MURRAY, THE

8010 WOODSEDGE DR, Charlotte, NC 28216
Year-Round Swimming Pool · NC permit/State ID 2060530459
Latest result8 demerits
Last inspectedMay 4, 2026
Inspections on record17
On record sinceMay 24, 2018

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

01428 May 24, 2018: 10Apr 26, 2019: 8Jul 30, 2019: 26Jun 10, 2020: 16Sep 23, 2020: 24Apr 19, 2021: 10Aug 10, 2021: 16Apr 4, 2022: 18Jul 19, 2022: 16May 16, 2023: 28Jun 1, 2023: 4Jul 27, 2023: 22Apr 29, 2024: 18Jul 31, 2024: 8Apr 21, 2025: 12Sep 16, 2025: 12May 4, 2026: 8
May 24, 2018Lower is betterMay 4, 2026

Inspections & violations

May 4, 2026 8 demerits · 3 violations
Inspector comments: Inspection conducted with CPO Henry Ramirez. Throw rope starting to fray. Recommend replacing with new 41 foot throw rope at least 1/4 inches in diameter.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Pre-2010 fence with footholds at grill area. .2528(b) Horizontals shall not be located less than 45" in height. Pre-2010 fence. Most fence sections < 48" high. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Lights burned out in the pump room. .2533(b) Provide sufficient lighting in pump room.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Toilet paper holder damaged in one of the restrooms. .2526(l) Provide toilet paper and dispensers in restrooms.

View this inspection on the county portal ›

Sep 16, 2025 12 demerits · 3 violations
Inspector comments: Inspection conducted with maintenance staff Eligio Queliz. No diving marker cracked. Maintain in good condition. Throw rope fraying, outer rope on ring buoy starting to fray. Recommend replacing with new US Coast Guard approved ring buoy with attached 41 foot throw rope at least 1/4 inches in diameter.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Ring buoy outer rope all on one side. Throw rope fraying and heavily knotted. .2530(a) Provide USCG approved ring buoy with attached 41 foot throw rope. - Corrected.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Pre-2010 fence with footholds at grill area. .2528(b) Horizontals shall not be located less than 45" in height. Pre-2010 fence. Most fence sections < 48" high. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Lights burned out in the pump room. .2533(b) Provide sufficient lighting in pump room. Fan not working in pump room. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room. Fan not working in chemical storage room. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room.

View this inspection on the county portal ›

Apr 21, 2025 12 demerits · 4 violations
Inspector comments: Inspection conducted with CPO Henry Ramirez.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Missing some weekends. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. - Corrected. Operator now has weekend coverage.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Pre-2010 fence with footholds at grill area. .2528(b) Horizontals shall not be located less than 45" in height. Pre-2010 fence. Most fence sections < 48" high. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Lights burned out in the pump room. .2533(b) Provide sufficient lighting in pump room.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
One restroom locked. .2526(a) Provide restrooms at all pools except for hotels, motels, condominiums and apartments where pool use is restricted to guests and residents.

View this inspection on the county portal ›

Jul 31, 2024 8 demerits · 3 violations
Inspector comments: Inspection conducted with inspectors Hope McIntosh, Jeremy Michael, and CPO Henry Ramirez.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Pre-2010 fence with footholds at grill area. .2528(b) Horizontals shall not be located less than 45" in height. Pre-2010 fence. Some fence sections < 48" high. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
One light burned out, one light very dim in pump room. .2533(b) Provide sufficient lighting in pump room.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Toilet paper holders damaged in the restrooms. .2526(l) Provide toilet paper and dispensers in restrooms.

View this inspection on the county portal ›

Apr 29, 2024 18 demerits · 5 violations
Inspector comments: Inspection conducted with CPO Henry Ramirez. Flow meter worn, bobber sticks. Recommend replacing. Ensure new flow meter is installed per manufacturer’s instructions, flow meter is capable of reading 1.5x design flow, and is capable of reading within +/- 10% of true flow.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Ring buoy damaged. .2530(a) Provide USCG approved ring buoy with attached 41 foot throw rope. - Corrected. New ring buoy provided.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Pre-2010 fence with footholds at grill area. .2528(b) Horizontals shall not be located less than 45" in height. Pre-2010 fence. Some fence sections < 48" high. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
One chair too close to pool edge. .2522(a) Provide 6 feet of clear walking space around the pool at all times. - Corrected.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
One light burned out, one light very dim in pump room. .2533(b) Provide sufficient lighting in pump room.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Toilet paper holders damaged in the restrooms. .2526(l) Provide toilet paper and dispensers in restrooms.

