RESIDENCES @ BROOKLINE

8816 ASPINWALL DR, Charlotte, NC 28216
Year-Round Swimming Pool · NC permit/State ID 2060530334
Latest result16 demerits
Last inspectedOct 28, 2026
Inspections on record26
On record sinceSep 25, 2015

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

01734 Sep 25, 2015: 0Jun 7, 2016: 8Sep 21, 2016: 6Mar 21, 2017: 20Oct 26, 2017: 34May 9, 2018: 30Nov 5, 2018: 12Jan 22, 2019: 34Oct 17, 2019: 6May 26, 2020: 4Oct 14, 2020: 6Mar 29, 2021: 8Nov 3, 2021: 0May 4, 2022: 0Sep 13, 2022: 10Mar 28, 2023: 22Jun 7, 2023: 6Jun 8, 2023: 0Oct 24, 2023: 20Mar 20, 2024: 12Apr 19, 2024: 0Nov 12, 2024: 22Mar 11, 2025: 22Nov 17, 2025: 22Mar 23, 2026: 10Oct 28, 2026: 16
Sep 25, 2015Lower is betterOct 28, 2026

Inspections & violations

Oct 28, 2026 16 demerits · 4 violations
Inspector comments: POOL IS NOT APPROVED FOR NIGHT SWIMMING. SIGNS GIVE THE CLOSING TIME OF THE POOL AS 10PM. THE POOL CANNOT BE OPEN FOR SWIMMING AFTER SUNSET OR BEFORE SUNRISE. CHANGE THE SIGNS TO REFLECT THIS, FOR EXAMPLE THEY COULD READ “POOL OPEN FOR SWIMMING FROM DAWN TO DUSK” OR “POOL OPEN FOR SWIMMING FROM SUNRISE TO SUNSET”. MAIN DRAIN COVERS EXPIRE 5/15/2030 POOL IS ISSUED AN INTENT TO SUSPEND FOR THE MISSING WEIRS, THE GATES NOT LATCHING, AND THE MESH BEING DAMAGED ON ONE GATE ALLOWING A LARGE GAP WITHIN 18 INCHES OF THE BAR. DEADLINE IS 11/27/2026. FAILURE TO CORRECT THE ISSUES MAY RESULT IN CLOSURE OF THE POOL. CONTACT C. ELMORE AT 704-507-6814 WHEN THE CORRECTIONS ARE MADE. THE POOL HEATER IS TURNED OFF.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Observed gaps in the record book. The checks must be made and recorded for every day the pool is open.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. Observed 4 weirs missing out of 7. Replace all of the weirs.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Gate latches located at less than 54" shall require the use of key, combination lock or card reader or be located on the inside of the gate at least three inches below the top of the gate with no greater than 1/2" within 18" of latch mechanism. Observed gate mesh damaged to a point where their is a gap greater than 1/2 inch. This must be corrected. Observed 2 of the gates not latching. This must be corrected.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept in good repair. Observed some deck damage. Correct any deck damage.

View this inspection on the county portal ›

Mar 23, 2026 10 demerits · 3 violations
Inspector comments: Inspection conducted with CPO Jeff Kiker. Coping chipping at sunshelf. Maintain in good condition.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
One skimmer basket cracked. .2518(k) Replace missing or damaged skimmer basket. - Corrected, operator has it on order.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter stuck. .2518(g) Keep flow meter operational. - Corrected.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Dry chemicals stored in pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.

View this inspection on the county portal ›

Nov 17, 2025 22 demerits · 5 violations
Inspector comments: Inspection conducted with inspector Niejel Wilkins, and CPO Jeff Kiker. Inspection led by Niejel Wilkins. Intent to suspend issued 7)
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Leaves on pool floor and floating on pool surface. .2537(14) Keep pool surface and pool floor free of debris. - Intent to suspend item.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Skimmers not functioning. .2518(k) The flow-through rate through any one skimmer shall be between 20 GPM and the maximum flow rated under NSF 50. - Corrected, pump basket was full of leaves.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Throw rope too short. .2530(a) Provide USCG approved ring buoy with attached 50 foot throw rope at least 1/4” in diameter. - Corrected.
#22 · Premises: emergency telephone provided −6
Kings III operator not able to hear us. .2530(f) Emergency phone shall remain operable. - Corrected.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Dry chemicals stored in pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.

