CHARLOTTE HILTON AIRPORT HOTEL
2800 COLISEUM CENTRE DR, Charlotte, NC 28217
Year-Round Swimming Pool · NC permit/State ID 2060530117
Latest result2 demerits
Last inspectedAug 18, 2026
Inspections on record24
On record sinceSep 25, 2013
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Sep 25, 2013Lower is betterAug 18, 2026
Inspections & violations
Aug 18, 2026 2 demerits · 1 violation
Inspector comments: Inspection conducted with CPO Ernesto.
PERMIT RESTRICTION: FLOW METER MUST REMAIN OPERABLE. FLOW SHALL NOT EXCEED 119 GPM DUE TO DRAIN COVER FLOW RESTRICTION. SUCTION HAZARD. NOTE: EXTERIOR DOORS ARE POOL BARRIER PATIO IS NOT PART OF POOL AREA.
Night swimming previously approved.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(d) Pump room floor shall be kept dry and free of standing water.
Observed pool of standing water on pump room floor.
Ensure to keep pump room floor free of standing water.
Jan 5, 2026 12 demerits · 2 violations
Inspector comments: Conducted inspection with CPO Ernesto. All items in compliance by end of inspection. Pool remains in good standing and on A status.
Reminder: Drain covers expire 5/5/2026. Drain covers must be replaced and proper PDSC documentation must be submitted and approved by health department prior to drain cover expiration.
Const. Date: 12/15/1999
Rope Length: 27'0
EQUALIZERS PLUGGED ON
WALL AND INSIDE
SKIMMERNOTE: EXTERIOR
DOORS ARE POOL
BARRIER PATIO IS NOT
PART OF POOL AREA.
#2 · Water quality: disinfectant residual provided by −6
.2535(4) Maintain chlorine at least 1.0 ppm. EHS measured chlorine at 0. CPO found obstruction in chlorinator and removed. Corrected to 1ppm. No permit action.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Ring buoy with rope at 28’. Corrected to 27’. No permit action
Aug 6, 2025 6 demerits · 1 violation
Inspector comments: Conducted pool inspection with CPO Ernesto. All items in compliance by end of inspection. Pool remains in good standing and on A status.
Reminder: Drain covers expire 5/5/2026
Const. Date: 12/15/1999
Rope Length: 27'0
EQUALIZERS PLUGGED ON
WALL AND INSIDE
SKIMMERNOTE: EXTERIOR
DOORS ARE POOL
BARRIER PATIO IS NOT
PART OF POOL AREA.
#22 · Premises: emergency telephone provided −6
.2530(f) Emergency phone shall remain operable. Emergency phone not operational. CPO replaced phone and corrected. No permit action.
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Callback number faded. CPO corrected and re wrote callback number. No permit action.
Jan 29, 2025 12 demerits · 3 violations
Inspector comments: Conducted pool inspection with CPO Ernesto. Pool remains in good standing and on A status.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Ring buoy with rope at 29’. Corrected to 27’. No permit action
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(e) Provide a spare basket for pump. Spare pump basket missing. Operator will have one on order. No permit action.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(d) Pump room floor shall be kept dry and free of standing water. Standing water present around pump. Repair source of leak.
.2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. Some chemicals stored in pump room. Move to designated chemical storage room.
Jan 17, 2024 30 demerits · 6 violations
Inspector comments: Pool inspection conducted with CPO Kenneth Smith. Immediate suspension issued for
.2535(2) Main drains must be clearly visible from the pool deck. Drains not visible due to foggy water. Water foggy due to CPO correcting chemicals. Ensure pool is clear enough to see bottom and pool drains.
.2535(4) Maintain chlorine at least 1.0 ppm. EHS measured chlorine at 0.
.2535(1) Maintain pH at 7.2 to 7.8. EHS measured pH at 6.8.
#1 · Water quality: water clear enough to clearly see bottom of pool and pool drain −6
.2535(2) Main drains must be clearly visible from the pool deck. Drains not visible due to foggy water. Water foggy due to CPO correcting chemicals. Ensure pool is clear enough to see bottom and pool drains. Immediate suspension item.
#2 · Water quality: disinfectant residual provided by −6
.2535(4) Maintain chlorine at least 1.0 ppm. EHS measured chlorine at 0. Immediate suspension item.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. EHS measured pH at 6.8. Immediate suspension item.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(10) Provide test kit capable of measuring disinfectant level, cyanuric acid and total alkalinity. All chemicals in test kit expired. Chemicals must be replaced with in date products. Intent to suspend item.
