22demerits
AURORA FLATS
1427 EASTCREST DRIVE, Charlotte, NC 28205
Year-Round Swimming Pool · NC permit/State ID 2060530305
Latest result22 demerits
Last inspectedJul 8, 2026
Inspections on record20
On record sinceMay 21, 2015
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
May 21, 2015Lower is betterJul 8, 2026
Inspections & violations
Jul 8, 2026 22 demerits · 6 violations
Inspector comments: Inspection completed with Keith Howard present.
Pool permit suspended for the chlorine at 0ppm. Maintain chlorine at 1.0ppm or above. Once corrected, contact Eli Freese at 704.621.2298 to verify and reopen pool. Maintain pool closed in interim.
An 30 day intent to suspend will be issued on the permit for the items listed below if they have not been corrected once the pool is reopened.
1. 5 missing weirs in skimmers.
2. Debris on pool floor and walls.
3. Missing depth tile near pump room on pool wall.
#2 · Water quality: disinfectant residual provided by −6
.2535(4) Maintain chlorine at least 1.0 ppm through NSF approved chlorinator. Observed chlorine at 0ppm. Checked again after approximately 1.5 hours and chlorine still at 0ppm. Permit suspension issued.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed decorative tile underneath pool coping missing near one ladder. Replace.
.2537(14) Keep pool surface and pool floor free of debris. Observed debris that appeared to be biological growth on pool floor and wall.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. Observed 5 missing weirs out of 7 total. Replace.
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed multiple skimmer baskets full with debris. CDI- cleaned.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
.2523(b) Provide depth markers spaced not to exceed 25 feet when measured along the perimeter of the pool. Observed one missing depth marker near pump room.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed one ladder missing 2 steps. Repair.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(m) Keep restrooms and fixtures clean and in good repair. Observed urinal in men’s restroom non operational. Repair.
May 18, 2026 22 demerits · 5 violations
Inspector comments: MAIN DRAIN COVERS AND EQUALIZER LINES EXPIRE 4/29/2029.
POOL IS NOT APPROVED FOR NIGHT SWIMMING.
CONTACT C. ELMORE WHEN CORRECTIONS ARE MADE. (704-507-6814) POOL IS CLOSED TO SWIMMING BY ORDER OF THE HEALTH DEPARTMENT.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed the pool floor, ladders, and walls to have green and black discolorations that indicate biological growth. Keep the pool interior clean.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. Observed 1 weir missing, replace the weir.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
.2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. Observed missing eyeball fitting on a return.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Lifesaving equipment includes body hook and pole and USCG approved ring buoy with required rope length. Observed 1 damaged ring buoy in place on the deck. Item was traded out for a correct buoy. Ropes on both buoys were corrected to 50 foot length, as required. -CDI.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed filter system to be stuck in a backwash mode. The pump cannot run without draining water through the backwash. This must be corrected in order for the pool to be open for swimming. Immediate Suspension issued.
Nov 5, 2025 30 demerits · 7 violations
Inspector comments: INSPECTION WITH HUNTER DELAO OF MCHD PRESENT.
POOL IS CLOSED BY ORDER OF THE HEALTH DEPARTMENT. KEEP POOL CLOSED SIGNS POSTED AT BOTH GATES AT ALL TIMES UNTIL THE POOL IS REOPENED BY THE HEALTH DEPARTMENT. CORRECTIONS MUST BE VERIFIED BY THE HEALTH DEPARTMENT BEFORE THE POOL CAN BE REOPENED.
OBSERVED GLASS SHARDS ON THE POOL DECK. THEY WERE REMOVED. KEEP GLASS OFF OF THE POOL DECK.
OBSERVED THE POOL RULES SIGNS TO BE FADED TO THE POINT THEY ARE BECOMING DIFFICULT TO READ. REPLACE THEM WITH PROPER NORTH CAROLINA POOL RULES SIGNS THAT HAVE THE CORRECT WARNING STATEMENTS AND LETTER HEIGHTS.
OBSERVED CHLORINE PUCKS ON THE POOL FLOOR. POOL HAS ALSO BEEN SHOCKED WITH CHLORINE. THE POOL CANNOT BE OPEN WHEN SHOCK OR OTHER DISINFECTANT HAS BEEN PUT DIRECTLY INTO THE POOL, IT MUST BE CLOSED WITH POOL CLOSED SIGNS POSTED. A POOL MUST HAVE CHLORINE INTRODUCED THROUGH THE CHLORINE SYSTEM WHEN IT IS OPEN FOR SWIMMING.
