‹ Back to search

10demerits

WILDWOOD APARTMENTS

1022 FOREST OAK DRIVE, Charlotte, NC 28209
Year-Round Swimming Pool · NC permit/State ID 2060530377
Latest result10 demerits
Last inspectedJun 24, 2026
Inspections on record18
On record sinceJun 27, 2017

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

02142 Jun 27, 2017: 12Nov 22, 2017: 14Apr 26, 2018: 14Dec 7, 2018: 10Apr 3, 2019: 16Sep 25, 2019: 12Jun 9, 2020: 18Aug 26, 2020: 16Apr 13, 2021: 42Jun 9, 2021: 12Oct 13, 2021: 10May 25, 2022: 16Sep 13, 2022: 16Mar 30, 2023: 24Sep 12, 2023: 22May 6, 2024: 14Jul 2, 2025: 24Jun 24, 2026: 10
Jun 27, 2017Lower is betterJun 24, 2026

Inspections & violations

Jun 24, 2026 10 demerits · 4 violations
Inspector comments: Conducted inspection with CPO. EHS recommends lowering chlorine for bather comfort. Pool permit issued and pool returned to A status. Permit Restriction: Flow meter must remain operable. Flow required at least 105 gpm to 141 gpm to meet turnover and flow restriction of the filter. Flow shall not exceed 150 gpm due to drain cover flow restriction. Suction Hazard. Const. Date: 7/1/1982 Rope Length: 30' Night Swim?: N
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Brick wall and other parts of fencing creating horizontals (handholds/footholds) less than 45" in height. Maintain horizontals no less than 45" in height. Pool built '92, no permit action.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Chemicals stored in pump room. Items within 3' of piping. Pool built '92. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
#27 · Equipment room: filter backwash discharged through an air gap −2
No air gap at backwash. Pool built 1992. .2513(b) Filter backwash shall be discharged through an air gap
#33 · Dressing and sanitary facilities: hose bibbs and floor drains provided −2
No floor drains in restroom. No hose bib in restroom within 50’ Pool built ‘92. .2526(c) Floor drains shall be provided in restrooms. .2526(d) Provide hose bib so that all parts of restroom can be reached with a 50 ft hose.

View this inspection on the county portal ›

Jul 2, 2025 24 demerits · 7 violations
Inspector comments: Inspection conducted with CPO Killian. Permit may be issued and pool may open. Submit updated PDSC to the health department when ready to unplug the equalizers. See notes below. Const. Date: 7/1/1982 Rope Length: 30' No night swimming Verified the following during the inspection: Flow meter must remain operable. Flow required at least 105 gpm to 141 gpm to meet turnover and flow restriction of the filter. Flow shall not exceed 150 gpm due to drain cover flow restriction. Suction Hazard. VERIFIED 120GPM New Pump Pentair Intelliflo3 VSF 011077, 3 hp pump VERIFIED Blue white flow meter reading the above permit restriction. REMOVED AND REPLACED Main drain, skimmer and return line all 3” line coming out of the pump room floor. VERIFIED (2) Aquastar 1216xxx 2017 drain covers. VERIFIED (1) Pentair TR140C filter VERIFIED 10 returns VERIFIED 6 FLOOR 4 WALL 4 skimmers with EQ lines plugged per State requirement. EQUALIZERS HAD BEEN UNPLUGGED AND NEW SDX2 RETRO INSTALLED - INFORMATION NOT APPROVED OR REFLECTED ON THE PDSC. OPERATOR PLUGGED EQUALIZERS TO OPEN POOL UNTIL NEW EQUALIZERS ARE APPROVED. NO SUCTION HAZARD WHILE PLUGGED.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
.2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance. Equalizers covers installed without documentation from PDSC. Operator re plugged equalizers on the inside and outside to maintain suction safety until new equalizer covers can be approved by Health Department. No permit action.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Rope for ring buoy greater than 30’. Corrected during inspection. No permit action.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Brick wall and other parts of fencing creating horizontals (handholds/footholds) less than 45" in height. Maintain horizontals no less than 45" in height. Pool built '92, no permit action.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Chemicals stored in pump room. Items within 3' of piping. Pool built '92. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
#27 · Equipment room: filter backwash discharged through an air gap −2
No air gap at backwash. Pool built 1992. .2513(b) Filter backwash shall be discharged through an air gap
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
.2526(h) Shower(s) shall be provided. Shower not provided
#33 · Dressing and sanitary facilities: hose bibbs and floor drains provided −2
No floor drains in restroom. No hose bib in restroom within 50’ Pool built ‘92. .2526(c) Floor drains shall be provided in restrooms. .2526(d) Provide hose bib so that all parts of restroom can be reached with a 50 ft hose.