.2535 (11) The pool operator shall inspect the pool at least daily and maintain written records. Some daily records missing. Ensure daily records are kept when pool is open and indicate if pool is closed.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Ring buoy with rope at 28’. Corrected to 27’.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2534(6) Provide sufficient lighting in chemical storage room. Light out in chemical storage room
Oct 10, 2023 32 demerits · 8 violations
Inspector comments: Inspection conducted with operator Kenneth Smith. Immediate suspension of permit issued due to inoperable emergency phone and ring buoy rope too short. Once items are corrected, call Hope McIntosh at 980-229-7549 to request a re-visit. Pool closed with signs posted during visit. Pool must remain closed with signs posted until permit is re-instated. At that time, a 30-day intent to suspend the permit may be issued for other permit items including doors not self-latching.
Note: upon arrival, chlorine pucks observed in both skimmer baskets which were removed by operator. Chlorine must be provided to the pool through the in line chlorination system. Chlorine placed into skimmers is a risk to swimmers and can result in bodily injury. If chlorine must be added to pool to shock, the pool must remain closed until chlorine levels are safe for swimmers. If in line chlorination system is not sufficient to maintain 1.0 ppm chlorine residual in the pool, have the system evaluated to determine if chlorinator is properly sized and operating properly.
#2 · Water quality: disinfectant residual provided by −6
G.S. 130A-2(3) Chlorine added directly to swimming pool. Chlorination must occur through chlorinator. Eliminate direct hazard to public. EHS observed chlorine tablets in skimmer basket. Operator removed but noted that in line chlorinator was not always effective. Chlorine must be added to the chlorinator - another chlorinator may be required to maintain chlorine residual.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Lifesaving equipment should be conveniently located. Ring buoy rope tied/tangled such that it is not accessible for immediate use.
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Ring buoy rope at 26’5”. Required length 27’.
*immediate suspension item
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. Various double doors leading directly into pool room unlocked/unlatched and do not latch when shut.
Intent to suspend item.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(b) Provide at least 5 ft of clear walking space around the pool at all times. Chairs and tables less than 5’ from pool edge.
#22 · Premises: emergency telephone provided −6
.2530(f) Emergency phone shall remain operable. Emergency phone inoperable - dead line. *immediate suspension item.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2534(6) Provide sufficient lighting in chemical storage room. Light out in chemical storage room
#26 · Equipment room: valves and pipes identified by color codes or labels −2
.2518(d) Piping and valves shall be labeled with color codes or labels. Pipework has been replaced - missing labeling.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(j) Provide soap and soap dispenser, no glass, at each sink. Observed ceramic tissue dispenser in use in bathroom. Unable to determine if shatterproof. Ensure items in bathrooms used by the pool are shatter proof.
Feb 10, 2023 16 demerits · 4 violations
Inspector comments: Inspection conducted with Fernando Klahn.
Intent to suspend the permit issued due to inoperable flow meter and entry door not self latching when shut.
Contact Hope McIntosh at 980-229-7549 once items have been corrected or EHS will return within 30 days. If items not corrected by 30 day deadline, permit will be suspended.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions. Loose ladder on pool side nearest shower. Repair/tighten.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Ring buoy with rope at 28’. Corrected to 27’.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. Left side door of double door set nearest to fitness area leading from patio area does not self latch when shut.
Intent to suspend item.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Flow meter not operational during inspection. Repair or replace.
Intent to suspend item.
Nov 18, 2022 6 demerits · 1 violation
#4 · Water quality: water temperature of heated pool −6
Observed pool water over 90F
.2535(12) Maintain pool temperature at 90 F or below.
Heater turned off
Mar 18, 2022 10 demerits · 3 violations
Inspector comments: Observed emergency phone call back going to dial by number menu. Emergency phone must dial back the emergency phone for the front desk with no menu.
Intent to suspend issued for recordkeeping.
Facility has 30 days to make corrections to phone and maintain proper record keeping or the pool permit will be suspended. Contact Chris sails when repairs are complete at 704 576 8678.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Observe the records only taken five days a week. Pool open 7days a week.
Intent to suspend.
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observe flow meter stuck.
.2518(g) Keep flow meter operational.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed chemical storage room door unlocked
.2533(a) The equipment room door shall have a permanent lock and be kept locked when not in use by the pool operator.
Oct 11, 2021 20 demerits · 5 violations
Inspector comments: General Comment: Flowmeter installed before the chlorinator in pump room.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Observed main drain check missing for the last several days. Ensure daily written are being recorded daily.