POOL IS NOT APPROVED FOR NIGHT SWIMMING. A SIGN AT THE POOL INDICATES THAT THE POOL IS OPEN UNITL 8PM. SUNSET IN CHARLOTTE, NC ON THIS DATE IS 5:24PM. THIS POOL CANNOT BE OPEN AFTER SUNSET OR BEFORE SUNRISE. THE SIGNAGE MUST BE CHANGED TO REFLECT THIS OR THE POOL MUST BE APPROVED FOR NIGHT SWIMMING BY THE HEALTH DEPARTMENT.
MAIN DRAINS AND EQUALIZER LINE COVERS EXPIRE 4/19/2029.
CONTACT C. ELMORE WHEN CORRECTIONS ARE MADE. 704-507-6814
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Observed pool pH to be 8.0. This is out of the proper range. Immediate Suspension issued.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
pH, chlorine, and main drains must be checked once a day when the pool is open. Total Alkalinity and Cyanuric Acid (if in use) must be checked once a week, 100ppm maximum. Observed some gaps in pool records. Staff was advised of gaps and requirements.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs.
.2518(k) Replace missing or damaged skimmer baskets.
Observed 5 weirs out of 7 skimmers missing. Observed multiple damage skimmer baskets. Replace these items.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
.2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. Observed missing eyeball fitting on a return.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide USCG approved ring buoy. Observed ring buoys damaged to the point of being unacceptable for use. Observed throw ropes badly tangled. Provide USCG approved ring buoys in good repair with proper 1/4 inch throw ropes that are exactly 50 feet long from the point of attachment. This pool requires 50 foot ropes for the ring buoy. This pool requires 2 ring buoys due to the size of the pool.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing, self-latching. Observed gate not self-closing and self-latching. Gate is sticking on the sidewalk. Correct the gate to function properly.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(m) Keep restrooms and fixtures clean and in good repair.
.2526(f) At least one sink, one toilet, one urinal is required for men's restroom.
Observed restrooms badly soiled and in disrepair to the point of being unusable. Clean them and repair damage fixtures, such as the urinal in the men’s restroom.
May 20, 2025 6 demerits · 1 violation
Inspector comments: POOL HAS PASSED INSPECTION AND BEEN ISSUED PERMIT DECAL. POST PERMIT DECAL AND PAPER POOL PERMIT DOCUMENT AT THE POOL. THE PAPER PERMIT SHOULD BE AVAILABLE WITHIN 1-3 BUSINESS DAYS ON THE HEALTH DEPARTMENT POOL WEBSITE.
ENSURE THE POOL BATHROOMS ARE KEPT CLEAN AND PROPERLY FUNCTIONAL. ENSURE THEY ARE KEPT STOCKED WITH SOAP, PAPER TOWELS, AND TOILET PAPER.
OBSERVED POOL PUMP MOTOR TO BE SWAPED FOR A 5.5 HP MOTOR. ELECTRICAL PERMIT COM-ELC-25-000106 WITH A PASSING INSPECTION ON 3/13/2025.
#22 · Premises: emergency telephone provided −6
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone.
Observed pool phone sign to have incorrect number and incorrect address. Correct number and address were determined (447-497-7952, 1427 Eastcrest Dr. Charlotte) and sign was corrected. -CDI
Oct 3, 2024 22 demerits · 5 violations
Inspector comments: Immediate Suspension Issued. Pool is closed by order of the Health Department. Contact C. Elmore at 704-507-6814 when the corrections are made. Pool cannot reopen prior to verification of corrections by the Health Department.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed pool to have a large amount of debris in it.
.2537(14) Keep pool surface and pool floor free of debris.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs.
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.
Observed 6 out of 7 skimmers missing the weirs. Replace all missing weirs.
Observed some skimmer baskets to be filled with debris. Keep the baskets clean.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
.2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair.
Observed 2 missing eyeball return fittings. Replace the missing fittings.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(b) Two units of lifesaving equipment (or two lifeguards) must be provided for pools that exceed 3,000 sq. ft. surface area.
.2530(a) Provide at least 12 ft. long pole with body hook securely attached.
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less.
