18demerits
HYATT HOUSE
435 E TRADE ST, Charlotte, NC 28202
Year-Round Swimming Pool · NC permit/State ID 2060530258
Latest result18 demerits
Last inspectedAug 4, 2026
Inspections on record27
On record sinceNov 13, 2013
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Nov 13, 2013Lower is betterAug 4, 2026
Inspections & violations
Aug 4, 2026 18 demerits · 5 violations
Inspector comments: 6 - Main drain covers discolored. Discoloration is usually a marker of deterioration of the cover. Recommend replacing the drain covers prior to expiration in 2027. A new PDSC form is required with drain cover replacement. If replaced, submit PDSC form to Health Department for approval.
19 - Pool rules signage indicates no animals. Rules require no pets. If signage changed, ensure no pets added to signage.
Intent to Suspend issued for:
.2524/.2537 - provide night lighting documentation - picture of pool at night with time stamp.
.2518 - provide spare pump basket for pump.
Eric present during the inspection.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Ring buoy tangled. Ensure ring buoy kept accessible at all times. Corrected during the inspection.
#21 · Premises: pool and deck lighting provided at pools that operate at night −4
Pool night swimming approval expires 2023. Provide photograph documentation with time stamp of sufficient lighting on pool deck for night swimming reapproval. Intent to Suspend issued. If choosing not to seek night swimming approval, signage must be changed to show pool closes at dusk.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter installed at angle. Install per mfg. instructions. No flow restrictions on pumping system. If a flow restriction ever required, flow meter must be installed per mfg. instructions at 90 degree angle.
No spare pump basket for pump. Provide. Intent to Suspend issued.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Planters/storage in pump room. Keep pump room clearly accessible.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Floors in restrooms slick with shoes on. Floors shall be slip-resistant.
May 4, 2026 20 demerits · 4 violations
Inspector comments: MAIN DRAIN COVERS WILL EXPIRE 4/8/2027. THEY MUST BE REPLACED AND A NEW PDSC FORM DOCUMENTING THE NEW COVERS MUST BE SUBMITTED AND APPROVED BY THE HEALTH DEPARTMENT PRIOR TO THAT DATE OR THE POOL WILL BE CLOSED UNTIL THAT IS DONE.
POOL HAD A NIGHT SWIMMING APPROVAL VERIFICATION ON 2/17/2023. C. ELMORE WILL VISIT AFTER DARK OR BEFORE DAWN TO DO THE 3 YEAR VERIFICATION VISIT. ENSURE THAT ALL OF THE LIGHTS FOR THE POOL AND DECK ARE STILL FUNCTIONAL.
#2 · Water quality: disinfectant residual provided by −6
.2535(4) Maintain chlorine at least 1.0 ppm. Observed chlorine to be at 0.1 PPM. Chlorinator seemed not to be functioning. Chlorine for normal operation must come through the chlorination system. Pool closed until this is corrected.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Observed pH to be at 6.8 upon arrival. It was corrected to 7.2 during the inspection.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
.2535 (11) The pool operator shall inspect the pool at least daily and maintain written records.
Observed gaps in the log book. Most records were properly kept. Keep all the records properly for every day the pool is open for swimming.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter appears to be stuck. No flow restrictions. Keep flow meter operable. No permit action taken.
Sep 9, 2025 22 demerits · 6 violations
Inspector comments: Intent to Suspend issued for .2524/.2537 - provide documentation showing sufficient lighting present for night swimming approval.
John Smith present during the inspection.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
One day missing from logs in September and also for August. Ensure daily record keeping for chlorine, pH and main drain checks.
No CPO onsite for inspection. Both not scheduled to work. If pool is open to the public, CPO shall be present. Recommend getting all staff CPO certified. Chemicals ok and pool CPO should be back onsite tomorrow.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Some algae build-up starting on steps. Monitor and treat as needed.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Large binder clip present on weir - rusted out. Removed during the inspection. Keep skimmers clean.
