HAMPTON INN

530 E MARTIN LUTHER KING JR BLVD, Charlotte, NC 28202
Year-Round Swimming Pool · NC permit/State ID 2060530136
Latest result18 demerits
Last inspectedFeb 26, 2026
Inspections on record26
On record sinceNov 25, 2013

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

01530 Nov 25, 2013: 4Jun 3, 2014: 8Nov 13, 2014: 10Feb 5, 2015: 8Sep 21, 2015: 12Jun 1, 2016: 10Nov 21, 2016: 12Feb 9, 2017: 10Sep 11, 2017: 12Feb 27, 2018: 12Nov 5, 2018: 16Feb 4, 2019: 10Oct 31, 2019: 14Feb 24, 2020: 0Nov 24, 2020: 14Feb 2, 2021: 14Oct 7, 2021: 20Jan 13, 2022: 14Oct 18, 2022: 14Jun 1, 2023: 0Oct 5, 2023: 30Jan 30, 2024: 14Nov 26, 2024: 12Feb 12, 2025: 0Sep 25, 2025: 26Feb 26, 2026: 18
Nov 25, 2013Lower is betterFeb 26, 2026

Inspections & violations

Feb 26, 2026 18 demerits · 5 violations
Inspector comments: Inspection completed with Husani Parris present. Intent to suspend permit issued for following items: 1. Missing threaded vacuum port cap. 2. Door leading to pool deck has excessive delay on latch activation mechanism. Correct these items within 30 days or the permit may be suspended. Note- drain covers and equalizer line coverings expire 10/18/26. Ensure these are replaced with a new pool drain suction compliance form (PDSC) submitted and approved by the health department prior to expiration date or permit may be suspended.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
.2539(b) All suction fittings shall be installed in accordance with the manufacturer's instructions. Observed no threaded suction line fitting in place on suction line. Observed what appeared to be a laddder end cap inside suction line. Suction line was on during inspection. CDI- suction line disabled.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed missing ladder end cap.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
.2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. Observed improper suction line fitting. Intent to suspend permit issued. Correct within 30 days with threaded cover.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing, self-latching. Observed door that leads into pool area on excessive delay for activated latching mechanism. Correct within 30 days. Intent to suspend permit issued.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(d) Pump room floor shall be kept dry and free of standing water. Observed water on floor of pump room. Observed leak at pump near pump basket housing.

View this inspection on the county portal ›

Sep 25, 2025 26 demerits · 6 violations
Inspector comments: Pool is closed by order of the Health Department. Contact C. Elmore when the closure issues are corrected. The pool cannot reopen without a verification visit by the Health Department. Contact C. Elmore when the items are corrected to schedule the follow-up. 704-507-6814 This pool only requires one ring buoy and throw rope. You can have more than are required, but all that are in the pool area must meet the requirements and the rope length for this pool. Throw rope length is 24 feet for this pool. Observed the flow meter to be sticking. Ensure proper operation of the flow meter. Observed weir to be installed backwards in the skimmer, the float foam portion of the weir is supposed to face away from the pool. This should be corrected to ensure proper skimmer operation. Observed motor/pump assembly to have shifted off of the mount and it appears that it is resting on the floor of the pump room. Correct this so that the motor and pump assembly are not in contact with the wet floor. Ensure that a CPO attends the pool every day that the pool is open and that the logs are properly kept everyday the pool is open. Main drain covers and equalizer line covers at this pool will expire 10/18/2026.
#2 · Water quality: disinfectant residual provided by −6
.2535(4) Maintain chlorine at least 1.0 ppm. Observed chlorine to be at 0.2 PPM. This is 20% of the required minimum for safe operation of the pool. Correct the chlorine. Chlorine for operating the pool must be added to the pool by way of the chlorination system. Do not hand feed or add disinfectant directly to the pool for operation. This can only be done for maintenance or shocking when the pool is closed.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. .2535 (4) Lower and maintain cyanuric acid at or below 100 ppm. .2535 (11) The pool operator shall inspect the pool at least daily and maintain written records. .2537(c) Pool owner shall provide for the operation and maintenance of the pool by a trained pool operator. Observed no record in the log for 9/19/2025, 9/23/2025, 9/24/205. As there are no records for the last 2 days it is unclear when the chlorine in the pool dropped below safe levels. Keep proper records with the proper recording of who takes the readings. Ensure a CPO is available every day to attend the pool. No Permit Action taken for this violation at this time.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
.2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. Observed floor return cover to have been secured with screws that have corroded. They are now protruding from the faceplate to the floor return cover where they present a hazard where a bather could injury their foot from coming into contact with the rusty screws. Correct this hazard and always use non-corrosive hardware for applications inside the pool.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing, self-latching. Observed outer entry door and access door next to the emergency phone not properly self-closing and self-latching. Correct the doors.
#22 · Premises: emergency telephone provided −6
.2530(f) Emergency phone shall remain operable. Phone not operable. Phone shall connect to 911. 911 shall have correct address and phone number and phone shall audibly ring back.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(d) Pump room floor shall be kept dry and free of standing water. Observed water in the pump room to the extent that it could impact the pump and motor. Correct the wet conditions of the pump room.

