HUNTERSVILLE FAMILY FITNESS - LAP

11725 VERHOEFF DRIVE, Huntersville, NC 28078
Year-Round Swimming Pool · NC permit/State ID 2060530143
Latest result12 demerits
Last inspectedSep 8, 2026
Inspections on record28
On record sinceSep 26, 2013

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

01734 Sep 26, 2013: 30Mar 17, 2014: 16Oct 28, 2014: 24Mar 18, 2015: 8Dec 9, 2015: 16Apr 7, 2016: 22Nov 2, 2016: 8Apr 27, 2017: 16Nov 1, 2017: 22Jan 24, 2018: 32Nov 5, 2018: 6Mar 20, 2019: 2Oct 17, 2019: 10Jan 9, 2020: 10Aug 5, 2020: 10Dec 8, 2020: 22Jan 28, 2021: 34Nov 10, 2021: 8Feb 23, 2022: 22Oct 19, 2022: 20Mar 22, 2023: 6Dec 13, 2023: 22Apr 24, 2024: 18Dec 10, 2024: 28Apr 3, 2025: 6Nov 17, 2025: 6Feb 23, 2026: 10Sep 8, 2026: 12
Sep 26, 2013Lower is betterSep 8, 2026

Inspections & violations

Sep 8, 2026 12 demerits · 3 violations
Inspector comments: MAIN DRAIN COVERS EXPIRE 12/11/2028 INTENT TO SUSPEND ISSUED FOR THE DOOR NOT SELF-CLOSING AND FOR THE DEPTH MARKERS BEING MORE THAN 25 FEET APART. DEADLINE IS 10/8/20206. FAILURE TO CORRECT THESE ISSUES BY THE DEADLINE WILL RESULT IN THE CLOSURE OF THE POOL UNTIL CORRECTIONS ARE MADE. Resurface of pool deck requires infield plan review application prior to work - 2025New pump to be installed - requires electrical IFPR approval and field verification for final approval - 2025Permit Restriction - Flow meters must remain operable on each system. Flow not to exceed 1330 gpm (SCH80) due to flow restriction of the filter. Turnover - Combined flow of 2617 gpm. Flow greater than 1531 gpm exceeds the main drains. Suction Hazard. FLOW OF PUMP A WAS 1150 GPM FLOW OF PUMP B WAS 1200 GPM.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
.2523(a) Depth of the water shall be marked at or above the water surface on the vertical wall of the pool and on the edge of the deck next to the swimming pool. .2523(b) Provide depth markers spaced not to exceed 25 feet when measured along the perimeter of the pool. .2523(c) Depth markers shall be 4 inches in height and of a contrasting color with the background, clearly visible. .2523(c) Depth markers shall include the word "feet" or symbol "ft". Observed 2 depth markers at the diving boards to be 25 foot 8 inches apart. A marker must be added to the deck and the pool wall such that the distance between the markers is less than 25ft.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
One door to the outside on the exterior wall with the bleachers is not self-latching. .2537(b) All gates and doors shall be self-closing, self-latching. Intent To Suspend Issued.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed some holes in the deck where the deck plugs were missing. These present trip hazards. Corrected during the inspection. .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile.

View this inspection on the county portal ›

Feb 23, 2026 10 demerits · 3 violations
Inspector comments: Inspection conducted with George Evermann and CPO Kristen Sminchak. FloVis flow meters installed. Pump A at 900 GPM, Pump B at 1050 GPM. Combined 1,950 GPM.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
Numbering missing from one of the depth markers on the pool wall. .2523(c) Depth markers shall be 4 inches in height and of a contrasting color with the background, clearly visible. - Corrected.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Some ladder handrails loose. .2521 Install ladders per manufacturer instructions.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
One door to outside not self-latching. .2537(b) All gates and doors shall be self-closing, self-latching. - Corrected.