#21 · Premises: pool and deck lighting provided at pools that operate at night −4
Lights on timer switch. Provide documentation that lights are operable at night with sufficient lighting present for night swimming approval. Intent to Suspend issued. Photograph documentation ok.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter appears to be stuck. No flow restrictions. Keep flow meter operable.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Paper towel dispenser in men's restroom not operable. Keep fixtures in good repair.
Apr 15, 2025 20 demerits · 6 violations
Inspector comments: Johnny Fernandez present during the inspection.
Note: Old permit posted at pool. Either remove or replace with current permit for 2025 available on our website.
Intent to Suspend issued for the following:
.2535 - maintain weekly record keeping for CYA
.2521/.2537 - provide documentation showing sufficient lighting provided for night swimming approval
.2517/.2521 - repair handrail so secure
.2537 - replace rusted screw in light - keep fixtures in good repair
.2518 - repair flow meter so operable
A return visit will be made in 30 days to verify completion of ITS items.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Cyanuric acid not recorded weekly. Recording Calcium instead. Record cyanuric acid weekly. Intent to Suspend issued.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Step handrail loose. Repeat non-compliance. Handrail pulling out of ground and presents hazard. Tighten/secure handrail. Intent to Suspend issued.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
Screw rusted on pool light at deep end. Keep fixtures in good repair. Replace. Intent to Suspend issued.
#21 · Premises: pool and deck lighting provided at pools that operate at night −4
Lights not operable in pool. Not required for night swimming approval. For renewal, provide photograph documentation of night lighting showing sufficient lighting on pool deck. Pool hours are until 10:00 pm. Intent to Suspend issued.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter not operable. No flow reading when pump turned off. Repair flow meter. Intent to Suspend issued.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Shower not operable. Provide shower/keep operable.
Oct 15, 2024 16 demerits · 4 violations
Inspector comments: Dontae Johnson present during the inspection.
Note - State operating permit that is posted is expired. New operating permit is available on the Meckpools website.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
One day missing from log book, September 17th. Ensure daily record keeping for chlorine and pH.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Step handrail loose. Tighten.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
Rusted screw in one light. Replace screw. All fixtures/screws in pool should be stainless steel.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Ring buoy rope at 26 ft. Required at 24 ft. Corrected during the inspection.
Note: Grab rope degrading. Provide new USCG approved ring buoy rope by November 1st. Picture will suffice of buoy.
Mar 18, 2024 16 demerits · 5 violations
Inspector comments: 22- 911 has 435 Trade St. on file. Pool address is 435 E. Trade St. Correct address so that 911 has the correct address within 1 week or permit will be suspended.
Intent to Suspend issued for:
.2537 - affix light to wall to eliminate offset.
.2537 - provide night lighting documentation to show sufficient lighting present for night swimming approval.
Dontae Johnson present during the inspection.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Two days missing main drain checks in March and two days in February. Maintain daily record keeping for main drains.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
Pool light not secure to wall with gap and fitting loose. Repair light to wall. Intent to Suspend issued.
#21 · Premises: pool and deck lighting provided at pools that operate at night −4
Pool is approved for night swimming on permit. Provide night lighting documentation to renew night swimming approval. Pool hours until 10:00 pm. Intent to Suspend issued.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
One sink not operable in left restroom. Repair sink. Keep all sinks operable.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
No backflow prevention device on hose bib on shower. Provide backflow prevention device.
Sep 25, 2023 12 demerits · 3 violations
Inspector comments: Dontae Johnson present during the inspection.
Provide photographs of lights operable at night within 30 days for night swimming approval.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Main drain checks not recorded weekly. Record daily. Operator moved from hand written to digital for record keeping. New records do not have section for main drain check. Ensure checks are recorded daily if not on digital forms.
Some days where chlorine was 0 ppm with no corrective action items written in. Ensure corrective action recorded.
Note: CPO is required at least daily to monitor the pool. Not all staff is CPO certified.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Some etching on pool floor. Keep floor in good repair.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
No Diving on international no diving signage with paint covering. Corrected during the inspection.
