‹ Back to search

18demerits

HOME 2 SUITES

625 MCCULLOUGH DR, Charlotte, NC 28262
Year-Round Swimming Pool · NC permit/State ID 2060530374
Latest result18 demerits
Last inspectedAug 26, 2026
Inspections on record19
On record sinceNov 8, 2016

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

01428 Nov 8, 2016: 2Apr 11, 2017: 6Sep 14, 2017: 20Feb 22, 2018: 10Nov 8, 2018: 28May 14, 2019: 0Dec 17, 2019: 26Jan 15, 2020: 6Jun 24, 2021: 4Oct 21, 2021: 10May 19, 2022: 0Oct 5, 2022: 8Jan 9, 2023: 12Feb 28, 2024: 0Nov 14, 2024: 12Jan 7, 2025: 16Nov 12, 2025: 18Jan 8, 2026: 18Aug 26, 2026: 18
Nov 8, 2016Lower is betterAug 26, 2026

Inspections & violations

Aug 26, 2026 18 demerits · 4 violations
#2 · Water quality: disinfectant residual provided by −6
Observed chlorine at 0.5ppm. Maintain at minimum of 1.0ppm. Adjusted onsite to 2.0 ppm
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed one skimmer basket broken. Replace. .2518(k) Replace missing or damaged skimmer basket.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed ladder missing end cap. Replace. .2521 Install ladders per manufacturer instructions.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed two ring buoys not USCG approved and with throw ropes longer and shorter than 22.5 feet. Corrected onsite. .2530(a) Lifesaving equipment includes body hook and pole and USCG approved ring buoy with required rope length. .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less.

View this inspection on the county portal ›

Jan 8, 2026 18 demerits · 4 violations
Inspector comments: Issued immediate suspension for .2535- chlorine and .2535- water temperature. Pool is to remain closed until these items are corrected. Please call James Bjorneboe at 704-507-6820 or main office at 980-314-1620 to schedule reinspection.
#2 · Water quality: disinfectant residual provided by −6
Observed chlorine less that 1.0ppm. Maintain chlorine at a minimum of 1.0ppm .2535(4) Maintain chlorine at least 1.0 ppm.
#4 · Water quality: water temperature of heated pool −6
Observed water temp of pool at 98.5 degrees. Pool water shall not exceed 90 degrees. .2535(12) Maintain pool temperature at 90 F or below.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Observed no daily or weekly written records for January. Keep records as required. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed broken rung on pool ladder. Repair. .2521 Install ladders per manufacturer instructions.

View this inspection on the county portal ›

Nov 12, 2025 18 demerits · 5 violations
Inspector comments: Issued immediate suspension for no chlorine in pool. Pool is to remain closed until chlorine levels are at required levels. Please call James Bjorneboe at 704-507-6820 or main switch board at 980-314-1620 to schedule reinspection. General comment: Observed fading on depth markers on pool wall. Consider cleaning or replacing as needed. Inspection conducted by Niejel Wilkins.
#2 · Water quality: disinfectant residual provided by −6
Observed no chlorine in pool. Maintain chlorine at 1.0ppm .2535(4) Maintain chlorine at least 1.0 ppm.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Observed no weekly records for total alkalinity and daily records for main drain checks. Keep records as required. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed 1 skimmer basked cracked and in poor repair. Replace. .2518(k) Replace missing or damaged skimmer basket.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed inoperable ventilation in pump. Repair. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Observed hot water in restrooms at 117 degrees. Hot water should not exceed 110 in restrooms. .2526(i) Water in restrooms shall not exceed 110 F.

View this inspection on the county portal ›

Jan 7, 2025 16 demerits · 3 violations
Inspector comments: Issued immediate suspension for water temperature. Pool must remain closed until pool water is at or below 90 degrees. Call James Bjorneboe at 704-507-6820 once items are corrected to schedule a re-visit.
#4 · Water quality: water temperature of heated pool −6
Observed water in pool at 101 degrees. Hot water should not exceed 90 degrees in pool. .2535(12) Maintain pool temperature at 90 F or below.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed 1 weir disconnected. Corrected on site. .2518(k) Replace missing weirs.
#22 · Premises: emergency telephone provided −6
Incorrect phone number posted at emergency phone. Corrected onsite. .2530(f) Emergency notification systems must provide 24 hr. monitoring, be capable of routing calls to 911, and be able to electronically transfer Automatic Number and Locator Identification for the phone.