View this inspection on the county portal ›

Nov 17, 2025 6 demerits · 1 violation
Inspector comments: Inspection conducted with inspector Niejel Wilkins, George Evermann, and CPO Kristin Sminchak. Inspection led by Niejel Wilkins. Permit restriction that flow meter remain operable on both systems not to exceed 1330 GPM due to flow restriction of the filters. Observed 1200 GPM on pump A and 1050 GPM on pump B. Motor replaced for pump B. Electrical permit COM-ELC-25-004812 passed inspection on 10-3-2026.
#22 · Premises: emergency telephone provided −6
Phone number that 911 has does not match. .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. - Corrected.

View this inspection on the county portal ›

Apr 3, 2025 6 demerits · 2 violations
Inspector comments: Inspection conducted with CPO Kristin Sminchak. Observed flow meter for pump A at 950 GPM and pump B at 970 GPM.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
Numbering missing from two of the depth markers on the pool wall. .2523(c) Depth markers shall be 4 inches in height and of a contrasting color with the background, clearly visible. - Corrected.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Some ladder handrails loose. .2521 Install ladders per manufacturer instructions.

View this inspection on the county portal ›

Dec 10, 2024 28 demerits · 7 violations
Inspector comments: Inspection conducted with George Evermann and CPO Kristen Sminchak. Inspection led by inspector Casey Aitcheson. New 30 HP replacement pump for system A installed. Verified permit E4549092 passed electrical inspection on 1-19-2024. Cut sheet for new pump submitted. Also need updated PDSC form and In-Field Plan review applications for new pump. Failure to get this documentation to the Health Department and approved will result in the permit being suspended. Forms emailed to CPO Kristen Sminchak. Verified Pump A and Pump B at 1200 GPM after a backwash. Blue-White Flow meter accurate to within +/- 10% accuracy. May need to be replaced to one that is accurate to within +/- 5%. Intent to suspend issued 9) 17)
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
Replacement pump for pump system A installed. PDSC and In-Field Plan Review application not yet submitted for approval. .2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance. - Will follow up with the facility to ensure compliance.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
Numbering missing from one of the depth markers on the pool wall. .2523(c) Depth markers shall be 4 inches in height and of a contrasting color with the background, clearly visible. - Intent to suspend item.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Some ladder handrails loose. .2521 Install ladders per manufacturer instructions. Some starting platforms accessible. .2517(e) Secure starting platforms from use by removal; covering; or signage and active supervision. Some of the diving boards with non-slip tread wearing thin or starting to chip off. .2517(a)4 Diving equipment shall be slip-resistant.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
One door from hallway and one door to outside not self-closing and self-latching. .2537(b) All gates and doors shall be self-closing, self-latching. - Corrected.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Some deck anchors missing. .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. - Corrected. One lane line reel stored too close to diving board. Insufficient deck clearance. .2522(b) Provide at least 5 ft of clear walking space around the pool at all times. - Intent to suspend item.
#22 · Premises: emergency telephone provided −6
Phone number that 911 has does not match. Number does not call back to the facility. .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. - Corrected. Temporary phone placed by emergency phone until it is fixed.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Hot water 120.5F. .2526(i) Water in restrooms shall not exceed 110 F.