This pool requires 2 proper ring buoys with proper throw ropes and 2 body hook poles. Observed only 1 body hook pole out on deck and no ring buoys with throw ropes out on the deck. Throw ropes for this pool shall be exactly 50 foot in length.
Provide the proper lifesaving equipment where it is accessible and visible on the pool deck.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed gate latch to be broken and get his being held shut with a chain and lock. The lock was unsecured upon arrival such and access to the pool through the gate was simply a matter of pulling the chain through. This is a hazard risk for drowning as the pool is not properly secured against entry by children. The gate must be properly repaired. Prior to the repair the gate must be properly secured closed with a chain and lock that is kept locked at all times.
May 2, 2024 6 demerits · 1 violation
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
.2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance.
Observed drain covers changed out. 7 Aquastar 6HPHA EQ covers and 2 Aquastar 1216 main drain covers were observed. Pump is a Hayward HCP30501 with a 5 HP motor. PDSC form for the changes has not been submitted and approved by the Health Department. Pool cannot pass inspection without this approval. Pool shall remain closed until this is verified by C. Elmore.
Oct 10, 2023 16 demerits · 4 violations
Inspector comments: POOL IS CLOSED BY ORDER OF THE HEALTH DEPARTMENT. BOTH RING BUOYS MUST BE CORRECTED. CONTACT C. ELMORE AT 704-507-6814 WHEN CORRECTION IS MADE. POOL MUST BE CHECKED AND VERIFIED BY THE HEALTH DEPARTMENT BEFORE BEING REOPENED.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
pH, chlorine, and main drains must be checked once a day when the pool is open. Total Alkalinity and Cyanuric Acid (if in use) must be checked once a week, 100ppm maximum. Observed some gaps in pool records. Staff was advised of gaps and requirements. No Permit Action taken.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed 6 skimmer weirs missing out of 7 skimmers total. Replace the missing weirs.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed 1 ladder missing 1 rubber bumper foot. Replace the rubber bumper foot.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide USCG approved ring buoy. A rescue tube with lifeguard may be substituted for ring buoy.
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less.
Observed both ring buoys to be vandalized and to have had the throw ropes removed and cut up. Replace with proper ropes at 50 foot length that are at least 1/4 inch thick. POOL CLOSED PERMIT SUSPENDED
May 10, 2023 12 demerits · 3 violations
Inspector comments: POOL HAS PASSED INSPECTION AND BEEN ISSUED THE PERMIT DECAL. PAPER PERMIT WILL BE AVAILABLE ON-LINE AT THE HEALTH DEPARTMENT WEBSITE. DISPLAY THE PERMIT AND DECAL AT THE POOL DECK AREA.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. Observed 3 weirs missing out of 7 total. No permit action, at least 50% of weirs in place.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed one ladder missing one rubber foot. Please replace rubber foot.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed throw ropes on buoys to be longer than the required 50 feet. Ropes were corrected to the required 50 feet. -C.D.I.
May 20, 2022 8 demerits · 3 violations
Inspector comments: POOL HAS PASSED INSPECTION AND BEEN ISSUED THE PERMIT DECAL. PAPER PERMIT WILL BE AVAILABLE ON-LINE AT THE HEALTH DEPARTMENT WEBSITE. DISPLAY THE PERMIT AND DECAL AT THE POOL DECK AREA.
OBSERVED BROKEN GLASS AT THE POOL DECK. GLASS WAS CLEANED UP BY THE STAFF. ENSURE THERE IS NO GLASS IN THE POOL OR ON THE DECK BEFORE ALLOWING PEOPLE INTO THE POOL AREA.
ENSURE THE LOG BOOK IS PROPERLY KEPT WITH CHLORINE, pH, AND MAIN DRAINS RECORDED EVERY DAY THE POOL IS OPEN AND TOTAL ALKALINITY AND CYANURIC ACID CHECKED AT LEAST ONCE A WEEK. CYANURIC ACID CANNOT BE HIGHER THAN 100PPM IN THE POOL.
THE POOL SIGNS HAVE HOURS 10AM TO 9PM. POOL IS NOT APPROVED FOR NIGHT SWIMMING. POOL CANNOT BE OPEN AFTER SUNSET OR BEFORE SUNRISE UNLESS IT PASSES A NIGHT SWIMMING EVALUATION WITH THE HEALTH DEPARTMENT. IF YOU WISH TO HAVE THE POOL EVALUATED FOR NIGHT SWIMMING, PLEASE CONTACT C. ELMORE AT 704-507-6814.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed 1 weir missing out of 7. Replace weir. No permit action taken.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed 1 ladder missing 1 rubber bumper foot. Replace the rubber bumper foot.