View this inspection on the county portal ›

Mar 11, 2025 22 demerits · 6 violations
Inspector comments: Inspection conducted with supervisor Hope McIntosh and CPO Jeff Kiker. Office phone number posted at emergency phone. To avoid confusion, recommend only posting phone number for emergency phone. Intent to suspend issued 7) 17)
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Pool floor with leaves and debris. .2537(14) Keep pool surface and pool floor free of debris. - Intent to suspend item.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Skimmer baskets with leaves. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Corrected. Missing 2 of 7 weirs. .2518(k) Replace missing weirs.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Handrail loose. .2521 Install handrails per manufacturer instructions.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Throw rope too short. .2530(a) Provide USCG approved ring buoy with attached 50 foot throw rope at least 1/4” in diameter. - Corrected.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Some deck chairs beside the pool. .2522(a) Provide 6 ft of clear walking space around the pool at all times. - Corrected. Some skimmer lids appear to have been pushed up from frost heave, creating trip a hazard. .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. - Intent to suspend item.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Dry chemicals stored in pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. Fan off in pump room. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room. - Corrected. Fan off in chemical storage room. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room. - Corrected.

View this inspection on the county portal ›

Nov 12, 2024 22 demerits · 6 violations
Inspector comments: Inspection conducted with inspectors Noel Lamarre, Jeremy Stawinsky, and CPO Jeff Kiker.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Recently changed to Greystar log sheet. No place for main drain checks. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity. - Corrected. Operator will check main drains instead of lights.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Some skimmer baskets with leaves. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Corrected. Missing 2 of 7 weirs. .2518(k) Replace missing weirs.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Handrail loose. .2521 Install handrails per manufacturer instructions.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Throw rope 46.5 feet long. .2530(a) Provide USCG approved ring buoy with attached 50 foot throw rope at least 1/4” in diameter. - Corrected.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
More than 2” gap under the fence near grill area. .2528(a) Maintain 2" or less under fence and/or gate (post-May 2010). - Corrected. Gate by clubhouse not self-latching. .2528(a) Access gates shall swing away from the pool and be self-latching, self-closing. - Corrected.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Dry chemicals stored in pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.

View this inspection on the county portal ›

Apr 19, 2024 0 demerits · 0 violations
Inspector comments: Visit conducted with CPO Jeff Kiker. Observed good record keeping. Intent to suspend lifted.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Mar 20, 2024 12 demerits · 3 violations
Inspector comments: Inspection conducted with inspector Daniel Squirewell and CPO Jeff Kiker. Motor on filtration pump recently replaced. Electrical permit E4552347 passed inspection 2-7-2024.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
No recent main drain or cyanuric acid checks. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity. - Intent to suspend item.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Some skimmer baskets with leaves. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Corrected. Missing 1 of 7 weirs. .2518(k) Replace missing weirs.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter stuck. .2518(g) Keep flow meter operational. - Corrected.

