Oct 20, 2026 10 demerits · 3 violations
Inspector comments: Conducted inspection with operator Ean. Immediate suspension issued for chlorine level. Pool placed on E status and must close. Call EHS Devon when item is corrected and ready to reopen. 7049981122
Flow meter has been replaced with Aquastar FlowStar flow meter with 5% accuracy on specification sheet, measured correct
installation with 5x pipe diameter on inlet pipe (3 inch pipe, 15” pipe length inlet side and 2x pipe diameter on outlet side). Advised updating portion of PDSC form reflecting correct/new updated flow meter and submitting to pdsc@mecknc.gov,
noting that update is for new 5% accurate flow meter only. Flow required 120-150 gpm, observed 130 gpm.
Permit Restriction: 5% flow meter must remain operable. Flow required at least 120 gpm. Flow greater than 150 gpm exceeds the main drains. Suction Hazard.
Const. Date: 2/26/2016
Rope Length: 50'
Night Swim?: N
#2 · Water quality: disinfectant residual provided by −6
.2535(4) Maintain chlorine at least 1.0 ppm.
Chlorine observed at 0ppm. Immediate suspension item.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Some well equipment within 3 ft of pool piping and equipment. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
#26 · Equipment room: valves and pipes identified by color codes or labels −2
Some piping not labeled.
.2518(d) Piping and valves shall be labeled with color codes or labels.
Mar 31, 2026 10 demerits · 4 violations
Inspector comments: Flow meter has been replaced with Aquastar FlowStar flow meter with 5% accuracy on specification sheet, measured correct installation with 5x pipe diameter on inlet pipe (3 inch pipe, 15” pipe length inlet side and 2x pipe diameter on outlet side). Took picture verification. Advised updating portion of PDSC form reflecting correct/new updated flow meter and submitting to pdsc@mecknc.gov, noting that update is for new 5% accurate flow meter only. Flow required 120-150 gpm, observed 135 gpm.
No night swimming. Pool not heated.
Inspection with Ean Wrightson
“A” Open for Business
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Records missing weekly total alkalinty and cyanuric acid.
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
Operator checked, recorded and corrected.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Some well equipment within 3 ft of pool piping and equipment. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
#26 · Equipment room: valves and pipes identified by color codes or labels −2
Some piping not labeled.
.2518(d) Piping and valves shall be labeled with color codes or labels.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
Shower off at time of inspection.
.2526(h) Shower(s) shall be provided.
Jul 7, 2025 8 demerits · 3 violations
Inspector comments: Visit to pool to lift suspension and conduct inspection. Previous permit items have been corrected.
Changed to “A” Open for Business
Issued permit. No Night Swimming. Flow meter must remain operable between 120 to 150 GPM, suction hazard.
Note: Flow meter only correct to 10% accuracy. Must be corrected after 2025.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Electrical box creating horizontal less than 45” in height by showers.
.2528(a) Maintain 45" between bottom horizontal and next horizontal on fence and/or gate (post-May 2010). Operator added piece of sheet metal to eliminate horizontal. Corrected.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Light out in equipment room.
.2533(b) Provide sufficient lighting in pump room.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
Spigot by shower missing backflow prevention device. .2512(b) Water introduced into the pool, either directly or by the circulation system, shall be supplied through an air gap, anti-siphon vacuum breaker, or backflow preventer.
Feb 18, 2025 42 demerits · 11 violations
Inspector comments: Immediate suspension issued for water quality and emergency phone. Contact Marie Daley at 704-507-6806 when permit items are in compliance to lift suspension. Other permit items to verify on a return visit include records, pool floor being clean and 6’ clearance around pool.
Main drains and skimmer equalizer covers expire in May 2025. Replace and submit updated PDSC form to pdsc@mecknc.gov for approval prior to expiration. Pool permit will be suspended immediately at expiration. More information on website https://eh.mecknc.gov/pools pool ID 530343
Inspection with Terrance Jacobs
“E” Immediate Suspension staus
No Night Swimming. Pool not heated.
Motor replaced. Ensure proper permits were pulled.
#2 · Water quality: disinfectant residual provided by −6
Chlorine 0.2 ppm at time of inspection.
.2535(4) Maintain chlorine at least 1.0 ppm.
*Immediate suspension item
#3 · Water quality: pool water pH −6
PH 6.8 at time of inspection.
.2535(1) Maintain pH at 7.2 to 7.8.
*Immediate suspension item
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Records missing last days of entries and maintenance.
.2535 (11) The pool operator shall inspect the pool at least daily and maintain written records.
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
*permit item
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed leaves, a brick and debris on pool floor. .2537(14) Keep pool surface and pool floor free of debris.
