0demerits
MARQUIS OF CARMEL VALLEY
6905 POPPY HILLS LN, Charlotte, NC 28226
Year-Round Swimming Pool · NC permit/State ID 2060530345
Latest result0 demerits
Last inspectedAug 5, 2026
Inspections on record22
On record sinceJun 30, 2016
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Jun 30, 2016Lower is betterAug 5, 2026
Inspections & violations
Aug 5, 2026 0 demerits · 0 violations
Inspector comments: Conducted inspection with CPO. All items in compliance. Pool remains on A status and in good standing.
NIGHT SWIMMING APPROVED - 3/2/2023 - REVISIT NEEDED for 2026
Const. Date: 2/11/1989 Rope Length: 24'
No violations were recorded for this inspection.
May 18, 2026 0 demerits · 0 violations
Inspector comments: Conducted inspection with CPO. All items in compliance. EHS recommends lowering chlorine for bather comfort. Pool remains in good standing and on A status.
Const. Date: 2/11/1989 Rope Length: 24' Night Swim?: Y
Night swimming must be re verified in 2026
No violations were recorded for this inspection.
Oct 22, 2025 24 demerits · 7 violations
Inspector comments: Inspection conducted with Glenn.
Bonding wire not attached to pump motor. G.S. 130A-2(3) Bonding wire shall be attached to the pump motor by a certified electrician. - Corrected.
Pool throw rope listed in our system as 24 ft. Appears to be less than 1.5x the width of the pool. Will follow up with the facility if changes are needed.
Electricians working to correct an issue in the pump room. Will check that automatic feeder shuts off when the pump is off on my return visit.
Facility permitted for night swimming. Did not verify lighting, will check on my return visit.
Facility has an automatic chemical feeder. Recommend having the chemical controller recalibrated.
Immediate suspension issued.
3)
Contact Will Harrison (704) 507-6824 to schedule re-inspection once issues have been corrected.
#3 · Water quality: pool water pH −6
PH 7.0. Operator adjusted, but went down to 6.8. .2535(1) Maintain pH at 7.2 to 7.8. - Immediate suspension item.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
Depth marker installed on expansion joint is loose. .2523(a) Provide depth markers on pool walls and pool deck next to the swimming pool. - Intent to suspend item.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Handrails missing escutcheon plates. .2521 Install handrails per manufacturer instructions.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Pre-2010 fence < 48” high in places. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier.
Pre-2010 fence with gaps > 4” under the fence at drainage basin. .2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010).
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter stuck. .2518(g) Keep flow meter operational. - Corrected.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Items stored next to pump equipment. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
#27 · Equipment room: filter backwash discharged through an air gap −2
No air gap for backwash line. .2513(b) Filter backwash shall be discharged through an air gap.
Feb 26, 2025 22 demerits · 6 violations
Inspector comments: Intent to suspend (ITS) for gates, doors, flow meter, records and deck.
Send verification of night lighting to Marie Daley at 704-507-6806.
Note: Main drains and skimmer equalizer lines expire 3/19/2025. Update and submit PDSC for approval. Pool permit will be immediately suspended at expiration if not updated.
Inspection with Glen Decker and Richard Ritch
“W” ITS status
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Records missing total alkalinity, and cyanuric acid weekly .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
*Permit item
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Some debris in skimmers. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Operator cleaned. Corrected.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
One door from club house not latching or alarmed at time of inspection. Gates being changed out with crash bars, not closing, latching at time of inspection. Mesh has been removed from bottom of latching mechanism.
.2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm.
.2528(a) Gate latches located at less than 54" shall require the use of key, combination lock or card reader or be located on the inside of the gate at least three inches below the top of the gate with no greater than 1/2" opening within 18" of latch mechanism.
*permit item
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Deck coping chipping by back skimmer.
.2537(2) Decks shall be kept in good repair.
*permit item
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter not legible and installed on a vertical. .2518(g) Install flow meter on return line per manufacturer instructions.
