16demerits
HOME 2 SUITES BY HILTON CLT AIRPORT
4240 SCOTT FUTRELL DR, Charlotte, NC 28208
Year-Round Swimming Pool · NC permit/State ID 2060530371
Latest result16 demerits
Last inspectedSep 16, 2026
Inspections on record18
On record sinceAug 19, 2016
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Aug 19, 2016Lower is betterSep 16, 2026
Inspections & violations
Sep 16, 2026 16 demerits · 4 violations
Inspector comments: Inspection conducted with CPO Richard Wendt.
All out of compliance items were corrected during the inspection with the exception of standing water in the pump room. Shown to operator.
Const. Date: 8/2/2016 Rope Length: 19' No night swimming PERMIT RESTRICTION - FLOW METER MUST REMAIN OPERABLE AT 58 GPM +/- 4% DUE TO PIPE AND FILTER RESTRICTIONS
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Skimmers had an accumulation of debris. All cleaned by operator during the inspection.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Lifesaving equipment includes body hook and pole and USCG approved ring buoy with required rope length. Rope not attached to ring buoy. New rope was provided at correct length during inspection. CDI
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Items within 6 ft of pool. Operator moved and corrected. No permit action.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(d) Pump room floor shall be kept dry and free of standing water. Floor of pump room around chlorinator was observed wet.
Mar 19, 2026 16 demerits · 4 violations
Inspector comments: Inspection conducted with CPOs Tony and Richard
All out of compliance items were corrected during the inspection with the exception of standing water in the pump room. Shown to operators.
Drain covers and equalizer covers EXPIRE 3/24/2026. An updated PDSC form shall be submitted, approved and approved covers installed by this date. Non compliance will result in immediate permit suspension. Spoke with Tony and Richard about this deadline.
Const. Date: 8/2/2016 Rope Length: 19' No night swimming PERMIT RESTRICTION - FLOW METER MUST REMAIN OPERABLE AT 58 GPM +/- 4% DUE TO PIPE AND FILTER RESTRICTIONS.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Pool water pH 8.0. Corrected to 7.7 during inspection.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Skimmers had an accumulation of debris. All cleaned by operator during the inspection.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Lounger too close to pool corner. Operator moved and corrected. No permit action.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. Bucket of chlorine tabs were observed in the pump room. Moved to chemical storage room during the inspection by operator.
.2533(d) Pump room floor shall be kept dry and free of standing water. Floor of pump room around chlorinator was observed wet.
Oct 1, 2025 20 demerits · 6 violations
Inspector comments: Performed inspection with new CPO Tony and EHS Kurtis. Intent to suspend issued for records, missing fitting, and lack of spare pump basket. Items must be corrected within 30 days or permit may be suspended. Call Devon when corrected 7049981122
Drain covers and equalizer covers EXPIRE 3/24/2026
Const. Date: 8/2/2016
Rope Length: 19'
No night swimming
PERMIT RESTRICTION -
FLOW METER MUST
REMAIN OPERABLE AT 58
GPM +/- 4% DUE TO PIPE
AND FILTER
RESTRICTIONS.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
No records since mid August. Intent to suspend item.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs.
Weir in skimmer by tables missing. Operator corrected and re installed. No permit action.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
.2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair.
Fitting missing on pipe by 4ft depth marker by wall. Replace. Intent to suspend item.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(e) Provide a spare basket for pump.
Spare pump basket missing. Provide new pump basket. No permit action.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
.2526(h) Shower(s) shall be provided. Shower not working.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(j) Provide soap and soap dispenser, no glass, at each sink.
No soap at sink. Provide soap.
Apr 22, 2025 16 demerits · 4 violations
Inspector comments: Conducted inspection with CPO Tony Morris. Intent to suspend issued for lack of records. Text EHS Devon when corrected 7049981122
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
No records since February. Intent to suspend item.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed one of the 2 buoys present with one rope length exceeding 20’. Shortened to 19’ during inspection. No permit action.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Lounger too close to pool corner. Operator moved and corrected. No permit action.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
.2526(h) Shower(s) shall be provided. Shower not working.