#27 · Equipment room: filter backwash discharged through an air gap −2
Observed no air gap at the backwash line.
Oct 12, 2021 16 demerits · 5 violations
Inspector comments: POOL IS CLOSED BY ORDER OF THE HEALTH DEPARTMENT. CONTACT C. ELMORE WHEN CORRECTIONS ARE MADE. 704-507-6814. POOL CANNOT REOPEN UNTIL HEALTH DEPARTMENT VERIFIES ALL CLOSURE ITEMS CORRECTED.
pH, chlorine, and main drains must be checked once a day and recorded every day the pool is open. Total Alkalinity and Cyanuric Acid (if Cyanuric Acid is in use) must be checked once a week, 100ppm maximum for Cyanuric Acid. Keep proper records for all daily and weekly requirements.
STAFF AGREED TO EMAIL COPY OF REPORT
NO SIGNATURE DUE TO COVID-19 PRECAUTIONS.
CONTINUE TO FOLLOW ALL RELEVANT COVID RULES
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Observed water to have a pH of 8.0 upon arrival. Correction was attempted but brought the pH to 7.0. pH must be 7.2-7.8 for safety. IS Issued.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed 7 total skimmers with 1 skimmer missing the weir. Replace the weir.
#10 · Pool maintenance: safety ropes with floats and contrasting color bands provided at shallow area breakpoints −2
.2523(e) Provide a minimum of 3/4 inch diameter safety rope at the breakpoint.
.2523(e) Safety rope shall be marked with colored floats, 5 ft. apart or less.
Observed safety rope and floats to be missing. Replace the rope and floats.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed ladder missing one rubber foot. Replace the foot.
#27 · Equipment room: filter backwash discharged through an air gap −2
Observed no air gap at the backwash line.
May 26, 2021 12 demerits · 4 violations
Inspector comments: OBSERVED CALL BOX TO FUNCTION ON CALL OUT, BUT CALL BACK NUMBER WAS NOT FOUND TO FUNCTION. THIS MUST BE CORRECTED OR IT WILL BE CONSIDERED A VIOLATION. C. ELMORE WILL FOLLOW-UP ON THIS ITEM ON OR AROUND 6/10/2021.
CONTINUE TO FOLLOW ALL RELEVANT COVID RULES
POOL HAS PASSED INSPECTION AND BEEN ISSUED THEIR PERMIT STICKER.
PAPER PERMIT WILL BE AVAILABLE ON-LINE FOR DOWNLOAD AND PRINTING AT OUR POOLS WEBSITE.
POST PERMIT AND STICKER WERE VISIBLE AT POOL AREA.
CPO AGREED TO EMAIL COPY OF REPORT
NO SIGNATURE DUE TO COVID-19 PRECAUTIONS.
C. ELMORE VERIFIED THE FOLLOWING ITEMS
PUMP IS HAYWARD HCP30501 NOT HCP30503. CPO AMENDED PDSC FORM DURING THE INSPECTION.
PIPING IS 4 INCHES AS REPORTED
THE 2 MAIN DRAIN COVERS ARE AQUASTAR 1216
THE 7 EQ COVERS ARE AQUASTAR 6HPHA101
THE 3 FILTERS ARE PENTAIR TR140C
THERE ARE 19 RETURNS, NOT 14 AND THERE ARE 7 SKIMMERS, AS REPORTED.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. Observed 2 weirs missing out of 7 weirs. Replace the weirs.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions. Observed ladders missing the rubber bumper feet. Staff replaced bumper feet on ladders, but had to leave 1 foot without bumper foot as they ran out of bumper feet.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
.2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair.
Observed two missing return eyeball fittings out of 19. Replace missing fittings. Most eyeball fittings in place.
#27 · Equipment room: filter backwash discharged through an air gap −2
Observed no air gap at backwash line.
Sep 22, 2020 16 demerits · 5 violations
Inspector comments: “issuance of a permit by this department does not negate closure required by Executive Order No. 120, 138, 141, 147, or subsequent Orders in effect unless such Orders are rescinded or superseded by another applicable Order.”