Feb 16, 2023 20 demerits · 5 violations
Inspector comments: 21 - Night lighting expires 2023. New night lighting verification required. Photograph documentation will suffice. Pool has had ample lighting in past. Provide photograph documentation for new night swimming approval.
Immediate Suspension issued for chlorine. Once corrected to at least 1.0 ppm through the chlorinator, contact Katie to re-open the pool. Operator shocked pool while onsite without EHS knowledge. Pool shall remain closed at least one turnover before a return visit can be made.
#2 · Water quality: disinfectant residual provided by −6
Chlorine at 0.3 ppm. Maintain at least 1.0 ppm through the chlorinator. Immediate Suspension issued.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed step handrail loose at pool. Repeat item. Tighten and keep in good repair.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
Pool light not secure. Gap around bottom. Tighten and maintain secure. ITS items. Ensure openings no greater than 1/2".
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Main entry door sticking on carpet when opened fully. Ensure door self-closes, self-latches. Intent to Suspend item.
#23 · Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 −4
Flow meter for chlorinator installed on outlet line. Required per NSF approval on inlet line. Intent to Suspend item. Flow meter is new.
Oct 27, 2022 22 demerits · 7 violations
Inspector comments: 21 - Lights on timer switch. Provide night lighting photograph showing lights in pool operable along with exterior lighting visible for night swimming approval.
Dontae Johnson present during the inspection.
Intent to Suspend issued for the following:
.2535 - maintain daily record keeping for temperature of pool
.2518 - repair flow meter so operable
.2519 - Provide specifications showing NSF listing for filter or install NSF approved filter; no air relief valve, provide air relief valve; filter leaking at top multi-port, repair to ensure filter functioning correctly
.2513 - plumb air gap at backwash line to pit
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Pool heater on. Temperature not recorded daily. Maintain daily record keeping for temperature of pool. Intent to Suspend issued.
DPD-2 Reagent expired. Electronic test kit not operating. New test kit ordered to be delivered on 10/28. Replace expired reagent.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Some etching on pool floor. Monitor and repair as needed. Plaster is new.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Skimmer weir in upside down. Install weir to meet NSF approval.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Step handrail slightly loose. Tighten.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
New filter installed - Jacuzzi JSF26 rated for 70 gpm. Design flow of pump at 70 gpm. New filter only just approved with design flow of pump.
No NSF listing for filter. Could not find a spec sheet for filter showing that it is NSF approved. Not listed on NSF website. Provide spec sheet for filter showing NSF approval or replace with NSF approved filter. Intent to Suspend issued.
No air relief valve on filter. Install per rule requirement. Filters shall have air relief valves located at top of filter. Intent to Suspend issued
Leak at top of filter. Filter sounds to be sucking air. Repair leak. Intent to Suspend issued.
Flow meter stuck. Repair so operable. Intent to Suspend issued.
#27 · Equipment room: filter backwash discharged through an air gap −2
New plumbing run in pump room with replacement of heater and filter. No air gap at backwash line to pit. Did not view sight glass on filter. Provide air gap into backwash pit to ensure no cross connections and that backwash water can be viewed. Intent to Suspend issued.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
One sink in women's restroom not operable. Replace batter so that sinks remain operable.
Mar 29, 2022 18 demerits · 5 violations
Inspector comments: Note: Pool heater not operable at time of inspection. Replacement onsite but has not yet been installed. Ensure mechanical permit is pulled for new heater.
Grab rope on ring buoy starting to degrade. Replace ring buoy with USCG approved prior to May 1 operating permit.
Night lighting could not be verified. Lights are on a timer. Provide photograph documentation of pool with lighting so that all areas of pool and pool deck show sufficient lighting for night swimming approval. Provide prior to May 1 operating permit.
Dontae Johnson present during the inspection.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Etching and chipping plaster on pool floor. Facility is currently in process of getting pool re-plastered. New plaster, tile and wall tile to be replaced. Ensure pool plaster with light reflectance >50% and that when step tile replaced, ensure no greater than 1" from step edge and pool wall. Tile shall be at least 2x2 tile. Keep flooring in good repair as not to present a hazard to the public.