*Permit item
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Debris in skimmers. Operator cleaned and corrected.
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Ladder loose on left side of pool. Keep tightened. .2521 Install ladders per manufacturer instructions.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Chairs within 6’ of pool. .2522(a) Provide 6 ft of clear walking space around the pool at all times.
*permit item
#22 · Premises: emergency telephone provided −6
Emergency phone not working at time of inspection.
.2530(f) Emergency phone shall remain operable.
.2530(f) Emergency notification systems must provide 24 hr. monitoring, be capable of routing calls to 911, and be able to electronically transfer Automatic Number and Locator Identification for the phone.
*Immediate suspension item
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
One bag of dry chemicals on floor at time of inspection.
.2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
Shower off at time of inspection.
.2526(h) Shower(s) shall be provided.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
Spigot by shower missing backflow prevention device. .2512(b) Water introduced into the pool, either directly or by the circulation system, shall be supplied through an air gap, anti-siphon vacuum breaker, or backflow preventer.
Jul 18, 2024 14 demerits · 5 violations
Inspector comments: Issued local permit sticker. “A” Open for Buiness
No Night swimming.
Main drains expire in May 2025. Advised replacement and approval of PDSC be submitted prior to expiration to avoid permit action.
Electrical box (horizontal) by showers must be covered at angle/eliminate horizontal for 2025 permit.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Records missing weekly TA and CYA.
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
Operator checked, recorded and corrected.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Ladder loose on left side of pool. Keep tightened. .2521 Install ladders per manufacturer instructions.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
One gate not self-latching at time of inspection.
.2537(b) All gates and doors shall be self-closing, self-latching. Operator corrected to self close self latch.
Electrical box creating horizontal less than 45” in height by showers.
.2528(a) Maintain 45" between bottom horizontal and next horizontal on fence and/or gate (post-May 2010). Lack of severity does not warrant permit action at this time, but must be corrected for 2025 permit.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Toilet paper missing in men’s restroom stall. .2526(l) Provide toilet paper and dispensers in restrooms.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
Spigot by shower missing backflow prevention device. .2512(b) Water introduced into the pool, either directly or by the circulation system, shall be supplied through an air gap, anti-siphon vacuum breaker, or backflow preventer.
Aug 17, 2023 18 demerits · 4 violations
Inspector comments: 30 Day Intent to Suspend (ITS) issued for records, gates and flow meter. Contact Marie Daley at 704-506-6806 when in compliance to lift ITS.
No Night Swimming
“W” ITS status
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Records missing weekend entries.
.2535 (11) The pool operator shall inspect the pool at least daily and maintain written records.
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
*permit item
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
One gate not self-latching or closing at time of inspection. Electrical box creating horizontal less than 45” in height by showers.
.2537(b) All gates and doors shall be self-closing, self-latching.
.2528(a) Maintain 45" between bottom horizontal and next horizontal on fence and/or gate (post-May 2010).
*Permit item
#22 · Premises: emergency telephone provided −6
Table blocking emergency phone at time of inspection.
.2530(f) Emergency phone shall be accessible to all pool users. Operator moved table and corrected.
**NOTE: Emergency operator was cut off midway through call for automated response. Call reconnected, but advised reaching out to phone company to ensure there is not an issue during an emergency situation.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter not operable.
.2518(g) Keep flow meter operational.
*Permit item
Mar 1, 2023 20 demerits · 5 violations
Inspector comments: 30 Day Intent to Suspend (ITS) items include: record keeping, pool floor, weirs, skimmer baskets, skimmer lid. Contact Marie Daley at 704-507-6806 when all items are in compliance to lift ITS. Failure to correct by ITS expiration will result in immediate suspension of permit until items are corrected.
“W” Status
No Night Swimming
Note: Emergency phone did not connect from Kings III on first try and after second attempt and call connected, phone beeped loudly and did not disconnect. Ensure phone remains operable at all times in case of emergency. Since phone is operable and did connect after multiple attempts, did not suspend permit
Inspection with Terrance Jacobs
#5 · Water quality: daily written records of water quality and test kit kept on site −4
No pool closed signs posted at pool, but records indicated “Pool Closed.” If pool is not closed with signage posted at each bather entrance, daily records must be kept. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
*Permit item
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed leaves and debris on pool floor. .2537(14) Keep pool surface and pool floor free of debris.
*Permit item
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Multiple weirs missing. Skimmer lid missing. Debris in skimmers. .2518(k) Replace missing weirs.
.2518(k) Replace damaged skimmer lid.
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.
*permit item.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Buoy and body hook behind large bushes, not conveniently located or accessible for use in case of emergency.
.2530(a) Lifesaving equipment should be conveniently located.