NO SIGNATURE WAS OBTAINED DUE TO COVID-19 SOCIAL DISTANCING
POOL IS NOT APPROVED FOR NIGHT SWIMMING. IF NIGHT SWIMMING IS DESIRED, A NIGHT SWIMMING EVALUATION MUST BE PERFORMED. CONTACT C. ELMORE AT 704-507-6814 FOR THIS EVALUATION IF NIGHT SWIMMING IS DESIRED.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
pH, chlorine, and main drains must be checked once a day when the pool is open. Total Alkalinity and Cyanuric Acid (if in use) must be checked once a week, 100ppm maximum. Observed some gaps in pool records. Staff was advised of gaps and requirements. No Permit Action taken.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed 2 skimmer weirs missing out of 7 skimmers total. Replace the missing weirs. No Permit Action taken.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed ladders to be missing the rubber foot bumpers. Replace the bumpers.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
Observed two missing return eyeball fittings. Replace missing fittings. Most eyeball fittings in place. No Permit Action taken.
#27 · Equipment room: filter backwash discharged through an air gap −2
Observed no air gap at the back wash line.
Jun 29, 2020 8 demerits · 3 violations
Inspector comments: POOL WAS FOUND TO HAVE SEVERAL CLEAR GLASS BOTTLES BROKEN ON THE DECK AND RESULTING IN BROKEN SHARDS OF GLASS IN ON THE DECK AND IN THE POOL. CPO AND STAFF VACUUMED THE POOL INTERIOR AND SWEPT THE DECK TO REMOVE THE GLASS. CPO AND STAFF CERTIFIED TO C. ELMORE THAT ALL GLASS HAD BEEN REMOVED. C. ELMORE EVALUATED DECK AND POOL INTERIOR AND WAS UNABLE TO FIND ANY GLASS REMAINING. CPO, MANAGEMENT, AND STAFF WERE ADVISED THAT IT WAS THEIR RESPOSIBILITY TO ENSURE THE REMOVAL OF THE GLASS AND TAKE WHATEVER STEPS WERE NEEDED TO ENSURE SAFETY, UP TO AND INCLUDING DRAINING THE POOL. CPO AND STAFF REPEATED THEIR STATEMENT THAT ALL GLASS HAD BEEN REMOVED. C. ELMORE DID NOT FIND ANY EVIDENCE AT THIS TIME TO DISPUTE THE CLAIM.
POOL HAS PASSED INSPECTION.
PAPER PERMIT WILL BE AVAILABLE ON-LINE SO THAT IT CAN BE PRINTED OUT BY THE FACILITY MANAGEMENT. IT MUST BE PRINTED OUT AND POSTED WHERE IT IS VISIBLE FROM THE POOL DECK AREA.
STICKER ISSUED. POOL IS NOT APPROVED FOR NIGHT SWIMMING. IF NIGHT SWIMMING IS DESIRED, A NIGHT SWIMMING EVALUATION MUST BE PERFORMED. CONTACT C. ELMORE AT 704-507-6814 FOR THIS EVALUATION IF NIGHT SWIMMING IS DESIRED.
"issuance of a permit by this department does not negate closure required by Executive Order No. 120, 138, 141 or subsequent Orders in effect unless such Orders are rescinded or superseded by another applicable Order.”
NO SIGNATURE WAS OBTAINED DUE TO COVID-19 SOCIAL DISTANCING
POOL HAS AQUASTAR 6HP EQ LINE COVERS. AQUASTAR HAS CHANGED THE CERTIFIED FLOW RATE FOR THESE COVERS TO 92GPM. THESE COVERS EXPIRE JUNE 2021. WHEN THE CURRENT COVERS EXPIRE, NEW COVERS MUST BE RATED FOR THE REQUIRED FLOW RATE OF THE CIRCULATION SYSTEM.
POOL HAS AQUASTAR 1216101 MAIN DRAIN COVERS. THEY WILL EXPIRE JUNE 2021. BEFORE THE MAIN DRAINS AND THE EQ COVERS EXPIRE, THEY MUST BE REPLACED WITH PROPER COVERS AND A NEW PDSC FORM MUST BE SUMMITTED TO THE HEALTH DEPARTMENT AND APPROVED.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed 1 weir missing out of a total of 7 skimmers. The other 6 weirs were in place. No permit action taken.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed 1 ladder missing 1 rubber foot bumper. Replace the foot bumper.