View this inspection on the county portal ›

Feb 12, 2025 0 demerits · 0 violations
Inspector comments: No violations noted. This pool only requires one ring buoy and throw rope. You can have more than are required, but all that are in the pool area must meet the requirements and the rope length for this pool. Throw rope length is 24 feet for this pool. Ensure that a CPO attends the pool every day that the pool is open and that the logs are properly kept everyday the pool is open. Main drain covers and equalizer line covers at this pool will expire 10/18/2026.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Nov 26, 2024 12 demerits · 3 violations
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
.2523(c) Depth markers shall include the word "feet" or symbol "ft". Observed 1 depth markers to be missing the “FT“ mark. It was added during the inspection.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept in good repair. Observed some areas of deck where coating is peeling up. Correct these areas by re-coating with proper slip-resistant coating. Intent to Suspend Issued-Deadline is 12/26/2024. Failure to complete corrections prior to the deadline may result in the closure of the pool.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Observed flow meter stuck. Observed leak at the filter. Correct the filter to fix the leak. If the filter requires replacement, replace it with a proper filter appropriate to the flow of the system. This will require approval and in-field plan review for the system. Contact C. Elmore at 704-507-6814 if the filter must be replaced. Intent to Suspend Issued-Deadline is 12/26/2024. Failure to complete corrections prior to the deadline may result in the closure of the pool.

View this inspection on the county portal ›

Jan 30, 2024 14 demerits · 3 violations
Inspector comments: OBSERVED CHLORINE PUCK IN SKIMMER BASKET. THIS IS NOT ALLOWED UNDER NORMAL POOL OPERATION AS IT IS AN IMMINENT HAZARD. REMOVE ANY SUCH PUCKS AND DO NOT USE THEM FOR CHLORINATION UNDER NORMAL OPERATION. PUMP MOTOR HAS BEEN SWAPPED OUT AND MUST PASS AN ELECTRICAL INSPECTION. NEW PUMP IS A 2HP PUMP CONNECTED TO A 1/2 HP PUMP (CHII-N1-1/2F). PUMP DID NOT HAVE GROUND WIRE CONNECTED. THIS IS AN IMMINENT HAZARD DUE TO POTENTIAL ELECTRICAL HAZARD. INTERIOR OF THE POOL COULD NOT BE EVALUATED AS IT WAS TOO CLOUDY TO VIEW. INTERIOR WILL BE CHECKED DURING VERIFICATION VISIT. POOL IS CLOSED BY ORDER OF THE HEALTH DEPARTMENT. CONTACT. C. ELMORE WHEN CLOSURE ITEMS ARE CORRECTED. 704-507-6814. CORRECTIONS MUST BE VERIFIED BY THE HEALTH DEPARTMENT BEFORE POOL CAN REOPEN.
#1 · Water quality: water clear enough to clearly see bottom of pool and pool drain −6
.2535(2) Main drains must be clearly visible from the pool deck. Observed pool too cloudy for safe operation. I.S. Issued. Pool closed to swimming by order of the Health Department.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
.2523(c) Depth markers shall include the word "feet" or symbol "ft". Observed 1 depth marker not to have the “Ft” on it. Correct this depth marker. “Ft” can just be added to the marker at the rear of the number so that it matches the others.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Observed flow meter stuck. Fix flow meter.