Sep 5, 2024 12 demerits · 4 violations
Inspector comments: Inspection conducted with CPO Tony Morris. Pool remains in good standing and on A status.
Note: Pool depth FT tile near handicap lift lifting from deck. Correct before tile is offset 1/2in.
#18 · Premises: lifeguards present or warning signs posted −4
.2530(c) Provide "Children should not use the swimming pool without adult supervision." in 1" lettering.
.2530(c) Provide "Adults should not swim alone." in 1" lettering.
Sign missing with above verbiage. New sign on order. Operator corrected by reposting old sign.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(e) Provide a spare basket for pump. Spare pump basket missing. New one on order. No permit action.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
.2526(h) Shower(s) shall be provided. Shower not working. Parts to fix on order.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(l) Provide toilet paper and dispensers in restrooms. No toilet paper in restroom.
Apr 3, 2024 4 demerits · 1 violation
Inspector comments: Performed inspection with CPO Tony Morris, Donald Moten, Raj Desai, and Bianca Desai. Intent to suspend issued for fence gate not self closing self latching. Contact Devon Moeller when gate is repaired 7049981122
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing, self-latching. Fence gate on far side of pool not self closing self latching. Intent to suspend item.
Sep 5, 2023 14 demerits · 3 violations
Inspector comments: Inspection conducted with operator Angel. All permit items corrected during inspection. Night swimming is not permitted.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Missing some CYA readings. No permit action. Ensure both TA and CYA readings are documented at least weekly.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Tables and chairs within 6’ of pool. Operator corrected. Note: there is only 6’ of clearance between pool and hotel wall. No furnishings should be placed in this area.
#22 · Premises: emergency telephone provided −6
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Emergency phone call back number posted as 704-398-2919. Charlotte 911 provided call back number of 704-398-7025. EHS confirmed this number calls back pool phone directly. Posted call back number updated.
Feb 21, 2023 26 demerits · 6 violations
Inspector comments: Inspection conducted with Angel Rivera-Delcon. Intent to suspend issued due to the following items:
Far gate and main hotel entry door do not latch closed, missing vacuum port cover, and missing/incomplete record keeping. Repair door and gate to fully self-close and latch, replace missing vacuum port cover, and maintain records as required. EHS will return within 30 days to evaluate. If all items are not in compliance, permit will be suspended. Call Hope McIntosh at 980-229-7549 with questions.
Night swimming not permitted.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Pool water pH 8.0. Corrected to 7.4 during inspection.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Observed no records maintained during months of Dec and Jan. Operator indicated pool was closed but not noted on any record. Records resume Feb ‘23 missing weekend ph and cl readings. No main drain checks documented.
Intent to suspend items
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed one of the 2 buoys present with rope length exceeding 20’. Shortened to 19’ during inspection.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing, self-latching. Main door entry from hotel does not latch when closed and does not have audible alarm. Card reader/lock is not working and operator noted they leave the door unlocked until 9pm.
Gate at far end of pool not latching closed every time. Some breeze present but not sufficient to prevent gate from operating normally, Operator noted that spring cannot be tensioned any tighter. Repair to ensure full closure and latch every time.
Intent to suspend items
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(f) Provide a vacuum cap or self-closing cap for pools built after May 1, 2010. No cap on vacuum line port on pool wall. Pool built 2016. Locking cover missing. Replace.
Intent to suspend item
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor. Bag of dry chemicals stored directly on chemical room floor.
Jul 12, 2022 0 demerits · 0 violations
Inspector comments: Inspection completed with Rodney Searcy present.
In-field plan review completed.
1. Flow = 60 GPM
2. Pump verified to be PENTAIR INTELLIFLO VSF 011056
3. Main drain pipe diameter = 2.5 inches; skimmer = 2.5 inches; return = 2 inches
4. (2) Aquastar 914xxx drain covers installed and verified
5. (2) waterway 640-9210 equalizer line covers installed and verified
6. PENTAIR TR 160 Filter verified and installed
7. Observed 4 total returns on pool wall
8. 2 skimmers verified today
No violations were recorded for this inspection.
Oct 1, 2021 16 demerits · 3 violations
Inspector comments: Inspection completed with Raj Desai and Edward Sofronovici present. No signature due to COVID.