View this inspection on the county portal ›

Apr 24, 2024 18 demerits · 5 violations
Inspector comments: Inspection conducted with George Eversmann. Pump A - 1000 GPM, Pump B - 900 GPM. Facility using rubber mats at ladders due to the concrete becoming too worn down to be non-slip when wet. Maintain rubber mats such that they do not create a trip hazard. Prior to resurfacing pool deck, submit in-field plan review application to ensure new deck meets Health Department requirements. Intent to suspend issued 8) 11) 16)
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Gutter cover missing or popping up in places. Repair gutter to eliminate gaps and keep flush. Install per mfg. instructions. .2518(k)(2) The overflow trough shall be cleanable and maintained to minimize accidental injury. - Intent to suspend item.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Some ladder handrails loose. .2521 Install ladders per manufacturer instructions. 1 meter diving platform with wooden supports extending into the pool water. .2517 Diving equipment shall be designed for pool use and shall be installed in accordance with manufacturer’s recommendations and include a label with manufacturer’s name, address and equipment specifications. - Intent to suspend item.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
One body hook broke off of pole. .2530(a) Provide at least 12 ft. long pole with body hook securely attached. .2530(b) Two units of lifesaving equipment (or two lifeguards) must be provided for pools that exceed 3,000 sq. ft. surface area. - Corrected. Operator able to get body hook from outdoor pool which has not yet been permitted until a replacement is obtained.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
One door from hallway, back door, and door to office/locker rooms not self-closing and self-latching. .2537(b) All gates and doors shall be self-closing, self-latching. - Intent to suspend item.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Hot water 129.2F. .2526(i) Water in restrooms shall not exceed 110 F.

View this inspection on the county portal ›

Dec 13, 2023 22 demerits · 5 violations
Inspector comments: Inspection conducted with Aquatics Director Kristen Sminchak. Kristen is the new CPO for this pool. Updated CDP with CPO information. Flow meter for pump closest to heater reading 990 GPM. Permit condition for flow meter to be operational at all times at 900 GPM. Corrected to ~910 GPM. Facility changed main drains to what appear to be VGBA 2008 Aquastar 24xxx main drains. Will need to submit updated PDSC information to our office and receive approval by 12/18. Failure to do so will result in a suspension of the pool permit. Intent to suspend issued 5) 24)
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Records kept in 3 locations. Not checking temperature or main drains daily. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. - Intent to suspend item.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
Like for like change of main drains on 12/11/2023. PDSC paperwork not yet submitted for approval. .2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance. - Will follow up with the facility to ensure compliance.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Some ladder handrails loose. .2521 Install ladders per manufacturer instructions.
#22 · Premises: emergency telephone provided −6
Emergency phone not functioning. .2530(f) Emergency phone shall remain operable. - Corrected.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter for one of the pumps stuck. .2518(g) Keep flow meter operational. - Facility has ordered new flow meter. - Intent to suspend item.

View this inspection on the county portal ›

Mar 22, 2023 6 demerits · 2 violations
Inspector comments: Inspection conducted with CPO Anna Kirkland. Facility working on plumbing for water heater. Ensure hot water in restrooms and showers is no more than 110F. Flow meter for Pump A reading 850 GPM Flow meter for Pump B reading 890 GPM
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Missing some temperature checks. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Some ladder handrails loose. .2521 Install ladders per manufacturer instructions.

View this inspection on the county portal ›

Oct 19, 2022 20 demerits · 6 violations
Inspector comments: Inspection conducted with inspector Hope McIntosh and George Eversmann. Observed large fans placed by doors to outside, doors have door props installed. Ensure that doors remain self-closing and self-latching and remain closed when not being actively used. Recommend labeling outdoor pool piping to show which system it is tied to. Pump A operating at ~875 GPM. Pump B operating at ~800 GPM. Intent to suspend issued 9) 16) 17)
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
Numbering missing from one of the depth markers on the pool wall. .2523(c) Depth markers shall be 4 inches in height and of a contrasting color with the background, clearly visible. - Intent to suspend item.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Some ladder handrails loose. .2521 Install ladders per manufacturer instructions. Some starting platforms are usable, pool open for general swim. .2517(e) Secure starting platforms from use by removal; covering; or signage and active supervision.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
One door from hallway not self-closing and self-latching. .2537(b) All gates and doors shall be self-closing, self-latching. - Intent to suspend item.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Rubber mats placed by some of the ladders. .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. - Intent to suspend item. Missing one ground cover, another cover sticking up. .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. - Intent to suspend item.
#19 · Premises: signs prohibit glass containers or pets in pool area −4
Safety signage partially blocked by equipment. .2530(d) Provide easily visible signage prohibiting pets and glass containers in the pool area.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Hot water 116F. .2526(i) Water in restrooms shall not exceed 110 F.