View this inspection on the county portal ›

Oct 5, 2023 30 demerits · 6 violations
Inspector comments: POOL IS CLOSED BY ORDER OF THE HEALTH DEPARTMENT. CORRECT THE ITEMS AND CONTACT C. ELMORE TO REQUEST VERIFICATION OF THE CORRECTIONS. POOL CANNOT REOPEN PRIOR TO ON-SITE VERIFICATION BY THE HEALTH DEPARTMENT. C. ELMORE 704-507-6814
#2 · Water quality: disinfectant residual provided by −6
.2535(4) Maintain chlorine at least 1.0 ppm. G.S. 130A-2(3) Chlorine added directly to swimming pool. Chlorination must occur through chlorinator. Eliminate direct hazard to public. Observed chlorine to be 0.0ppm in the pool. Immediate Suspension issued. (I.S.)
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Observed pH to be above 8.0. I.S. Issued.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. .2535 (4) Lower and maintain cyanuric acid at or below 100 ppm. .2535 (11) The pool operator shall inspect the pool at least daily and maintain written records. .2537(c) Pool owner shall provide for the operation and maintenance of the pool by a trained pool operator. Observed no record in the log for 10/4/2023. Keep proper records with the proper recording of who takes the readings. Ensure a CPO is available every day to attend the pool. No Permit Action taken for this violation at this time.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
.2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. Observed pool floor return to be damaged and presenting a hazard to people in the pool. Repair the floor return cover plate and eliminate the hazard. I.S. Issued.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(b) Provide at least 5 ft of clear walking space around the pool at all times. Observed chairs and table closer than 5 foot to the pool. C.D.I. Items were moved.
#22 · Premises: emergency telephone provided −6
.2530(f) Emergency phone shall remain operable. Phone not operable. Phone shall connect to 911. 911 shall have correct address and phone number and phone shall audibly ring back. Immediate Suspension issued.

View this inspection on the county portal ›

Jun 1, 2023 0 demerits · 0 violations
Inspector comments: NO NEW VIOLATIONS NOTED. ALL PREVIOUS VIOLATION ITEMS CORRECTED. POOL HAS PASSED INSPECTION AND BEEN ISSUED THE PERMIT DECAL. PAPER PERMIT WILL BE AVAILABLE ON-LINE AT THE HEALTH DEPARTMENT WEBSITE. DISPLAY THE PERMIT AND DECAL AT THE POOL DECK AREA.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Oct 18, 2022 14 demerits · 5 violations
Inspector comments: New CPO for property. Provide CPO card showing expiration date within 1 week, by 10/25.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Some minor chipping on deck. Monitor and repair if worsens or becomes a safety hazard.
#23 · Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 −4
No flow meter on chlorinator. Original construction. If ever replaced, ensure flow meter installed per NSF requirement.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Fan in chemical storage room not operating. Repair fan per code requirements. Provide forced draw as required.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Hot water in restrooms >116 F. Maintain at 110 F or below. Loose toilet seat in the men's restroom. Keep fixtures in good repair.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
Check valve for fill line ASSE 1015. Required ASSE 1013. Original construction. If ever replaced, replace with approved check valve.