View this inspection on the county portal ›

Oct 24, 2023 20 demerits · 5 violations
Inspector comments: Inspection conducted with inspector Jordan Johnson and CPO Jeff Kiker. *NOTE* outdoor pool with an attached heater. Heater not operating at the time of inspection. Skimmer equalizer lines at sunshelf recently plastered over on the sunshelf and plugged in the skimmer per state guidelines. PDSC form updated and verified. The rest of the equalizer lines were abandoned when the pool was recently replastered.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Skimmer baskets full. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Corrected. Missing 1 of 7 weirs. .2518(k) Replace missing weirs.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
More than 2” gap under the fence near grill area. .2528(a) Maintain 2" or less under fence and/or gate (post-May 2010). - Corrected.
#18 · Premises: lifeguards present or warning signs posted −4
Pump room recently painted. Signage taken down. .2530(c) Provide "Warning - No Lifeguard on Duty" in 4" lettering. - Corrected. Pump room recently painted. Signage taken down. .2530(c) Provide "Children should not use the swimming pool without adult supervision." in 1" lettering. - Corrected. Pump room recently painted. Signage taken down. .2530(c) Provide "Adults should not swim alone." in 1" lettering. - Corrected.
#19 · Premises: signs prohibit glass containers or pets in pool area −4
Pump room recently painted. Signage taken down. .2530(d) Provide a sign prohibiting pets and glass containers in the pool area. - Corrected.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Spare pump basket not observed. .2518(e) Provide a spare basket for pump.

View this inspection on the county portal ›

Jun 8, 2023 0 demerits · 0 violations
Inspector comments: Inspection conducted with CPO Jeff Kiker. New motor installed on bubbler pump. Electrical permit E4425566 passed inspection 5-31-2023. Items from previous pre-permit inspection have been corrected. Noticed that skimmers at sunshelf were still functioning when bubbler pump was off. Will need to update both PDSC forms to correctly reflect what is installed on each system. Permit issued No Night Swimming Paper permit will be available on our website https://health.mecknc.gov/envhealth/pools in 3-5 business days for your records.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Jun 7, 2023 6 demerits · 1 violation
Inspector comments: Inspection conducted with CPO Jeff Kiker. New motor installed on bubbler pump. Electrical permit E4425566 passed inspection 5-31-2023. Pre-permit inspection did not pass 5) There is a $100 re-inspection fee that must be paid prior to scheduling a re-inspection by calling our office (980-314-1620) and paying with a credit card.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
Pool recently replastered. Equalizer lines plastered over on the wall, pop-up covers in the skimmers. Will need to abandon per state guidelines. .2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance. - Pre-permit item.

View this inspection on the county portal ›

Mar 28, 2023 22 demerits · 7 violations
Inspector comments: Inspection conducted with CPO Jeff Kiker and CPO Justin Brevard. Kings III and 911 operator had difficulty hearing all that I said. Recommend checking the emergency phone line and equipment. Outer rope on ring buoy starting to fray. Recommend replacing. Note: Feature pump down for repairs. If pump or motor are replaced will need an electrical inspection from Code Enforcement. If replacing the pump will need to update PDSC form and go through in-field plan review. Intent to suspend issued 5) 7)
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Spotty records. No records for November, December, or February. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity. - Intent to suspend item.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Pool floor and surface with debris. .2537(14) Keep pool surface and pool floor free of debris. - Intent to suspend item.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Skimmer baskets full. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Corrected.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Some escutcheon plates missing. .2521 Install ladders per manufacturer instructions.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Spring loaded vacuum cap removed to install threaded vacuum adapter. .2518(f) Provide a vacuum cap or self-closing cap for pools built after May 1, 2010. - Corrected.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Dry chemicals stored in pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
No toilet paper in restroom. .2526(l) Provide toilet paper and dispensers in restrooms.

View this inspection on the county portal ›

Sep 13, 2022 10 demerits · 2 violations
Inspector comments: Inspection conducted with Jeff Kiker. Ring buoy worn. Recommend replacing with new US Coast Guard approved ring buoy and 50 foot throw rope.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Water level above the skimmers. .2518(k) Water level shall be maintained to assure skimmers are operable. - Corrected.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Throw rope not attached to ring buoy. .2530(a) Provide USCG approved ring buoy with attached 50 foot throw rope at least 1/4” in diameter. - Corrected.

