‹ Back to search

28demerits

SHARON CROSSING

2123 EL VERANO CIRCLE, Charlotte, NC 28210
Year-Round Swimming Pool · NC permit/State ID 2060530496
Latest result28 demerits
Last inspectedAug 24, 2026
Inspections on record14
On record sinceMay 28, 2019

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

01836 May 28, 2019: 24Dec 3, 2019: 34Jul 23, 2020: 0Apr 15, 2021: 4Oct 20, 2021: 10Mar 30, 2022: 26Oct 12, 2022: 26Feb 20, 2023: 32Jul 26, 2023: 32Feb 8, 2024: 20Oct 15, 2024: 10Apr 10, 2025: 8Sep 17, 2025: 36Aug 24, 2026: 28
May 28, 2019Lower is betterAug 24, 2026

Inspections & violations

Aug 24, 2026 28 demerits · 6 violations
Inspector comments: Inspection conducted with CPO Kendrick. EHS unable to issue permit today due to the following intent to suspend/immediate suspension items: - Observed one of the two weirs missing. - Observed NO DIVING stencils rubbed off and barely legible. - Observed a few cracks on pool deck measuring greater than 1/2 inch. - Observed damaged/loose coping near ladder. - Observed non-operational flow meter. - Observed damaged return inlet on pool wall. - Observed no spare pump basket. Please call EHS Rusi Woo at 704-430-7960 once all of the above mentioned items have been repaired/corrected. PERMIT RESTRICTION - FLOW METER MUST REMAIN OPERABLE. FLOW SHALL BE AT 76 GPM TO 104 GPM TO MEET TURNOVER AND FLOW RESTRICTION OF EQUALIZER LINE COVERS. SUCTION HAZARD. No night swimming.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
.2537(7) Drain covers shall be in good condition and securely attached. Observed equalizer cover missing from wall. CDI CPO replaced equalizer cover during inspection.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. Observed one of the two weirs missing. Replace. INTENT TO SUSPEND ITEM.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
.2523(d) No Diving markers shall be written in four inch letters or international 6"x6" no diving in red and black on a white background. Observed NO DIVING stencils rubbed off and barely legible. Re-stencil NO DIVING markers on pool deck. INTENT TO SUSPEND ITEM.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed ring buoy rope measuring greater than 30ft. CDI CPO corrected during inspection to measure approximately 30 ft.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. Observed a few cracks on pool deck measuring greater than 1/2 inch. Repair cracks to prevent hazards. INTENT TO SUSPEND ITEM. .2537(3) There shall be no loose coping. Observed damaged/loose coping near ladder. Repair coping to prevent hazards. INTENT TO SUSPEND ITEM.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Observed non-operational flow meter. CDI CPO was able to correct during inspection and flow meter was operational. However, flow not within range of permit restriction. IMMEDIATE SUSPENSION ITEM. .2518(i) Return inlets shall be replaced when damaged or missing. Observed damaged return inlet on pool wall. Repair. INTENT TO SUSPEND ITEM. .2518(e) Provide a spare basket for pump. Observed no spare pump basket. Obtain spare pump basket. INTENT TO SUSPEND ITEM.

View this inspection on the county portal ›

Sep 17, 2025 36 demerits · 8 violations
Inspector comments: Conducted inspection with CPO Julio Guerra. Immediate suspension issued due to pH, detached equalizer cover, ring buoy rope, and inoperable flow meter. Pool must stay closed until items are corrected. Call EHS Devon when ready for re inspection. 7049981122 Correct intent to suspend items as well or intent to suspend may be issued upon re inspection. No night swimming Const. Date: 1/1/1984 Rope Length: 30' PERMIT RESTRICTION - FLOW METER MUST REMAIN OPERABLE. FLOW SHALL BE AT 76 GPM TO 104 GPM TO MEET TURNOVER AND FLOW RESTRITION OF EQUALIZER LINE COVERS.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. PH observed at 6.8. Immediate suspension item.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. No weekly cyanuric acid or alkalinity checks. Intent to suspend item.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
.2537(7) Drain covers shall be in good condition and securely attached. Equalizer cover missing from wall. Immediate suspension item.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
.2523(a) Provide depth markers on pool walls and pool deck next to the swimming pool. Observed depth 6FT depth markers cracked, chipped, and out of compliance. Intent to suspend item.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions. Bottom rung of ladder detached and dangling in water.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Ring buoy rope measured at greater than 30ft. Correct to 30’. Immediate suspension item.
#21 · Premises: pool and deck lighting provided at pools that operate at night −4
.2524(c) Lighting fixtures shall not present a hazard to the public. .2537(9) Underwater light niches shall be maintained or covered so not to present a hazard. Wall light coming out of socket under water. Intent to suspend item.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Observed non-operational flow meter. Immediate suspension item due to suction hazard permit restriction.

