12demerits
BEXLEY CROSSING AT PROVIDENCE
11215 CLUB CREEK LN, Charlotte, NC 28277
Year-Round Swimming Pool · NC permit/State ID 2060530131
Latest result12 demerits
Last inspectedAug 25, 2026
Inspections on record25
On record sinceJul 25, 2013
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Jul 25, 2013Lower is betterAug 25, 2026
Inspections & violations
Aug 25, 2026 12 demerits · 3 violations
Inspector comments: Conducted inspection with CPO. Pool remains on A status and in good standing.
Pool maintains electronic chemical records.
NOTE: CPO EMAIL TOO LONG FOR CDP: BEXLEYPROVIDENCE OR MAINTENANCESUPERVIS @WEINSTEINPROPERTIES.COM
IMPELLER VERIFICATION DONE - MODEL NUMBER ON PUMP DOES MATCH HP - VERIFIED AS P4E6FL FOR BOTH PUMPS
Const. Date: 11/1/2000 Rope Length: 50' Night Swim?: N
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs.
Four out of five weirs missing. Operator replaced. No permit action.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less.
Observed ring buoy throw rope to be over 51 feet when 50 foot exactly is required. Operator shortened to 50ft. No permit action.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
No 3' clear walking space around piping. Vats of chemicals in pump room. Pool built 2000. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
.2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
May 8, 2026 4 demerits · 1 violation
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed excessive debris in skimmers. Keep skimmers free of debris.
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.
Aug 4, 2025 42 demerits · 10 violations
Inspector comments: Immediate suspension issued for water quality. Pool must remain closed with signage posted until suspension is lifted by Health Department. Contact Marie Daley at 704-507-6806 when water quality is in compliance to lift suspension.
Pool must also have trained operator to oversee pool for suspension to be lifted.
Other permit items to verify at time of return visit include records, CPO, pool floor, weirs replaced, 6’ clearance, decking repaired, gates (horizontals and no openings) and doors.
“E” Immediate suspension status
Inspection with Jamie Wright and Chuck Lipes
No night swimming. Pool not heated.
#2 · Water quality: disinfectant residual provided by −6
Chlorine 0 ppm at time of inspection. .2535(4) Maintain chlorine at least 1.0 ppm.
*Immediate suspension item
#3 · Water quality: pool water pH −6
PH 8.1 at time of inspection.
.2535(1) Maintain pH at 7.2 to 7.8.
*Immediate suspension item.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Pool not being checked daily, records missing entries since 6/14 on day of inspection 8/4. Certified pool operator (CPO) no longer on property. Another worker helping onsite. Must provide DAILY maintenance of pool by trained operator.
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
.2535 (11) The pool operator shall inspect the pool at least daily and maintain written records.
.2537(c) Pool owner shall provide for the operation and maintenance of the pool by a trained pool operator.
*Permit item.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Pool floor with debris and buildup of algae.
.2537(14) Keep pool surface clean and pool floor free of debris.
*permit item
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed multiple weirs missing out of a total of 5 skimmers.
.2518(k) Replace missing weirs.
*permit item
Skimmer with debris.
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Operator cleaned and corrected.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
One ladder loose in pool.
.2521 Install ladders per manufacturer instructions.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Rope tangled at time of inspection.
.2530(a) Lifesaving equipment should be conveniently located. Keep accessible. Operator untangled and corrected.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Back gate by pool equipment room has latch installed creating horizontal foothold less than 45” inches height. Plexiglass broken on gate by pump room and near leasing office, allowing more than 1/2” openings within 18” of latching mechanism. Door onto pool deck from clubhouse under renovation not latching.
.2528(a) Maintain 45" between bottom horizontal and next horizontal on fence and/or gate (post-May 2010).
.2528(b) Horizontals shall not be located less than 45" in height.
.2528(a) Gate latches located at less than 54" shall require the use of key, combination lock or card reader or be located on the inside of the gate at least three inches below the top of the gate with no greater than 1/2" within 18" of latch mechanism.
