pool only has one skimmer and one equalizer line. Provide corrected PDSC form to the Health Deparmtment.Immediate suspension issued.3)4)17)Contact Will Harrison 704-507-6824 when issues have been corrected for a reinspection.
#3 · Water quality: pool water pH −6
pH < 6.8. Maintain between 7.2 and 7.8. - Immediate item.
#4 · Water quality: water temperature of heated pool −6
Temperature 96.6F. 90F is the maximum temperature. Maintain at 90F or less. - Immediate item.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Records show pool is consistently 1ppm Cl and 7.0 - 7.1 pH. Maintain pH closer to 7.4 and Cl of two or three ensure that chemistry is still good when pool is in use. Pool temperature in log was consistently 80F. Get new thermometer.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Weir not securely attached. Secure weir.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
Missing some inlet fittings. Install functional inlets.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
One chair too close to pool edge. Maintain 5 feet clear walkway around pool. Corrected.One windows broken with exposed sharp edge. Replace window - Immediate item.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Fan tied to light switch in pump room. Inadequate ventilation in chemical storage room. Provide continuous cross or forced air ventilation in chemical storage room and equipment room.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Hot water > 110F. Maintain at 110F or less.
Jun 23, 2015 32 demerits · 8 violations
Inspector comments: Ring buoy glue starting to come loose. Recommend replacing ring buoy.Immediate suspension issued.6)22)Contact Will Harrison 704-336-5528 for reinspection once issues have been corrected.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
No checks some Sunday's. Check daily Cl, pH, Temperature and drain covers. No total alkalinity checks. Check at least weekly. - Intent item.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
Equalizer line cover ripped out of the wall. Install A112 approved equalizer line cover. Fill out an updated PDSC form and submit to Health Department if new cover is installed. - Immediate item.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Skimmer missing weir. Install functional weir. - Intent item.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Chair too close to handrail. Maintain at least 6 feet clear walkway around pool and 5 feet around ladders and handrail. Corrected.
#22 · Premises: emergency telephone provided −6
Was very difficult for 911 operator to hear me. Provide functional emergency phone. - Immediate item.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter stuck. Operator unable to fix. Provide functional flow meter. - Intent item.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Inadequate ventilation. Provide either forced air or cross ventilation.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Provide toilet paper on a holder in restroom.
Jan 22, 2015 40 demerits · 9 violations
Inspector comments: 16 - General Comment: Back door propped open. Keep closed.
Immediate Suspension issued for #2 and #3. Once corrected, contact Katie at 704-309-5494 to re-open pool.
#2 · Water quality: disinfectant residual provided by −6
No chlorine in pool. Maintain at least 1.0 ppm. Immediate Suspension issued.
#3 · Water quality: pool water pH −6
Pool pH at 8.4. Maintain at 7.2 to 7.8. Immediate Suspension issued.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Some etching on pool floor and chipping plaster on steps. Keep in good repair.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Records not maintained on Sundays. Record main drain check, temp, chlorine and pH daily.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
One return missing eyeball fitting. Replace.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Rope at 16 ft. Corrected to 14 ft.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Furniture 3 ft to pool. Maintain 5 ft clearance.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Small leak at pump. Repair.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Light tied to fan in pump room and inadequate ventilation in chem storage room. Provide continuous forced or cross ventilation.
Oct 22, 2014 28 demerits · 7 violations
Inspector comments: Immediate Suspension issued for #1 and #22. Contact Katie at 704-309-5494 to re-open once corrected.
#1 · Water quality: water clear enough to clearly see bottom of pool and pool drain −6
Foam on surface of pool so drains not clearly visible. Drains must be clearly visible. Immediate Suspension issued.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Some days missing records; no alkalinity records. Maintain records daily and alkalinity 1 x per week.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Windows open on deck with screens. Open >4" . Maintain 4" or less.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Pool furniture 3 ft to pool. Maintain 5 ft clearance.
#22 · Premises: emergency telephone provided −6
Phone not operable. 911 could not hear. Immediate Suspension issued.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Light tied to fan. No cross/forced ventilation in chem room. Provide continuous forced ventilation or cross.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
No air gap at filter drain line to drain. Provide air gap.
Feb 10, 2014 40 demerits · 10 violations
Inspector comments: Immediate Suspension issued for #3 and #4. Once corrected, contact Katie at 704-309-5494 to re-open.
#3 · Water quality: pool water pH −6
Observed pH at 6.8. Maintain at 7.2 to 7.8. Immediate Suspension issued.
#4 · Water quality: water temperature of heated pool −6
Observed water temp at 96.7 F. Maintain below 90 F. Immediate Suspension issued.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Observed records not maintained on Sundays. No pool temp recorded. Main drain check, chlorine, pH and temp recorded daily.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed damaged plaster at steps. Keep in good repair.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed rope at 16 ft. Corrected to 14 ft. General Comment: Body hook pole at 10 1/2 ft. Required at 12 ft. Correct by 2/24/14.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed chairs 3 ft to pool. Maintain 5 ft clearance.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed cartridge filter with no extra filter. Provide extra filter.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed light and fan on same switch. Fan must run continuous when light turned out.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Observed water >110 F in restroom. Maintain at 110 F or below.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
Observed cartridge drain pipe directly into drain. Provide air gap.
Sep 16, 2013 42 demerits · 11 violations
Inspector comments: Immediate Suspension issued for #2, #15 and #22. Once corrected, contatc Katie at 704-309-5494 to re-open pool. Note: Permit not posted. Post visible on deck. Meckpools.charmeck.orgNote: Extreme humidity present in pool room. Be cautious of mold issues.
#2 · Water quality: disinfectant residual provided by −6
Observed chlorine at 0.6 ppm. Provide at 1.0 ppm or greater. Immediate Suspension issued. Do not place granular in pool.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Observed no log book. Maintain as required.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed skimmer without weir. Replace.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
Observed wall depth markers missing from pool wall at deep end. Replace.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed one ladder rung missing off ladder. Replace.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed damaged ring buoy and rope at 11 ft. Replace buoy with USCG approved and provide 14 ft rope. Immediate Suspension issued.
#22 · Premises: emergency telephone provided −6
Observed phone automatic dial not connecting to 911. Immediate Suspension issued.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed flow meter stuck. Keep operational.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed pump room floor wet. Keep dry.
#26 · Equipment room: valves and pipes identified by color codes or labels −2
Clearly identify pipes with color codes or labels.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Observed water in restrooms >115 F. Maintain at 110 F or below.
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “SLEEP INN” or State ID 2060530103). Inspection type (routine vs. follow-up) is not published in the county's data.