14demerits
CHARLOTTE SWIM ACADEMY
9315 MONROE RD., Charlotte, NC 28270
Year-Round Swimming Pool · NC permit/State ID 2060530108
Latest result14 demerits
Last inspectedFeb 11, 2026
Inspections on record26
On record sinceNov 20, 2013
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Nov 20, 2013Lower is betterFeb 11, 2026
Inspections & violations
Feb 11, 2026 14 demerits · 4 violations
Inspector comments: Inspection completed with Gary Crowley present.
Observed water temperature at 90.6F today. The heater was turned off to facilitate drop in temperature.
Intent to suspend permit for back door that leads onto pool deck not self-latching or audibly alarmed and a missing ‘WARNING NO LIFEGUARD ON DUTY’ sign in 4 inch lettering.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing, self-latching. Observed door at back of pool not self-latching. Intent to suspend permit issued. Correct within 30 days.
#18 · Premises: lifeguards present or warning signs posted −4
.2530(c) Provide "Warning - No Lifeguard on Duty" in 4" lettering. Observed no sign posted. Intent to suspend permit.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Install flow meter on return line per manufacturer instructions. Observed flow meter non-operational.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(a) The equipment room door shall have a permanent lock and be kept locked when not in use by the pool operator. Observed door locked but not shut during inspection.
Nov 6, 2025 10 demerits · 2 violations
Inspector comments: Inspection completed with Gary Crowley present.
#4 · Water quality: water temperature of heated pool −6
.2535(12) Maintain pool temperature at 90 F or below. Observed water temperature at 91.2F. CDI- water temperature adjusted to 90.0F.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Observed flow meter non operational.
Mar 6, 2025 0 demerits · 0 violations
Inspector comments: Inspection completed with Ashley Owens and Gary Crowley present.
Gary indicated one motor has been replaced with an identical motor but no electrical inspection has been completed. E. Freese notified Gary that an electrical inspection must be completed by code enforcement. A follow up will be completed on 3/14 to verify work is completed.
Note: maintain pool temperature at 90.0F or lower.
No violations were recorded for this inspection.
Sep 26, 2024 6 demerits · 1 violation
Inspector comments: Inspection completed with Gary Crowley present.
Observed flow meter non operational.
#4 · Water quality: water temperature of heated pool −6
.2535(12) Maintain pool temperature at 90 F or below. Observed temperature at 91.2. CDI- cold water added to pool while conducting inspection.
Mar 19, 2024 6 demerits · 1 violation
Inspector comments: Inspection completed with Ashley Owens present.
#4 · Water quality: water temperature of heated pool −6
.2535(12) Maintain pool temperature at 90 F or below. Observed temperature at 91.9. CDI- heater turned off. Fresh water added to pool. Water temperature had dropped to 91.5 at end of inspection. Maintain heater off until water temperature is at 90.0F or lower.
Nov 28, 2023 4 demerits · 1 violation
Inspector comments: Inspection completed with Gary Crowley present.
Note: observed temperature of water at 91.0F. Thermostat was adjusted during inspection.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Observed no records being kept since November 19, 2023. The facility has a sign on the door indicating the pool is closed until January 3, 2024. However, observed employees using pool during inspection. EHS recommends maintaining logs if pool is being used in any capacity during closures.
Jan 24, 2023 0 demerits · 0 violations
Inspector comments: 911 operator did not have suite A listed for facility’s address. Contact phone service provider to update address information with 911 to include suite information.
Observed depth markers obstructed by pool toys and equipment. Do not obstruct depth markers. Corrected during inspection by removing objects obstructing depth markers.
Observed excessive activity bins out on pool deck. Ensure only toys that are actively in use are at pool deck edge.
Observed main drains and equalizer line coverings replaced. CPO Gary Crowley indicated the PDSC paperwork will be submitted in a timely manner. EHS Eli Freese is requesting PDSC paperwork be submitted within 10 days or the permit may be suspended.
Inspection completed with Gary Crowley present.
No violations were recorded for this inspection.