.2537(b) All gates and doors shall be self-closing, self-latching.
*Permit item
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Chairs within 6’ of pool. Decking cracked at ladder by 4 FT and 5 1/2 FT depth.
.2522(a) Provide 6 ft of clear walking space around the pool at all times.
.2537(2) Decks shall be kept in good repair.
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile.
*Permit item
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
No 3' clear walking space around piping. Vats of chemicals in pump room. Pool built 2000. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
.2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
Apr 14, 2025 32 demerits · 9 violations
Inspector comments: 30 day Intent to Suspend (ITS) items include records, pool floor with debris and screw in drain visibility, inlet fittings replaced, weirs replaced, 6 foot clearance and flow meter operational.
Contact Marie Daley at 704-507-6806 when items are corrected to lift ITS
Pool not heated.
No night swimming
“W” Status
Inspections with Gregory Agnew
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Pool not being checked daily, records missing entries since 3/6 on day of inspection 4/14.
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
*Permit item.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed leaves on pool floor, hard to tell one screw in bottom of main drain is not visible, but drain is secure. Ensure screws are in place and installed per manufacturer. Keep pool floor clean.
.2537(14) Keep pool surface and pool floor free of debris.
*Permit item
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed 2 weirs missing out of a total of 5 skimmers.
.2518(k) Replace missing weirs.
*permit item
Skimmer with debris.
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Operator cleaned and corrected.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Body hook fallen behind bushes.
.2530(a) Lifesaving equipment should be conveniently located.Operator moved and corrected. Advised cutting bushes for accessibility or moving emergency equipment before accessibility worsens.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Chairs within 6’ of pool.
.2522(a) Provide 6 ft of clear walking space around the pool at all times.
*Permit item
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter not working at time of inspection. .2518(g) Keep flow meter operational.
*permit item
Inlet fittings missing.
.2518(i) Arrange inlets to produce uniform circulation.
*Permit item
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
No 3' clear walking space around piping. Lock unlocked at time of inspection. Vats of chemicals in pump room. Water under pump. Pool built 2000. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
.2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
.2533(d) Pump room floor shall be kept dry and free of standing water.
.2533(a) The equipment room door shall have a permanent lock and be kept locked when not in use by the pool operator.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
Shower off at time of inspection. .2526(h) Shower(s) shall be provided.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Women’s paper towel dispenser not working.
.2526(m) Keep restrooms and fixtures clean and in good repair.
Oct 9, 2024 18 demerits · 4 violations
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
.2535 (11) The pool operator shall inspect the pool at least daily and maintain written records.
Observed gaps in the record book where some data is missing. Keep proper daily and weekly records.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. Observed 2 weirs missing out of a total of 5 skimmers. Replace the missing weirs.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed ring buoy throw rope to be 47 feet 7 inches when 50 foot exactly is required. New rope was provided and made to be 50 foot. Ensure ring buoy stays in good repair.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed chairs to be 3 feet from water edge. Items were moved back to be 6 ft. From the edge.
Feb 8, 2024 12 demerits · 3 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed leaves on pool floor.
Observed waterline tiles collecting residue.
.2537(14) Keep pool surface and pool floor free of debris.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed leaves collecting in skimmers.
.2518(k) Water level shall be maintained to assure skimmers are operable.
#23 · Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 −4
Observed chlorinator not functioning. Corrected during inspection.
Leaves removed from pump baskets.
.2535(6) Automatic chlorine and bromine feeder pumps shall be automatically prevented from operating when the circulation pump is not in operation.
Aug 16, 2023 22 demerits · 6 violations
Inspector comments: Immediate Suspension and Issued for water quality. Pool must remain closed with signage posted until in compliance and suspension lifted by Health Deopt. Contact Marie Daley at 704-507-6806 went in compliance to lift suspension. Other items to check out return visit include recordkeeping and certified Poole operator.