View this inspection on the county portal ›

Apr 10, 2025 8 demerits · 2 violations
Inspector comments: Scheduled inspection. Pool inspection conducted with Raekwon. Intent to suspend issued for pool light and pool records. Correct within 30 days or permit may be suspended. Call or text EHS Devon Moeller when corrected 7049981122 Note: Maintain flow between 76gpm and 104gpm to meet turnover and flow restriction of EQ line covers.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. No weekly cyanuric acid or alkalinity checks. No records for April. Organize record binder by date. Intent to suspend item.
#21 · Premises: pool and deck lighting provided at pools that operate at night −4
.2524(c) Lighting fixtures shall not present a hazard to the public. .2537(9) Underwater light niches shall be maintained or covered so not to present a hazard. Wall light coming out of socket under water. Intent to suspend item.

View this inspection on the county portal ›

Oct 15, 2024 10 demerits · 2 violations
Inspector comments: Conducted inspection with current CPO Jonathan. Pool returned to A status and able to reopen. Ensure flow stays between 76 and 100gpm to achieve turnover.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Lifesaving equipment should be conveniently located. Ring buoy rope tangled and inaccessible. Operator corrected. No permit action.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed pool furniture within 6 feet of pool. CPO corrected. No permit action.

View this inspection on the county portal ›

Feb 8, 2024 20 demerits · 5 violations
Inspector comments: Met with operator Jonathan Montalvo. Inspection conducted by Anglecia Askew under supervision of Devon Moeller. IMS issued for new drains. Submit updated PDSE to health department for drain approval. Bathroom flooring scheduled to be replaced by the end of February. 2024 permit shall not be issued until flooring is replaced and approved. Submit slip resistant flooring documentation to the health department for approval prior to the installation. Call EHS Devon Moeller when items have been complete and ready for reinspection. 704998112.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(10) Provide test kit capable of measuring disinfectant level, cyanuric acid and total alkalinity. Some test reagents expired. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Cyanuric acid reading missing from several weeks. Maintain weekly cyanuric acid reading records.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
.2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance. Main drain covers replaced without health department approval or receipt of updated PDSE. Submit new PDSE for approval. Immediate suspension item.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Ring buoy rope measured at 28’. Operator corrected to 30’ and replaced rope.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(j) Provide soap and soap dispenser, no glass, at each sink. No soap in both restrooms.
#32 · Dressing and sanitary facilities: floors smooth, slip-resistant, kept clean −2
.2526(c) Restroom floors shall be smooth to insure cleaning and slip-resistant. Flooring in both restrooms in poor repair - peeling at seams no longer smooth/cleanable and possibly present trip hazard.

View this inspection on the county portal ›

Jul 26, 2023 32 demerits · 9 violations
Inspector comments: Inspection conducted with operator, Jonathan. 30 day intent to suspend the permit issued due to the following items: Damaged and missing tiles on pool wall. Damaged overflow grate fitting on pool wall. Flow meter not operating. Incomplete records Kings III cellular emergency notification system is transmitting incorrect address locator information to local Charlotte 911. Pool has 7 days to have issuer corrected or permit will be suspended. Note: Aquastar main drain covers expire 5/20/2024. Replace the drain covers and submit pdsc for approval prior to drain expiration in order to avoid permit action. Note: Flooring in both restrooms with significant peeling/rolling exposing sub floor and presenting possible trip hazard. Flooring must be repaired or replaced prior to issuance of permit for 2024 operating season. If replacing the floor, slip resistance of the material must be verified before installation. Please visit the website at health.mecknc.gov/envhealth/pools for information on in field plan review or contact Hope McIntosh at 980-229-7549 before installing new flooring.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. No weekly cyanuric acid or alkalinity checks during July. *permit item
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537 - damaged coping around missing overflow grate, missing coping tile in deep end of pool. Repair *permit item
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. Missing weir in one of the two skimmers. Replace.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
.2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. Damaged overflow grate fitting - replace. *permit item
#22 · Premises: emergency telephone provided −6
.2530(f) Emergency notification systems must provide 24 hr. monitoring, be capable of routing calls to 911, and be able to electronically transfer Automatic Number and Locator Identification for the phone. Kings III cellular phone system not transferring correct locator identification to local Charlotte 911. Local 911 operator noted address for this phone number is 8013 Andover Woods Dr which is not in this apartment complex. Correct so that location information provided by Kings III matches location 2123 El Verano Circle, Charlotte, NC. *permit item
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Flow meter not operational. *permit item
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor. Bag of dry chemical stored on floor of chemical storage room. .2534(6) Provide sufficient lighting in chemical storage room. Light out in chemical storage room.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(m) Keep restrooms and fixtures clean and in good repair. Fixtures in both restrooms in need of cleaning.
#32 · Dressing and sanitary facilities: floors smooth, slip-resistant, kept clean −2
.2526(c) Restroom floors shall be smooth to insure cleaning and slip-resistant. Flooring in both restrooms in poor repair - peeling at seams no longer smooth/cleanable and possibly present trip hazard.