.2535 (11) The pool operator shall inspect the pool at least daily and maintain written records.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed debris in skimmers. Keep skimmers free of debris.
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed throw rope detached from ring buoy. Corrected on site.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed door leading to pool propped open at time of inspection. Corrected on site.
#26 · Equipment room: valves and pipes identified by color codes or labels −2
Observed some pipes in pump room not labeled. Label all pipes in pump room.
.2518(d) Piping and valves shall be labeled with color codes or labels.
Jun 17, 2021 30 demerits · 8 violations
Inspector comments: Permit re-instated from previous suspension. All items noted previously corrected. Permit issued for night swimming.
Pool heater turned off at time of inspection.
23 - New chlorinator installed meeting requirements for chlorine production for pool. 300-29x chlorinator. No flow meter installed. Install flow meter per mfg. requirements to meet NSF requirement. Given until next inspection to install due to backorder time. Permit action will be taken if not corrected.
16 - Magnetic lock on two doors from pool deck. Ensure battery back-up installed. Did not verify. Operator stated provided.
Chris Sutter present during the inspection. No signature due to covid restrictions.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Log book missing record for main drain checks. Maintain daily record keeping for main drains. Cyanuric acid not recorded. Chlorine tablets with stabilizer. Record cyanuric acid weekly.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
One ladder with step rung >6" from pool wall. Maintain between 3" and 6" between ladder rung and pool wall.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
New rope for ring buoy provided at 50 ft. Corrected to 27 ft during the inspection.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Small crack on coping near handicap chair. Continue to monitor and repair as needed.
#22 · Premises: emergency telephone provided −6
No dialing instructions or phone number posted at pool phone. Corrected during the inspection. Phone dials back to the front desk who has 24-hour attendant.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Pump gasket leaking. Continue to monitor and repair if worsens. Does not appear to be affecting pool chemistry or quality.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Floor wet in pump room due to leak at chlorinator. Keep pump room floor dry.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Soap dispenser not operational and faucet leaking in women's restroom. Soap provided. Keep fixtures in good repair.
Oct 30, 2019 14 demerits · 4 violations
Inspector comments: Issued intent to suspend for #5, #17 and#24
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Observed missing weekly records for total alkalinity and daily for main drain checks. Record as required. Intent to suspend issued.
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
.2535 (11) The pool operator shall inspect the pool at least daily and maintain written records.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed ladder missing tread. Repair/replace.
.2521(b) Ladders shall have slip-resistant tread.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed broken tile on pool deck. Repair/replace. Intent to suspend issued
.2537(2) Decks shall be kept in good repair.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed no flow meter on return pipe for pool. Provide flow meter. Intent to suspend issued.
.2518(g) Install flow meter on return line per manufacturer instructions.
Jan 8, 2019 6 demerits · 1 violation
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed throw rope at 50ft. Throw rope must be 27ft. Coreected on site
Nov 14, 2018 18 demerits · 5 violations
Inspector comments: Intent to suspend issued for:
Underwater pool light
Record keeping
Missing return fitting
Doors not self latching
Call Chris Sells when repairs are complete at 704 576 8678.
Permit will be suspended if repairs are not complete within 30 days.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Observed main drain checks missing from new form.
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
Observed one inlet fitting missing near light at shallow end.
.2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed 2 crash bars not properly working leaving door not able to latch.
.2537(b) All gates and doors shall be self-closing, self-latching.
#21 · Premises: pool and deck lighting provided at pools that operate at night −4
Observed one pool light not functioning.
.2524(d) Provide sufficient underwater lighting.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed white chemical powder on floor in chemical storage room.
.2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up.
Jan 25, 2018 2 demerits · 1 violation
Inspector comments: Verified PDSC information.
Observed no non-compliant condition.
#33 · Dressing and sanitary facilities: hose bibbs and floor drains provided −2
Observed no hose bib in bathroom.
Oct 25, 2017 6 demerits · 2 violations
Inspector comments: Intent to suspend issued for pool door motion sensor.
Please contact Christopher Sells when repairs are complete at 704 576 8678, if repairs are not complete in 30 days the permit will be suspended
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed doors with motion sensor for unlatching into patio.
**Doors must be self closing self latching, no motion sensors can be used to unlatch the door.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed no mechanical ventilation in chemical room.
**Maintain mechanical ventilation in chemical store room
Jun 27, 2017 24 demerits · 6 violations
Inspector comments: IMMEDIATE SUSPENSION ISSUED for #1 & #2.