.2518(g) Flow meter be capable of measuring 1.5 times the design flow rate.
*Permit item
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Items within 3' clearance of piping and equipment. Lighting out in pump room. Pool built prior to 2004. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
.2533(b) Provide sufficient lighting in pump room.
Oct 3, 2024 26 demerits · 6 violations
Inspector comments: Main drains and skimmer equalizers expire in March 2025. Replace and submit updated PDSC form for approval prior to expiration to avoid permit action.
Send verification of Night Swimming to Marie Daley at 704-507-6806. Unable to verify at time of inspection.
Updated CPO to Richard Ritch
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Records missing total alkalinity, and cyanuric acid weekly .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
Operator checked and recorded. Corrected.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Some debris in skimmers. One weir stuck. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Operator cleaned basket and fixed weir. Corrected.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Rope deteriorating at time of inspection.
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Rope 24’. Operator replaced and corrected. Advised burning the end of the rope to keep it from fraying.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
6 inch tile coming up from edge of pool, greater than 1/2” offset.
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. Operator repaired and corrected.
#22 · Premises: emergency telephone provided −6
Emergency phone not transferring to 911 at time of inspection.
.2530(f) Emergency notification systems must provide 24 hr. monitoring, be capable of routing calls to 911, and be able to electronically transfer Automatic Number and Locator Identification for the phone. Operator called Kings III and repaired phone. Corrected.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Items within 3' clearance of piping and equipment. Pool built prior to 2004. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
May 2, 2024 4 demerits · 1 violation
Inspector comments: 5.) ADD "POOL CLOSED" FOR ANY DAYS NOT OPEN IN DAILY RECORDS
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
ONE FLOOR INLET NEAR GRILL AREA APPEARS BROKEN -- REPLACE
Jul 24, 2023 10 demerits · 3 violations
Inspector comments: General comment: Flow meter reading marks starting to fade. Advised replacement.
Night swimming lighting verified.
Pool not heated.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
One door from club house not latching or alarmed at time of inspection.
.2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm.
Operator adjusted to self-close, self-latch.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Some chairs within 6’ of pool. .2522(a) Provide 6 ft of clear walking space around the pool at all times. Moved chairs back and corrected.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Items within 3' clearance of piping and equipment. Pool built prior to 2004. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
Feb 16, 2023 8 demerits · 2 violations
Inspector comments: Verified Night Swimming. CPO changed bulb, all lights work.
Restroom renovations have been done since last inspection. Must send proof of coefficient of friction for flooring, proof that floors are slip resistant and mirrors are shatterproof. No glass allowed.
Floors should have coating applied to make slip resistant, if tiling is not rated for slip resistance. Fill out and submit general in-field plan review application with relevant information to Health department. Failure to submit renovation information prior to expiration of permit on 4/30/2023 will result in no permit to operate.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Buoy beckets peeled off of new buoy at time of inspection. This voids US Coast Guard approval. CPO adjusted and secured. Corrected.
.2530(a) Provide USCG approved ring buoy. A rescue tube with lifeguard may be substituted for ring buoy.
#32 · Dressing and sanitary facilities: floors smooth, slip-resistant, kept clean −2
Restrooms have been renovated and flooring does not appear to be slip resistant. .2526(c) Restroom floors shall be smooth to insure cleaning and slip-resistant.
This must be corrected prior to issuance of 2023 permit.
Sep 21, 2022 12 demerits · 3 violations
Inspector comments: Immediate suspension issued for emergency phone. Pool must remain closed with signage posted until suspension is lifted by health department. Contact Marie Daley at 704-507-6806 when in compliance to lift suspension.
Other permit items to be checked at return include: gates self closing self latching and doors onto pool deck self-closing self-latching or alarmed.
Deck cracking at ladder, less than 1/2” at time of inspection. Advised monitoring for repair before it worsens. If deck work is done, submit plans to Health Dept PRIOR to work done.
Lighting verified for Night swimming.
Inspection with Jordan Johnson and Randy Lundquist
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
One gate not latching at time of inspection.