View this inspection on the county portal ›

Jan 13, 2022 14 demerits · 5 violations
Inspector comments: Lynn Sizemore present during the inspection. No signature due to covid restrictions. Pool heater down at time of inspection.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Water backed up on pool floor near emergency phone when spa jets are run. Water eventually drains and does not appear to be causing slip hazard. Continue to monitor to ensure decking is kept free of standing water.
#23 · Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 −4
No flow meter on chlorinator. Original construction. If ever replaced, ensure flow meter installed per NSF requirement.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Leak at hose bib. Flooring around chlorinator wet. Keep pump room floor dry.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Some trash on floor in women's restroom. Keep clean. Water in restrooms >120 F. Maintain at 110 F or below. Mirror at entry into pool area. Does not appear to be shatterproof. Mirrors in restrooms do not appear to be shatterproof. All mirrors shall be shatterproof.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
Check valve for fill line ASSE 1015. Required ASSE 1013. Original construction. If ever replaced, replace with approved check valve.

View this inspection on the county portal ›

Oct 7, 2021 20 demerits · 6 violations
Inspector comments: 6 - Drain covers and equalizer lines expire on 10/20/2021. Due for replacement prior to expiration date. Once replaced, submit updated PDSC form for approval. Immediate Suspension issued for emergency phone. Phone not operable. Once corrected, contact Katie Rudisill at 704-309-5494 to schedule a return inspection.
#22 · Premises: emergency telephone provided −6
Phone not operable. Phone shall connect to 911. 911 shall have correct address and phone number and phone shall audibly ring back. Immediate Suspension issued.
#23 · Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 −4
No flow meter on chlorinator. Original construction. If replaced, install flow meter per NSF approval.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Small leak at pump. Could not verify location; however appears to be a gasket/seal. Repair leak. Flow meter stuck. Keep operational.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Pump room floor wet due to leak at pump. Keep dry.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Hot water in restrooms >120 F. Maintain at 110 or below.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
Check valve for fill line ASSE1015. Original construction. If ever replaced, replace per .2512 or with ASSE 1013 check valve.

View this inspection on the county portal ›

Feb 2, 2021 14 demerits · 4 violations
Inspector comments: Immediate Suspension issued for chlorine. Once corrected, contact Katie at 704-309-5494 to schedule a return inspection.
#2 · Water quality: disinfectant residual provided by −6
Chlorine at 0.8 ppm. Chlorinator was turned up during inspection; however, no change in chlorine. Chlorine shall be at least 1.0 ppm. Do not hand feed. Chlorine shall be introduced to the pool through the chlorinator. Immediate Suspension issued.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
Depth marker on pool deck near handicap lift beginning to peal back. Secure to floor. 3 1/2 ft. Repair prior to return visit or ITS will be issued.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Water in restrooms >125 F. Maintain at 110 F or below.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
Check valve for fill line ASSE1015. If ever replaced, replace with ASSE1013. .2512(b) Water introduced into the pool, either directly or by the circulation system, shall be supplied through an air gap, anti-siphon vacuum breaker, or backflow preventer.

View this inspection on the county portal ›

Nov 24, 2020 14 demerits · 5 violations
Inspector comments: Note - Main drains and equalizer line covers expire in October 2021. New covers shall be installed along with PDSC form once work has been completed. If not received prior to expiration, the permit will be suspended. Intent to Suspend issued for leak in pump room (could not verify if leak was from pool or spa filtration pump) and damage to deck drain. Lynn Sizemore present during the inspection. No signature due to covid restrictions.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Floor wet due to drainage back-up when spa jets are run. Issued ITS on spa permit. .2522(f) Deck shall be sloped to drain. Deck drain damaged near spa. Repair damaged deck drain. Intent to Suspend issued. .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Appears that both pool and spa pumps may be leaking - definite leak on one. Per operator a new motor has been ordered. Ensure electrical permit has been pulled and finaled prior to re-opening the pool/spa once work has been completed. Intent to Suspend issued. Repair leaks.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Water on pump room floor due to leak. Keep dry.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Water in restrooms and at pool shower at 121 F. Maintain at 110 F or below.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
Check valve for fill line ASSE1015. If ever replaced, replace with ASSE1013. .2512(b) Water introduced into the pool, either directly or by the circulation system, shall be supplied through an air gap, anti-siphon vacuum breaker, or backflow preventer.