Main drains expire Otober 2023 replace and submit updated PDSC form to Health Dept for approval prior to expiration to avoid permit action.
E Immediate suspension
#2 · Water quality: disinfectant residual provided by −6
Chlorine 0.2 ppm at time of inspection. .2535(4) Maintain chlorine at least 1.0 ppm.
*Immediate suspension item,
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Main drains not being checked daily, records missing some entries and no weekly tests.
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. No CPO on file.
*Permit item. Will verify records on return visit
.2537(c) Pool owner shall provide for the operation and maintenance of the pool by a trained pool operator.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Debris in skimmers at time of inspection. Operator cleaned and corrected.
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Some chairs and pool furniture within 6' of pool at time of inspection. .2522(a) Provide 6 ft of clear walking space around the pool at all times. Operator moved and corrected.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
No 3' clear walking space around piping. Vats of chemicals in pump room. Pool built 2000. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
.2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Men’s restroom urinal out of order and toilet soiled at time of inspection.
.2526(m) Keep restrooms and fixtures clean and in good repair.
Mar 13, 2023 18 demerits · 5 violations
Inspector comments: 30 Day Intent to Suspend (ITS) for records. Updated CPO to Quinton Ames.
“W” status.
No Night Swimming.
Main drains expire October 2023. Skimmer equalizer covers expire March 2024. Update and submit updated PDSC form prior to expiration to avoid permit action.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Main drains not being checked daily, records missing some entries and no weekly tests.
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
*Permit item. Will verify records on return visit
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Debris in skimmers at time of inspection. Operator cleaned and corrected.
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Some chairs and pool furniture within 6' of pool at time of inspection. .2522(a) Provide 6 ft of clear walking space around the pool at all times. Operator moved and corrected.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter not working at time of inspection. .2518(g) Keep flow meter operational.
Operator adjusted and corrected.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
No 3' clear walking space around piping. Vats of chemicals in pump room. Pool built 2000. Pump room unlocked at time of inspection. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
.2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
Aug 23, 2022 12 demerits · 4 violations
Inspector comments: Water quality in compliance and pool appears clean. Lifted suspension. Updated CPO to Jeremia Conradie
Changed to “A” Open for Business.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed 1 weir missing. .2518(k) Replace missing weirs. Operator replaced weir and emptied baskets. Corrected.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Some chairs and pool furniture within 6' of pool at time of inspection. .2522(a) Provide 6 ft of clear walking space around the pool at all times. Operator moved and corrected.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
No 3' clear walking space around piping. Vats of chemicals in pump room. Dry bags of chemicals on floor in chemical room.Some dry chemicals stored over large liquid vats in chemical room. Pool built 2000. Pump room unlocked at time of inspection. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
.2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
.2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up.
.2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor.
.2533(a) The equipment room door shall have a permanent lock and be kept locked when not in use by the pool operator.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Women's restroom soap dispenser broken off wall, not able to use at time of inspection. Extra soap provided.
.2526(m) Keep restrooms and fixtures clean and in good repair.
May 31, 2022 8 demerits · 3 violations
Inspector comments: Lifted suspension for expired Intent to Suspend items (spare pump basket and records) and conducted pre-permit inspection.
Issued local permit sticker. No Night Swimming.
Electrical permit (E4203387) issued for motor change out, finalized 5/2022.
CPO updated to Mathew Timeus, certification number NC18221626.
Note: Two pumps, tied to one system, one placard does not match impeller verification.
‘
Main drains expire October 2023. Replace and submit updated PDSC for approval prior to expiration to avoid permit action. Skimmer equalizer covers expires March 2024
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Gates with push bar, less than 54" in height have openings in mesh greater than 1/2". One side gate at time of visit. .2528(a) Gate latches located at less than 54" shall require the use of key, combination lock or card reader or be located on the inside of the gate at least three inches below the top of the gate with no greater than 1/2" within 18" of latch mechanism.