View this inspection on the county portal ›

Nov 14, 2024 12 demerits · 3 violations
Inspector comments: Issued Immediate suspension for inoperable emergency phone. Pool must remain closed until emergency phone is fixed. Once the emergency phone is fixed, please call James Bjorneboe at 704-507-6820 to schedule reinspection prior to pool reopening. General Comment: Observed minor chipping on one area of pool wall. Monitor area to ensure chipping does not get worse.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Observed no daily written records for November. Keep and maintain daily written records as required. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
#22 · Premises: emergency telephone provided −6
Emergency phone was inoperable at time of inspection. Ensure that emergency phone remains operable at all times. .2530(f) Emergency phone shall remain operable.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Observed hot water in restrooms at 110 degrees. Hot water should not exceed 110 degrees in restrooms. .2526(i) Water in restrooms shall not exceed 110 F.

View this inspection on the county portal ›

Feb 28, 2024 0 demerits · 0 violations
Inspector comments: No violations observed during inspection. New main drain cover installed match PDSC form. Permit reinstated.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Jan 9, 2023 12 demerits · 3 violations
Inspector comments: Issued Immediate suspension for pH at 8.2. Call James Bjorneboe at 704-507-6820 once pH is back within allowable range.
#3 · Water quality: pool water pH −6
Observed pH at 8.1. Maintain pH between 7.2-7.8. .2535(1) Maintain pH at 7.2 to 7.8.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed 1 of 2 weirs missing. Corrected on site.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Observed sink missing in restroom. Replace missing sink. Additional men’s and womens restroom located in hall way between lobby and pool. Restrooms are less than 75 feet away.

View this inspection on the county portal ›

Oct 5, 2022 8 demerits · 2 violations
Inspector comments: Issued intent to suspend for missing weirs. Call when weirs are replaced. James Bjorneboe: 704-507-6820.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed both skimmers missing weirs. Replace missing weirs. .2518(k) Replace missing weirs.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed planets within 5 feet of pools edge. Maintain 5 feet of clearance at all points. .2522(b) Provide at least 5 ft of clear walking space around the pool at all times.

View this inspection on the county portal ›

May 19, 2022 0 demerits · 0 violations
Inspector comments: No violations observed at time of inspection. Issued permit sticker on site.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Oct 21, 2021 10 demerits · 3 violations
Inspector comments: Pool records get emailed to hotel manager daily. Advised manager to have records on hand when inspections take place.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed minor debris in skimmers. Keep skimmers free of debris. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed deck chairs and planters with in five feet of pools edge. Maintain 5 feet of clearance at all points. .2522(b) Provide at least 5 ft of clear walking space around the pool at all times.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Observed bathroom door locked at time of visit. Keep bathroom door unlocked when pool is open. Corrected on site.

View this inspection on the county portal ›

Jun 24, 2021 4 demerits · 1 violation
Inspector comments: Local permit issued. Equalizers must be changed by August. Please submit a new, completed PDSC form with new equalizer information to this office by August 1. PDSC form can be found at Meckpools.charmeck.org.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational.

View this inspection on the county portal ›

Jan 15, 2020 6 demerits · 1 violation
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed throw rope at 20.5 feet. Adjusted to 22 feet onsite. Throw rope must remain at 22 feet.

View this inspection on the county portal ›

Dec 17, 2019 26 demerits · 7 violations
Inspector comments: New Eco Lab cal hypo automatic feeder installed. Ensure that chemical feeder was installed correctly and any applicable plumbing/electrical permits were pulled. Escutcheon plate missing on handrail. Recommend installing a new escutcheon plate to prevent injury or tampering with the screw for the handrail anchor. Pump, bonding wires, and other equipment heavily rusted from leaks in the pump room. Maintain everything in good operating condition. Intent to suspend issued. 5) 8) 16)
#5 · Water quality: daily written records of water quality and test kit kept on site −4
No records kept on CPO's off days. Missing daily main drain and temperature checks. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature. Provide weekly recordings for total alkalinity and cyanuric acid if used. - Intent to suspend item.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Both weirs missing. .2518(k) Replace missing weirs. - Intent to suspend item.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Throw rope for one of the ring buoys 5 feet too short. .2530(a) Provide 22 foot throw rope for U. S. Coast Guard approved ring buoy. - Corrected.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Door to patio area sticks, not self-latching. .2537(b) All gates and doors shall be self-closing, self-latching. - Intent to suspend item.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter stuck. .2518(g) Keep flow meter operational. - Corrected by operator.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Leak in the pump room. .2533(d) Pump room floor shall be kept dry and free of standing water. Acid tub stored in the pump room for newly installed Eco Lab chemical feeder. Store all chemicals in the chemical storage room.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Hot water in restroom 112.5F. .2526(i) Water in restrooms shall not exceed 110 F.