View this inspection on the county portal ›

Feb 24, 2020 0 demerits · 0 violations
Inspector comments: Verified PDSC information. Observed no non-compliant conditions.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Oct 31, 2019 14 demerits · 5 violations
Inspector comments: Intent to Suspend issued for record keeping and CYA levels. Will verify spa at same time of pool.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Operator was not aware that stabilizer was used in pool and was not recording cyanuric acid. Only one day kept and at least 100 ppm. Lower to below 100 ppm and maintain record keeping for CYA at least weekly. Intent to Suspend issued.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Painted deck beginning to chip near emergency phone. Continue to monitor and repair as needed.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Standing water on pump room floor. Keep free of standing water. Flooring shall be sloped to drain.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Hot water in restrooms >110 F. Maintain at 110 F or below.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
Check valve for fill line for pool rated ASSE 1015. Does not meet rule requirement. If ever replaced, replace with approved check valve. .2512(b) Water introduced into the pool, either directly or by the circulation system, shall be supplied through an air gap, anti-siphon vacuum breaker, or backflow preventer.

View this inspection on the county portal ›

Feb 4, 2019 10 demerits · 3 violations
Inspector comments: #9) Observed no diving depth markers not a 6x6 tile. Sticker was 5 x 3/4 inch. Tile shall be at least 6"x6" tile. #5) Observed no general comment area on daily record sheet. Suggest providing general comment area to log book. #15) Observed the rope on the ring buoy starting to fray. Replace with 24ft rope by the next site visit. #25) Observed wet chemicals stored above dry chemicals in the chemical storage room. Both containers are in water proof materials as not to prevent a direct hazard. Store as to not present a hazard. Observed paper towel dispenser in the womens' restroom not operable. Intent to suspend issue for doors not self latching and self closing and not having an extra pump basket. Inspection completed by Kiana Chrisp and supervised by Katie Wilson
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing, self-latching. Observed the main door to the pool not self latching. Observed the door leading to the pump room not self latching. Intent to suspend issued.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(e) Provide a spare basket for pump. Observed no extra pump basket for the pool pump. Operate could not locate an extra basket. Intent to suspend.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2626(i) Water in restrooms shall not exceed 110 F. Observed water in the womens' restroom at 129F.

View this inspection on the county portal ›

Nov 5, 2018 16 demerits · 5 violations
Inspector comments: Intent to Suspend issued for test kit and deck dains. Paint LRV required within 30 days. Notice of Regulatory Requirement issued at time of inspection. At time of inspection, observed bonding wire for pump not one continuous wire. Wire was twisted to connect. Referral to Code Enforcement for action. Per Code Enforcement, twisting of wire is not correct bonding.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Test kit with black build-up in colander for cyanuric acid. Replace test kit. Intent to suspend issued. .2535(10) Provide test kit capable of measuring disinfectant level, cyanuric acid and total alkalinity.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Some chipping paint on pool floor and pool steps. No hazard to public.2537(14) Keep pool surface and pool floor free of debris. Blue paint used on pool floor. Provide Light Reflectance Value testing for paint used within 30 days. Pool paint shall reflect at least 50% of light. .2514(c) Pool finish shall be white or light colored.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed planter at 4.5 ft from pool. Corrected during inspection. .2522(b) Provide at least 5 ft of clear walking space around the pool at all times. Deck drain painted over in some locations. Pool shall drain to deck drains. Drains do not drain properly due to paint. .2522. Intent to Suspend issued.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Pump room floor wet due to leaking hose bib. .2533(d) Pump room floor shall be kept dry and free of standing water. Pool equipment not easily accessible. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Water in restrooms greater than 110 F. .2626(i) Water in restrooms shall not exceed 110 F.

