26demerits
HALTON PARK APARTMENTS
17701 HALTON PARK DR, Charlotte, NC 28262
Year-Round Swimming Pool · NC permit/State ID 2060530216
Latest result26 demerits
Last inspectedOct 12, 2026
Inspections on record25
On record sinceJul 17, 2013
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Jul 17, 2013Lower is betterOct 12, 2026
Inspections & violations
Oct 12, 2026 26 demerits · 6 violations
Inspector comments: Inspection completed with Vernice Hixon present.
Permit suspended for chlorine tablets inside skimmer baskets. Ensure all chlorination happens through automatic chlorine feeder system. Once corrected, contact Eli Freese at 704.621.2298 to verify and reopen pool. Maintain pool closed signs posted.
Items listed below this line are 30 day intent to suspend items. The 30 day intent to suspend will go into effect once the permit suspension is lifted if not corrected before then.
1. Inadequate record keeping. Ensure chlorine, pH, and main drain safety checks are recorded daily when the pool is open. Ensure total alkalinity and cyanuric acid are recorded at least weekly.
2. Window leading from gym to pool deck not limited to opening 4 inches or less.
3. Non operational flow meter.
#2 · Water quality: disinfectant residual provided by −6
G.S. 130A-2(3) Chlorine added directly to swimming pool. Chlorination must occur through NSF approved chlorinator. Eliminate direct hazard to public. Observed chlorine tablets in skimmer baskets. Permit suspended.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Observed inadequate record keeping for months of September and October 2026.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed 1 ladder with damaged rung (foothold). Repair.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Ground level windows shall not open greater than 4" on to pool deck or child protected by audible alarm. Observed 1 window in gym area that leads directly to pool deck not limited to opening 4 inches or less.
#22 · Premises: emergency telephone provided −6
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Observed incorrect phone number posted. CDI- correct phone number posted.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep the flow meter operational. Observed the flow meter non operational.
May 5, 2026 28 demerits · 6 violations
Inspector comments: OBSERVED PDSC FORM TO BE INACCURATE AS TO THE EQUALIZER LINE COVERS. EQUALIZER LINES IN THE POOL ARE PLASTERED OVER AND PLUGGED IN THE SKIMMERS. THE PDSC FORM SAYS THE POOL HAS 5 OPERABLE SKIMMERS WITH AQUASTAR 6HPHA COVERS. A NEW ACCURATE PDSC FORM MUST BE SUBMITTED THE THE HEALTH DEPARTMENT MAIN OFFICE AND APPROVED BY 5/12/2026 OR THE POOL WILL BE CLOSED.
THE MAIN DRAINS COVERS EXPIRE 5/16/2030
ENSURE THAT ANY WINDOWS THAT OPEN ONTO THE POOL DECK DON’T OPEN MORE THAN 4 INCHES.
THE POOL IS NOT APPROVED FOR NIGHT SWIMMING. THE SIGNS ON THE POOL INDICATE THE POOL IS OPEN UNTIL 10PM. THE SIGNS MUST BE CHANGED TO REFLECT THAT THE POOL CANNOT BE OPEN FOR SWIMMING AFTER DUSK OR BEFORE DAWN.
POOL HAS A DEADLINE TO CORRECT THE DEPTH MARKER, THE FLOW METER, THE DOORS ONTO THE POOL DECK, AND THE VACUUM LINE CAP. DEADLINE IS 6/4/2026. POOL ALSO WILL NOT BE ISSUED A NEW PERMIT ON JUNE 1ST 2026 IF CORRECTIONS ARE NOT MADE BEFORE THEN. POOL WILL BE CLOSED DUE TO THE NEW PERMIT NOT BEING ISSUED.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Observed pH to be 6.8 upon arrival. It was corrected to 7.5 -CDI
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. Observed 1 weir missing out of 5 total. Replace the missing weir. No permit action taken.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
.2523(b) Provide depth markers spaced not to exceed 25 feet when measured along the perimeter of the pool.
.2523(c) Depth markers shall be 4 inches in height and of a contrasting color with the background, clearly visible.
Observed missing depth marker on the deck next to the stairs at one of the 3 foot ends of the pool making the distance between them 29 feet. Provide a correct marker at the correct distance.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Fence is not built to current specifications. The are less that 45 inches between horizontal fence pieces. No permit action taken. Pool was built prior to 2010.
.2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm.
Observed men’s bathroom door not self-closing and party room door not self-latching or audibly alarmed. Correct these doors.
#22 · Premises: emergency telephone provided −6
Incorrect phone number posted at emergency phone. Corrected onsite. -CDI
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone.