.2528(a) Pool fence shall be at least 48" in height measured from outside of barrier.
One door from club house not latching or alarmed at time of inspection.
.2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm.
*permit item
#22 · Premises: emergency telephone provided −6
Emergency phone not calling back at time of inspection, going to unanswered line for office.
.2530(f) Emergency phone shall remain operable. Phone should connect back to audibly hear on receiving end when called back in case of emergency.
*Issued Immediate Suspension. Contact Marie Daley at 704-507-6806 when in compliance to lift suspension.
#33 · Dressing and sanitary facilities: hose bibbs and floor drains provided −2
No backflow prevention device on hose bib in women’s restroom. Provide backflow prevention
Mar 7, 2022 14 demerits · 4 violations
Inspector comments: General Comment:
Emergency phone address has "Apartment R" rather than pool phone, but correct address on 911 end. Advised reaching out to phone company/911 to update location to pool/office phone in case of emergency to properly locate.
Deck starting to crack by ladder and coping chipped out in some areas. Not 1/2" offset at this time, but advised repair before it worsens to avoid permit action on future inspections.
Verified lighting for Night Swimming. Pool not heated.
Inspection with Ron Ratzlaff
No signature due to COVID
#3 · Water quality: pool water pH −6
pH 8.0 at time of inspection. .2535(1) Maintain pH at 7.2 to 7.8. Operator adjusted feeder (Add acid, to lower pH) and corrected to 7.3
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
One gate not latching and fence height less than 48" in areas where dirt from construction and mulch from landscaping has piled up on outside of fence by spa area at time of inspection.
.2528(a) Pool fence shall be at least 48" in height measured from outside of barrier.
.2537(b) All gates and doors shall be self-closing, self-latching.
Operator cleared out dirt and mulch for fence height and adjusted gate to self-latch. Corrected.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Items within 3' clearance of piping and equipment. Some chemicals in pump room. Water on floor of pump room under pumps.Pool built prior to 2004. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
.2533(d) Pump room floor shall be kept dry and free of standing water.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
Shower off due to cold weather at time of inspection. .2526(h) Shower(s) shall be provided.
Sep 15, 2021 28 demerits · 7 violations
Inspector comments: Immediate Suspension issued for emergency phone and updating PDSC form. Pool MUST REMAIN CLOSED until suspension is lifted by Health Dept. Contact Marie Daley at 704-507-6806 when in compliance to lift suspension.
Doors onto pool deck is permit item that will be verified at return visit.
Verified lights for Night Swimming
Inspection with Glenn Decker
No signature due to COVID
Changed to "E" Immediate Suspension status
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
Pool pump observed at time of inspection Challenger CHII-NI-3FE, PDSC has Challenger CHII-NI-3F. Pump curve is same for both, but update to reflect correct pump. Pump has not been changed according to CPO, administrative error. 2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance.
*Permit item
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Tread missing on top ladder step.
.2521(b) Ladders shall have slip-resistant tread.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Buoy behind palms/bushes at time of inspection. Keep accessible. .2530(a) Lifesaving equipment should be conveniently located. Operator moved and corrected.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
One door from club house not latching or alarmed at time of inspection. Clubhouse under renovation.
.2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm.
*30 Day Intent to Suspend (ITS) item
#22 · Premises: emergency telephone provided −6
Emergency phone not working at time of inspection.
.2530(f) Emergency phone shall remain operable.
*Issued Immediate Suspension. Contact Marie Daley at 704-507-6806 when in compliance to lift suspension.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Items within 3' clearance of piping and equipment. Some chemicals in pump room. Pool built prior to 2004. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Clubhouse under construction. No sinks, handwashing fixtures available. Port-a-john outside restroom.
Provide sink, water, soap, hand drying at restrooms.
Mar 3, 2021 16 demerits · 5 violations
Inspector comments: ITS for doors self-closing, self-latching or audible alarm and flow meter.