Some tiling missing from pool waterline tile. Replace where needed.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Some debris under skimmer basket on skimmer furthest from pump room. Ensure skimmers are kept clean. Clean under baskets.
Loose collar around lip of skimmer closest to pump room. Secure collar to meet NSF approval.
Weir installed on lower part of skimmer lip but upside down with Styrofoam facing up. Install skimmer weirs per mfg. instructions.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Damaged paver on pool deck. Offset not greater than 1/2"; however, monitor and repair/replace if worsens.
#23 · Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 −4
No flow meter on chlorinator. Original construction. If ever repaired/replaced, ensure flow meter installed on chlorinator inlet line.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Middle sink in women's restroom not operable. Battery appears dead. Keep sinks operable.
One soap dispenser broken in men's restroom. Repair/replace soap dispenser.
Jul 27, 2021 16 demerits · 5 violations
Inspector comments: 6 - Main drain covers discolored. Drain covers due to be replaced by April 2022. Replace drain covers by September 1, 2021. Per mfg. requirements, yellowing of drain covers requires replacement. Submit new pdsc form once drain covers are replaced. Recommend replacing equalizer line covers at same time as main drain covers. Both due April 2022.
23 - No flow meter on chlorinator. Install per NSF requirement. Original construction.
Dontae Johnson present during the inspection.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Missing one day of main drain checks. Record daily.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Etching and chipping plaster on pool floor. May require repair prior to permit issuance 2022 if continues to worsen. Keep flooring in good repair as not to present a hazard to the public.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Weirs in backwards. Install weirs in skimmers per mfg. specifications.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Step handrail loose. Tighten and keeping good repair. Repeat.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
One toilet in women's restroom without toilet paper. Provide toilet paper.
Mar 10, 2021 34 demerits · 8 violations
Inspector comments: 5 - Maintain daily record keeping. Pool has been closed to public. Assure, when open, chlorine, pH and main drain checks daily. Total
alkalinity and cyanuric acid weekly.
23 - No flow meter installed on chlorinator. Install per mfg. instructions. Original installation.
Immediate Suspension issued for chlorine, pH and emergency telephone. Once corrected, contact Katie Rudisill at 704-309-5494 to
schedule a return visit to open the swimming pool.
Dontae Johnson present during the inspection. No signature due to covid restrictions.
Note - heater not operable at time of inspection. No heat.
#2 · Water quality: disinfectant residual provided by −6
Pool chlorine at 0 ppm. Maintain at least 1.0 ppm through chlorinator. Immediate Suspension issued.
#3 · Water quality: pool water pH −6
Pool pH at 8.0. Maintain at 7.2 to 7.8. Immediate Suspension issued.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Some chipping/damage to pool plaster in several locations. Does not appear to present cut hazard at time of inspection. Continue to
monitor and repair as needed.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Step handrail loose. Keep in good repair. Tighten.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Main door entry sticking on carpet and does not self-close when fully opened. Repair door to self-close, self-latch.
#21 · Premises: pool and deck lighting provided at pools that operate at night −4
Did not verify lighting for night swimming approval. Either schedule return visit or provide documentation of lights operable so that
sufficient lighting is present.
#22 · Premises: emergency telephone provided −6
Emergency phone not operable. Connecting to dispatch service. Incorrect phone number and address listed at phone. Given California address. Phone shall have correct phone number and address for swimming pool. When phone number called, shall ring the emergency phone. 911 shall have correct address. Immediate Suspension issued.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
One sink in men's restroom not operable. Repair battery so sink is operable.
Aug 24, 2020 22 demerits · 6 violations
Inspector comments: Intent to Suspend issued for CPO, light verification, and operational skimmer weirs.
Matt Allen present during the inspection. No signature due to covid restrictions.
Note: Emergency telephone rings back to automated service at front desk. Automated service gives option of front desk. Per management, front desk is always staffed and phone will always be answered.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
CPO not present at time of inspection. Spoke with management that pool operator must visit property at least daily. Ensure that pool operator is present at least daily. Intent to Suspend issued.