Correct phone number was determined to be 704-937-1367.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Observed flow meter to be stuck. Correct the flow meter. Pool does not have a flow restriction.
.2518(f) Provide a vacuum cap or self-closing cap for pools built after May 1, 2010.
Observed vacuum line cover to have a lid that is no longer latching. Pool was built prior to 2010 and can have either a cap with a latching lid, or a solid screw in plug as long as neither protrude more that 2” into the pool from the wall. Either provide a cap with a latching lid or a solid screw in cap.
Oct 9, 2025 16 demerits · 3 violations
#3 · Water quality: pool water pH −6
Observed pH at 6.8. Adjusted onsite to 7.2.
.2535(1) Maintain pH at 7.2 to 7.8.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Observed weekly records for total alkalinity and cyanuric acid and daily records for main drain checks missing for the past few weeks. Maintain as required.
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Throw rope extremely tangle. Keep in good repair and untangled. Corrected onsite.
Feb 25, 2025 22 demerits · 5 violations
Inspector comments: Issued immediate suspension for pH (.2535) and Kings III (.2530). Pool is to remain closed until items are corrected. Once corrected, please call James Bjorneboe at 704-507-6820 to schedule re-visit.
#3 · Water quality: pool water pH −6
Observed pH at 6.8. Maintain pH between 7.2-7.8.
.2535(1) Maintain pH at 7.2 to 7.8.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed 1 of 5 weirs missing in skimmers. Replace.
.2518(k) Replace missing weirs.
#18 · Premises: lifeguards present or warning signs posted −4
Lifeguard signage missing “WARNING”. Provide correct signage in 4” lettering.
.2530(c) Provide "Warning - No Lifeguard on Duty" in 4" lettering.
#22 · Premises: emergency telephone provided −6
Kings III operator was able to verify address but was not able to connect to local 911. Correct issue.
.2530(f) Pool telephone shall be capable of directly dialing 911 or another emergency notification system.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed water on pump room/ chemical room floor. Repair leak.
.2533(d) Pump room floor shall be kept dry and free of standing water.
Oct 29, 2024 18 demerits · 4 violations
Inspector comments: Issued intent to suspend for faded depth markers on pool wall. Please correct items within 30 days. Please call James Bjorneboe at 704-507-6820 once markers are in place to schedule re-visit.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
Observed two depth markers on pool wall on left end of the pool severely faded. Replace tiles.
.2523(a) Provide depth markers on pool walls and pool deck at both ends of the pool.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Ring buoy rope tangled. Corrected during inspection.
#22 · Premises: emergency telephone provided −6
Incorrect phone number posted at emergency phone. Corrected onsite.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed water on pump room and chemical room floor. Repair leak.
.2533(d) Pump room floor shall be kept dry and free of standing water.
Feb 8, 2024 20 demerits · 5 violations
Inspector comments: Inspection led by Emily Hartis under supervision of J. Bjorneboe.
Observed small chip in deck on right side. Repair.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Observed a pH of 8.2 at time of inspection. Immediate suspension issued.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Observed intermittent daily records and missing total alkalinity and acid records.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521(b) Ladders shall have slip-resistant tread. Observed ladder closest to fence missing slip resistant tread on 2 of the stairs.
.2521 Install ladders per manufacturer instructions. Observed ladder closest to entry doors without end caps.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
.2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. Observed one inlet cover missing. Replace.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Unable to determine if gates are self closing, self latching due to bike locks. Ensure gates are unlocked when pool is open.
.2537(b) All gates and doors shall be self-closing, self-latching.
Nov 9, 2023 18 demerits · 4 violations
Inspector comments: Issued immediate suspension for throw rope and pH. Pool is to remain closed until items are corrected. Call James Bjorneboe once items are repaired at 704-507-6820.
#3 · Water quality: pool water pH −6
Observed pH at 6.8. Maintain pH between 7.2 and 7.8.
.2535(1) Maintain pH at 7.2 to 7.8.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed 1 of 5 skimmers missing weirs. Replace missing weirs.
.2518(k) Replace missing weirs.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed one ladder missing end caps and other ladder missing tread on 2 of 3 rungs. Replace missing end caps and treads.
.2521 Install ladders per manufacturer instructions.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed throw rope extremely tangled. Ensure that throw rope is 45 feet in length and kept in good condition at all times
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less.