.2537(b) All gates and doors shall be self-closing, self-latching. Operator placed plastic piece on fence to cover openings and adjusted gate to self-close, self-latch. Corrected.
Fencing with horizontals less than 45" in some areas. Pool built 2000.
.2528(a) Maintain 45" between bottom horizontal and next horizontal on fence and/or gate (post-May 2010).
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
No 3' clear walking space around piping. Vats of chemicals in pump room. Pool built 2000. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
.2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
No paper towels in men’s restroom. Provide for hand drying.
Could not tell if mirrors are shatterproof. .2526(k) Provide shatterproof mirrors or backing.
Oct 28, 2021 20 demerits · 6 violations
Inspector comments: 30 Day Intent to Suspend (ITS) issued for records, weirs, offsets greater than 1/2" and spare pump basket (Sta-Rite P4E6FL) Contact Marie Daley at 704-507-6806 when in compliance to lift ITS.
Changed to "W" status
General comments: Automatic feeder reading 8.15, water at 7.8, advised reaching out to company for calibration of feeder
Emergency phone for 911 displays "Apartment R" at 911, rather than "Pool". Advised contacting Kings III or phone company to correct specific location identifier. Address is correct.
Operator updated to Shelton Ward, verified certification
2 pumps - same model tied together, impeller verified 4/19 - differs from placard
Inspection with Walter Russell
No signature due to COVID
No Night Swimming
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Main drains not being checked correctly daily (operator thought drains indicated being backwashed). Educated operator on record keeping.
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
*Permit item. Will verify records on return visit
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Debris in skimmers at time of inspection. Operator cleaned and corrected.
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.
2 weirs missing. .2518(k) Replace missing weirs.
*Permit item
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Ladder loose, not secure, deck starting to crack by ladder rail entry into deck at time of inspection.
.2521 Install ladders per manufacturer instructions.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Some chairs and pool furniture within 6' of pool at time of inspection. .2522(a) Provide 6 ft of clear walking space around the pool at all times. Operator moved and corrected.
Deck cracking in 3 locations (two in coping, one crack by ladder).
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile.
*Permit item
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Operator unable to locate spare pump basket at time of inspection. .2518(e) Provide a spare basket for pump.
*Permit item
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
No 3' clear walking space around piping. Dry chemicals stored on over vats of chemicals in chemical room. No backflow prevention on hose bibs. Lighting out in chemical storage. Water on floor in pump room. Pool built 2000. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. .2534(4) Provide storage for pool chemicals in waterproof containers, to prevent reaction or store up off the floor. .2533(g) Provide a hose bib with backflow prevention device within 50 ft. of the equipment room. .2533(b) Provide sufficient lighting in pump and chemical room.
.2533(d) Pump room floor shall be kept dry and free of standing water.
Apr 8, 2021 32 demerits · 9 violations
Inspector comments: Immediate suspension issued for water quality. Contact Marie Daley at 704-507-6806 when in compliance to lift suspension. Posted "Pool Closed" signs
Intent to Suspend (ITS) items: records, gates self-closing, self-latching, openings greater than 1/2" within 18" of latching mechanism and flow meter.
Changed to "E" Immediate Suspension status.
Pool not heated. No Night Swimming. Pool must close at dusk unless visit is scheduled before dawn or after dusk to verify sufficient lighting.
Inspection with Shawn Stacey and Odell Peoples
No signature due to COVID
#3 · Water quality: pool water pH −6
pH 6.8 at time of inspection. .2535(1) Maintain pH at 7.2 to 7.8.
**Immediate suspension issued for this item. Pool MUST REMAIN CLOSED until suspension is lifted by Health Dept. Contact Marie Daley at 704-507-6806 when in compliance to lift suspension.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Records not being maintained daily at time of inspection. No weekly alkalinity and cyanuric checks or pool maintenance. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
*permit item
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Debris in skimmers at time of inspection. 1 weir missing. .2518(k) Replace missing weirs.