Night Swimming lights not verified. Send verification of lighting to Marie Daley 704-507-6806 or marie.daley@mecknc.gov
Placed in "W" status.
Visit with Edward Irizarry
No signature due to COVID
Report to eirizarry@cwsapartments.com; ceaker@cwsapartments.com
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Debris in skimmers. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Operator emptied and corrected.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
One door from club house not latching or alarmed at time of inspection.
.2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm.
*30 Day Intent to Suspend (ITS) item. Contact Marie Daley at 704-507-6806 when in compliance to lift ITS.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter not operational at time of inspection. .2518(g) Keep flow meter operational.
*30 Day ITS item.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Items within 3' clearance of piping and equipment. Some chemicals in pump room. Pool built '89. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking
space in pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
Shower off due to cold weather at time of inspection. .2526(h) Shower(s) shall be provided.
Jul 13, 2020 2 demerits · 1 violation
Inspector comments: Inspection with: Ron Ratzlaff
Report sent to: ceaker@cwsapartments.com; eirizarry@cwsapartments.com
No signature due to COVID-19.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Items within 3' clearance of piping and equipment. Some chemicals in pump room. No backflow prevention device on hose bib by shower. Pool built '89. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
.2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
.2533(g) Provide a hose bib with backflow prevention device within 50 ft. of the equipment room.
Feb 26, 2020 10 demerits · 4 violations
Inspector comments: 30 Day Intent to Suspend for Lighting fixture detached from wall, offset greater than 2 inches, not in good repair.
"W" Intent to Suspend status.
Main drains and skimmer equalizer covers expire April 2020. Replace and submit updated PDSC Form prior to expiration to avoid permit action. Permit for 2020 will NOT be issued until drain covers are updated and approved.
Contact Marie Daley for Night Swimming visit for 2020 permit.
Showers off at time of inspection.
22) Emergency phone, Kings III operable, but callback number shares a line with fax line from Kings III phone. Line dials back to emergency phone when an emergency call has been made, but dials fax machine otherwise. Phone meets technical rule, but advised addressing this potential issue for emergency phone line. If changes are made, ensure compliance is met:
2530 (f) A telephone capable of directly dialing 911 or other emergency notification system shall be provided and
accessible to all pool users. A sign with legible letters shall be posted at the telephone providing dialing instructions, address of the pool location and the telephone number. Where the telephone does not directly access 911, the emergency notification system shall:
(1) Provide 24 hour monitoring of all incoming calls by a telecommunicator who answers only
emergency calls; (2) Be capable of routing calls to the local 911 telecommunicator via the 911 dedicated emergency
trunk line; and (3) Electronically transfer Automatic Number Identification and Automatic Locator Identification for
the emergency telephone at the pool to the Enhanced 911 system for all calls routed to 911.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Tread missing on bottom ladder step.
.2521(b) Ladders shall have slip-resistant tread.
#21 · Premises: pool and deck lighting provided at pools that operate at night −4
Light fixture protruding from wall creating gap/haxard. Only screwed in at top. .2537(9) Underwater light niches shall be maintained or covered so not to present a hazard.
*30 Day Intent to Suspend (ITS) item. Contact Marie Daley at 704-507-6806 when corrected to lift ITS.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Chemicals stored in pump room. Pool built prior to 2004. Items around piping for pool equipment.
.2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
.2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
#33 · Dressing and sanitary facilities: hose bibbs and floor drains provided −2
No backflow prevention at hose bibb by shower. Provide backflow prevention/anti-siphon device at hose bibb.
Sep 3, 2019 4 demerits · 2 violations
Inspector comments: Main drains and equalizers expire April 2020.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Paper towel dispenser in men's restroom stuck and not operable at time of inspection. .2626(m) Keep restrooms and fixtures clean and in good repair.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
No backflow prevention at shower outside. Provide anti siphon or backflow prevention.
Feb 25, 2019 8 demerits · 3 violations
Inspector comments: ITS for offsets greater than 1/2".
