20demerits
ASHTON SOUTH END
125 W TREMONT AVE, Charlotte, NC 28203
Year-Round Swimming Pool · NC permit/State ID 2060530220
Latest result20 demerits
Last inspectedAug 20, 2026
Inspections on record27
On record sinceOct 30, 2013
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Oct 30, 2013Lower is betterAug 20, 2026
Inspections & violations
Aug 20, 2026 20 demerits · 4 violations
Inspector comments: Conducted inspection with CPO Stephen Gray.
All immediate suspension items were corrected during the inspection.
Pool heated but heater not currently operating.
Filtration pump meter: 70 gpm. This is not a suction hazard. The filter can be damaged. Recommend lowering to keep system operating properly.
Feature Flow meter: 110gpm
Permit Restriction: 1) Filtration Pump - Flow meter must remain operable. Flow required at 52 gpm to 63 gpm to meet turnover and flow restriction of the filter. 2) Feature A - Flow meter must remain operable not to exceed 119 gpm due to drain cover flow restriction. Suction Hazard. Fire pump tied to drains. Pump located on lower level. Patterson FP[1]C0178833-01350 hp pump. Const. Date: 5/27/2009 Rope Length: 27' Night Swim?: No
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. 8.1 pH was recorded. Adjusted to 7.2pH. Corrected during inspection.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537b Pool walls shall be maintained in good repair. Tiles are missing in an area near steps. Shown to CPO during inspection. No permit action.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept in good repair. Grout missing around skimmers and coping in areas. Shown to CPO during inspection. No permit action.
#22 · Premises: emergency telephone provided −6
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone.
Pool phone number posted was incorrect. CPO added correct phone number during inspection. Corrected and no permit action.
Apr 30, 2026 6 demerits · 1 violation
Inspector comments: Conducted inspection with CPO and property manager. Pool placed on A status and remains in good standing.
Property installed new AcuFlow flow meters. Submit updated PDSC for approval of new flow meters prior to May 31st 2026.
Pool heated but heater not currently operating.
Feature Flow meter: 100gpm
Permit Restriction: 1) Filtration Pump - Flow meter must remain operable. Flow required at 52 gpm to 63 gpm to meet turnover and flow restriction of the filter. 2) Feature A - Flow meter must remain operable not to exceed 119 gpm due to drain cover flow restriction. Suction Hazard. Fire pump tied to drains. Pump located on lower level. Patterson FP[1]C0178833-01350 hp pump.
Const. Date: 5/27/2009 Rope Length: 27' Night Swim?: No
#22 · Premises: emergency telephone provided −6
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone.
Dialing instructions missing. CPO added dialing instructions. Corrected and no permit action.
Jul 2, 2025 10 demerits · 3 violations
Inspector comments: Conducted inspection with CPO Stephen Gray. Pool returned to A status and may open.
Flow meters verified.
Feature pump flow meter: 98gpm
Rope length: 27’
Pool built: 05/27/2009
No night swimming
Pool has heater but heater currently turned off for the season.
Note: Katie R made a site visit to verify items on the in field plan review.
Permit Restriction: 1) Filtration Pump - Flow meter must remain operable. Flow required at 52 gpm to 63 gpm to meet turnover and flow restriction of the filter. 2) Feature A - Flow meter must remain operable, not to exceed 119 gpm due to drain cover flow restriction. Suction Hazard.
Fire pump tied to drains. Pump located on lower level. Patterson FP-C0178833-01,350 hp pump.
#22 · Premises: emergency telephone provided −6
.2530(f) Emergency phone shall remain operable. Emergency phone in wall not operational. Stuck on calling button. CPO installed other emergency phone in covered area by the bathrooms and replaced the signs to indicate emergency phone location. Corrected. No permit action.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. Some chemicals stored in pump room. Move to designated chemical storage room.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
.2526(h) Shower(s) shall be provided. Provided shower not connected to water.
Apr 22, 2025 2 demerits · 1 violation
Inspector comments: Inspection conducted with Ylmer. Pool remains in good standing and on A status. Ensure new main drain covers are installed before expiration in JUNE.