Permit suspended due to damaged rope connected to ring buoy. Contact Eli Freese at 704.621.2298 once rope is replaced to reopen pool.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Observed pH at 8.2. CDI- corrected to 7.2.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Observed no records being kept. Hotel operator indicated the pool was closed. No signs were posted at pool entryways to indicate the pool as being closed.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed damaged rope connected to ring buoy. Permit suspended.
Apr 29, 2021 0 demerits · 0 violations
Inspector comments: Inspection completed with Raj Desai. No signature due to COVID-19.
No violations were recorded for this inspection.
Jul 28, 2020 6 demerits · 1 violation
Inspector comments: On-site inspection completed with Sofia Daya and Jackie Hooks. Bonding wire has been reconnected since last visit. No signature due to COVID-19.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Observed pH at 7.0. CDI- adjusted to 7.2.
Oct 25, 2019 4 demerits · 1 violation
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed lounge chair with in 6 feet of pools edge. Corrected on site.
Apr 17, 2019 2 demerits · 1 violation
Inspector comments: #8. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Small amount of debris found in skimmers during inspection. Pool operator cleaned debris from skimmers.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up. Bags of Chlorine found on floor of chemical room. Store chemicals in bags off the floor.
Nov 7, 2018 14 demerits · 3 violations
Inspector comments: 5) Salt pool. Currently no cyanuric acid in the swimming pool. Recommend having some cyanuric acid in the pool to stabilize the chlorine, especially in the summer when water temperature is higher and the pool is in the sun more. Operator will be using stabilized chlorine when water gets too cold to use salt generator.
5) A few days in a row of pH 7.9 with no corrective actions taken. Maintain proper water chemistry and document pool maintenance activities such as chemicals added, backwashing, etc.
#3 · Water quality: pool water pH −6
.2535(1) pH 8.2. Maintain between 7.2 and 7.8. Corrected to 7.3.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Operator on vacation for a week, no records for November. No Cyanuric Acid records. Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, and pool water maintenance. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Maintain cyanuric acid at no more than 100ppm. Operator tested chemicals.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(f) Vacuum on in pump room. Vacuum cap not closed in pool. Provide a vacuum cap or self-closing cap for pools built after May 1, 2010. Corrected by operator.
May 17, 2018 6 demerits · 2 violations
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed main gate not latching properly. CDI gate made to latch properly.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed slow leak from pipe in pump room.
Jun 6, 2017 34 demerits · 7 violations
Inspector comments: Post a copy of the permit in the pool area.
Immediate suspension issued.
3)
22)
#3 · Water quality: pool water pH −6
pH 8.2. Maintain between 7.2 and 7.8. - Immediate suspension item.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Inadequate record keeping. Observed only Cl and pH checks. Check daily Cl, pH, and main drains. Check at least weekly TA and CYA. - Intent to suspend item.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
One throw rope too long. Corrected by operator. Recommend storing the ring buoys opposite sides of the pool deck.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
One gate standing open. Maintain gates self-closing and self-latching. Corrected.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Maintain proper deck clearance. Many of the tables, chairs, trash can, etc too close to pool edge. Maintain at least 6 feet clear walkway around the pool. For some parts of the pool this will mean there is no room for any furniture. - Intent to suspend item.
#22 · Premises: emergency telephone provided −6
Emergency phone not functioning. Goes to front desk, but unable to hear front desk.
Emergency phone shall be on a dedicated line to 911. Provide correct dialing instructions and correct address and phone number should be posted at the emergency phone. - Immediate suspension item.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Pressure guage on filter 30 psi. Backwash pool regularly. Operator backwashed and pressure guage went back to 10 psi.
Aug 19, 2016 2 demerits · 1 violation
Inspector comments: Observed all issues noted on construction inspection have been corrected.
Permit will be issued online at Meckpools.Charmeck.org in 3-5 business days.
Print a copy to post in the pool area.
Permit issued with the following conditions.
No night swimming.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
No soap in restroom. Provide soap. Corrected by operator.
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “HOME 2 SUITES BY HILTON CLT AIRPORT” or State ID 2060530371). Inspection type (routine vs. follow-up) is not published in the county's data.