View this inspection on the county portal ›

May 6, 2024 14 demerits · 5 violations
Inspector comments: Conducted inspection with CPO Killian. 30 day intent to suspend issued for missing deck no diving and depth marker. Contact Devon when corrected 7049981122
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
"No Diving" marker and depth marker missing creating distance greater than 25 ft apart from other markers on deck surface. .2523(d) The distance between no diving markers shall be no more than 25 feet perimeter or as the crow flies. .2523(d) No Diving markers shall be provided in all areas of the pool less than five feet deep. .2523(d) No Diving markers shall be written in four inch letters or international 6"x6" no diving in red and black on a white background. .2523(a) Provide depth markers on pool walls and pool deck next to the swimming pool. .2523(b) Provide depth markers spaced not to exceed 25 feet when measured along the perimeter of the pool. .2523(c) Depth markers shall be 4 inches in height and of a contrasting color with the background, clearly visible.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
No spare pump basket available. Pump Pentair Challenger CHII-NI-3F. New pump basket on order. No permit action. .2518(e) Provide a spare basket for pump.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Chemicals stored in pump room. Items within 3' of piping. Pool built '92. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
#27 · Equipment room: filter backwash discharged through an air gap −2
No air gap at backwash. Pool built 1992. .2513(b) Filter backwash shall be discharged through an air gap
#33 · Dressing and sanitary facilities: hose bibbs and floor drains provided −2
No floor drains in restroom. No hose bib in restroom within 50’ Pool built ‘92. .2526(c) Floor drains shall be provided in restrooms. .2526(d) Provide hose bib so that all parts of restroom can be reached with a 50 ft hose.

View this inspection on the county portal ›

Sep 12, 2023 22 demerits · 7 violations
Inspector comments: Inspection conducted with operator Killian. All permit items in compliance by end of inspection. Night swimming is not permitted.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
Depth markers at various areas of pool deck and on sides of pool at coping with some cracking. Operator noted they are planning on re-decking and re-surfacing pool spring 2024. Repair or replace cracked depth markers prior to permit issuance in 2024. No permit action at this time.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Rope for ring buoy greater than 30’. Corrected during inspection
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Brick wall and other parts of fencing creating horizontals (handholds/footholds) less than 45" in height. Gaps under fencing greater than 4" in some areas on hill. Maintain horizontals no less than 45" in height. Pool built '92, no permit action. Ensure windows onto pool deck do not open greater than 4" (unable to verify). .2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010). .
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Chemicals stored in pump room. Items within 3' of piping. Pool built '92. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
#26 · Equipment room: valves and pipes identified by color codes or labels −2
Labels fading piping .2518(d) Piping and valves shall be labeled with color codes or labels.
#27 · Equipment room: filter backwash discharged through an air gap −2
No air gap at backwash. Pool built 1992. .2513(b) Filter backwash shall be discharged through an air gap
#33 · Dressing and sanitary facilities: hose bibbs and floor drains provided −2
No floor drains in restroom. No hose bib in restroom within 50’ Pool built ‘92. .2526(c) Floor drains shall be provided in restrooms. .2526(d) Provide hose bib so that all parts of restroom can be reached with a 50 ft hose.