.2535 (11) The pool operator shall inspect the pool at least daily and maintain written records.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed etching on pool floor in three locations where plaster is beginning to wear. Continue to monitor and repair as needed.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Skimmer weirs stuck forward. Repair skimmer weirs so they remain operational. Intent to Suspend issued.
#21 · Premises: pool and deck lighting provided at pools that operate at night −4
Pool approved for night swimming. Lighting could not be verified as operational. All lights shall remain operational for night swimming approval. Intent to Suspend issued.
#23 · Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 −4
Small leak on chlorinator. Repair leak.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
One stall missing toilet paper in men's restroom. Provide toilet paper in restrooms.
Mar 9, 2020 20 demerits · 5 violations
Inspector comments: 22 - General Comment - Emergency phone number calls back the front desk to an automated answering service. 911 must be capable of calling back line to reach caller/or front desk if manned 24 hours per day. Given 30 days to repair. Permit will be suspended if not corrected within 30 day timeframe.
Intent to Suspend issued for flow meter.
Per operator, like for like change on pump. Permit had been pulled and passed inspection. E3656761.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Some damage to pool floor. Does not appear to present hazard. Some etching on plaster. Keep pool floor in good repair.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Weirs stuck in place/backwards. Corrected to function properly during inspection.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Handrail at steps loose. Keep in good repair. Tighten so as not to present a hazard.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Ring buoy rope at 26 ft. Corrected to 24 ft. (required) during inspection.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter stuck. Keep operational. Intent to Suspend issued.
Jul 17, 2019 26 demerits · 7 violations
Inspector comments: 15 - Some damage to ring buoy under becket. Operator ordered new USCG approved ring buoy during the inspection. Replace within 30 days.
Note: Could not verify mirrors as shatterproof in restrooms. Not marked. Verify as shatterproof mirrors.
Immediate Suspension issued for chlorine. Once corrected, contact Katie at 704-309-5494 to schedule a return visit.
#2 · Water quality: disinfectant residual provided by −6
Chlorine at 0.2 ppm. Operator turned up chlorinator at beginning of inspection but no change in chlorine level. Maintain at least 1.0 ppm through chlorinator. Immediate Suspension issued.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Some days with chlorine levels below 1.0 ppm. No corrective actions. Provide corrective actions on log books.
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Water level high in pool. Maintain water level so skimmers can operate per manufacturer instructions. .2518
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Step handrail loose. Keep in good repair.
.2521 Install ladders per manufacturer instructions.
#21 · Premises: pool and deck lighting provided at pools that operate at night −4
Lights not operational in swimming pool. Permit issued for night swimming with no night visit. Provide photograph documentation of sufficient lighting with no pool lights operational.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter not operational. Repair by next inspection.
.2518(g) Keep flow meter operational.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Muriatic acid stored above dry chemicals in chemical storage room. Corrected during inspection.
.2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up.
Mar 28, 2019 2 demerits · 1 violation
Inspector comments: 3) .2535(1) Maintain pH at 7.2 to 7.8. Upon arrival, pH was 6.8. CPO corrected pH to 7.4 by end of inspection.
5) .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Observed missing records for some days in previous months. Ensure daily records are kept. Records beginning March 1st were complete.
Observed all pool deck lighting working at time of visit. CPO stated that the lighting has not changed since this visit. Based on Katie Wilson's visit on 9/26/2018, night swimming is approved.
KW: "Onsite visit to pool to verify lighting for night swimming prior to dawn. Pool is open to public after dusk. At time of visit, sufficient lighting is provided. Pool illumination is sufficient to illuminate the main drains of the pool and the deck area of the pool so that it is visible at all times the pool is in use. Lighting fixtures are of such number and design to illuminate all parts of the pool, including the water, depth markers, signs, entrances, restrooms, safety equipment, and the required deck area and walkways. The illumination is sufficient so that the floor of the pool can be seen at all times the pool is in use. At time of visit, Night Swimming is approved. The pool is in compliance and permitted for Night Swimming." Night swimming is approved.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
.2626(h) Shower(s) shall be provided. Observed water to shower was cut off. During inspection, CPO was able to get shower working.