View this inspection on the county portal ›

Feb 23, 2022 22 demerits · 7 violations
Inspector comments: Inspection conducted with Anna Kirkland, George, and Harold. Due to COVID-19 precautions, inspection not signed by the operator. NOTE** Verified that hose bibs are located under sinks in the locker rooms. Single restrooms are within 50 feet of hose bib in janitorial closet. Outdoor filter for pump B flooded, pump off for a portion of the inspection. Operator drained excess water with sump pump. Verified that pump and flow meter work properly. In 2021, a permit condition was added that pump A (pump closest to liquid chemical storage room) operate at 900 GPM per the engineer. Piping has since been added allowing water from heater and chlorinator to run through pump B, reducing the TDH for pump A. Observed pump A flow meter at 1100 GPM. Will follow up with our office to see what other impacts this change will have. Operator adjusted gate valve to reduce flow to 700 GPM for pump A. Intent to suspend issued. 8) 16)
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Water level 2 inches above the overflow trough. .2518(k) Water level shall be maintained such that overflow system is capable of providing continuous and automatic skimming action of the water at the surface of the pool. - Intent to suspend item.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Some ladder handrails loose. Tighten and keep in good repair. Some starting platforms are usable, pool open for general swim. .2517(e) Secure starting platforms from use by removal; covering; or signage and active supervision.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed doors to outdoor pool propped open. Corrected during inspection. .2537(b) All gates and doors shall be self-closing, self-latching. Some doors not self-closing, or not self-latching. .2537(b) All gates and doors shall be self-closing, self-latching. - Intent to suspend item.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Decking offset >1/2" at deck drain and deck near diving platforms. Offset is outside of required deck spacing. Boards stored near one of the diving boards. .2522(e) Provide at least 5 ft of clear walking space around diving board, handrail, slide, or other permanent structure on a swimming pool deck.
#21 · Premises: pool and deck lighting provided at pools that operate at night −4
Inadequate indoor ventilation. Pool room hot. Doors propped open with large fans. Provide proper indoor ventilation. .2524(f) Indoor pools shall have mechanical ventilation.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Inadequate ventilation in chemical storage room where pallets of dry chemical is stored. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Hot water > 120 F. .2526(i) Water in restrooms shall not exceed 110 F.

View this inspection on the county portal ›

Nov 10, 2021 8 demerits · 2 violations
Inspector comments: No signature per COVID guidelines.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Repeat: Observed buildup of debris on pool floor. .2537(14) Keep pool surface and pool floor free of debris.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed doors to outdoor pool propped open. Corrected during inspection. .2537(b) All gates and doors shall be self-closing, self-latching.