View this inspection on the county portal ›

Mar 30, 2023 24 demerits · 7 violations
Inspector comments: Inspection conducted with operator, Killian. Emergency phone not fully operating as intended - operator unable to fully hear communications unless yelled through box. EHS will return within 30 days to verify phone has been repaired and is able to properly communicate with 911 dispatch. Once corrected, call Hope McIntosh at 980-229-7549 to request a re-visit. Night swimming not approved. Note: Decking around pool continues to settle with cracking present. Repairs have been conducted, however, some decking offsets approaching 1/2 inch limit observed during inspection. Ensure no decking offsets are present that exceed 1/2 inch which could present trip hazards.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Pool water pH 8.0. Corrected to 7.4 during inspection.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Brick wall and other parts of fencing creating horizontals (handholds/footholds) less than 45" in height. Gaps under fencing greater than 4" in some areas on hill. Maintain horizontals no less than 45" in height. Pool built '92, no permit action. Ensure windows onto pool deck do not open greater than 4" (unable to verify). .2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010). Door to clubhouse leads directly onto pool deck and cannot be propped open. Remove door stop to as door should never be propped open.
#22 · Premises: emergency telephone provided −6
.2530(f) Emergency phone shall remain operable. Emergency call box not operating as designed/intended. Box dials 911, however, operator unable to clearly hear communication. EHS attempted to call two times - first time 911 disconnected as they could not hear. The second call EHS yelled directly into box and operator confirmed barely able to hear but did confirm location information. Similar issue was noted with previous inspection in September of 2022. Should there be an actual emergency, 911 operations would likely not be able to communicate. 30 day intent to suspend the permit issued.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Chemicals stored in pump room. Items within 3' of piping. Pool built '92. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
#26 · Equipment room: valves and pipes identified by color codes or labels −2
Labels fading piping .2518(d) Piping and valves shall be labeled with color codes or labels.
#27 · Equipment room: filter backwash discharged through an air gap −2
No air gap at backwash. Pool built 1992. .2513(b) Filter backwash shall be discharged through an air gap
#33 · Dressing and sanitary facilities: hose bibbs and floor drains provided −2
No floor drains in restroom. No hose bib in restroom within 50’ Pool built ‘92. .2526(c) Floor drains shall be provided in restrooms. .2526(d) Provide hose bib so that all parts of restroom can be reached with a 50 ft hose.

View this inspection on the county portal ›

Sep 13, 2022 16 demerits · 5 violations
Inspector comments: Operator at emergency phone stated it was hard to hear. Advised to correct for clarity before problem worsens/phone deemed inoperable. 30 Day ITS for deck offsets and gates self-closing, self-latching.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Bottle and debris in skimmer. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Operator emptied and corrected.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Brick wall and other parts of fencing creating horizontals (handholds/footholds) less than 45" in height. Gaps under fencing greater than 4" in some areas on hill. Maintain horizontals no less than 45" in height. Pool built '92, no permit action. Ensure windows onto pool deck do not open greater than 4" (unable to verify). .2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010). Gate not self-closing, self-latching at time of inspection. .2537(b) All gates and doors shall be self-closing, self-latching. *ITS item
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Deck cracking in back right corner by 3 1/2 FT greater than 1/2”, maintain less than 1/2" offset, 6’ around pool. Chairs within 5’ not handrails. .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. .2522(e) Provide at least 5 ft of clear walking space around diving board, handrail, slide, or other permanent structure on a swimming pool deck. *ITS item
#27 · Equipment room: filter backwash discharged through an air gap −2
No air gap at backwash. Pool built 1992. .2513(b) Filter backwash shall be discharged through an air gap
#33 · Dressing and sanitary facilities: hose bibbs and floor drains provided −2
No floor drains in restroom. No hose bib in restroom within 50’ Pool built ‘92. .2526(c) Floor drains shall be provided in restrooms. .2526(d) Provide hose bib so that all parts of restroom can be reached with a 50 ft hose.