#27 · Equipment room: filter backwash discharged through an air gap −2
Observed backwash line not to have an air gap.
Sep 23, 2019 6 demerits · 2 violations
Inspector comments: Verified PDSC information.
#10 · Pool maintenance: safety ropes with floats and contrasting color bands provided at shallow area breakpoints −2
Observed slack in safety rope.
.2523(e) Maintain breakpoint rope and floats in good repair.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
Observed one return fitting missing and one return fitting missing eyeball.
.2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair.
May 22, 2019 14 demerits · 4 violations
Inspector comments: Intent to suspend issued for gate from grill area to pool deck.
Call Chris Sells when repairs are complete at 704 576 8678.
Pool will be closed in 30 days if the gate repairs are not completed.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
Observed one missing return fitting. Corrected during inspection.
.2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed new gate installed on fence for grill area that leads off of pool dec. Gate locked at time of inspection.
Newly installed gate provides access from outside pool deck to pool deck. Gate previously not regulated that leads from grill area to pool deck is now considered enterence to pool deck and does not meet requirements. Gate from grill area to pool deck has latch below 54" and swings toward the pool.
.2528(a) Gate latches shall be 54" in height.
.2528(b) Gates may only swing toward pool if built prior to May 2010 and natural topography, landscape, or egress prevents the gate from swinging away from the pool.
.2528(a) Gate latches located at less than 54" shall require the use of key, combination lock or card reader or be located on the inside of the gate at least three inches below the top of the gate with no greater than 1/2" within 18" of latch mechanism.
Intent to suspend issued.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed one filter pressure gauge not properly functioning.
.2519(k) Provide operational pressure gauge on filter.
Intent to suspend.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed pump in structure with only 3 walls.
.2533(a) Pump room shall contain at least all pumps, chemical feeding equipment, and other mechanical and electrical equipment.
Sep 12, 2018 16 demerits · 4 violations
Inspector comments: Verified PDSC information.
Intent to suspend issued
Facility has 30 days to replace return inlet fittings and reduce gaps in deck.
Contact Chris Sells when repairs are complete at 704 576 8678.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
Observed 3 returns missing fitting covers.
.2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed ring buoys rope over 50 feet.
Corrected during inspection to 50 feet.
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed deck with gaps on ends of pool running from coping to fence.
.2537(2) Decks shall be kept in good repair.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed salt on ground not in chemical storage room.
.2533(4) Provide storage for pool chemicals in waterproof containers or store up off the floor.
May 30, 2017 10 demerits · 3 violations
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed fence damaged by tree-fall. Fence has been repaired with a wooden pallet. Repair fence properly.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed flow meter stuck. Repair flow meter.
#27 · Equipment room: filter backwash discharged through an air gap −2
Observed backwash line without air gap.
Oct 4, 2016 14 demerits · 4 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed 2 out of 7 weirs missing from skimmers. Replace them.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed 2 rubber feet missing on 1 ladder. Replace them.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
Observed 1 return missing the eyeball. Replace it.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed flow meter stuck. Fix it.
Jun 1, 2016 20 demerits · 6 violations
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
Observed some PDSC form information incorrect. Observed some EQ covers and some main drain covers not changed out sicne 2/2011 and to be expired. (Aquastar 5 year lifespan). Pool has Aquastar P12xxx Main drains, Haywoard HCP55 5.5HP 450GPM pump, 5HP4 and 2HP6 Aquastar EQ covers. The HP4 and p12 covers must be replaced and a new PDSC submitted. to the Health Dept. for approval.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed 1 ladder missing the rubber feet. Replace them.
#27 · Equipment room: filter backwash discharged through an air gap −2
Observed no air gap at backflow line.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Observed sink in Woman's room removed. Replace it. Provide toilet paper, hand soap, and a working handsink.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed 1 weir our of 7 missing. Replace it.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed flow meter stuck. Replace it.
May 21, 2015 22 demerits · 6 violations
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Observed two equalizer covers missing. Corrected onsite.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
Maintain weekly writted records for cyanuric acid.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed minor debris on pool floor. Keep floor free of debris.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed minor debris in skimmers. Keep skimmers free of debris.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed loose ladder. Tighten.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Observed no paper towles in mens restroom.
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “AURORA FLATS” or State ID 2060530305). Inspection type (routine vs. follow-up) is not published in the county's data.