GREENSIDE APARTMENTS
1315 HARDING PLACE, Charlotte, NC 28204
Year-Round Swimming Pool · NC permit/State ID 2060530481
Latest result20 demerits
Last inspectedSep 30, 2026
Inspections on record16
On record sinceOct 19, 2018
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Oct 19, 2018Lower is betterSep 30, 2026
Inspections & violations
Sep 30, 2026 20 demerits · 6 violations
Inspector comments: Issued 30 Day Intent to Suspend (ITS) for doors onto pool deck, water level and bubblers/fittings in good repair. Contact Marie Daley at 704-507-6806 when in compliance to lift ITS.
“W” ITS status
Motors on pumps have been replaced. Unsure of replacement timeline. Ensure electrical permits pulled. Housing missing on feature pump, see note in file.
Salt is not approved as primary chlorination. Portable vacuum.
Inspection with Orlin Aguirre
Pool heater not on. No night swimming.
Did not check all windows onto pool deck from personal resident rooms due to privacy. Ensure windows do not open more than 4” onto pool deck.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Records missing weekly cyanuric acid readings.
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable.
Operator explained readings not in correct location on form, changed location and corrected.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Pool water level below skimmers at time of inspection, .2518(k) Water level shall be maintained to assure skimmers are operable. Pool was drained to make repairs on sunshelf.
*permit item
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
Bubbler fitting on sunshelf loose, not secure at time of inspection. Company to repair fittings onsite for repair. .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair.
*permit item
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Door onto pool deck catching, not latching at time of inspection.
.2528(a) Ground level doors shall be self-closing, self-latching or self-closing and child protected by audible alarm.
*permit item
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Leak at backwash bit. Pump room floor wet, holding water. Chemicals and storage in pump room.
.2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
.2533(d) Pump room floor shall be kept dry and free of standing water.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Women’s restroom toilet soiled.
.2526(m) Keep restrooms and fixtures clean and in good repair.
May 19, 2026 12 demerits · 3 violations
Inspector comments: Inspection completed with David McElveen and Orlin Aguirre present.
Note- ring buoy throw rope was too long. CDI- cut to 37 feet 6 inches.
Provide portable vacuum to pool cleaning.
Intent to suspend permit for items listed below. Correct within 30 days or permit will be suspended. The current permit is valid until 5/31/2026. If the intent to suspend items are not corrected by then, a new permit cannot be issued. Once corrected, contact Eli Freese at 704.621.2298 to verify and lift intent to suspend.
1. Doors from clubhouse and grotto not self-latching and/or self-closing.
2. Windows that lead from apartments directly to pool deck not alarmed or limited to open 4 inches or less.
3. Cracked skimmer basket.
4. One loose depth tile and one loose ‘FT’ tile.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing or damaged skimmer basket. Observed one cracked skimmer basket. Intent to suspend permit issued.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
.2523(a) Provide depth markers on pool walls and pool deck next to the swimming pool. Observed one depth tile and one ‘FT’ tile detached from pool deck and loose. Re-secure. Intent to suspend permit issued.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing, self-latching. Observed doors leading from club house to pool deck not self-latching. Observed door at ‘grotto’ area not self-closing or self-latching. Correct within 30 days. Intent to suspend permit issued.
.2528(a) Ground level windows shall not open greater than 4" on to pool deck or child protected by audible alarm. Observed windows from apartments that lead directly onto pool deck not limited to opening greater than 4 inches. Intent to suspend permit issued.
Mar 3, 2025 0 demerits · 0 violations
Inspector comments: NO VIOLATIONS NOTED
Observed broken glass from small alcohol bottles to be present inside the pool enclosure. Glass was removed. Ensure that glass is excluded from the pool enclosure. Broken glass is a hazard and could result in a closure of the pool.
Observed 1.25 HP motor replaced on the WFE-3 filtration pump. Electrical permit was verified with MCHD supervision.
Previous pump housing for the XFE-12 is present, previously used for the bubbler pump. Pump impeller system is the XFE-12, only the housing was changed.
Pool main drains will expire 2/1/2028.
No violations were recorded for this inspection.