View this inspection on the county portal ›

Jan 28, 2021 34 demerits · 10 violations
Inspector comments: 5 - Test kit used by lifeguards in need of replacement. Tubes with build-up. Replace test kits. Note: No pressure gauges on filters. Original construction. Intent to Suspend issued for pool floor cleanliness and door self-closing, self-latching at first-aid room. Verified pumps as 30 hp pumps. Original plan approval shows Gould 30 hp pumps; however, documentation provided from operator shows the same pump. Pump motors installed do not verify with documents provided. Provide documentation of pump located nearest to building. Given 30 days. Jessica Martin present during the inspection. No signature due to covid restrictions.
#3 · Water quality: pool water pH −6
Pool pH at 8.0. Lowered to 7.6 during the inspection.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Debris build-up on bottom of pool floor especially in diving well area. Keep pool floor clean. Intent to Suspend issued.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Repeat Item - Damage to gutter near diving boards. >1/2" gap and popping up. Repair gutter to eliminate gap and keep flush. Install per mfg. instructions. Corrected during inspection. Pin added and additional gutter piece added.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
Multiple wall depth markers missing parts of lettering. All corrected during the inspection. 17 ft. blocked on deck from dive trampoline. Moved during inspection.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Some ladder handrails loose. Tighten and keep in good repair. Labeling not provided on dive equipment per rule requirements. .2517(a)3 Provide labeling affixed to diving equipment. Practice equipment located directly behind large diving board. Maintain 5 ft. clearance behind any diving equipment
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Door in first aid room not self-closing, self-latching. Repair to self-close, self-latch. Intent to Suspend issued.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Decking offset >1/2" at deck drain and deck near diving platforms. Offset is outside of required deck spacing.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Pump room outside without ceiling, walls, flooring sloped to drain, etc. Original construction. Pump room shall be maintained in accordance with .2533. Pump room left unlocked with chemical storage. Keep locked at all times when not in use.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Multiple shower fixtures leaking. Some build-up on shower fixtures. Keep all restroom fixtures clean and in good repair. Water in restrooms >130 F. Maintain at 110 F or below.
#33 · Dressing and sanitary facilities: hose bibbs and floor drains provided −2
No hose bib in pump room and no hose bib in women's locker room. Provide hose bibs with backflow prevention devices.

View this inspection on the county portal ›

Dec 8, 2020 22 demerits · 7 violations
Inspector comments: Note - Phone with static. 911 operator still clearly audible. Recommend replacing/verifying line to correct issue. Note: Diving platforms in water > 4 ft. shall measure no greater than 30" from waters edge. Jessica Martin present during the inspection. No signature due to covid restrictions. Intent to Suspend issued for door self-closing, self-latching and repair to gutter.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Temperature not recorded daily. Maintain daily record keeping for temperature.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Damage to gutter near 17 ft at stairwell. Repair damage to gutter. Intent to Suspend issued.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Practice platforms without covering, signage or removal. Not in use at time of inspection. .2517(e) Secure starting platforms from use by removal; covering; or signage and active supervision. One ladder handrail loose at deep end of pool.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
One door nearest office not self-latching. Repair to self-close, self-latch. Intent to Suspend issued.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Practice equipment located directly behind large diving board. Maintain 5 ft. clearance behind any diving equipment. Caps missing from holes in pool deck for equipment. Plugged during inspection.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Equipment room outdoors without ceilings, walls, etc. Original construction. .2533(a) Pump room shall be weatherproof with a minimum ceiling height of 7 ft. Pump room area left unlocked. Keep locked when not in use.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Water in restrooms at exceeds 115 F. Maintain at 110 F or below.

View this inspection on the county portal ›

Aug 5, 2020 10 demerits · 3 violations
Inspector comments: Intent to suspend for doors between indoor and outdoor pools not self closing self latching. Contact Chris Sells when repairs are complete at 704 576 8678
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed doors not alarmed or latchingbetween outdoor and indoor pool. Intent to suspend .2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed leak in chlorinator line and leak in filtration line. .2518 Keep piping in good repiar.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Facility built without pump room enclosure. .2533(a) Pump room shall contain at least all pumps, chemical feeding equipment, and other mechanical and electrical equipment.

View this inspection on the county portal ›

Jan 9, 2020 10 demerits · 2 violations
Inspector comments: Observed new chlorinator installed not approved by the Department. Send in manufacturer instructions and pool volume to christopher.sells@mecklenburgcountync.gov for review and approval within 30 days. Verified PDSC information.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Observed total alakinity missing for some weeks. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed one life guard on duty no ring buoy, pool over 3000sqft. Second life guard in place during inspection. .2530(a) Lifesaving equipment includes body hook and pole and USCG approved ring buoy with required rope length. .2530(b) Two units of lifesaving equipment (or two lifeguards) must be provided for pools that exceed 3,000 sq. ft. surface area. Life guards replace one ring buoy each.