Pool has a heater but it is not currently on.
Main drain covers expire in JUNE of THIS YEAR 2025. Must replace with approved covers. Health department must receive an updated PDSC form to approve new covers.
Feature pump at 118gpm.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
.2526(h) Shower(s) shall be provided. Provided shower not connected to water.
Sep 18, 2024 16 demerits · 5 violations
Inspector comments: Conducted inspection with CPO Stephen Gray. Intent to suspend issued for flow meter and deck offsets. Call Devon Moeller when corrected 7049981122.
Feature pump at 112gpm
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Deceased bird in skimmer. Operator corrected. No permit action
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. Observed offsets greater than 1/2” by both skimmers. Intent to suspend item.
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Lounge chairs too close to pool. Operator moved and corrected.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Flow meter for main filtration system not operational. Intent to suspend item
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. Some chemicals stored in pump room. Move to designated chemical storage room.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
.2526(h) Shower(s) shall be provided. Provided shower not connected to water.
Apr 10, 2024 4 demerits · 1 violation
Inspector comments: Performed inspection with CPO Stephen Gray and Phil McRae. All items in compliance by end of inspection. EHS recommends lowering chlorine level for bather comfort.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Missing weekly recordings for cyanuric acid and total alkalinity early in the year. No permit action.
Aug 24, 2023 10 demerits · 2 violations
Inspector comments: Inspection conducted with Alfredo Lima. Permit suspended due to cyanuric acid levels significantly greater than 100ppm. Reduce levels and maintain at less than 100 ppm. Once corrected, call Hope McIntosh at 980-229-7549 to request a return visit. Pool must remain closed with signs indicating no swimming until permit is re-instated.
At that time, EHS will evaluate decking tile offsets. If offsets greater than 1/2” remain, a 30 day intent to suspend the permit may be issued.
Emergency Kings III system remains inoperable. Temporary phone installed, however, is cordless. Replace with phone that is fixed in place if Kings III will no be used going forward. EHS will evaluate emergency phone system upon return.
PDSC has been approved for both feature pump systems. Permit restriction requiring these systems to be turned off is lifted.
#2 · Water quality: disinfectant residual provided by −6
.2535 (4) The cyanuric acid level shall not exceed 100 parts per million. CYA in excess of 100 ppm. Records indicate multiple documented readings of 100ppm without corrective action noted. Reduce CYA and maintain at levels less than 100ppm. *permit item
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. Observed various offsets greater than 1/2” in decking pavers around pool perimeter. *permit item
Apr 25, 2023 14 demerits · 4 violations
Inspector comments: Inspection conducted with operator, Stephen Gray. Intent to suspend the permit issued due to inoperable flow meter. Current permit will expire on 4/30/2023. In order for permit to be renewed and pool to continue to operate beyond that date, flow meter must be repaired and verified by EHS.
PDSC for drain cover change out on feature pump system is not yet approved by the department. Feature pump system observed to be off during inspection. Operating permit will not be issued until PDSC has been approved and system evaluated by EHS.
Motor change for feature pump noted with same 2HP replacement. Operator noted that 3rd party electrician conducted install but they were not aware if permit pulled or finaled for project. Provide information on electrical permit finalization prior to permit issuance.
Communication between Caribbean Pools and this department indicated that impeller change may have taken place. This will need to be verified prior to permit issuance.
Nights swimming not approved.
Call Hope McIntosh at 980-229-7549 once items are all in compliance and pool is ready for re-visit.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Missing daily records on various weekends. Missing main drain checks on some days. No permit action.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. Observed various offsets in decking around pool perimeter. Operator filled gaps greater than 1/2”, however, significant shifting in deck tile work present.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Flow meter for main filtration system not operational. *permit item
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up. Observed gallons of liquid acid stored above other dry chemicals on storage room. Store chemicals to preven reaction.
Aug 24, 2022 32 demerits · 7 violations
Inspector comments: Inspection completed with Stephen Gray present.