Oct 26, 2022 10 demerits · 2 violations
Inspector comments: MAIN DRAIN COVERS AND EQ LINE COVERS WILL REQUIRE REPLACEMENT BEFORE THE END OF FEBRUARY 2023 WHEN THEY EXPIRE. ENSURE THAT THE ITEMS ARE REPLACED AND THAT THE PDSC PAPERWORK IS SUBMITTED AND APPROVED BY THE HEALTH DEPARTMENT BEFORE THAT DEADLINE. BE AWARE THAT THE FLOW RATE FOR WALL MOUNTED AQUASTAR
6HPHAXXX HAS BEEN MODIFIED TO 92 GPM. ENSURE THAT THE COVERS WORK WITH THE FLOW RATE OF THE SYSTEM.
#4 · Water quality: water temperature of heated pool −6
.2535(12) Maintain pool temperature at 90 F or below. Heater was turned off. -CDI
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed some skimmer baskets to be soiled. Items were removed for cleaning. Keep the skimmers clean.
Mar 14, 2022 0 demerits · 0 violations
Inspector comments: NO VIOLATIONS NOTED.
CPO AGREED TO EMAIL COPY OF REPORT
NO SIGNATURE DUE TO COVID-19 PRECAUTIONS.
CONTINUE TO FOLLOW ALL RELEVANT COVID RULES.
No violations were recorded for this inspection.
Sep 22, 2021 6 demerits · 1 violation
Inspector comments: CPO AGREED TO EMAIL COPY OF REPORT
NO SIGNATURE DUE TO COVID-19 PRECAUTIONS.
CONTINUE TO FOLLOW ALL RELEVANT COVID RULES.
OBSERVED 2 NEW MOTORS INSTALLED ON CIRCULATION PUMPS. PUMPS WERE NOT CHANGED. OBSERVED
GROUND WIRES NOT TO BE CONNECTED. NO ELECTRICAL PERMIT OR INSPECTION RECORDS WERE ABLE TO BE FOUND IN THE
MECKLENBURG COUNTY SYSTEM. THIS KIND OF REPLACEMENT, EVEN IF IT IS LIKE FOR LIKE, CURRENTLY REQUIRES ELECTRICAL INSPECTION
AND PERMIT WITH CODE ENFORCEMENT IN ADDITION TO ANY HEALTH DEPARTMENT REQUIREMENTS.
IT IS RECOMMENDED THAT THE FACILITY CEASE OPERATION UNTIL THE INSPECTION AND PERMIT PROCESS CAN BE COMPLETED TO VERIFY
THE ELECTRICAL SAFETY OF THE WORK. IF THE ELECTRICAL PERMIT AND INSPECTION PROCESS ARE NOT COMPLETED PROPERLY BEFORE THE NEXT PERMIT PERIOD, A NEW PERMIT WILL NOT BE ISSUED AND THE FACILITY WILL HAVE TO CLOSE UNTIL THE PROCESS IS COMPLETED.
ELECTRICAL GROUND WIRES WERE RECONNECTED DURING THE INSPECTION BY FACILITY STAFF.
#4 · Water quality: water temperature of heated pool −6
Observed water to be at 90.1F. Heater was shut off and water cooled to 89.9F. CDI
Mar 2, 2021 0 demerits · 0 violations
Inspector comments: NO VIOLATIONS NOTED.
"issuance of a permit by this department does not negate closure required by Executive Order No. 120, 138, 141, 147, or subsequent Orders in effect unless such Orders are rescinded or superseded by another applicable Order.”
NO SIGNATURE WAS OBTAINED DUE TO COVID-19 SOCIAL DISTANCING
RESPONSIBLE PARTY AGREED TO HAVE REPORT EMAILED.
No violations were recorded for this inspection.
Oct 28, 2020 4 demerits · 1 violation
Inspector comments: Heater was reported to be off.
Pool has one door that is not fully self-closing and self-latching. I.T.S. issued. Deadline is 10/27/2020. All doors leading onto the pool deck must fully self-close and fully-self latch. Contact C. Elmore when correction is made at 704-507-6814.
Observed a high degree of static on the 911 phone. Ensure phone does not continue to have static to the point where it makes communication difficult.
“issuance of a permit by this department does not negate closure required by Executive Order No. 120, 138, 141, 147, or subsequent Orders in effect unless such Orders are rescinded or superseded by another applicable Order.”