View this inspection on the county portal ›

May 25, 2022 16 demerits · 6 violations
Inspector comments: Issued local permit sticker. Verified PDSC information: Pentair Challenger CHII-NI-3F, 3 HP (missing placard on pump, unchanged) 2 Aquastar 1216 (VGBA 2017), 4 Paramount SDX 2 skimmer equalizer covers Contrasting color bands have been corrected No Night Swimming “A” Open for Business
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Brick wall and other parts of fencing creating horizontals (handholds/footholds) less than 45" in height. Gaps under fencing greater than 4" in some areas on hill. Maintain horizontals no less than 45" in height. Pool built '92, no permit action. Ensure windows onto pool deck do not open greater than 4" (unable to verify). .2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010). *Note: Discussed removing plex-glass from gates. Plexi-glass is on gates because of horizontal (metal pice on side) less than 45” in height. Gate latches are all at least 54” in height. Gate is at least 48” in height, top horizontal is 45”.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Coping/bricks loose and coming out around pool at 4 FT depth marker. Deck cracking in back right corner, maintain less than 1/2" offset. Operator filled with caulk. Corrected. Advised monitoring deck for repairs. Chair within 5' of handrail. Operator moved and corrected. .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. .2522(e) Provide at least 5 ft of clear walking space around diving board, handrail, slide, or other permanent structure on a swimming pool deck.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Chemicals stored in pump room. Items within 3' of piping. Pool built '92. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
#26 · Equipment room: valves and pipes identified by color codes or labels −2
Labels fading piping .2518(d) Piping and valves shall be labeled with color codes or labels.
#27 · Equipment room: filter backwash discharged through an air gap −2
No air gap at backwash. Pool built 1992. .2513(b) Filter backwash shall be discharged through an air gap
#33 · Dressing and sanitary facilities: hose bibbs and floor drains provided −2
No floor drains in restroom. No hose bib in restroom within 50’ Pool built ‘92. .2526(c) Floor drains shall be provided in restrooms. .2526(d) Provide hose bib so that all parts of restroom can be reached with a 50 ft hose.

View this inspection on the county portal ›

Oct 13, 2021 10 demerits · 4 violations
Inspector comments: General comment: Deck starting to crack by 4 FT corner. Not 1/2" offset yet. Does not warrant permit action, but advised sealing before it worsens. Main drains and skimmer equalizer covers expire April 2022, replace and submit updated PDSC for approval prior to expiration to avoid permit action. Contrasting color bands must be repaired prior to 2022 permit. Inspection with Killian Lane No signature due to COVID Pool not heated. No Night Swimming
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Brick wall and other parts of fencing creating horizontals (handholds/footholds) less than 45" in height. Gaps under fencing greater than 4" in some areas on hill. Maintain horizontals no less than 45" in height. Pool built '92, no permit action. Ensure windows onto pool deck do not open greater than 4" (unable to verify). .2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010).
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Chemicals stored in pump room. Items within 3' of piping. Pool built '92. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
#26 · Equipment room: valves and pipes identified by color codes or labels −2
Labels no longer visible on main drain piping .2518(d) Piping and valves shall be labeled with color codes or labels. Operator labeled and corrected.
#27 · Equipment room: filter backwash discharged through an air gap −2
No air gap at backwash. Pool built 1992. .2513(b) Filter backwash shall be discharged through an air gap