Permit immediately suspended due to the following:
1. Chlorine at 0.0ppm.
2. The pH at 6.8.
3. Water with low visibility.
Correct the above items and contact Eli Freese at 704.621.2298 to reopen the pool. The following items will cause an intent to suspend to be issued if not corrected when pool is reopened:
1. Illegible flow meter, cannot read numbers as they have worn off.
2. Landscaping obstructing safety signs.
#1 · Water quality: water clear enough to clearly see bottom of pool and pool drain −6
.2535(2) Main drains must be clearly visible from the pool deck. Observed zero visibility of main drains due to large quantities of sodium bicarbonate being added to increase pH. Immediate suspension issued.
#2 · Water quality: disinfectant residual provided by −6
.2535(4) Maintain chlorine at least 1.0 ppm. Observed chlorine at 0.0 ppm. Permit suspended.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Observed pH at 6.8. Permit suspended.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed pool furniture within 6 feet of pool deck near emergency phone. CDI- rearranged.
#18 · Premises: lifeguards present or warning signs posted −4
.2530(c) All pool signage shall be visible upon entrance to the pool and permanently affixed. Observed signage obstructed by landscaping.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Observed numbers worn off of flow meter, could not obtain accurate reading for this reason. Replace flow meter.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(d) Pump room floor shall be kept dry and free of standing water. Observed leak in flow meter causing water to pool on pump room floor.
Mar 3, 2022 10 demerits · 3 violations
Inspector comments: Inspection completed with Alfredo Lima present. No signature due to COVID.
Intent to suspend permit issued for automatic chlorinator not turning off when circulation pump has no flow. Repair within 30 days or permit may be suspended.
Observed throw rope connected to ring buoy beginning to fray. Replace rope within 30 days.
Observed grounding wire disconnected from circulation pump. CDI- reaffixed.
#23 · Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 −4
.2535(6) Automatic chlorine and bromine feeder pumps shall be automatically prevented from operating when the circulation pump is not in operation. Observed automatic chlorinator not turning off when pump was not in operation. Intent to suspend permit issued. Repair within 30 days.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Observed stuck flow meter. CDI- repaired.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. Observed chemical barrels being stored in pump room.
Jul 28, 2021 12 demerits · 3 violations
Inspector comments: Inspection completed with Stephen Gray present. No signature due to COVID.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Observed pH at 7.0. CDI- adjusted to 7.2.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed pool floats obstructing walkway. CDI- floats were relocated.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(d) Pump room floor shall be kept dry and free of standing water. Observed water accumulation on pump room floor due to valve not fully closed. CDI- valve was closed properly.
Feb 17, 2021 24 demerits · 5 violations
Inspector comments: Immediate suspension issued for pool pH at 7.0 and emergency phone non-operational. Correct these items and call Eli Freese at 704.621.2298 to reopen pool.
Intent to suspend permit will be issued after immediate suspension is lifted if the following is not corrected: Record without main drain safety checks, more than 1/2" opening between gates and framing within 18 inches of gate handle.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Observed pool pH at 7.0. Immediate suspension issued.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Observed main drain safety checks not being recorded daily for the month of January 2021. Ensure main drains safety checked are performed and recorded daily.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Gate latches located at less than 54" shall require the use of key, combination lock or card reader or be located on the inside of the gate at least three inches below the top of the gate with no greater than 1/2" within 18" of latch mechanism. Observed gates at both entryways to pool deck with 3/4" gap between gate and frame. Correct or an intent to suspend will be issued once the immediate suspension is lifted.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed pool furniture within 4 feet of pool. Correct.
#22 · Premises: emergency telephone provided −6
.2530(f) Emergency phone shall remain operable. Observed emergency phone non-operational. Immediate suspension issued.
Aug 13, 2020 8 demerits · 2 violations
Inspector comments: Inspection completed with Alfredo Lima on site. No signature due to COVID-19.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed furniture within 5 feet of pool. CDI- furniture rearranged to provide 6 feet of walking space.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Observed flow meter non-operational.