Moved and corrected. Will ensure permanent place is made for life saving equipment on future visit that is accessible.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Pump room unlocked at time of inspection. .2533(a) The equipment room door shall have a permanent lock and be kept locked when not in use by the pool operator.
Sep 8, 2022 18 demerits · 4 violations
Inspector comments: Inspection completed with Crystal Silva present.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide USCG approved ring buoy. A rescue tube with lifeguard may be substituted for ring buoy. Observed ring buoy beckets severely deteriorated. CDI- ring buoy replaced.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing, self-latching. Observed 1 gate not self closing. CDI- repaired.
#18 · Premises: lifeguards present or warning signs posted −4
.2530(c) Provide "Children should not use the swimming pool without adult supervision." in 1" lettering. Observed sign missing the word “THE”. CDI- new sign added to pool deck.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Observed stuck flow meter.
Mar 1, 2022 18 demerits · 4 violations
Inspector comments: Inspection completed with Crystal Silva present. No signature due to COVID.
Permit suspended due to chlorine at 0.4ppm. Maintain at 1.0ppm or above. Contact Eli Freese at 704.621.2298 once corrected to reopen pool.
#2 · Water quality: disinfectant residual provided by −6
.2535(4) Maintain chlorine at least 1.0 ppm. Observed chlorine at 0.4 ppm. Permit suspended.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Observed incomplete records for month of February, 2022. Ensure records are kept daily or an intent to suspend the permit may be issued.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed debris on pool floor.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(e) Provide a spare basket for pump. Observed no spare pump basket.
Sep 30, 2021 12 demerits · 3 violations
Inspector comments: Inspection completed with Carmelo Roman present. No signature due to COVID.
Intent to suspend permit issued for record keeping. Observed no main drain safety checks being recorded and intermitting record keeping on other days for the month of September, 2021. Correct by 10/30/2021. Contact Eli Freese at 704.621.2298 with questions.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Observed no main drain safety checks being recorded in log book. Intent to suspend issued. Ensure chlorine, pH, main drain checks are recorded daily and TA and CA are recorded at least weekly. Correct by 10/30/2021 or pool permit will be suspended.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
.2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. Observed vacuum port cover not installed. No suction at line at time of inspection. CDI- line cover was installed.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(e) Provide a spare basket for pump. Observed no spare pump basket.
Apr 13, 2021 8 demerits · 2 violations
Inspector comments: NOTE: Observed KINGS III emergency phone connected to 911 but would not disconnect after several attempts (busy signal received and box would not shut off). After resetting the box manually via circuit board I was able to verify the phone number listed was the correct number. The 911 operator also had all correct information. Maintenance Supervisor Chris Carver scheduled a service visit with KINGS III for technical support on 4/21/2021.
Inspection completed with Chris Carver. No signature due to COVID-19.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing, self-latching. Observed 1 gate not self-closing. CDI- hinges tightened; gate repaired to be self closing.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Observed stuck flow meter.
Oct 6, 2020 4 demerits · 1 violation
Inspector comments: Inspection completed with Jon Faucette on site. No signature due to COVID-19.
General comment: Observed 1 chair and table within 6 feet of pool. Maintain clear walking space of 6 feet around perimeter of pool.
**NOTE** Main drains expire in May 2021. Replace and resubmit PDSC paperwork prior to expiration.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Observed flow meter non-operational.
Mar 9, 2020 22 demerits · 5 violations
Inspector comments: Intent to suspend permit issued for the following non-compliant items: NO SPOT IN RECORD BOOK FOR RECORDING MAIN DRAIN CHECKS, DISTANCE BETWEEN HORIZONTAL MEMBERS OF GATES IS 36 INCHES, SOME DEPTH MARKERS ON POOL DECK AND POOL WALL MISSING WORD 'FEET' OR 'FT.', AND SIGNAGE FOR "CHILDREN SHOULD NOT USE THE SWIMMING POOL WITHOUT ADULT SUPERVISION" AND "ADULTS SHOULD NOT SWIM ALONE" IS ONLY 5/8 INCHES TALL, MUST BE 1 INCH MINIMUM. CORRECT ITEMS WITHIN 30 DAYS.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Observed written records missing location to record main drain checks. Intent to suspend issued.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
.2523(c) Depth markers shall include the word "feet" or symbol "ft". Observed some depth markings on pool deck and pool wall missing 'feet' or 'ft.' Intent to suspend issued.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(b) Horizontals shall not be located less than 45" in height. Observed distance between horizontal members at 35 inches on all gates that lead onto pool deck. Intent to suspend issued. May correct by placing solid material between members that exceeds up to 45 inches.