View this inspection on the county portal ›

Jun 9, 2021 12 demerits · 4 violations
Inspector comments: Visit to pool to lift Immediate Suspension and conduct pre-permit inspection for pool. Lifted Immediate Suspension for emergency phone and water quality. Chlorinator now working properly. Motor change has obtained permit on file for electrical work 5/21/21 E3879771. Records, loose coping, signage and chlorinator have been corrected since last inspection. Issued permit. Changed to "A" Open for Business. No Night Swimming. Note: main drains expire April 2022. Replace and submit updated PDSC for approval prior to expiration to avoid permit action. Contrasting color bands on stairs must be corrected by April 2022 for permit next year. Pool not heated. No signature due to COVID-19. Inspection with: Killian Lane Report to: wildwoodchl.mgr@ram-mgt.com
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
"No Diving" marker missing at 5 FT creating distance greater than 25 ft apart from other markers. .2523(d) The distance between no diving markers shall be no more than 25 feet perimeter or as the crow flies. .2523(d) No Diving markers shall be provided in all areas of the pool less than five feet deep. .2523(d) No Diving markers shall be written in four inch letters or international 6"x6" no diving in red and black on a white background. Operator stenciled "No Diving" in greater than 4" lettering on deck. Corrected.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Brick wall and other parts of fencing creating horizontals (handholds/footholds) less than 45" in height. Gaps under fencing greater than 4" in some areas on hill. Maintain horizontals no less than 45" in height. Pool built '92, no permit action. Ensure windows onto pool deck do not open greater than 4" (unable to verify). .2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010).
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Chemicals stored in pump room. Items within 3' of piping. Pool built '92. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. No hose bib on pool deck or in restrooms. .2533(g) Provide a hose bib with backflow prevention device within 50 ft. of the equipment room.
#27 · Equipment room: filter backwash discharged through an air gap −2
No air gap at backwash. Pool built prior to 2010, 1992. .2513(b) Filter backwash shall be discharged through an air gap

View this inspection on the county portal ›

Apr 13, 2021 42 demerits · 11 violations
Inspector comments: Immediate Suspension issued for emergency phone and water quality (chlorinator not working properly). Contact Marie Daley at 704-507-6806 when in compliance to lift suspension. Pool MUST REMAIN CLOSED with signage posted until suspension is lifted by Health Dept. Permit items include: Motor change observed with no permit on file for electrical work. New permit will not be issued until electrical permit is pulled for work done. Records, loose coping, signage and chlorinator not working properly. Note main drains expire April 2022. Replace and submit updated PDSC for approval prior to expiration to avoid permit action. Contrasting color bands on stairs must be corrected by April 2022 for permit next year. Changed to "E" Immediate Suspension status. Pool not heated. No Night Swimming. No signature due to COVID-19. Inspection with: Killian Lane Report to: Manager Wildwood
#2 · Water quality: disinfectant residual provided by −6
Chlorine 0.6 ppm at time of inspection. Chlorinator not working properly. .2535(4) Maintain chlorine at least 1.0 ppm. **Immediate Suspension item. Pool must remain closed until this item is in compliance. Contact Marie Daley at 704-507-6806 when in compliance (chlorine raised through chlorinator, not hand fed) to lift suspension.**
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Records missing weekly total alkalinity and cyanuric acid. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. *Permit item
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Entry railing into pool loose. Keep tightened and in good repair. .2521 Install ladders per manufacturer instructions.
#13 · Pool maintenance: contrasting band on steps and benches −4
Contrasting color bands starting to fade on edges of stairs into pool. .2521(b) Provide at least 2" contrasting color band to edge of stair treads. .2521(b) Contrasting color band shall be clearly visible. *Allowed until 2022 for correction of this item, due to lack of severity. Permit will not be issued in 2022 if this item is not corrected.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Brick wall and other parts of fencing creating horizontals (handholds/footholds) less than 45" in height. Maintain horizontals no less than 45" in height. Pool built '92, no permit action. Ensure windows onto pool deck do not open greater than 4" (unable to verify).
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Coping/bricks loose and coming out around pool at 4 FT depth marker. Deck cracking in back right corner, maintain less than 1/2" offset. .2537(3) There shall be no loose coping. **Permit item Chairs and pool furniture within 6' of pool. .2522(a) Provide 6 ft of clear walking space around the pool at all times. Operator moved and corrected. .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile.
#18 · Premises: lifeguards present or warning signs posted −4
Required signage not posted at time of inspection. .2530(c) Provide "Children should not use the swimming pool without adult supervision." in 1" lettering. .2530(c) All pool signage shall be visible upon entrance to the pool and permanently affixed. **Permit item
#22 · Premises: emergency telephone provided −6
Emergency phone not operable at time of inspection. .2530(f) Emergency phone shall remain operable. **Immediate Suspension item. Pool must remain closed until suspension lifted by Health Dept.**
#23 · Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 −4
Chlorinator not working properly to maintain levels at time of inspection. .2535(6) Provide NSF approved automatic chlorinator installed per manufacturer instructions. *permit item
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Chemicals stored in pump room. Items within 3' of piping. Dry chemicals over liquid chemicals. Pool built '92. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. .2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up.
#27 · Equipment room: filter backwash discharged through an air gap −2
No air gap at backwash. Pool built prior to 2010, 1992. .2513(b) Filter backwash shall be discharged through an air gap