View this inspection on the county portal ›

May 4, 2022 0 demerits · 0 violations
Inspector comments: Inspection conducted with Jeff Kiker. Bricks and fence post loose on upper section of fence. Recommend repairing. Low flow in far skimmer on sunshelf. Recommend adjusting flows in other skimmers to get better pull from that skimmer or checking the line for blockages. Facility now being managed by Wood Residential. Pool application updated with new contact information. Permit issued. Paper permit will be on our website, Meckpools.Charmeck.org, in 3-5 business days for your records.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Nov 3, 2021 0 demerits · 0 violations
Inspector comments: Inspection conducted with inspector Naly Lor and CPO Jeff Kiker. Due to COVID-19 precautions, inspection was not signed by the operator. Observed some missing main drain checks. Ensure Chlorine, pH, and main drains are checked daily. Cyanuric Acid and Total Alkalinity are checked weekly. Feature pump motor recently replaced. Per the CPO the work was done by the pool builder. Not able to locate the electrical permit. Will follow up over the next week to ensure electrical permit was obtained and passing inspection was received by Code Enforcement. Failure to provide this documentation will result in a suspension of the pool permit.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Mar 29, 2021 8 demerits · 2 violations
Inspector comments: Inspection conducted with Jeffrey Kiker. Due to COVID-19 precautions, inspection was not signed by the operator. 2021 pool permit sticker will be mailed. Ensure that sticker is posted in the pool area. “Executive Order No. 141 or subsequent Orders are in effect unless such Orders are rescinded or superseded by another applicable Order.”
#22 · Premises: emergency telephone provided −6
Phone number posted does not match what 911 has. .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Corrected by operator.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Dry chemicals stored in pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.

View this inspection on the county portal ›

Oct 14, 2020 6 demerits · 2 violations
Inspector comments: Inspection conducted with Jeffrey Kiker. Due to COVID-19 precautions, inspection was not signed by the operator. Filtration Pump motor recently replaced with new, 3 phase motor. Electrical permit E3798510 obtained and passed inspection on 8-5-2020 Phone number posted and that Kings III/911 has is for main office. Ensure that call back number is for the emergency phone and that phone rings or picks up automatically so that Kings III/911 can re-establish connection in the event of a dropped call. Operator will call Kings III. Facility recently changed management from Alliance to Greystar. All mailing/personnel information is still the same. “Executive Order No. 141 or subsequent Orders are in effect unless such Orders are rescinded or superseded by another applicable Order.”
#5 · Water quality: daily written records of water quality and test kit kept on site −4
New management company, using the old Greystar sheets, no place for main drain checks. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. - Corrected by operator.
#26 · Equipment room: valves and pipes identified by color codes or labels −2
Some piping not labeled. .2518(d) Piping and valves shall be labeled with color codes or labels.

View this inspection on the county portal ›

May 26, 2020 4 demerits · 1 violation
Inspector comments: Inspection conducted with Jeff Kiker. Due to COVID-19 precautions, inspection was not signed by the operator. Issues from previous inspection corrected. Deck recently repainted. Looks great and is slip resistant. New ring buoy and flow meter installed. Permit issued. No night swimming. “Issuance of a permit by this department does not negate closure required by Executive Order No. 120 or subsequent Orders in effect unless such Orders are rescinded or superseded by another applicable Order.”
#5 · Water quality: daily written records of water quality and test kit kept on site −4
No place on the pool log sheet for main drain checks. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Corrected by operator.

View this inspection on the county portal ›

Oct 17, 2019 6 demerits · 2 violations
Inspector comments: Deck paint peeling. No sand or grit in the paint that was applied this summer. Maintain deck non-slip. Use sand or grit when deck is repainted. Outer rope on ring buoy worn. Recommend replacing with a new, U.S. Coast Guard approved ring buoy before next pool season. Ensure that throw rope is a 50 foot rope.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Numbering on flow meter worn off. Install new flow meter with legible numbering.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Dry chemicals on the floor in the pump room. Some chemicals stored in the pump room. Store all chemicals in the chemical storage room off of the floor or in buckets.