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Small nail protruding from caulk/grout greater than 1/2" by right side of pool when exiting clubhouse. Coping with cracks/chips and decking creating offsets greater than 1/2".2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile.
**30 Day Intent to Suspend item. Contact Marie Daley at 704-507-6806 when in compliance to lift ITS.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
Shower on pool deck operable, but turned off at time of inspection due to cold weather (winterize). .2626(h) Shower(s) shall be provided.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
No backflow prevention device on shower spigot or in men's restroom. Provide backflow prevention devices.
Aug 14, 2018 18 demerits · 5 violations
Inspector comments: ITS for lighting, no diving and depth markers.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Debris in skimmer baskets. Keep clean. Operator emptied. Corrected
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
Depth and 'No Diving' markers missing at 3'6" where new decking was installed. .2523(a) Provide depth markers on pool walls and pool deck next to the swimming pool. .2523(b) Provide depth markers spaced not to exceed 25 feet when measured along the perimeter of the pool..2523(d) The distance between no diving markers shall be no more than 25 feet perimeter or as the crow flies.
*30 Day Intent to Suspend. Contact Marie Daley at 704-507-6806 to lift ITS when issue is corrected
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Door from clubhouse not self-closing self-latching at time of inspection. Side gate propped open. All gates and doors must be self-closing self-latching. Operator corrected door to self-close, self-latch. Gate was unpropped. Corrected.
#21 · Premises: pool and deck lighting provided at pools that operate at night −4
Lighting fixtures not secured to wall. Lighting fixtures shall not present a hazard to the public.
*30 Day Intent to Suspend. Contact Marie Daley at 704-507-6806 to lift ITS when issue is corrected
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
Provide backflow prevention device on hose bibb in men's restroom.
Apr 19, 2018 16 demerits · 4 violations
Inspector comments: Issued local permit. No Night Swimming.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Skimmer baskets with leaves and debris. Keep clean. Operator cleaned. Corrected.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Grills placed in pool deck area making body hook and ring buoy inaccessible. Keep accessible at all times in case of emergency. Operator moved items for accessibility. Designated new permanent location for life saving equipment. Corrected.
*Note: Becketts starting to separate from buoy. Replace before next inspection to maintain US Coast Guard Approved status buoy (Rope 24')
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Gap on side gate greater than 1/2" within 18" of inside door latch (3.5").
.2528(a) Gate latches located at less than 54" shall require the use of key, combination lock or card reader or be located on the
inside of the gate at least three inches below the top of the gate with no greater than 1/2" witihn 18" of latch mechanism.Operator installed solid piece to create 18" no gaps greater than 1/2". Corrected.
Door from clubhouse not self-latching. Ground levels doors must self-close, self-latch or have audible alarm. Operator corrected door to self-close-self-latch.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Water on floor in pump room. Pump room floor shall be kept dry and free of standing water.
Maintain 3' clear walking space around equipment.
Nov 2, 2017 8 demerits · 2 violations
Inspector comments: 15. Ring buoy rope starting to fray. Reccomended replacing.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Debris, toys and leaves in skimmer basket. Keep clean. Operator cleaned. Corrected During Inspection (CDI).
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Decking by exercise area of clubhouse has loose gravel and is under repair with cones within 6' of pool. Maintain 6' deck clearance.
Coping starting to crack on spa side of pool. Two holes in decking for volleyball pole/net more than 1/2". Offsets shall be no more than 1/2". Cover/fill holes. Keep in good repair.
Feb 14, 2017 4 demerits · 1 violation
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed Several areas of chipping/ pitting on pool deck. Repair these areas.
Dec 1, 2016 8 demerits · 2 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed minor amount of debris in skimmers. Keep skimmers free of debris.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed one lounge chair within 6 feet of pools edge. Maintain 6 feet of deck clearance at all points.
Jun 30, 2016 2 demerits · 1 violation
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
back flow breaker needed on shower
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “MARQUIS OF CARMEL VALLEY” or State ID 2060530345). Inspection type (routine vs. follow-up) is not published in the county's data.