View this inspection on the county portal ›

Aug 26, 2020 16 demerits · 6 violations
Inspector comments: ITS for gates, doors and spare pump basket. Contact Marie Daley at 704-507-6806 when in compliance to lift ITS. Changed to "W" status. No signature due to COVID-19. Inspection with: Killian Lane Report to: Manager Wildwood
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Entry railing into pool loose. Keep tightened and in good repair.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Side gate locked because it is not latching. Main gate not self-latching. Door from restrooms onto pool deck not latching or alarmed. .2537(b) All gates and doors shall be self-closing, self-latching. .2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. *30 Day Intent to Suspend (ITS) item. Contact Marie Daley at 704-507-6806 when in compliance to lift ITS. Brick wall and other parts of fencing creating horizontals (handholds/footholds) less than 45" in height. Maintain horizontals no less then 45" in height. Pool built '92, no permit action.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
No spare pump basket available. Pump Pentair Challenger CHII-NI-3F. .2518(e) Provide a spare basket for pump. *30 Day ITS item.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Chemicals stored in pump room. Items within 3' of piping. Dry chemicals over liquid chemicals. Pump room open at time of inspection, with no operator present. Pool built '92. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. .2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up. .2533(a) The equipment room door shall have a permanent lock and be kept locked when not in use by the pool operator.
#27 · Equipment room: filter backwash discharged through an air gap −2
No air gap at backwash. Pool built prior to 2010, 1992. .2513(b) Filter backwash shall be discharged through an air gap.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
No soap in men's restroom at time of inspection. .2526(j) Provide soap and soap dispenser, no glass, at each sink. Operator filled with soap. Corrected.

View this inspection on the county portal ›

Jun 9, 2020 18 demerits · 6 violations
Inspector comments: Issued local permit sticker. Changed to "A" Open for Business, valid permit, with condition following Executive Orders for COVID-19 and safety precautions outlined in permit. Night Swimming NOT permitted. Operator unable to sign due to COVID-19 protocol and safety precautions to not share equipment. Inspection completed with: Killian Lane Sent report to: wildwoodchl.mgr@ram-mgt.com
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Brick wall and other parts of fencing creating horizontals (handholds/footholds) less than 45" in height. Bottom of fence broken in one area, creating gap greater than 4" at bottom. Pool built '92, no permit action. .2528(a) Provide no openings in fence and/or gate greater than 4"x4". .2528(b) Horizontals shall not be located less than 45" in height. *Note: Ensure windows onto pool deck from resident apartments do not open greater than 4" or have audible alarm. Did not verify at time of inspection.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Two bricks not secure, loose at time of inspection. .2537(3) There shall be no loose coping. Operator got supplies to secure brick coping. Corrected.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed flow meter stuck. .2518(g) Keep flow meter operational. Operator adjusted and corrected.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Chemicals stored in pump room. Items within 3' of piping. Pool built '92. .2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
#26 · Equipment room: valves and pipes identified by color codes or labels −2
Labels no longer visible on some piping .2518(d) Piping and valves shall be labeled with color codes or labels. Operator labeled and corrected.
#27 · Equipment room: filter backwash discharged through an air gap −2
No air gap at backwash. Pool built '92. .2513(b) Filter backwash shall be discharged through an air gap.