View this inspection on the county portal ›

Jan 22, 2019 34 demerits · 8 violations
Inspector comments: Kings III and 911 operators had difficulty hearing me. Recommend checking lines and replacing any damaged equipment. Immediate suspension issued. 2) 3) Contact Will Harrison (704) 507-6824 to schedule a reinspection when issues have been corrected.
#2 · Water quality: disinfectant residual provided by −6
No chlorine in the pool. .2535(4) Maintain chlorine at least 1.0 ppm. - Immediate suspension item.
#3 · Water quality: pool water pH −6
pH 6.8. .2535(1) Maintain pH at 7.2 to 7.8. - Immediate suspension item.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
No recent records. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for total alkalinity and cyanuric acid weekly. Maintain cyanuric acid at no more than 100ppm. - Intent to suspend item.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Leaves on the pool floor. .2537(14) Keep pool surface and pool floor free of debris. - Intent to suspend item.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Water level above the skimmers. .2518(k) Water level shall be maintained to assure skimmers are operable. - Intent to suspend item. Skimmer baskets full of leaves. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Intent to suspend item.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
Depth markers on pool deck in the shallow end denoted in inches. .2523(c) Depth markers shall be 4 inches in height and of a contrasting color with the background, clearly visible or on a 6x6" tile. Depth markers shall include the word "feet" or symbol "ft" and shall be slip resistant when on the pool deck. - Intent to suspend item.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Vacuum port mostly unscrewed. Cap is intented to be tightly screwed into the pool wall and opened with a tool. An adapter may be needed to plug the vacuum hose into the vacuum line. .2518(f) Provide a vacuum cap or self-closing cap for pools built after May 1, 2010. - Intent to suspend item. Flow meter numbering worn off. .2518(g) Install flow meter capable of measuring 1.5 times the design flow rate, accurate within 10 percent of true flow per manufacturer's instructions. Flow meter shall be easy to read. - Intent to suspend item.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Chemicals stored in pump room. Properly store pool chemicals in chemical storage room. Fans in pump room and chemical storage room are off. Provide either forced air or cross ventilation. Leak in pump room. Fix leak.

View this inspection on the county portal ›

Nov 5, 2018 12 demerits · 3 violations
Inspector comments: Kings III and 911 operators had difficulty hearing me. This is a repeat issue. Recommend having Kings III service technician look at the box. Intent to suspend issued. 9)
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Leaves on pool floor. Keep pool surface and pool floor free of debris. Recommend vacuuming and cleaning skimmer baskets more often.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Most skimmer baskets full of leaves. Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Corrected by operator.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
.2523 Depth markers in shallow end of the pool denoted in inches. Depth markers on pool wall and pool deck shall be in at least 4 inch lettering or 6x6 inch tile. Tiles on pool deck shall be non-slip. Depth markings shall indicate the depth of the pool in feet and shall include the word "feet" or symbol "ft" to indicate the unit of measurement. Depth markers shall be spaced no more than 25 feet apart when measured along the perimeter of the pool. - Intent to suspend item.

View this inspection on the county portal ›

May 9, 2018 30 demerits · 7 violations
Inspector comments: Depth markers at pool shelf denoted in inches. Provide depth markers for pool floor and wall denoted in FEET or FT. Depth markers on pool deck need to be non-slip. 911 operator faint, operator had difficulty hearing me as well. Recommend turning up the volume on the emergency phone. Night swimming inspection scheduled for tomorrow at 5:45 AM. Permit issued.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Daily pool maintenance activities not recorded. Record daily Cl, pH, main drains and daily maintenance activities. Record at least weekly Cyanuric Acid and Total Alkalinity. Operator added this week's activities to the log book.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Pool water level above the skimmers. Maintain proper water level. Corrected by operator. Missing two weirs. Corrected by operator.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Throw rope too long. Corrected to 50 feet by operator.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Gaps > 2" under the fence. Corrected by operator.
#22 · Premises: emergency telephone provided −6
Phone number for recently installed Kings III phone does not match emergency phone sign. Corrected by operator.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Self-closing vacuum port mostly unscrewed. Corrected by operator.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Fans off in pump room and chemical storage room. Corrected by operator. Dry chemicals stored in pump room. Store chemicals in chemical storage room. Multiport leaking. Fix leak.