View this inspection on the county portal ›

May 14, 2019 0 demerits · 0 violations
Inspector comments: 11) Escutcheon on handrail missing. Install handrails securely per manufacturer's instructions. 22) Recommend installing bolts on body hook such that bolt head is facing the hook portion of the body hook, reducing the chance of injuring the person being rescued. Permit will be issued at Meckpools.Charmeck. org in 3-5 business days. Please print a copy to post in the pool area. The permit sticker should be coming in the mail in 1-2 weeks. Please post in the pool area.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Nov 8, 2018 28 demerits · 7 violations
Inspector comments: Tiles dirty. Clean regularly. Pump motor recently changed out. New motor not bonded to the pool. Need to obtain electrical permits from Code Enforcement and get a passing electrical inspection. Intent to suspend issued. 5)
#1 · Water quality: water clear enough to clearly see bottom of pool and pool drain −6
.2535(2) Water cloudy and with foam on top of the pool. Main drains must be clearly visible from the pool deck. Corrected.
#3 · Water quality: pool water pH −6
.2535(1) pH > 8.4. Maintain pH at 7.2 to 7.8. Corrected to 7.7.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) No records for the last few months. Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. - Intent to suspend item. .2535 (4) No recent cyanuric acid checks. Maintain cyanuric acid at or below 100 ppm. - Intent to suspend item.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Throw ropes not attached to the ring buoys. Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. - Corrected by operator.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(d) Leak at pump. Pump room floor shall be kept dry and free of standing water. .2534(4) Bag of chemicals on floor. Provide storage for pool chemicals in waterproof containers or store up off the floor. - Corrected by operator. .2534(2) Chemicals stored in the pump room. Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. - Corrected by operator.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
.2526(a) Restroom door locked. Provide at least one sink and toilet for residents and guests if furthest unit is more than 300 feet from the pool at hotels, motels, condominiums and apartments.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2626(i) Hot water > 110F. Water in restrooms shall not exceed 110 F.

View this inspection on the county portal ›

Feb 22, 2018 10 demerits · 2 violations
Inspector comments: Note: new pump motor replaced. Still has the same pump. Spa heater down. Ensure that when heater is fixed water temperature is maintained at no more than 90F. Intent to suspend issued. 8)
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Both weirs missing. Install functional weirs. - Intent to suspend item.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
One ring buoy with loose beckets, both ring buoys with ropes not attached. Provide US Coast Guard approved ring buoy with 22 foot throw rope. Corrected by operator.

View this inspection on the county portal ›

Sep 14, 2017 20 demerits · 5 violations
Inspector comments: Move tables from in front of emergency phone to allow easier access. Corrected by operator.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Missing one weir. Install functional weirs. Corrected by operator.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
One ring buoy throw rope 23.5 feet long. Provide 22 foot throw rope for ring buoy. Corrected by operator.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Trash can too close to pool. Maintain at least 5 feet deck clearance around pool, ladders and handrails. Corrected by operator.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Provide spare pump basket for pool pump.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Sink faucet loose. Maintain secure and in good condition. Hot water 116F. Maintain at 110F or less.

View this inspection on the county portal ›

Apr 11, 2017 6 demerits · 2 violations
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed deck items closer than five feet from pool edge. Keep items at least 5 foot back from pool water at indoor pool.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Observed hot water at fitting on sink to be 114F. Hot water for bathrooms and showers should be 110F or less for pools.

View this inspection on the county portal ›

Nov 8, 2016 2 demerits · 1 violation
Inspector comments: Permit issued.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Hot water 112F. Maintain at 110F or less. Corrected to 88F.

View this inspection on the county portal ›

Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “HOME 2 SUITES” or State ID 2060530374). Inspection type (routine vs. follow-up) is not published in the county's data.