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Operator replaced weir and emptied baskets. Corrected.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Ladder loose and missing rubber stoppers at time of inspection.
.2521 Install ladders per manufacturer instructions.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Gates with push bar, less than 54" have openings in mesh greater than 1/2". One side gate not latching every time at time of visit. .2528(a) Gate latches located at less than 54" shall require the use of key, combination lock or card reader or be located on the inside of the gate at least three inches below the top of the gate with no greater than 1/2" within 18" of latch mechanism.
.2537(b) All gates and doors shall be self-closing, self-latching. *Permit items
Fencing with horizontals less than 45" in some areas. Pool built 2000.
.2528(a) Maintain 45" between bottom horizontal and next horizontal on fence and/or gate (post-May 2010).
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Some chairs and pool furniture within 6' of pool at time of inspection. .2522(a) Provide 6 ft of clear walking space around the pool at all times. Operator moved and corrected.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter not working at time of inspection. .2518(g) Keep flow meter operational.
*permit item
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
No 3' clear walking space around piping. Dry chemicals stored on floor and in pump room. No backflow prevention on hose bib. Lighting out in chemical storage and pump room. Water on floor in pump room. Pool built 2000. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. .2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor. .2533(g) Provide a hose bib with backflow prevention device within 50 ft. of the equipment room.
.2533(b) Provide sufficient lighting in pump and chemical room.
.2533(d) Pump room floor shall be kept dry and free of standing water.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Men's restroom soap dispenser broken off wall, not able to use at time of inspection..2526(j) Provide soap and soap dispenser, no glass, at each sink.
.2526(m) Keep restrooms and fixtures clean and in good repair.
Sep 2, 2020 20 demerits · 6 violations
Inspector comments: Intent to Suspend (ITS) for weirs and gates self-closing, self-latching.
PDSC form on file indicates Sta-rite P4E6FL 1.5 HP. Both motors have been replaced with 2 HP motors. One pump missing tag and other indicates P4E6G-189L (a 2HP pump). Documentation from 4/16/19 has impellar verification, that does not match tag. If pump has been changed submit updated PDSC.
Ensure proper electrical permits have been pulled.
No signature due to COVID-19.
Inspection with: Shawn Stacey
Report to: shawnstacey42@gmail.com
Restrooms were remodeled and mirrors have not been documented as shatterproof. Provide shatterproof mirrors in restrooms for
pool.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Weir missing at time of inspection.
.2518(k) Replace missing weirs.
*30 Day ITS item.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Ladder loose and missing rubber stoppers at time of inspection.
.2521 Install ladders per manufacturer instructions.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed buoy rope cut by landscaping, not in good repair and 57'.
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Operator replaced with new 50' rope. Corrected.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Pedestrian gate (with sidewalk) not self-closing, self-latching at time of inspection and open. This gate remains locked, but classifies as a pedestrian gate, rather than service gate.
.2537(b) All gates and doors shall be self-closing, self-latching.
*30 Day Intent to Suspend (ITS) item. Contact Marie Daley at 704-507-6806 when in compliance to lift ITS.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Not 3' clear walking space around piping. Dry chemicals stored on floor and in pump room. No backflow prevention on hose bib. Pool built 2000. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. .2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor.
*Spare pump basket from old spa can be used.
.2533(g) Provide a hose bib with backflow prevention device within 50 ft. of the equipment room.
.2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
Shower off at time of inspection. .2526(h) Shower(s) shall be provided.
Mar 18, 2020 12 demerits · 4 violations
Inspector comments: Night Swimming not permitted without onsite visit made before dawn or after dusk to verify sufficient lighting. Contact Marie Daley at 704-507-6806 to schedule, if desired.
Restrooms were remodeled and mirrors have not been documented as shatterproof. Provide shatterproof mirrors in restrooms for pool.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Ladder missing rubber stoppers.
.2521 Install ladders per manufacturer instructions.