View this inspection on the county portal ›

Oct 26, 2017 34 demerits · 8 violations
Inspector comments: Immediate suspension issued. 3)
#3 · Water quality: pool water pH −6
pH 7.0. Maintain between 7.2 and 7.8. - Immediate suspension item.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Cyanuric acid above 100 ppm. Maintain cyanuric acid at no more than 100ppm. - Intent to suspend item. Total Alkalinity and Cyanuric Acid readings are 80 and 60 respectively every week for the last year. Test and record total alkalinity and cyanuric acid at least once a week. - Intent to suspend item.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
Vacuum port adapter in place. Remove vacuum port and plug vacuum line when not vacuuming the pool. Corrected.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Missing two weirs. Install functional weirs.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Ring buoy damaged. Throw rope missing. Provide US Coast Guard approved ring buoy with 50 foot throw rope. - Immediate suspension item.
#23 · Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 −4
Strong chlorine smell in pump room. Leak at chlorinator, chlorinator lid installed without seal. Corrected by operator.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Chlorine tabs stored in the pump room. Store all chemicals in the chemical storage room.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
No soap in the restroom. Provide soap.

View this inspection on the county portal ›

Mar 21, 2017 20 demerits · 5 violations
Inspector comments: 15) Outer rope on ring buoy starting to fray. Recommend replacing ring buoy before this summer. Intent to suspend issued. 21)
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
Vacuum cap removed. Vacuum hose adapter in place. Vacuum ports shall have self-closing caps designed to be opened with a tool. Corrected by operator.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Two skimmers missing weirs. Some baskets needed emptied. Maintain skimmers in good working order, clean baskets regularly.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Gap > 2" under fence. Maintain fence with no gaps > 2" under fence. Corrected by operator.
#21 · Premises: pool and deck lighting provided at pools that operate at night −4
Posted pool hours are 8AM to 10PM. Current permit restriction is no night swimming. Either restrict pool hours to daylight hours only, or provide at least 10 foot candles of lighting at all parts of the pool and pool deck. - Intent to suspend item.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Chemicals stored in the pump room. Store chemicals in the chemical storage room only. Corrected by operator.

View this inspection on the county portal ›

Sep 21, 2016 6 demerits · 2 violations
Inspector comments: 15) Throw rope and ring buoy worn. Recommend replacing with new US Coast Guard approved ring bouy and 50 foot throw rope before next pool season.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Missing two of seven weirs. Install functional weirs.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Some chemicals stored in pump room. Store pool chemicals in chemical storage room. Corrected.

View this inspection on the county portal ›

Jun 7, 2016 8 demerits · 2 violations
Inspector comments: 6) Note: Two SDX Retro equalizer line covers installed on sunshelf. These were installed with a sump. 22) Sign posted directly above emergency phone with incorrect address, corrects sign off to the side. Recommend correcting signage on main emergency phone sign. Permit posted expired. Go to Meckpools.charmeck.org to print new permit to post in pool area. Intent to suspend issued. 5) 8)
#5 · Water quality: daily written records of water quality and test kit kept on site −4
No main drain checks. Check daily Cl, pH, main drains and temperature when the heater is used. Check at least weekly TA and CYA. - Intent to suspend item.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Most baskets full, clean regularly. Missing two of seven weirs. Install functional weirs. One skimmer line clogged, no suction. Provide functional skimmer. - Intent to suspend item.

View this inspection on the county portal ›

Sep 25, 2015 0 demerits · 0 violations
Inspector comments: All weirs now in place.Volume issues on emergency phone corrected.Fans running in the pump room and chemical storage room.Flow meter not functioning. Corrected by operator. Flow during today's inspection was 140gpm.Issues correctedPermit issued.

No violations were recorded for this inspection.

View this inspection on the county portal ›