Feb 20, 2023 16 demerits · 4 violations
#2 · Water quality: disinfectant residual provided by −6
Observed chlorine at 0.5 ppm. Chlorine must be at least 1.0ppm. Adjusted to 1.0ppm onsite.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Observed 3 days of records missing in February. Keep and maintain required records on a daily basis.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed end caps missing on one ladder. Replace missing end caps.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
Observed 1 inlet cover missing. Replace missing inlet cover.
Dec 12, 2022 22 demerits · 5 violations
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Observed no records total alkalinity and cyanuric acid for December. Keep and maintain these records on a weekly basis.
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed 1 of 5 weirs missing. Replace missing weirs. Observed debris in skimmers. Keep skimmer free of debris.
.2518(k) Replace missing weirs.
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
End caps missing on 1 ladder. Replace missing end caps.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Throw rope observed at 60 feet long. Shortened to 45 feet on site. Throw rope was also extremely tangled. Corrected on site.
#22 · Premises: emergency telephone provided −6
Phone number posted at emergency phone was very faded. Corrected on site.
Apr 14, 2022 20 demerits · 4 violations
Inspector comments: General Comment: Observed 1 vertical depth marker in corner of pool starting to fade. Consider replacing.
#2 · Water quality: disinfectant residual provided by −6
Observed chlorine at 0.0 ppm. Adjusted to 1.2 ppm onsite
.2535(4) Maintain chlorine at least 1.0 ppm.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed 1 ladder missing end caps. Replace missing end caps. Also observed ladder > 6" from pool wall. Ladder rungs should be 3-6" from pool wall.
.2521 Install ladders per manufacturer instructions.
.2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed throw rope excessively tangled. Keep in good repair.
#22 · Premises: emergency telephone provided −6
Incorrect phone number posted at emergency phone. Corrected on site.
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone.
Apr 30, 2021 12 demerits · 3 violations
Inspector comments: General Comments: All required daily/weekly recordings are being kept. Missing rung replaced at ladder on far end of pool. All doors leading to pool are self closing/ self latching or audibly alarmed. Chlorination system has been fixed to where it shuts off when breaker is turned off. Local permit issued onsite.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed minor amount of debris in skimmers. Keep skimmers free of debris.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed 1 ladder missing an end cap. Replace missing endcap.
#22 · Premises: emergency telephone provided −6
Incorrect phone number posted at emergency phone. Corrected on site.
Oct 5, 2020 32 demerits · 9 violations
Inspector comments: 28 - Restrooms locked. Pool was currently not open to the public. If opened, restrooms must remain accessible at all times the pool is open to the public.
Ozrick Bennett present during the inspection. No signature due to covid restrictions.
Intent to Suspend issued for record keeping and doors self-closing, self-latching from men's restroom and fitness room.
15 - Replace ring buoy with USCG approved within 30 days. Will be verified on return visit. Current ring buoy has some parts falling off but is still usable.
#3 · Water quality: pool water pH −6
Pool pH at 6.8 at time of inspection. Raised to 7.2 during inspection.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Alkalinity checks not recorded weekly. Record weekly. Intent to Suspend issued.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
Some build-up starting on wall depth markers. Keep clean and clearly visible. Continue to monitor and clean as needed or if not visible.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
One ladder missing end cap and >6" from pool wall to ladder rung. Replace end cap and maintain 3" to 6" between wall and ladder rung.
One ladder with missing 3rd ladder rung. Replace prior to 2021 operating season.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
One wall return missing fitting. Replace fitting.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
<45" between horizontals on barrier. Plexiglass on gates into pool. Pool built pre-2010. Maintain 45" between horizontals.
Door from bathroom not self-closing, self-latching. Could not verify door from fitness room to self-close, self-latch. All doors on to pool deck shall be self-closing, self-latching. Intent to Suspend issued.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter stuck, not operational. Maintain operational flow meter.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Storage in chemical storage room. Chemical barrels stored in pump room. Maintain storage so that chemical storage room can be used for storage.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Hot water in restrooms >120 F. Maintain at 110 F or below.
Toilet seat loose in women's restroom. Keep fixtures in good repair.
Mar 2, 2020 6 demerits · 2 violations
Inspector comments: Equalizer covers are set to expire at the end of this month (March 2020). Replace equalizer covers and submit new PDSC form to this department. Form must be submitted and approved before permit for 2020 operating season is issued.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed minor amount of begris in skimmers. Keep skimmers free of debris.
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed missing end caps on one ladder. Replace. Observed missing rung on another ladder. Replace.
Nov 7, 2019 34 demerits · 8 violations
Inspector comments: Issued immediate suspension for #2, #3, and #15
#2 · Water quality: disinfectant residual provided by −6
Observed chlorine levels at 0.5 ppm. Maintain chlorine at least at 1.0ppm. Immediate suspension issued.