Sep 25, 2018 22 demerits · 5 violations
Inspector comments: Intent to Suspend issued for record keeping, return wall fittings, lights (lighting) and flow meter. A return visit will be made to verify adequate pool lighting.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Records not maintained as required. Ensure main drain checks (VGB), temperature, chlorine and pH are recorded daily. Cyanuric acid and total alkalinity required weekly. Intent to Suspend issued.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
One return missing fitting on wall and one eyeball backwards. Keep all fittings in good repair and in place to ensure adequate circulation. Intent to Suspend issued.
#21 · Premises: pool and deck lighting provided at pools that operate at night −4
Pool lights not operational. Per operator, lights are not needed in pool. Adequate lighting is provided for night swimming and to see pool drains, etc. Will verify with night visit. Lights may be required operational for night swimming. Intent to Suspend issued.
#22 · Premises: emergency telephone provided −6
Emergency phone not operable. Corrected during inspection.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter stuck. Keep operational. Intent to Suspend issued.
Apr 25, 2018 0 demerits · 0 violations
No violations were recorded for this inspection.
Dec 13, 2017 12 demerits · 2 violations
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed throw rope at 22 feet. Adjusted to 24ft onsite.
#22 · Premises: emergency telephone provided −6
Emergency phone did not connect to 911 due to connection issue. Repair emergency phone so that it connects to 911 on first try. Corrected onsite.
Apr 4, 2017 4 demerits · 1 violation
Inspector comments: 6 - General Comment - 6HPxxx covers installed on 2 skimmers. Pool has Hayward SP3210EE rated at 132 gpm. Equalizer line covers per PDSC form rated at 122 gpm. Covers must be able to handle max flow of the pump. Replace covers within 30 day time frame. Submit updated PDSC form with changes once corrected for approval to Katie Wilson.
29 - General Comment - Shower winterized and not operable.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
One inlet missing fitting and one eyeball backwards. Repair and replace.
Oct 11, 2016 10 demerits · 2 violations
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Rope for ring buoy damaged and at 22 ft. Corrected and replaced to 24 ft rope during inspection.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Deck paver not level by ladder. Corrected during inspection.
Jan 14, 2016 12 demerits · 3 violations
Inspector comments: Inspection completed by Iesha Speaks
#2 · Water quality: disinfectant residual provided by −6
Chlorine measured <1.0 ppm. Chlorine is now a 1.5 ppm. Keep chlorine at 1.0 ppm.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
CYA observed not recorded at least weekly.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Handrail for the pool observed loose. Handrail was tightened during inspection.
Sep 23, 2015 6 demerits · 2 violations
Inspector comments: Note: Lights were not verified during this inspection. Note: Pool Rules signage states no animals on deck. If replaced in the future, advise to reword to no pets.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Water level high in pool where skimmers could not work properly. Lower water level in pool so skimmers operating properly. Operator started to backwash during the inspection.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Step handrail slightly loose. Keep in good repair. Tightened during inspection.
Mar 12, 2015 6 demerits · 2 violations
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Damage to deck at shower. Keep in good repair.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
No paper towels in men's. Provide paper towels.
Oct 6, 2014 8 demerits · 3 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Some algea on skimmer. Keep clean. Corrected during inspection.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Step handrail loose. Corrected during inspection.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Showerhead leaking. Keep in good repair.
Jan 15, 2014 10 demerits · 2 violations
Inspector comments: 22 - General Comment: Observed no dialing instructions posted. Corrected during inspection.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed ring buoy not USCG approved. Corrected during inspection.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed pool chair 4 ft to pool. Maintain 6 ft clearance.
Nov 13, 2013 0 demerits · 0 violations
No violations were recorded for this inspection.
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “HYATT HOUSE” or State ID 2060530258). Inspection type (routine vs. follow-up) is not published in the county's data.