Pool cannot be re-opened without written approval from the Mecklenburg County Health Dept.
Contact L. Boyes @ 704-507-6806.
#1 · Water quality: water clear enough to clearly see bottom of pool and pool drain −6
Pool cloudy. Main drain covers (& bottom of pool) difficult to see.
** Maintain clarity of water so that main drain covers are clearly visible from pool deck at all times.
IMMEDIATE SUSPENSION
#2 · Water quality: disinfectant residual provided by −6
Observed Bromine level at .6ppm. ** Maintain Bromine level at a minimum of 2.0ppm.
IMMEDIATE SUSPENSION
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
One weir will not float & therefore is not functioning as designed. ** Replace weir.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Two of the (double) doors not self-latching properly.
** Repair.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
- No natural cross draft ventilation or forced air ventilation in equipment room. ** Provide.
- Floor wet under circulation system- unable to determine source of water. ** If leak found, repair/ resolve.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
- Hot water at least 124F @ shower & @ lavatories in restrooms. ** Maximum temperature allowed is 110F.
- No soap at lavatory in men's restroom. ** Provide soap.
Nov 29, 2016 18 demerits · 5 violations
Inspector comments: #11 One ladder missing an end cap. ** Installed while EHS on-site.
Immediate Suspension issued for #6.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Only one total alkalinity reading recorded thus far this month. ** Check & record total alkalinity at least 1 time per week.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
VGB information from 2015 PDSC form is no longer up to date. One equalizer line cover has been replaced.
** Submit new PDSC form to K. Wilson (Meck. Co. Health Dept.). Form must be approved.
Immediate Suspension issued.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Both weirs missing. ** Installed while EHS on-site.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Light inoperable in chemical room. ** Resolve.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Hot water at least 127F @ shower (inside pool enclosure) & @ lavatories.
** Maximum temperature allowed is 110F.
Jun 29, 2016 4 demerits · 2 violations
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed one ladder with step not secured at one side.
** corrected while EHS on-site.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Hot water at least 118F @ shower & @ lavatories in restrooms. ** Maximum allowed is 110F.
Water spewing out @ junction of handicap shower head & "hose". ** Resolve.
Nov 18, 2015 8 demerits · 3 violations
Inspector comments: Barrels of acid in equipment room. ** All chemicals should be stored in chemical room.
INTENT TO SUSPEND issued for #5.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Total alkalinity being recorded approximately every 13 days. ** Record weekly. (ITS)
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Floor wet in equipment room due to water dripping from overhead dehumidifier. ** Resolve.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
Hot water at least 130F @ shower & @ lavatories in restrooms. Maximum allowed is 110F.
Feb 2, 2015 20 demerits · 6 violations
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Alkalinity not recorded weekly. Record weekly.
#22 · Premises: emergency telephone provided −6
Centre spelled incorrectly on emergency phone sign. Corrected with temporary coverage of incorrect spelling.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Pump with small leak. Repair.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Light burnt out in chem storage. Replace.
#27 · Equipment room: filter backwash discharged through an air gap −2
Pipe for backwash tilted so air gap no longer provided over pit. Provide air gap.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Water >115 F in restrooms. Maintain at 110 F or below.
Nov 17, 2014 2 demerits · 1 violation
Inspector comments: #12. Missing one inlet fitting. **Install.
GC #28. Lack "Shower Before Entering Pool" sign. **Obtain and post.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Hot water ~122F @ shower and @ lavatories in restrooms. **Maximum temperature of 110F allowed.
Handicap shower has major leak at junction of hose & shower head. **Repair.
Mar 25, 2014 12 demerits · 3 violations
Inspector comments: Intent to Suspend issued for #16.
#3 · Water quality: pool water pH −6
Observed pH @ 7.1. **Maintain pH 7.2 - 7.8. pH raised to 7.2 while on-site.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed 2 double doors of which 1 side of each will not self-latch properly. **correct/repair.
Intent to Suspend issued.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Observed hot water 113.2F at shower in pool area & hot water ~115.8F at lavatories in restrooms outside pool entrance. **Maximum allowed is 110F.
Sep 25, 2013 6 demerits · 2 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Missing 1 (of 2) weirs. Corrected while on-site.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Observed hot water @ 117F at shower in pool area and hot @ 113F at lavatories in restrooms outside pool entrance. **Maximum allowed is 110F.
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “CHARLOTTE HILTON AIRPORT HOTEL” or State ID 2060530117). Inspection type (routine vs. follow-up) is not published in the county's data.