.2535(4) Maintain chlorine at least 1.0 ppm.
#3 · Water quality: pool water pH −6
Observed pH at 6.8. Maintain pH between 7.2 and 7.8. Immediate suspension issued.
.2535(1) Maintain pH at 7.2 to 7.8.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Observed no daily/weekly recording for November. Maintain required daily/weekly recordings.
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed end caps missing on one ladder. Replace end caps.
.2521 Install ladders per manufacturer instructions.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Throw rope extremely brittle and in poor condition. Replace with a 45 foot throw rope. Immediate suspension issued.
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed both gates open during inspection. One gate was not self-closing/ self- latching, repair.
.2537(b) All gates and doors shall be self-closing, self-latching.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed flow meter stuck. Repair.
.2518(g) Keep flow meter operational.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed bags of chemicals stored on the floor in chemical room. Store bags of chemicals off of the floor in chemical room.
.2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up.
Jan 14, 2019 12 demerits · 3 violations
Inspector comments: Issued immediate suspension for #3 (pH).
General Comment: Maintain weekly records for total alkalinty. Observed only records for cyanuric acid being kept weekly.
#3 · Water quality: pool water pH −6
Observed pH at 6.8. Maintain pH between 7.2 - 7.8. Immediate suspension issued
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed excessive debris in skimmers. keep skimmers free of debris.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed ladder missing endcaps. Replace missing caps.
Aug 16, 2018 46 demerits · 12 violations
Inspector comments: Newly installed pump and motor not bonded to the pool. Ensure that pump motor is properly bonded to the pool by a licensed electrician and inspected by Code Enforcement.
Lighting in and around the pool deck is not original lighting. Lighting with glass panes. Ensure that no glass is on the pool deck.
Restrooms remodeled. Provide either shatterproof mirrors or mirrors with safety tape backing and provide documentation to the Health Department.
Flow meter reads between 120 and 130 gpm. In field plan review lists pump designed to operate at 150 gpm with a minimum required flow of 142 gpm. Ensure that pump is properly sized for this pool and that equipment is functioning correctly.
Immediate suspension issued.
6)
15)
Contact Will Harrison (704-507-6824) when issues corrected for reinspection.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Spotty record keeping. Rarely check Total Alkalinity and Cyanuric Acid. Main drain cover damaged. Check daily Cl, pH, main drains and record daily pool maintenance activities. Check at least daily Total Alkalinity and Cyanuric Acid. Maintain Cyanuric Acid at no more than 100 ppm. - Intent to suspend item.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
Main drain cover damaged. Provide A112 approved main drains secure and in good condition. - Immediate suspension item.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Skimmers with debris. Clean regularly. One skimmer return mostly clogged with leaves. Provide functional skimmers.
Some skimmers missing weirs. Provide functional weirs. - Intent to suspend item.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
Depth marker on pool wall faded. Provide depth markers on 6x6 tile no more than 25 feet apart. - Intent to suspend item.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Ladders loose, missing endcaps, missing steps, and extending more than 6 inches into the pool. Provide ladders in good condition and extending 3-6 inches into the pool.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Fiberglass pole for body hook cracked. Provide body hook securely attached to 12 foot non-collapsible pole. - Immediate suspension item.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Section of fence behind bushes missing two pickets so that people can sneak into the pool. Provide fencing with no gaps > 4". - Intent to suspend item.
Both gates not self-closing and self-latching. Make gate self-closing and self-latching.
Windows from the clubhouse capable of opening more than 4 inches. Install window limiters or alarms so that windows cannot open more than 4 inches or alarmed to notify office staff that window is open. - Intent to suspend issue.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Gaps greater than 1/2 inch between sections of deck drains. Provide decking with no gaps or offsets > 1/2 inch. - Intent to suspend item.
#21 · Premises: pool and deck lighting provided at pools that operate at night −4
Pool not permitted for night swimming. Posted pool hours show that pool closes after dark. Change hours to reflect that pool is not permitted for night swimming. - Intent to suspend item.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Pressure guages for both pool filters not functioning. Provide working pressure guages for the filters. - Intent to suspend item.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Dry chemicals stored on the floor in the pump room. Store off the floor or in a bucket.
Liquid chlorine and liquid acid drums stored in the pump room. Store all chemicals in the chemical storage room.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Provide soap in men's restroom.
No toilet paper in men's restroom. Provide toilet paper.