#18 · Premises: lifeguards present or warning signs posted −4
.2530(c) Provide "Children should not use the swimming pool without adult supervision." in 1" lettering. Observed lettering at 5/8 inches. Intent to suspend issued.
.2530(c) Provide "Adults should not swim alone." in 1" lettering. Observed lettering at 5/8 inches. Intent to suspend issued.
#22 · Premises: emergency telephone provided −6
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Observed sign with wrong address listed and no phone number listed. CDI- updated sign provided today with correct information.
Oct 15, 2019 20 demerits · 4 violations
Inspector comments: Issued immediate suspension for #15 and #22.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed debris in skimmers. Keep skimmers free of debis
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Throw rope was in several peices to to excessive brittleness. Replace with a 50 foot rope.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed deck chairs within 6 feet of pools edge. Corrected onsite.
#22 · Premises: emergency telephone provided −6
Observed emergency phone inoperable. 911 operator could be heard, but she could not hear me.
May 29, 2019 18 demerits · 5 violations
Inspector comments: Pool operator stated that pool operates from dawn until dusk and no night swimming provided.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed staining on pool walls and floor. Observed some sand on pool floor. Maintain clean.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. Observed some of fence less than 48 " and between 45" and 46" in some areas. No permit action taken. Pre-2010 pool.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed some pool furniture less than 4 feet from edge of pool. CDI, furniture relocated to provide required deck clearance.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Observed flow meter stuck. CDI, flow meter calibrated while on-site.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed chemical and equipment room left unlocked.
.2533(a) The equipment room door shall have a permanent lock and be kept locked when not in use by the pool operator.
Sep 4, 2018 6 demerits · 2 violations
Inspector comments: Observed some settling at the deck around the pool causing the deck sections to become uneven. Correct this as it will become a trip hazard.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed ladder missing rubber foot. Replace the foot.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
OBSERVED SOME PORTIONS OF THE FENCE TO BE 46"-47" DUE TO PINE NEEDLE LANDSCAPING. POOL CONSTRUCTED PRIOR TO 2010. NO PERMIT ACTION TAKEN.
Apr 20, 2018 6 demerits · 2 violations
Inspector comments: OBSERVED GLASS BEER BOTTLES IN TRASH CAN INSIDE POOL ENCLOSURE. ENFORCE THE "NO GLASS" SIGN. BROKEN GLASS IN POOL ENCLOSURE CAN RESULT IN CLOSURE OF THE POOL.
IF NIGHT SWIMMING IS TO BE ALLOWED, AN EVALUATION OF POOL AND DECK LIGHTING MUST BE PERFORMED. CALL C. ELMORE (704-507-6814) TO SCHEDULE.
STICKER # 18-600228 ISSUED.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
OBSERVED RUBBER FOOT MISSING FROM 1 LADDER. REPLACE IT.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
OBSERVED SOME PORTIONS OF THE FENCE TO BE 46"-47" DUE TO PINE NEEDLE LANDSCAPING. POOL CONSTRUCTED PRIOR TO 2010. NO PERMIT ACTION TAKEN.
Nov 16, 2017 38 demerits · 9 violations
#3 · Water quality: pool water pH −6
Observed pH to be 7.0. pH must be 7.2-7.8. I.S. Issued.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Observed no records from November 2017 and observed most of the data missing from October 2017. Daily and Weekly inspections must be carried out and recorded properly every day the pool is open.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed one ladder missing the rubber foot. Replace the foot.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed ring buoy throw rope to be 57 feet long. Rope was corrected to 50 feet. -CDI.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed some fence sections to be lower than 48 inches due to landscaping having raised the effective ground height. Fence shall be 48 inches high or higher. Pool constructed before 2010.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed pool furniture too close to the water edge. Furniture shall be 6 feet back from water edge. Items moved back.
#22 · Premises: emergency telephone provided −6
Observed 911 phone not to connect. Phone must be functional. I.S. Issued
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed flow meter stuck. Fix flow meter.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed leak at filter. Fix leak.
May 12, 2017 6 demerits · 2 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed discoloration on pool walls and floor. Clean pool.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed chemical and pump room unlocked during inspection. Both chemical and pump room should be locked when not in use.
Dec 9, 2016 20 demerits · 4 violations
Inspector comments: Issued .immediate suspension for #3 and #6.
#3 · Water quality: pool water pH −6
Observed pH at 7.0. Maintain pH between 7.2 and 7.8
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
EQ line covers have been changed. No current PDSC form on record. Fill out new PDSC form completely and submit to Health Dept for approval.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed debris on pool floor. Keep pool floor free of debris.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed leaves and debris in skimmers. Keep skimmers free of debris.