Aug 5, 2024 8 demerits · 2 violations
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
Observed gaps in the log book record. Ensure that proper daily and weekly checks are made and recorded. This must be done every day the pool is open.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed pool furniture too close to the pool edge. Items were moved. Corrected during inspection. Ensure 6 ft. Clear space around the pool at all times.
Apr 16, 2024 12 demerits · 3 violations
Inspector comments: POOL IS CLOSED BY ORDER OF THE HEALTH DEPARTMENT. CONTACT C. ELMORE WHEN THE ITEMS ARE CORRECTED.
704-507-6814. POOL CANNOT REOPEN WITHOUT HEALTH DEPARTMENT VERIFICATION.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
.2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair.
Observed bubbler fitting to be missing the top cover, leaving a hole in the sun shelf where it presents an injury hazard to bathers on the sun shelf. The sun shelf is intended to provide walking area and this hole is an imminent hazard to people walking on the sun shelf. This must be covered with a cover appropriate for use in the pool.
I.S. Issued.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Double doors to the pool area are not fully self-closing and self-latching. One closing will block the other from fully closing and this is happening with both doors. Correct the doors so that they are fully self-closing and fully-self latching.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed pool furniture too close to the pool edge. Items were moved. Corrected during inspection. Ensure 6 ft. Clear space around the pool at all times.
Oct 19, 2023 10 demerits · 2 violations
Inspector comments: Pump motor for WFE-3 pump was swapped out. A 1.25 THP motor was installed in place of the old 3/4 HP motor. Operator reports an electrical inspection and permit were obtained for the motor replacement.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Observed pH to be 8.2 upon arrival. Corrected to 7.8 during inspection.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed pool furniture too close to the pool edge. Items were moved. Corrected during inspection. Ensure 6 ft. Clear space around the pool at all times.
Feb 23, 2023 0 demerits · 0 violations
Inspector comments: Observed main drains for feature and filtration to be swapped out. Mecklenburg Health Department has not yet received the PDSC form for approval from the vendor. C. Elmore spoke to the vendor and they advised they were working on the PDSC form to send to MCHD. The pool may remain open with the feature pump off until the PDSC form is approved by MCHD. C. Elmore will follow-up on or around 2/09/2023 to verify PDSC compliance.
The pump motor for the XFE-12 was swapped out. A electrical permit was issued, but the inspection has not been completed according to the County records available to MCHD. This must be completed prior to 5/1/2023 or a new operation permit will not be issued.
No violations were recorded for this inspection.
Oct 24, 2022 0 demerits · 0 violations
Inspector comments: NO VIOLATIONS NOTED.
MAIN DRAIN COVERS WILL NEED TO BE REPLACED AND THE PDSC PAPERWORK SUBMITTED TO AND APPROVED BY THE HEALTH DEPARTMENT BEFORE THE END OF AUGUST 2023.
CURRENT COVERS ARE AQUASTAR 1216XXX AND PARAMOUNT SDX RETROS, 4 COVERS TOTAL.
No violations were recorded for this inspection.
Mar 24, 2022 0 demerits · 0 violations
Inspector comments: NO VIOLATIONS NOTED
CPO AGREED TO EMAIL OF THE REPORT
POOL HAS 2 PARAMOUNT SDX RETRO MAIN DRAIN COVERS AND 2 AQUASTAR 1216 MAIN DRAIN COVERS.
THESE ALL EXPIRE AUGUST 2023. WHEN THESE ITEMS ARE REPLACED, PDSC PAPERWORK WILL
HAVE TO BE SUBMITTED TO THE HEALTH DEPARTMENT FOR APPROVAL.
No violations were recorded for this inspection.
Oct 21, 2021 0 demerits · 0 violations
Inspector comments: NO VIOLATIONS NOTED.
STAFF AGREED TO EMAIL COPY OF REPORT
NO SIGNATURE DUE TO COVID-19 PRECAUTIONS.
CONTINUE TO FOLLOW ALL RELEVANT COVID RULES
No violations were recorded for this inspection.
Mar 4, 2021 8 demerits · 2 violations
Inspector comments: “issuance of a permit by this department does not negate closure required by Executive Order No. 120, 138, 141, 147, or subsequent Orders in effect unless such Orders are rescinded or superseded by another applicable Order.”