View this inspection on the county portal ›

Jul 27, 2023 22 demerits · 5 violations
Inspector comments: Inspection conducted with CPO Henry Ramirez. Recommend recalibrating chemical controller. Tested Cl > 10ppm free chlorine, controller read 507 ORP, pH tested at 7.0, reading 7.4. Intent to suspend issued 5)
#3 · Water quality: pool water pH −6
PH 7.0. .2535(1) Maintain pH at 7.2 to 7.8. - Corrected to 7.2.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Operator unable to locate log book. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. - Intent to suspend item. No log book on site. .2535(11) The pool operator must maintain records for at least six months. - Intent to suspend item.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Throw rope 32.5 ft long, tangled around ring buoy. .2530(a) Provide USCG approved ring buoy with attached 41 foot throw rope. - Corrected.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Pre-2010 fence with footholds at grill area. .2528(b) Horizontals shall not be located less than 45" in height. Pre-2010 fence. Some fence sections < 48" high. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. Gate latch broken. .2528(a) Access gates shall swing away from the pool and be self-latching, self-closing. - Corrected.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Leak in the pump room. .2533(d) Pump room floor shall be kept dry and free of standing water. Fan turned off in the chemical storage room. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room. - Corrected. One light burned out, other light mostly out, periodically flickers. .2533(b) Provide sufficient lighting in pump room.

View this inspection on the county portal ›

Jun 1, 2023 4 demerits · 1 violation
Inspector comments: Inspection conducted with CPO Henry Ramirez. Issues from previous pre-permit inspection corrected. Verified PDSC information. Electronic gate disabled, using Magna-Latch. If using an electronic latch ensure no footholds < 45” high and operate on a battery backup. Permit issued No Night Swimming Paper permit will be available on our website https://health.mecknc.gov/envhealth/pools in 3-5 business days for your records.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Pre-2010 fence with footholds at grill area. .2528(b) Horizontals shall not be located less than 45" in height.

View this inspection on the county portal ›

May 16, 2023 28 demerits · 6 violations
Inspector comments: Inspection conducted with CPO Henry Ramirez. Note* Pool recently replastered. Sumps were changed from 18x18 to 9x9. Will need to provide updated PDSC form to our office as well as in-field plan review application. Paperwork is available at our website https://health.mecknc.gov/envhealth/pools Observed 3x VGB2017 Aquastar 9x9 main drain covers and 1x VGB2008 Aquastar 9x9 main drain cover. Ensure all main drain covers are the same. Magnetic latch for gate removed. If ever reinstalled, ensure it is at least 45” high so it does not create a foothold and operates on a battery backup. Verified that glass tables on pool deck are tempered glass. Pre-permit inspection did not pass 3) 6) 24) There is a $100 re-inspection fee that must be paid prior to scheduling a re-inspection by calling our office (980-314-1620) and paying with a credit card.
#3 · Water quality: pool water pH −6
PH 7.1. .2535(1) Maintain pH at 7.2 to 7.8. - Pre-permit item.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
Pool recently replastered. Changed from 18x18 main drains to 9x9 main drains. .2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance. Will need to go through in-field plan review as well. - Pre-permit item.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
New ring buoy with 60 foot throw rope. .2530(a) Provide USCG approved ring buoy with attached 41 foot throw rope. - Corrected.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Pre-2010 fence. Decorative rocks added around the fence < 48" high throughout. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. Magna-Latch < 54” high. .2528(a) Gate latches shall be 54" in height. - Corrected.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Pool recently replastered. Eyeball fitting installed on one of the vacuum lines. .2518(f) Provide a vacuum cap or self-closing cap for pools built after May 1, 2010. - Pre-permit item.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Fan not working in chemical storage room. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room.

View this inspection on the county portal ›

Jul 19, 2022 16 demerits · 3 violations
Inspector comments: Inspection conducted with inspector Pompacert Vongvilay and CPO Drew Schroder.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Throw rope not attached to ring buoy. .2530(a) Provide USCG approved ring buoy with attached 41 foot throw rope. - Corrected.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Pre-2010 fence. Some fence sections < 48" high. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. Double door to the office, sliding bolt not engaged, allowing both doors to open and not properly close and latch. .2537(b) All gates and doors shall be self-closing, self-latching. - Corrected.
#22 · Premises: emergency telephone provided −6
Unable to call back to Kings III call box, goes to fax machine. .2530(f) Emergency phone shall remain operable and be capable of accepting incoming calls. - Corrected.