View this inspection on the county portal ›

Oct 17, 2019 10 demerits · 3 violations
Inspector comments: Some of the depth markers on the walls starting to peel. Maintain depth markers. Intent to suspend issued. 11) 16)
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Most handrails loose. Maintain secure and in good condition. Diving board with non-slip coating missing in places. .2517(a)4 Diving equipment shall be slip-resistant. - Intent to suspend item.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
One of the doors to the hallway not self-latching. .2537(b) All gates and doors shall be self-closing, self-latching. - Intent to suspend item.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
One of the flow meters stuck. .2518(g) Keep flow meter operational.

View this inspection on the county portal ›

Mar 20, 2019 2 demerits · 1 violation
Inspector comments: Flow meter for one of the pumps reading 900 gpm, flow meter for other pump fluctuates between 500 and 600 gpm. Spoke with Jessica, planning to do pump maintenance and possibly replace impeller for underperforming pump. If pump is changed out, submit in field plan review to Environmental Health to ensure that pump is properly sized. Verified new main drains installed are Aquastar 24xxx.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Hot water in the restrooms > 110F. Maintain at no more than 110F.

View this inspection on the county portal ›

Nov 5, 2018 6 demerits · 2 violations
Inspector comments: Recieved complaint of poor indoor air quality. Air handler working today, but there have been recent issues. Ensure proper ventilation and ensure that bathers are showering before entering the pool. Observed shower signage posted and showers in good working order. Main drains expire March 10, 2019. Replace with A112 approved main drains and submit updated PDSC form to Environmental Health.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Some ladders loose. Install ladders per manufacturer instructions.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Some caps missing from deck and some gaps between sections of gutter grates. Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. Corrected by operator.

View this inspection on the county portal ›

Jan 24, 2018 32 demerits · 8 violations
Inspector comments: 6 - PDSC form only indicates one pump with two present. Given one week to provide updated VGB paperwork with correct pump information including pump curves. Provide updated PDSC form. 23 - Chlorinator automated - could not be verified during inspection. Pool was open to public and filtration would have had to be shut off in order to verify. 33 - Hose bib present in women's restroom. Provide hose bib within 50 ft. of men's restroom. Intent to Suspend issued for gutter rung, depth markers, doors self-closing, self-latching and plugs on deck. (4) 24xxx and (2) Paddock? pumps, 30 hp?
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Some gutter rungs >1/2" between due to shifting. Repair openings to ensure no greater than 1/2" openings on pool gutters to eliminate pinch hazard. Intent to Suspend issued.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
Multiple damaged depth markers on pool gutter wall where sticker has come off. Provide 4" lettering for depth markers on pool wall in all locations where damaged. Intent to Suspend issued. Depth markers on pool deck covered with mats. Keep visible. Corrected during inspection.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Multiple ladder handrails loose. Tighten and keep in good repair. Diving platforms not in use with no labeling. Provide removal, covering or signage and activie supervision. No labeling on diving boards. Provide per .2517.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
One ring buoy rope >50 ft. in length. Corrected to 50 ft. during inspection. Ropes for ring buoys tangled. Keep accessible. Correted during inspection.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Two doors from pool deck to outdoor pool area not self-latching. Repair to self-latch, self-close or audible alarm. Intent to Suspend issued.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Diving practice equipment located directly next to diving boards. Provide 5 ft. clearance directly around all diving equipment. Bulkheads and decking with missing plugs for diving platforms that were not in place. Provide no openings >1/2" on pool deck. Provide plugs. Intent to Suspend issued.
#22 · Premises: emergency telephone provided −6
Emergency phone with incorrect phone number. Facility has temporary phone from aquatics office. Pool phone deck not operational. If changed back to original pool phone, re-verify phone number. Number corrected on pool signage to correct number during the inspection.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Pump room located outside and does not meet design specifications for pump room or chemical storage per .2533 and .2534.