NO SIGNATURE WAS OBTAINED DUE TO COVID-19 SOCIAL DISTANCING
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed one door onto pool deck not fully self-closing and fully self-latching. Correct the door so that it fully self-closes and fully self-latches. I.T.S. Issued. All pass through doors leading onto pool deck must be fully self-closing and fully self-latching.
Apr 8, 2020 0 demerits · 0 violations
Inspector comments: NO VIOLATIONS NOTED
“Issuance of a permit by this department does not negate closure required by Executive Order No. 120 or subsequent Orders in effect unless such Orders are rescinded or superseded by another applicable Order.”
NO SIGNATURE FOR THIS INSPECTION DUE TO COVID-19 SOCIAL DISTANCING REQUIREMENTS.
No violations were recorded for this inspection.
Nov 7, 2019 4 demerits · 1 violation
Inspector comments: OBSERVED HEATER TO BE TURNED OFF AT THE TIME OF INSPECTION.
POOL HAS AQUASTAR 6HP EQ LINE COVERS. AQUASTAR HAS CHANGED THE CERTIFIED FLOW RATE FOR THESE COVERS TO 92GPM. THESE COVERS EXPIRE FEBRUARY 2023. WHEN THE CURRENT COVERS EXPIRE, NEW COVERS MUST BE RATED FOR THE REQUIRED FLOW RATE OF THE CIRCULATION SYSTEM.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed some skimmer baskets to be soiled with a viscous film. Items were cleaned. No permit action taken.
Jan 9, 2019 20 demerits · 7 violations
Inspector comments: 6 - Pool vacuum pump tied into main filtration system. With vacuum pump on, maximum flow exceeds main drain maximum flow. Vacuum shall never be utilized while filtration pumps are in use. Operator indicated he will disconnect vacuum from system so that that maximum flow of pumps does not exceed drain covers installed.
17 - Storage of children equipment directly next to the swimming pool. Maintain 5 ft. clearance around the pool at all times.
22 - Emergency phone with static. 911 still audible and 911 could hear inspector. Operator indicated he had already purchased a replacement.
29 - Mirrors in restrooms could not be verified as shatterproof. No glass fixtures in restrooms.
.2542 In Pool Exercise Equipment - The position of underwater equipment shall be marked with colored floats attached by a 3/4 inch diameter rope or other movable barrier that surrounds the equipment with a visible perimeter designed so not to entangle or otherwise threaten bather safety. Exercise equipment kept in pool when not in use. Does not meet rule .2542.
Onsite visit for in-field plan review. Equipment matches application submittal except for filters installed (TR140C), return to pool is 4" line to 6" return. Currently a vacuum line is tied into the same system with a separate vacuum pump located on the line. With vacuum pump, VGB max flow of drain covers is exceeded. Operator will not vacuum with filtration pumps on. Operator will permanently disconnect vacuum line from the system so not to present a suction hazard. Operator will have repair made by January 11th. Return visit will be made January 14th to verify completion of work. PDSC form submitted shows correct information without vacuum
pump. Electrical permit was pulled per operator. Inspection has not been called in and will be referred to Code Enforcement. Electrical permit E3469055.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
Some depth markers on deck covered by storage of swim equipment. Keep depth markers visble at all times.
.2523(a) Provide depth markers on pool walls and pool deck next to the swimming pool.
#10 · Pool maintenance: safety ropes with floats and contrasting color bands provided at shallow area breakpoints −2
Breakpoint rope not installed. Rope provided onsite. When full length of pull not in use, assure rope is in place.
.2523(e) Provide a minimum of 3/4 inch diameter safety rope at the breakpoint.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Handrails at steps loose. Keep tight and secure.
.2521 Install ladders per manufacturer instructions.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Some deck drains with damage.
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter not clearly visible. Provide flow meter on return line by next inspection.
.2518(g) Install flow meter on return line per manufacturer instructions.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Pump room floor wet due to leak of chlorinated water line. Repair water leak and keep floor dry.
.2533(d) Pump room floor shall be kept dry and free of standing water.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
Hose bib in restroom on pool deck without backflow prevention.
.2512(a) Water supply serving the swimming pool and all plumbing fixtures shall be an approved water supply.