View this inspection on the county portal ›

Apr 4, 2022 18 demerits · 4 violations
Inspector comments: Inspection conducted with CPO Drew Schroder. Technical difficulties prevented CPO from signing inspection. Permit sticker will be mailed out in the coming weeks. Please place sticker in an easily viewable location in the pool area.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Throw rope 47 feet long. .2530(a) Provide USCG approved ring buoy with attached 41 foot throw rope. - Corrected.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Pre-2010 fence. Some fence sections < 48" high. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier.
#22 · Premises: emergency telephone provided −6
Unable to call back to Kings III call box, goes to fax machine. .2530(f) Emergency phone shall remain operable and be capable of accepting incoming calls. - Corrected.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
No soap in the restroom. .2526(j) Provide soap and soap dispenser, no glass, at each sink.

View this inspection on the county portal ›

Aug 10, 2021 16 demerits · 4 violations
Inspector comments: Inspection conducted with Drew Schroder. Due to COVID-19 precautions, inspection was not signed by the operator. Some beckets loose on ring buoy, throw rope starting to fray. Recommend replacing with a new US Coast Guard approved ring buoy and 41 ft throw rope before next pool season. Throw rope needs to be at least 1/4" in diameter. Operator has been getting 5ppm free chlorine with test strips. My DPD test today read 0ppm free chlorine, with some combined chlorine. Recommend using DPD or other, more accurate test kit to test pool water chemistry.
#2 · Water quality: disinfectant residual provided by −6
No free chlorine in the pool. .2535(4) Maintain chlorine at least 1.0 ppm. - Corrected to 2.5 ppm.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Pre-2010 fence. Some fence sections < 48" high. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Some chairs too close to pool edge. .2522(a) Provide 6 feet of clear walking space around the pool at all times. - Corrected.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
No soap in the restroom. .2526(j) Provide soap and soap dispenser, no glass, at each sink.

View this inspection on the county portal ›

Apr 19, 2021 10 demerits · 4 violations
Inspector comments: Inspection conducted with CPO Drew Schroder . Due to COVID-19 precautions, inspection was not signed by the operator. Intent to suspend issued 16 Call Will Harrison (704-507-6824) for reinspection when issue has been corrected. “Executive Order No. 141 or subsequent Orders are in effect unless such Orders are rescinded or superseded by another applicable Order.”
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Pre-2010 fence. Some fence sections < 48" high. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. Section of fence not anchored to office wall. .2528 Ensure fencing is securely installed. Windows from the office onto the pool deck capable of opening > 4". .2528(a) Ground level windows shall not open greater than 4" on to pool deck or child protected by audible alarm. - Intent to suspend item.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Fan not working in the pump room. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room.
#26 · Equipment room: valves and pipes identified by color codes or labels −2
New plumbing in the pump room not labeled. .2518(d) Piping and valves shall be labeled with color codes or labels.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
One of the restrooms closed for repairs. .2526(a) Provide restrooms in good condition.

View this inspection on the county portal ›

Sep 23, 2020 24 demerits · 7 violations
Inspector comments: Inspection conducted. Due to COVID-19 precautions, inspection was not signed by office staff. Observed main gate has been welded in the past, these welds have broken, damaging the integrity of the gate and creating cut hazards. G.S. 130A-2(3) Eliminate cut hazards and provide a functional gate meeting requirements. Ring buoy and throw rope heavily worn. Recommend replacing with a new US Coast Guard approved ring buoy and 41 foot throw rope. Rope shall be at least 1/4" in diameter. Observed gaps between deck drain sections. Maintain deck with no gaps or offsets > 1/2". “Executive Order No. 141 or subsequent Orders are in effect unless such Orders are rescinded or superseded by another applicable Order.” Intent to suspend issued 5) 8) 17) 18) Main gate damaged
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Records not being kept. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. - Intent to suspend item. Most of the test kit reagents expired. Unable to find in date reagents for all required tests. Recommend disposing of expired reagents. .2535(10) Provide test kit capable of measuring disinfectant level, cyanuric acid and total alkalinity. - Intent to suspend item. Pool not currently maintained by a Certified Pool Operator. .2537(c) Pool owner shall provide for the operation and maintenance of the pool by a trained pool operator. - Intent to suspend item.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Skimmers with leaves and debris. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Intent to suspend item.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Pre-2010 fence < 48 inches high in places. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. Pre-2010 fence with footholds. .2528(b) Horizontals shall not be located less than 45" in height.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Some chairs too close to pool edge. .2522(a) Provide 6 feet of clear walking space around the pool at all times. - Intent to suspend item.
#18 · Premises: lifeguards present or warning signs posted −4
WARNING - NO LIFEGUARD ON DUTY sign heavily faded. .2530(c) Provide new, easily readable "Warning - No Lifeguard on Duty" in 4" lettering. - Intent to suspend item.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Leak in the pump room. .2533(d) Pump room floor shall be kept dry and free of standing water. Chemicals stored in the pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
Restrooms locked until repairs are made in the restrooms. .2526(a) Provide at least one sink and toilet for residents and guests if furthest unit is more than 300 feet from the pool at hotels, motels, condominiums and apartments.