View this inspection on the county portal ›

Nov 1, 2017 22 demerits · 6 violations
Inspector comments: Updated CPO information to reflect that Jessica Martin is the CPO.
#2 · Water quality: disinfectant residual provided by −6
Cl 0.7. Maintain at least 1ppm free chlorine. Corrected to 1ppm.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Spotty temperature logs. Temperature is checked and recorded daily on wall. Ensure that these are recorded in the pool log sheet as well.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Ladders loose. Maintain secure and in good condition.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Gutter cover with gaps > 1/2 inch. Maintain gutter cover in good condition with no gaps > 1/2 inch to eliminate trip hazards.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter stuck. Repair or replace.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Hot water > 110F. Maintain hot water at no more than 110F. One of the showers on the pool deck leaking. Fix leak.

View this inspection on the county portal ›

Apr 27, 2017 16 demerits · 5 violations
Inspector comments: Intent to suspend issued. 16) 17) 24)
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Some of the ladders loose. Maintain secure and in good condition.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Some of the doors do not latch. Ensure all doors are self-closing and self-latching. - Intent to suspend item.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Some of the deck drains damaged, with openings > 1/2". Ensure that deck drains are in good condition and are not a trip hazard. - Intent to suspend item.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Unable to read one of the flow meters, numbers worn off. Other flow meter missing the bobber. Install functional flow meters for each of the pumps. - Intent to suspend item.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Hot water in restroom > 110F. Maintain at 110F or less.

View this inspection on the county portal ›

Nov 2, 2016 8 demerits · 3 violations
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Some ladders loose. Maintain secure and in good condition.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
One flow meter missing metal piece. No longer able to read the numbers on the other flow meter. Replace both with functional flow meters.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Hot water > 110F. Maintain at 110F or less.

View this inspection on the county portal ›

Apr 7, 2016 22 demerits · 6 violations
Inspector comments: 5) Sporatic total alkalinity checks. Check at least weekly total alkalinity. Recommend having a spot on the log sheet for total alkalinity checks.Intent to suspend issued.16)
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Some of the handrails are loose. Maintain secure and in good condition.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Pool with one body hook on pole at least 12 feet long. Other body hook on 9 1/2 feet long pole. Provide at least two body hooks on non-collapsible poles at least 12 feet long. Corrected.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Some of the doors not self-cosing and self-latching. All doors to pool area shall be self-closing and self-latching.
#22 · Premises: emergency telephone provided −6
No dial tone on phone. Provide functional emergency phone. Corrected by operator.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Washing machine stored in chemical storage room. Remove washing machine.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Hot water > 110F. Maintain at 110F or less.

View this inspection on the county portal ›

Dec 9, 2015 16 demerits · 5 violations
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Some ladders loose. Maintain secure and in good condition.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
One of the latches on one of the doors broken. Repair.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Not enough deck clearance near trampolines and lifeguard tower. Corrected by operator.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter for secondary pump no longer readable. Most of the numbers missing. Replace flow meter.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Spilled bag of chemicals on the ground. Clean up spill. Maintain storage room clean with dry chemicals in buckets or on pallets.

View this inspection on the county portal ›

Mar 18, 2015 8 demerits · details not yet loaded

Violation details for this inspection are not yet loaded on this site. We're still importing older records — check the official county portal for the full report.

Oct 28, 2014 24 demerits · details not yet loaded

Violation details for this inspection are not yet loaded on this site. We're still importing older records — check the official county portal for the full report.

Mar 17, 2014 16 demerits · details not yet loaded

Violation details for this inspection are not yet loaded on this site. We're still importing older records — check the official county portal for the full report.

Sep 26, 2013 30 demerits · details not yet loaded

Violation details for this inspection are not yet loaded on this site. We're still importing older records — check the official county portal for the full report.

Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “HUNTERSVILLE FAMILY FITNESS - LAP” or State ID 2060530143). Inspection type (routine vs. follow-up) is not published in the county's data.