Apr 9, 2020 8 demerits · 2 violations
Inspector comments: ITS issued for no spot in record book to record main drain checks.
No signature due to COVID-19.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Observed no area in record book to record main drain checks. Intent to suspend issued.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed patio furniture within 4 feet of pool. CDI- furniture relocated.
Dec 2, 2019 0 demerits · 0 violations
Inspector comments: Observed no non-complaint items.
General Comments:
Observed 2 pavers lower than others.
Verified new pump and PDSC information
Permit Restriction: Pump must be set at 2350 RPM
No violations were recorded for this inspection.
Jan 14, 2019 10 demerits · 3 violations
Inspector comments: Verified PDSC information.
Observed pool deck tiles offset. Correct deck tiles for next season.
Observed emergency phone speaker quiet. Service phone.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed one weir not floating on left side of pool.
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
Observed 2 returns on step and one return near light with no fittings.
Replace missing return fittings.
.2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair.
Intent to suspend.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Observed one mirror not shatterproof in men's restroom.
.2626(k) Provide shatterproof mirrors.
Sep 13, 2018 20 demerits · 4 violations
Inspector comments: Verified PDSC information.
Intent to suspend issued.
Facility has 30 days to install fittings and repair flow meter or the permit will be suspended.
Contact Chris Sells at 704 576 8678 with questions or when repairs are complete.
#3 · Water quality: pool water pH −6
Observed pH at 6.9 corrected to 7.4 during inspection.
.2535(1) Maintain pH at 7.2 to 7.8.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
Observed returns and autofill missing fittings.
.2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair.
Intent to suspend
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed ring buoy rope length over 27 feet. Corrected during inspection to 27 feet.
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed flow meter not functioning.
.2518(g) Keep flow meter operational.
Intent to suspend
Mar 15, 2018 12 demerits · 3 violations
Inspector comments: General comment: Address at emergency phone starting to peel. Emergency phone is also slightly staticy. Remedy these issues prior to next inspection.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed debris in skimmers. Keep skimmers free of debris.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed lounge chairs within 6 feet of pools edge. Maintain at least 6 feet of clearance at all points.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter stuck. Repair.
Nov 21, 2017 4 demerits · 1 violation
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed deck chairs within 6 feet of pools edge. Maintain 6 feet of clearance at all points.
May 25, 2017 20 demerits · 5 violations
Inspector comments: Intent to suspend issued for
#17 (offsets in deck pavers) & #23 .
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
-- Observed some deck lounge chairs and garbage container ~5' from pool edge. ** Maintain 6' of clear walking space.
-- Observed offsets up to at least 1" (+) between some deck pavers adjacent to raised planter bed (in area of grill/ opposite side from restrooms). ** Decks shall be maintained free of trip hazards or offsets > 1/2" resulting from deterioration. See .2537(b)(2)
INTENT TO SUSPEND.
#22 · Premises: emergency telephone provided −6
No phone number posted for the emergency phone/ push button phone box. ** Emergency phone number posted on the front of the emergency phone while EHS on-site.
#23 · Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 −4
Power was shut off to the pool filtration/ circulation pump and the automatic chlorine feeder pump continued to operate/run.
** See .2535(6) Automatic chlorine feeder pump shall be automatically prevented from operating when the circulation pump is not in operation.
INTENT TO SUSPEND.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter float stuck. ** Keep flow meter operational.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
-- Equipment room floor wet due to leak at filter multi-port valve and leak at filtration pump. ** Repair/ resolve. Keep equipment room dry.
-- Observed liquid chlorine drums stored in equipment room.
** All pool chemicals should be stored in chemical storage room. Existing pool chemical room is too small to accommodate storage of pool chemical drums.
See .2534 (2).
Dec 5, 2016 20 demerits · 6 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Missing one weir. Install functional weir.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Some deck chairs and trash can too close to pool. Maintain at least 6 feet clear walkway around the pool. Corrected by operator.