Jan 29, 2018 6 demerits · 2 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed 1 of 5 weirs missing. Replace
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed water on pump room floor. Repair leak.
Jun 26, 2017 12 demerits · 3 violations
Inspector comments: Observed log book to have questionable entries. pH, cl2, and Main Drains must be checked and recorded daily. Total Alkalinity and Cyanuric Acid must be checked and recorded 1 time a week. Use the liquid test kit for all official testing, not the strips.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed 1 ladder missing the rubber feet. Replace them.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed body hook pole damaged. New pole (longer than 12ft.) was attached. -CDI
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed magnetic latch on 1 gate not operable. Either fix the magnetic latch or raise the mechanical gate latch so that the lowest point of the latch is 54 inches or higher above the ground. I.T.S. ISSUED
Nov 2, 2016 16 demerits · 4 violations
Inspector comments: POOL CLOSED TO SWIMMING
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Observed gaps in log book records. Properly perform and record the daily (cl2, pH, main drains) and weekly (TA+CA) checks.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed 1 weir missing out of 5 skimmers. Replace it.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed rubber feet missing from ladder. Replace them.
#22 · Premises: emergency telephone provided −6
Observed 911 KINGS III phone to transfer to a national 911 exchange. Once Char-Meck 911 was reached. Char-Meck 911 dispatch had no address or phone number for this pool. Char-Meck 911 must have proper address and call back number for this pool.
Jun 16, 2016 16 demerits · 4 violations
Inspector comments: Permit not posted. Go to Meckpools.charmeck.org and post copy in the pool area.
Immediate suspension issued.
22)
Contact Will Harrison (704-507-6824) when issues have been corrected for reinspection.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Some baskets dirty. Corrected by operator.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
One ladder missing endcaps. Same ladder with all steps loose. Maintain ladder in good condition.
#18 · Premises: lifeguards present or warning signs posted −4
Provide signage in at least one inch lettering stating "CHILDREN SHOULD NOT USE THE SWIMMING POOL WITHOUT ADULT SUPERVISION" - Intent to suspend item,.
#22 · Premises: emergency telephone provided −6
Kings III phone. When transferred to local 911 address listed is incorrect. 911 must have correct information and that information must be posted at emergency phone. - Immediate suspension item.
Aug 13, 2015 18 demerits · 5 violations
Inspector comments: Permit not posted. Go online to Meckpools.charmeck.org to print a copy of the pool permit and post in the pool area.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Baskets full. Clean regularly.One weir missing. Install functional weir.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Both ladders missing endcaps. Maintain ladders in good condition.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Throw rope 48 feet long. Rope shall be 45 feet long. Corrected by operator.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Pressure guage for one filter not functioning. Provide functional pressure guage for filter.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Light out in chemical storage room. Provide lighting for chemical storage room.
Mar 26, 2015 6 demerits · 2 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Missing one weir. Corrected by operator.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Both ladders missing endcaps. Corrected by operator.
Oct 1, 2014 20 demerits · 6 violations
Inspector comments: 15 - General Comment: Ring buoy with some damage. Replace by January 2015.
Intent to Suspend issued for #21
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Observed pH recorded at 7.0 for previous two weeks. Tested at 7.4. Provide accurate records.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
One skimmer without a weir and some build-up under skimmer baskets. Replace weir and keep clean.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Two ladders without end caps and one ladder missing rung. Replace/repair.
#21 · Premises: pool and deck lighting provided at pools that operate at night −4
Pool lights not operable. Pool operates 10:00 to 10:00. Repair lights. Intent to Suspend issued.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Operator stated multi-port was leaking when backwashing. Repair. Floor was wet.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Pump room floor wet. Keep dry.
Apr 1, 2014 0 demerits · 0 violations
No violations were recorded for this inspection.
Jul 17, 2013 24 demerits · 7 violations
Inspector comments: 7 - General Comment: Observed some debris on pool floor. Keep clean.
#2 · Water quality: disinfectant residual provided by −6
Observed disinfectant at 0.4 ppm. Corrected to 1.0 ppm.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed one weir missing from skimmer and one skimmer with build-up under basket. Replace weir and keep clean.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed end caps missing from ladders. Replace.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed left gate not self-latching. Repair. Intent to Suspend issued.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed some damage to concrete on deck. Keep in good repair.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed chemicals stored in pump room. Provide separate storage. Note: Store dry chemicals above liquid.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Observed water in restrooms >115 F. Maintain at 110 F or below.
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “HALTON PARK APARTMENTS” or State ID 2060530216). Inspection type (routine vs. follow-up) is not published in the county's data.