View this inspection on the county portal ›

Sep 25, 2019 12 demerits · 3 violations
#3 · Water quality: pool water pH −6
Observed pH to be 6.8. pH must be 7.2-7.8 for safety. I.S. Issued, pool closed.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Observed log book to not have any entries since July 13th 2019. The daily checks (pH, Chlorine, Main Drain/EQ Covers checks) must be done every day the pool is open. Cyanuric Acid (if in use) and Total Alkalinity must be checked once a week. These checks must be done. Pool is currently closed. When pool is opened it will be given a 30 day deadline for record keeping. Records must be properly kept everyday or pool will be closed for failure to keep records properly.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed ladder to be missing the rubber feet. Replace them.

View this inspection on the county portal ›

Apr 3, 2019 16 demerits · 4 violations
Inspector comments: Intent to Suspend the Permit has been issued. The thirty day deadline ends on 5/3/19. Contact C. Elmore when corrections are made at 704-507-6814.
#3 · Water quality: pool water pH −6
Observed pH to be 7.0. pH was raised to 7.2. -C.D.I.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Observed log book to be unavailable. Daily and weekly checks must be done and recorded. pH, chlorine, and main drains/EQ covers must be checked every day. Total Alkalinity and Cyauric Acid must be checked at least once a week. I.T.S. issued.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed rubber feet missing from ladder. Replace the feet.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed footholds at the fence. Pool was built prior to 2010. No permit action taken. Gates have footholds less than 45" from the ground, including signs, metal bars, and at least 1 hinge that exceeds the 2" limit. The footholds for the gates must be corrected. I.T.S. Issued.

View this inspection on the county portal ›

Dec 7, 2018 10 demerits · 3 violations
#5 · Water quality: daily written records of water quality and test kit kept on site −4
OBSERVED GAPS IN THE LOG BOOK. EVERY DAY THE POOL IS OPEN CHECK AND RECORD CHLORINE, pH, MAIN DRAIN/EQ COVERS. CHECK AND RECORD TOTAL ALKALINITY ONCE A WEEK.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
OBSERVED LADDER MISSING RUBBER FEET.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
FENCE BUILT PRIOR 2010. OBSERVED SOME FOOTHOLDS PRESENT. NO PERMIT ACTION TAKEN AT THIS TIME.

View this inspection on the county portal ›

Apr 26, 2018 14 demerits · 5 violations
Inspector comments: VGB and PDSC information verified.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed debris on floor of pool. Vacuum pool to eliminate debris build up.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed deck chairs less than 6 feet from edge of pool. Corrected during inspection by moving chairs to required distance.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed chemicals stord on floor of chemical storage room.
#27 · Equipment room: filter backwash discharged through an air gap −2
Observed no air gap on back wash discharge.
#33 · Dressing and sanitary facilities: hose bibbs and floor drains provided −2
Observed no hose bibs in bathrooms.

View this inspection on the county portal ›

Nov 22, 2017 14 demerits · 4 violations
Inspector comments: Intent to suspend issued for pool gates and damaged skimmer lid. Please contact Chris Sells when repairs have been completed or for questions at 704 576 8678 Pool will be closed in 30 days by the Department if intent to suspend items are not corrected. PDSC information verified
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed tile on wall dirty. Keep pool walls clean.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed 2 gates not self closing, the gate entering the apartment walk way and the gateopening from the pool level to the parking lot. Gates must be self closing self latching. **Intent to suspend
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed skimmer cover cracked and weak. Replace skimmer cover. **Intent to suspend
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed chemicals stored in pump room. Do not store chemicals in pump room.

View this inspection on the county portal ›

Jun 27, 2017 12 demerits · 3 violations
#3 · Water quality: pool water pH −6
Observed pH measuring at 7.0-7.1. CPO adjusted and inspector was able to get a reading of 7.2-7.3 before departure. Maintain pH between 7.2-7.8 at all times.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed step hand rail loose. Maintain all ladder and step hand rails tight.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter was observed stuck on the bottom. Maintain properly functioning flow meter.

View this inspection on the county portal ›

Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “WILDWOOD APARTMENTS” or State ID 2060530377). Inspection type (routine vs. follow-up) is not published in the county's data.