Nov 7, 2018 6 demerits · 1 violation
Inspector comments: PUMPS HAVE BEEN REPLACED WITH 2 PENTAIR WHISPERFLO XFK-12 PUMPS, 3HP 222GPM.
THE MAIN DRAINS AND EQ COVERS EXPIRE IN DECEMBER 2018.
#4 · Water quality: water temperature of heated pool −6
OBSERVED WATER TEMPERATURE TO BE ABOVE 90.0F. C.D.I. TEMP BROUGHT DOWN TO 90F. PROVIDE A CORRECTIVE ACTION PLANE TO C. ELMORE DETAILING HOW TEMPERATURE COMPLIANCE WILL BE MANAGED GOING FORWARD. THIS ISSUE IS A POTENTIAL CLOSURE ITEMS AND MUST BE ACTIVELY MANAGED.
Mar 1, 2018 14 demerits · 3 violations
Inspector comments: Pool owner reports Main Drains and EQ line covers replaced like-for-like. This matches observations. PDSC form was provided.
#4 · Water quality: water temperature of heated pool −6
Observed water temperature to be 92.0F in the heated pool. Water cannot be more than 90.0F. This is a safety violation. -C .D. I
Temperature corrected to 90F.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Observed daily temperature check not being recorded on log sheet. C.D.I. this was added to log sheet for daily checks.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed flow meter stuck. Repair flow meter.
Nov 13, 2017 20 demerits · 4 violations
#4 · Water quality: water temperature of heated pool −6
Observed water temperature to be 92.1F. This is too warm for a heated pool. The water temperature must be 90.0 or less. Temperature was reduced to 90F and the heater was turned off. Keep temperature at 90F or less.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed skimmer baskets to be badly soiled with bandages and debris. -C.D.I. Skimmer baskets were cleaned.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed 3 ingress/egress doors leading onto the pool deck. They are not currently fully self-closing/self-latching. They must be made fully self-closing/self-latching or they must be alarmed with an audible alarm that sounds upon opening. -I.T.S. Issued, expires 12/13/17.
#22 · Premises: emergency telephone provided −6
Observed 911 phone on the deck to be non-functional. A secondary 911 phone was set up at the reception desk and verified with 911 services. -C.D.I.
Feb 13, 2017 4 demerits · 1 violation
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed minor amount of debris in skimmers. Keep skimmers free of debris.
Dec 1, 2016 4 demerits · 1 violation
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed toys and minor amount of debris .in skimmers. Keep skimmers free of debris
Mar 16, 2016 8 demerits · 2 violations
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Observed daily temperature check made, but not clearly recorded on each daily sheet. Temperature of the pool water is a check that must be made and recorded daily.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed flow meters to be stuck. Repair them.
Sep 30, 2015 4 demerits · 1 violation
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed flow meters to be stuck. Observed small leak at control handle. Repair these items.
Feb 20, 2015 6 demerits · 1 violation
#4 · Water quality: water temperature of heated pool −6
Observed water in pool at 92 degrees. Maintain water in pool at 90 degrees or below. Began adjusting water temperature onsite.
Dec 3, 2014 18 demerits · 4 violations
#4 · Water quality: water temperature of heated pool −6
Pool water 90.7°F. Maintain below 90°F.
#22 · Premises: emergency telephone provided −6
Emergency phone not functioning. Corrected, phone replaced.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter stuck. Repair or replace.
#26 · Equipment room: valves and pipes identified by color codes or labels −2
Pipes recently repainted. Provide labels for pipes.
Mar 25, 2014 20 demerits · 4 violations
#4 · Water quality: water temperature of heated pool −6
Temperature 92°F. Maintain at 90°F or less. Corrected.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
No temperature checks, spotty total alkalinity checks. Check temperature daily and total alkalinity at least weekly.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
One weir missing.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Pool lifeguarded. Ring buoy not necessary. Throw rope on ring buoy 31 feet. Throw rope shall be 50' long.
Nov 20, 2013 10 demerits · 3 violations
Inspector comments: Water is 90°F. This is the maximum allowable temperature.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Missing one weir. Install weir.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Ladder loose. Tighten.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter stuck. Repair or replace.
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “CHARLOTTE SWIM ACADEMY” or State ID 2060530108). Inspection type (routine vs. follow-up) is not published in the county's data.