‹ Back to search

0demerits

PINES AT DAVIDSON, INC, THE

400 AVINGER LN, Davidson, NC 28036
Year-Round Swimming Pool · NC permit/State ID 2060530110
Latest result0 demerits
Last inspectedOct 13, 2026
Inspections on record28
On record sinceDec 11, 2013

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

0816 Dec 11, 2013: 16Mar 3, 2014: 4Nov 3, 2014: 8Mar 18, 2015: 6Sep 28, 2015: 0Mar 31, 2016: 2Dec 1, 2016: 0Jun 15, 2017: 0Dec 13, 2017: 2Mar 28, 2018: 0Nov 6, 2018: 4Nov 28, 2018: 0Jan 16, 2019: 4Dec 2, 2019: 10Mar 19, 2020: 0Oct 21, 2020: 0Jan 27, 2021: 0Dec 9, 2021: 0Apr 7, 2022: 0Nov 15, 2022: 0Feb 21, 2023: 0Dec 4, 2023: 0Mar 28, 2024: 0Dec 5, 2024: 6Feb 10, 2025: 4Sep 29, 2025: 2Mar 5, 2026: 0Oct 13, 2026: 0
Dec 11, 2013Lower is betterOct 13, 2026

Inspections & violations

Oct 13, 2026 0 demerits · 0 violations
Inspector comments: INSPECTION DONE WITH ERIC OAKLEY OF MCHD. NO VIOLATIONS NOTED. MAIN DRAIN COVERS ARE 10 YEAR AQUASTAR COVERS THAT EXPIRE 3/6/2034. CHLORINE WAS GREATER THAN 2.5 PPM. Permit Restriction: Flow meter must remain operable. Flow required at 106 gpm to 300 gpm to meet turnover and flow restriction of the returns.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Mar 5, 2026 0 demerits · 0 violations
Inspector comments: Inspection conducted with CPO Chris Stutts. No issues observed.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Sep 29, 2025 2 demerits · 1 violation
Inspector comments: Inspection conducted with CPO Chris Stutts and Chris Hinson. New pool pump with a VFD. New permit condition that flow meter must remain operable and speed set to read between 106 and 300 GPM. Verified at roughly 140 GPM today.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Standing water on floor by pool filters. .2533(d) Pump room floor shall be kept dry and free of standing water.

View this inspection on the county portal ›

Feb 10, 2025 4 demerits · 1 violation
Inspector comments: Inspection conducted with CPOs Chris Hinson, Chris Stutts, and Gage. Updated CPO and contact info in database. 911 callback number goes to the front desk. Ensure someone is at the front desk whenever the pool is open. Griswold pump not labeled. Verified pump had 7.5 HP motor.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Back door not self-latching. .2537(b) All gates and doors shall be self-closing, self-latching. - Corrected.

View this inspection on the county portal ›

Dec 5, 2024 6 demerits · 1 violation
Inspector comments: Inspection conducted with CPO Stuart McCachern, Chris and Gage. Inspection led by inspector Quinn Kennedy. 911 callback number is main number for the facility. Ensure someone is at the front desk whenever the pool is open. Recommend having phone company update the line so that 911 can call back directly to the emergency phone. Griswold pump not labeled. Verified pump had 7.5 HP motor.
#22 · Premises: emergency telephone provided −6
Emergency phone number posted does not match what 911 has. .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. - Corrected.

View this inspection on the county portal ›

Mar 28, 2024 0 demerits · 0 violations
Inspector comments: Inspection conducted with Stuart McCachern and Justin Hubbard. No issues observed.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Dec 4, 2023 0 demerits · 0 violations
Inspector comments: Inspection conducted with CPO Stuart McCachern. No issues observed. Main drain covers expire 2-1-2017. Will need to replace with ANSI/APSP/ICC-16 2017 approved main drain covers and submit updated Pool Drain/Suction Compliance form to our office for approval prior to drain cover expiration.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Feb 21, 2023 0 demerits · 0 violations
Inspector comments: Inspection conducted with CPO Stuart McCachern. No issues observed.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Nov 15, 2022 0 demerits · 0 violations
Inspector comments: Inspection conducted with inspector Hannah Howard and CPO Stuart McCachern. No issues observed on today’s inspection.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Apr 7, 2022 0 demerits · 0 violations
Inspector comments: Inspection conducted with Stuart McCachern. No issues observed. Permit issued.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Dec 9, 2021 0 demerits · 0 violations
Inspector comments: Inspection conducted with JD Norton. Due to COVID-19 precautions, inspection not signed by the operator. No issues observed.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Jan 27, 2021 0 demerits · 0 violations
Inspector comments: Inspection conducted with David Brown Due to Covid-19 precautions, inspection was not signed by the operator.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Oct 21, 2020 0 demerits · 0 violations
Inspector comments: Inspection conducted with Stuart McCachern. Due to COVID-19 precautions, inspection was not signed by the operator. Pump motor recently replaced. Electrical permit E3830049 obtained and Final Inspection passed 10-12-2020. Ringer on emergency phone doesn't work. Recommend replacing the emergency phone. “Executive Order No. 141 or subsequent Orders are in effect unless such Orders are rescinded or superseded by another applicable Order.”