NO SIGNATURE WAS OBTAINED DUE TO COVID-19 SOCIAL DISTANCING
CPO agreed to email of report form.
Observed housing of the feature pump (XFE-12) was replaced with a housing for a different pump (Intelliflo XF VS). The pool contractor was contacted and agreed to send a statement that only the housing was changed, that the internals are the same so no actual pump change was made.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
Observed cracked fill fitting. Fitting must be replaced. I.T.S. Issued. Deadline is 4/3/2021. Contact C. Elmore when fitting is corrected. 704-507-6814.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed doors to not fully self close and self latch. Doors were corrected -CDI.
Oct 7, 2020 0 demerits · 0 violations
Inspector comments: NO VIOLATIONS NOTED.
“issuance of a permit by this department does not negate closure required by Executive Order No. 120, 138, 141, 147, or subsequent Orders in effect unless such Orders are rescinded or superseded by another applicable Order.”
NO SIGNATURE WAS OBTAINED DUE TO COVID-19 SOCIAL DISTANCING
POOL IS NOT APPROVED FOR NIGHT SWIMMING. IF NIGHT SWIMMING IS DESIRED, A NIGHT SWIMMING EVALUATION MUST BE PERFORMED. CONTACT C. ELMORE AT 704-507-6814 FOR THIS EVALUATION IF NIGHT SWIMMING IS DESIRED.
No violations were recorded for this inspection.
Apr 9, 2020 0 demerits · 0 violations
Inspector comments: NO VIOLATIONS NOTED, POOL HAS PASSED INSPECTION.
PERMIT AND STICKER WILL BE ISSUED AT LATER TIME
POOL DOES NOT ALLOW NIGHT SWIMMING . IF NIGHT SWIMMING IS TO BE ALLOWED, A NIGHT SWIMMING EVALUATION MUST BE PERFORMED. CONTACT C. ELMORE AT 704-507-6814 IF THIS IS DESIRED.
Issuance of a permit by this department does not negate closure required by Executive Order No. 120 or subsequent Orders in effect unless such Orders are rescinded or superseded by another applicable Order.
NO SIGNATURE OBTAINED SO THAT COVID-19 SOCIAL DISTANCING CAN BE OBSERVED
No violations were recorded for this inspection.
Sep 24, 2019 24 demerits · 7 violations
Inspector comments: 15 - General Comment - Rope length at 36.5 ft. Required at 37.5 ft., if replaced.
General Comment - Lights installed on pool deck that overhang grill area and cornhole area. No glass permitted on pool deck. Eliminate lights if not shatterproof or provide documentaiton that lights are shatterproof within 30 days.
Intent to suspend issued for record keeping, test kit, light to wall, flow meter, doors and windows.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Cyanuric acid and total alkalinity not recorded weekly. Record weekly. Intent to Suspend issued.
Test kit with expired chemicals. Provide test kit. Intent to Suspend issued.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Light not flush to pool wall near handicap lift. Repair to eliminate pinch hazard. Intent to Suspend issued.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Double door into club room not self-latching. Repair doors to self-close, self-latch. Intent to Suspend issued.
Window limiters removed from some windows on to pool deck. Repair limiters so that windows are permanently affixed at 4". Intent to Suspend issued.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Some pool furniture < 6 ft. to pool. Maintain 6 ft. clearance around swimming pool in all locations.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter stuck. Keep operational. Intent to Suspend issued.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Sodium bicarb stored on floor in chemical storage room. Maintain dry storage up off floor.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
No soap in men's restroom at one sink. Provide soap at all sinks.
Apr 12, 2019 0 demerits · 0 violations
Inspector comments: No critical violations found.
Facility does not do night swimming.
No violations were recorded for this inspection.
Oct 19, 2018 4 demerits · 1 violation
Inspector comments: Verified PDSC information.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed one door to hallway not self closing self latching.
Corrected during inspection.
.2537(b) All gates and doors shall be self-closing, self-latching.
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “GREENSIDE APARTMENTS” or State ID 2060530481). Inspection type (routine vs. follow-up) is not published in the county's data.