#22 · Premises: emergency telephone provided −6
Callback number did not match signage for emergency phone at time of inspection.
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone.
Operator posted signage with correct number. Corrected.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Pump room observed with water on floor. Not 3' clear walking space around piping. Chemicals stored on floor and dry chemicals below liquid vats. Pool built 2000. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
.2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor.
.2533(d) Pump room floor shall be kept dry and free of standing water.
*Spare pump basket from old spa can be used.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
Provide backflow prevention device on hose bibb on pool deck and in chemical storage room.
Jul 31, 2019 6 demerits · 2 violations
Inspector comments: OBSERVED THAT THE PUMPS HAVE NO STICKER OR ARE LABELED AS A"P4E6G" MODEL. ON FILE PDSC FORM CONTAINS APPROVED NOTES AND GPM MEASUREMENTS INDICATING THAT IMPELLER IS P4E6FL MODEL FOR BOTH PUMPS.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Observed records being kept, but there were not entries for the weekends in July. The pool records and checks must be kept for every day the pool is open to swimming including weekends and holidays. -I.T.S. issued. Expires 8/31/2019.
POOL WILL BE CLOSED TO SWIMMING IF RECORD KEEPING IS NOT DONE CORRECTLY.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed ladder feet to be missing the rubber bumpers. Replace the rubber bumpers.
Apr 22, 2019 10 demerits · 2 violations
Inspector comments: CPO indicated that pool is not available for swimming after sundown or before sunrise. Ensure signs establish that the pool is not available for swimming from dusk to dawn. Permitting for night swimming will require an on-site evaluation be the Health Department to ensure proper lighting levels. Contact C. Elmore if this evaluation is desired.
The I.T.S. has a 30 day deadline, expiring on May 22nd 2019. Be aware that new pool permits will not be issued for pools on "E" or "W" status when their current permit expires on April 30th 2019. This pool is currently on "W" status.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed ring buoy throw rope to be 48 feet long. Rope required to be 50 feet long for this pool. Rope was corrected to 50 feet long. -C.D.I.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed 1 gate not self-latching, although it is self-closing. Observed one gate chained, function of this gate could not be determined. Gates must fully self-close and fully self-latch. Observed magnetic closure on the outside of one gate to be a foothold on the gate lower than 45 inches from the ground. Correct the magnetic closure by removing it, raising it so that the top surface is 45 inches or more from the ground, or placing a surface angled 45 degrees over the top of it to prevent it from presenting a flat purchase to be climbed on. I.T.S. issued for the gate not self latching and the magnetic closure providing a foothold.
May 24, 2018 14 demerits · 5 violations
Inspector comments: Permit issued.
No Night Swimming.
Items from suspension have been corrected (contrasting color bands).
**Note: Plaster color is darker than required (less than 50% black, between value of 2 and 3 on grey scale and not in compliance). .2514c. Per Tim Dutcher, if any work is done pool must meet compliance with rules. .2514c, code requirement for construction.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
One ladder missing rubber stop. Keep in good repair.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Maintenance gate not self-closing at time of inspection. Ensure gates self-close, self-latch. Operator tightened and corrected to self-close, self-latch.
Gate entrance on left side of clubhouse had magnet latch installed less than 30", protruding out greater than 1", creating foothold. Eliminate handhold/foothold on gate puilt prior to 2010 (30"-45"). Operator installed slanted metal piece to eliminate horizontal foothold. Magnet latch has battery backup. Corrected.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Provide spare pump basket. Spare pump basket from spa pump, same type, from filled in spa can be used. Corrected.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
Provide soap in men's restroom.
Hot water over 110 degrees F in restrooms. Maintain hot water at 110 degrees F and below.
#33 · Dressing and sanitary facilities: hose bibbs and floor drains provided −2
Provide vacuum breaker for hose bibb on pool deck.