No violations were recorded for this inspection.

View this inspection on the county portal ›

Mar 19, 2020 0 demerits · 0 violations
Inspector comments: No issues observed.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Dec 2, 2019 10 demerits · 2 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Water level shall be maintained above the level of the overflow trough on gutter. Observed water level below that of overflow gutter. CDI- water added to pool.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed throw rope connected to ring buoy at 51 feet 9 inches. CDI- rope adjusted to 50 feet.

View this inspection on the county portal ›

Jan 16, 2019 4 demerits · 1 violation
Inspector comments: PDSC information verified.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed doors to enclosure not-self closing self-latching near emergency phone. .2537(b) All gates and doors shall be self-closing, self-latching.

View this inspection on the county portal ›

Nov 28, 2018 0 demerits · 0 violations
Inspector comments: Observed automatic feeded shutting off as required with no flow. Intent to suspend lifted.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Nov 6, 2018 4 demerits · 1 violation
Inspector comments: Contact Chris Sells when repairs are complete at 704 576 8678. Pool permit will suspended in 30 days if items are not corrected.
#23 · Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 −4
Observed no indication of no flow to stop automatic feeder. .2535(6) Automatic chlorine and bromine feeder pumps shall be automatically prevented from operating when the circulation pump is not in operation.

View this inspection on the county portal ›

Mar 28, 2018 0 demerits · 0 violations
Inspector comments: Night swiming not verified. EHS suggest the use of pool water to test in place if tap sample. Exelent record keeping. Authorization Inspection: Stacie Rhea Maria Adame Tim Gentry

No violations were recorded for this inspection.

View this inspection on the county portal ›

Dec 13, 2017 2 demerits · 1 violation
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
No soap in men's restroom. Corrected.

View this inspection on the county portal ›

Jun 15, 2017 0 demerits · 0 violations
Inspector comments: Extra toilet paper in restrooms stored in a basket on the floor near the toilet. Recommend storing in a storage closet or off of the floor. Last year's permit posted. Go online to Meckpools.Charmeck.org to print the current permit to post in the pool area.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Dec 1, 2016 0 demerits · 0 violations

No violations were recorded for this inspection.

View this inspection on the county portal ›

Mar 31, 2016 2 demerits · 1 violation
Inspector comments: Caulking used around gutter drains soft and spongy. Use cualking rated for underwater use.Posted permits expired. Go online to Meckpools.charmeck.org to print new permits to post in pool area.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Pump leaking. Fix leak.

View this inspection on the county portal ›

Sep 28, 2015 0 demerits · 0 violations

No violations were recorded for this inspection.

View this inspection on the county portal ›

Mar 18, 2015 6 demerits · 1 violation
Inspector comments: Immediate suspension issued:22) Emergency phone.Please call Will Harrison (704-336-5528) for reinspection once emergency phone has been corrected.
#22 · Premises: emergency telephone provided −6
Emergency phone not functioning. Provide functional emergency phone.

View this inspection on the county portal ›

Nov 3, 2014 8 demerits · 2 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Damage to tiling by gutter overflow grates at deep end. Repair.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Chlorinator does not turn off when power to pump cut off. Repair sensor. Intent to Suspend issued.

View this inspection on the county portal ›

Mar 3, 2014 4 demerits · 1 violation
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
All pool floors shall be kept in good repair. Observed cracked tiling at the deep end of the pool.

View this inspection on the county portal ›

Dec 11, 2013 16 demerits · 4 violations
Inspector comments: Immediate Suspension issued for #2. Once corrected, contact Katie at 704-309-5494 to re-open pool.
#2 · Water quality: disinfectant residual provided by −6
Observed chlorine at 0.6 ppm. Provide at least 1.0 ppm. Immediate Suspension issued.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed some staining around gutter drains. Keep in good repair.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed flow meter installed online from pump. Install on return line.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Observed water in restrooms at 112.2 F. Maintain at 110 F or below.

View this inspection on the county portal ›

Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “PINES AT DAVIDSON, INC, THE” or State ID 2060530110). Inspection type (routine vs. follow-up) is not published in the county's data.