View this inspection on the county portal ›

Feb 27, 2018 12 demerits · 2 violations
Inspector comments: Inspection completed by Tim Gentry.
#3 · Water quality: pool water pH −6
Observed PH at 7.0. Corrected to 7.3.
#22 · Premises: emergency telephone provided −6
Observed emergency phone not working. Corrected by PIC during inspection.

View this inspection on the county portal ›

Sep 11, 2017 12 demerits · 4 violations
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Some damage to deck paint around drains. Keep in good repair.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter stuck. Keep operational.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Provide 3 ft clearance around the equipment in the pump room. Observed some piping on floor in pump room.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Water in restrooms >115 F. No paper towels in women's restrooms. Corrected during inspection. Maintain water at 110 F or below.

View this inspection on the county portal ›

Feb 9, 2017 10 demerits · 3 violations
Inspector comments: 30 - General Comment: Check valve on fill line ASSE 1015 which is no approved check valve. Pool built prior to 2010. If replaced, replace with approved check valve.
#13 · Pool maintenance: contrasting band on steps and benches −4
Paint on steps does not extend on top step all the way to wall. Contrasting color band must extend to no greater than 1" from pool wall. Repaint by next inspection.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter stuck. Keep operational.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Water in rest.rooms >120 F. Maintain at 110 F or below.

View this inspection on the county portal ›

Nov 21, 2016 12 demerits · 4 violations
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Plant on pool deck at 4.5 ft to pool. Maintain 5 ft clearance around pool. Deck drains covered with paint in some locations. Repair deck so drains properly. Intent to Suspend issued.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter not operational. Repair.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Water in restrooms >110 F. Maintain at 110 F or below.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
Check valve on the fill line ASSE 1015. Built prior to current regulations. Provide check valve compliant with .2512.

View this inspection on the county portal ›

Jun 1, 2016 10 demerits · 3 violations
Inspector comments: PDSC form verified in field. 3/4 hp motor on a 1/2 hp pump. Pump has not been changed since previous visit. No model number on pump.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Deck drains painted over. Facility recently painted deck. Assure slip resistance and keep drains clear.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter stuck. Keep operational.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Water greater than 120 F. Maintain at 110 F or below.

View this inspection on the county portal ›

Sep 21, 2015 12 demerits · 3 violations
Inspector comments: Immediate Suspension issued for pool phone. Once corrected, contact Katie for a return visit to re-open pool.
#22 · Premises: emergency telephone provided −6
Emergency phone not operable. Get busy single when dials out to 911. Immediate Suspension issued.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter not operating. Keep operational. Multi-port leaking. Repair leak.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Water in restrooms >120 F. Maintain at 110 F or below.

View this inspection on the county portal ›

Feb 5, 2015 8 demerits · 3 violations
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter stuck. Keep operational.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
3 ft clear walking space not provided in pump room.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Water >115 F in restrooms. Maintain at 110 F or below.

View this inspection on the county portal ›

Nov 13, 2014 10 demerits · 3 violations
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Body hook pole collapsable. Corrected.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Provide 3 ft clear walking space around equipment.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Water >113 F. Maintain water at 110 F or below.

View this inspection on the county portal ›

Jun 3, 2014 8 demerits · 3 violations
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed flow meter stuck. Keep operational.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Provide 3 ft clear walking space around all pipes/valves.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Observed water at >120 F. Maintain at 110 F or below.

View this inspection on the county portal ›

Nov 25, 2013 4 demerits · 2 violations
Inspector comments: 22 - General Comment: Pool phone on trunk line. Provide designated line by Dec 9.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed pump room floor wet. Keep dry.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Observed water in restrooms at >120 F. Maintain at 110 F or below.

View this inspection on the county portal ›