Nov 13, 2017 10 demerits · 3 violations
Inspector comments: Motor 3 HP, Records indicate pump as 2 Sta-Rite P4E6G-185L, 2 HP. Advised to ensure motor is correct for pump.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Skimmer baskets with debris and leaves. Keep clean. Operator cleaned. Corrected.
2 of 5 weirs missing. Replace with functional weirs.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Loose handrail at entrance. Keep tightened. Ladder missing rubber stopper. Replace and keep in good repair.
#13 · Pool maintenance: contrasting band on steps and benches −4
Left side step at handrail missing contrasting bands and in step in disrepair. Ensure contrasting color bands are visible and no more than 1" from the edge of the tread and keep in good repair.
**Issued 30 Day Intent to Suspend for this item. Contact Marie Daley at 70-507-6806 when corrected.
Feb 20, 2017 4 demerits · 1 violation
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed minor amount of debris in skimmers. Keep skimmers free of debris. Also observed 1 of 5 weirs missing. Replace missing weir.
Dec 7, 2016 18 demerits · 4 violations
Inspector comments: Issued immediate suspension for #22.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed minor debris on pool floor. Keep pool floor free of debris.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed gate near pump room not self closing self latching. Correct so that gate is self closing and self latching or locked.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed deck chairs within 6 feet of pools edge. Maintain 6 feet of clearance at all points.
#22 · Premises: emergency telephone provided −6
Observed emergency phone inoperable. Repair.
Mar 2, 2016 18 demerits · 5 violations
Inspector comments: Pump system information does not match what is provided on PDSC form. Please re submit accurate PDSC sheet for approval. Permit is suspended until accurate PDSC is recieved and approved.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Observed written records missing for the past few weeks. Maintain written records on a daily basis.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed excessive debris in skimmers. Keep skimmers free of debris.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed end cap missing on ladder. Replace.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed deck chairs within 6 feet of pools edge. Maintain 6 feet of deck clearance at all points.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Pump information that was submitted on PDSC form to the MCHD is innaccurate. Please re-submit form with accurate information.
Oct 20, 2015 14 demerits · 3 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed debris and leaves in skimmers. Keep skimmers free of debris.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed body hook pole collapsible. Body hook pole must be 1 solid piece at least 12 feet in length. Immediate suspension issued.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed deck chairs within 5 ft of pools edge. Maintain 5 feet of deck clearance at all points.
May 21, 2015 32 demerits · 9 violations
Inspector comments: Post copy of pool permit in pool area. Permit not observed.Immediate suspension issued.15)Contact Will Harrison 704-336-5528 when issues have been corrected for reinspection.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
Pool recently replastered. Installed inlet fittings on vacuum ports. Ports must be plugged when not in use. Corrected by operator.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
One ladder missing endcaps. Maintain in good condition.
#13 · Pool maintenance: contrasting band on steps and benches −4
Pool recently replastered a dark blue. Black tile is no longer contrasting. Provide 2" wide contrasting tile or color band at edge of steps.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Ring buoy is not an approved US Coast Guard approved buoy. Provide US Coast Guard approved ring buoy.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Make doors to clubhouse self-closing and self-latching.
#21 · Premises: pool and deck lighting provided at pools that operate at night −4
Pool has no night swimming. Provide signage stating pool hours of operation.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Dry chemicals stored on the ground in storage room. Store in buckets or off of the ground. Corrected.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Mirrors hanging loosely on the wall in the restroom. Provide documentation that mirrors are shatterproof.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
Provide backflow preventor for hosebib at emergency phone.
Jun 4, 2014 18 demerits · details not yet loaded
Violation details for this inspection are not yet loaded on this site. We're still importing older records — check the official county portal for the full report.
Jul 25, 2013 4 demerits · details not yet loaded
Violation details for this inspection are not yet loaded on this site. We're still importing older records — check the official county portal for the full report.
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “BEXLEY CROSSING AT PROVIDENCE” or State ID 2060530131). Inspection type (routine vs. follow-up) is not published in the county's data.