#23 · Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 −4
Automatic chlorine and acid feeder do not shut off when the pump shuts off. Provide automatic feeders that stop feeding chemicals when the filtration pump is off.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter stuck. Repair or replace.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Leak in pump room. Fix leak.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Mirror in restroom cracked. Provide intact, shatterproof mirrors for restrooms.
Jun 6, 2016 24 demerits · 7 violations
Inspector comments: Immediate suspension issued.
6)
Contact Will Harrison (704-507-6824) for reinspection once issues have been corrected,
#5 · Water quality: daily written records of water quality and test kit kept on site −4
No place for main drain checks on sheet, no checks for this month. Cyanuric acid checked monthly currently. Check daily Cl, pH, main drains and temperature when heater is on. Check at least weekly TA and CYA. - Intent to suspend item.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
Vacuum plug missing. Port shall be plugged when not in use. - Corrected by operator.
Bubbler pumps actually Pentair Whisperflo WFE-8, 2 HP pumps. Submit updated PDSC forms. - Immediate suspension item.
Main drains for bubblers not VGB approved for wall installation with no sump. Provide VGB approved covers and submit updated PDSC form. - Immediate suspension item.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Pool with 43 foot wide steps and only one handrail. Handrails should be placed no more than 10 feet apart.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Some chairs too close to pool edge. Provide at least 6 feet clear walkway around pool. - Corrected.
Some pavers wobble, have > 1/2" offset, or are broken. Maintain pavers secure, in good condition and with less than 1/2" offsets. Operator has pavers on order. - Intent to suspend item.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter stuck. Repair or replace.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
New liquid chemical feeder installed, no room in chemical storage room. Recommend storing away from equipment.
Very low flow for ventilation, grates mostly blocked. Clean fan and grates to allow for proper ventilation.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Mirror in men's restroom cracked at faucet. Recommend replacing with shatterproof mirror.
Sep 10, 2015 8 demerits · 3 violations
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
One handrail on steps >20 ft in length. Provide handrails every 10 ft or less on steps greater than 20 ft in length.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Lounge chairs 4 1/2 ft to pool edge. Maintain 6 ft clearance all the way around pool.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
No paper towels in men's restroom. Provide paper towels.
Mar 16, 2015 22 demerits · 7 violations
Inspector comments: 17 - General Comment: Some uneven pavers.
22 - General Comment - Provide additional signage for emergency phone. Not clearly visible. Verify on return.
Intent to Suspend issued for #5 and #16
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Acid not recorded in Februrary or March. Record weekly. Intent to Suspend issued.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
One wall return at drains missing fitting. Replace.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Gates not self-closing, self-latching. Repair. Intent to Suspend issued.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter stuck. Keep operable.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Pump room floor wet. Keep dry.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Sink in women's not operable. Repair. Mirror in men's cracked. Replace with shatterproof.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
Pool being filled by hose. Maintain air gap.
Oct 23, 2014 22 demerits · 5 violations
Inspector comments: 16. Observed fence gates to open in towards pools instead of out. Pool was constructed in May 2009. -G.C. Gates must always self close and self latch.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
Observed vacuum line to not have required plug. -C.D.I. Plug was provided. Observed Equalizer lines under skimmers to have solid plugs instead of compliant covers as required. Immediate suspension issued.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed 1 weir out of 2 missing. Replace missing weir.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed buoy rope not attached to ring buoy. Rope must be 27ft long and be attached to ring buoy. -C.D.I. Rope was attached.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed flow meter to be stuck. Repair flow meter..
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Observed Men's room water faucet at the sink not to be working. Repair it.
May 22, 2014 0 demerits · 0 violations
No violations were recorded for this inspection.
Oct 30, 2013 0 demerits · 0 violations
Inspector comments: #15 - NEW RING BUOY WILL BE NEEDED SOON
No violations were recorded for this inspection.
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “ASHTON SOUTH END” or State ID 2060530220). Inspection type (routine vs. follow-up) is not published in the county's data.