View this inspection on the county portal ›

Jun 10, 2020 16 demerits · 5 violations
Inspector comments: OSV. Pool open and in use. Pool does not have a current permit. Prior to opening the pool ensure that pool has a valid permit posted in the pool area such that bathers can readily see the permit. Inspection conducted with Drew Schroder. Due to COVID-19 precautions, inspection was not signed by the operator. Filter pressure high, pump basket half full of leaves and debris. Regularly clean pump basket and backwash per manufacturer's recommendations. Main gate sometimes doesn't self-close if opened all the way. Ensure that gate is self-closing and self-latching. WARNING-NO LIFEGUARD ON DUTY sign faded. Recommend replacing with a new sign in at least 4" lettering. Permit issued. No Night Swimming. “Issuance of a permit by this department does not negate closure required by Executive Order No. 120 or subsequent Orders in effect unless such Orders are rescinded or superseded by another applicable Order.”
#5 · Water quality: daily written records of water quality and test kit kept on site −4
No recent TA or CYA checks. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, and pool water maintenance. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Operator tested both while onsite.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Some fence sections < 48" high. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter stuck. .2518(g) Keep flow meter operational.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Light burned out in the chemical storage room. .2534(6) Provide sufficient lighting in chemical storage room. Corrected by operator.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
No toilet paper holder for toilet paper in the restroom. .2526(l) Provide toilet paper and dispensers in restrooms. Hot water > 110F. .2526(i) Water in restrooms shall not exceed 110 F. No soap in the restroom. .2526(j) Provide soap and soap dispenser, no glass, at each sink.

View this inspection on the county portal ›

Jul 30, 2019 26 demerits · 7 violations
Inspector comments: Some gaps between sections of the deck drains. Maintain deck with no gaps or offsets > 1/2 inch. Intent to suspend issued. 5) 8) 24)
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Spotty recent records. Only have part of July. No checks on weekends, no CYA checks. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, and pool water maintenance. Provide weekly recordings for cyanuric acid and total alkalinity weekly. - Intent to suspend item.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Missing both weirs. .2518(k) Replace missing weirs. - Intent to suspend item.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Ring buoy too long. Corrected by operator to 41 feet.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Fence pre-2010. Large sections of fence < 48" high. .2528(a) Pool gate shall be at least 48" in height measured from outside of barrier.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Spare pump basket broken. .2518(e) Provide a spare basket for pump. - Intent to suspend item. Flow meter stuck. .2518(g) Keep flow meter operational. - Intent to suspend item.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Chemicals stored in the pump room. Store all chemicals in the chemical storage room.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Hot water > 110F. .2626(i) Water in restrooms shall not exceed 110 F. No soap in the restrooms. .2626(j) Provide soap and soap dispenser at each sink. No toilet paper in the restrooms. .2626(l) Provide toilet paper and dispensers in restrooms. Restrooms locked. Provide access to the restrooms when the pool is open.

View this inspection on the county portal ›

Apr 26, 2019 8 demerits · 2 violations
Inspector comments: Timothy Rankin and Sharron Brown present during inspection. Fence repair from last year (one additional vertical member near gate) remains intact. Facility states they plan to replace fence this year. Reminded to them that they should check with Health Department for up-to-date fence and gate requirements before making decisions regarding design, construction, and purchase. Night swimming not allowed. Current operating hours are sunrise to sunset.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Skimmer baskets full of leaf debris. Cleaned during inspection.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. Observed four screws protruding from deck where anchored table had been removed. CPO removed screws during inspection.

View this inspection on the county portal ›

May 24, 2018 10 demerits · 2 violations
Inspector comments: Annual pool. Permit issued. Night swimming not allowed. Local permit number 18-60 0262 (sticker).
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Record book missing column for daily drain cover checks. Column added. CPO agreed to begin recording daily checks.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Rope measured 48' Required length 41'. Rope shortened during inspection to required length of 41'.

View this inspection on the county portal ›