View this inspection on the county portal ›

Feb 20, 2023 32 demerits · 8 violations
Inspector comments: Inspection conducted with Jonathan Montalvo. Immediate suspension of permit issued due to emergency phone not receiving call back. Pool closed and signs posted. Pool must remain closed until emergency phone issue is resolved and verified by EHS. Call Hope McIntosh at 980-229-7549 once phone is corrected. Once immediate suspension lifted, a 30 day intent to suspend the permit may be issued for missing record keeping, missing fitting on pool wall, and concrete coping in poor repair. Night swimming is not approved. Main drain covers expire May 2024. Replace and provide documentation prior to expiration.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Observed no records documented since 2/17/23. Items must be checked daily and documented. Permit item
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. Missing weir in one of the two skimmers. Replace.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
.2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. Missing one fitting on pool wall near main entry gate. Replace. Permit item
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide at least 12 ft. long pole with body hook securely attached. Observed hook missing attachment screws not secured to pole. Corrected during inspection .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Ring buoy with rope less than 29’. Corrected to 30’ during inspection.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(3) There shall be no loose coping. Observed damage to concrete coping at various places around pool perimeter especially near ladder. Repair. Permit item
#22 · Premises: emergency telephone provided −6
.2530(f) Emergency phone shall remain operable. Kings III box not capable of receiving call back at this time. Phone number posted rings but never connects. Operator noted some work on computer systems may have changed line. Immediate suspension issued.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(j) Provide soap and soap dispenser, no glass, at each sink. No soap in womens restroom
#32 · Dressing and sanitary facilities: floors smooth, slip-resistant, kept clean −2
.2526(c) Restroom floors shall be smooth to insure cleaning and slip-resistant. Flooring in mens restroom in poor repair - peeling at seams no longer smooth and cleanable.

View this inspection on the county portal ›

Oct 12, 2022 26 demerits · 6 violations
Inspector comments: Inspection completed with Jonathan Montalvo. Observed pump set at 3110 RPM as required in permit restrictions. Intent to suspend permit issued for missing records for month of October, 2022. Correct within 30 days or permit may be suspended. Contact Eli Freese at 704.621.2298 with any questions.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Observed no records for month of October. Ensure records are filled out daily. Intent to suspend issued. Correct or permit may be suspended.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed one missing overflow grate. Replace.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Pole for body hook must be non-telescoping, non-adjustable, and non-collapsible. Observed body hook on telescoping pole. CDI- body hook changed to non-telescoping pole.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing, self-latching. Observed door from gym to pool deck not self-latching. CDI- repaired.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed pool furniture within 6 feet of pool. CDI- relocated.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Observed non-operational flow meter.

View this inspection on the county portal ›

Mar 30, 2022 26 demerits · 6 violations
Inspector comments: Inspection completed with Lilly Dominguez present. Immediate suspension issued for body hook on telescoping pole and chlorine at 0.4 ppm. Contact Eli Freese at 704.621.2298 once corrected to reopen pool. Replace missing signs or an intent to suspend will be issued once the permit is reinstated.
#2 · Water quality: disinfectant residual provided by −6
.2535(4) Maintain chlorine at least 1.0 ppm. Observed chlorine at 0.4 ppm. Immediate suspension issued.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Pole for body hook must be non-telescoping, non-adjustable, and non-collapsible. Observed body hook connected to telescoping pole. Immediate suspension issued.
#18 · Premises: lifeguards present or warning signs posted −4
.2530(c) Provide "Warning - No Lifeguard on Duty" in 4" lettering. .2530(c) Provide "Children should not use the swimming pool without adult supervision." in 1" lettering. Observed signs not posted.
#19 · Premises: signs prohibit glass containers or pets in pool area −4
.2530(d) Provide a sign prohibiting pets and glass containers in the pool area. Observed no signs posted.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Observed flow meter non operational.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(m) Keep restrooms and fixtures clean and in good repair. .2526(l) Provide toilet paper and dispensers in restrooms. .2526(j) Provide soap and soap dispenser, no glass, at each sink. Observed no soap, toilet paper, or paper towels in mens and womens restrooms. Womens restroom also had 1 missing toilet.

View this inspection on the county portal ›

Oct 20, 2021 10 demerits · 3 violations
Inspector comments: Inspection completed with Rashad Henry present. No signature due to COVID. Intent to suspend permit issued for faded "WARNING NO LIFEGUARD ON DUTY" sign. Replace within 30 days or permit will be suspended. Observed throw rope connected to ring buoy beginning to fray but still in good repair. Recommend replacing before rope is damaged.
#18 · Premises: lifeguards present or warning signs posted −4
.2530(c) Provide "Warning - No Lifeguard on Duty" in 4" lettering. Observed sign faded and difficult to read. Intent to suspend issued. Replace within 30 days.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Observed non-operational flow meter.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(l) Provide toilet paper and dispensers in restrooms. Observed no toilet paper in both restrooms. .2526(j) Provide soap and soap dispenser, no glass, at each sink. Observed no soap in both restrooms.

View this inspection on the county portal ›

Apr 15, 2021 4 demerits · 1 violation
Inspector comments: Inspection completed with Glen McRae and Tony Riviera present. No signature due to COVID-19.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed pool furniture within 6 feet of pool. CDI- furniture rearranged.

View this inspection on the county portal ›

Jul 23, 2020 0 demerits · 0 violations
Inspector comments: Inspection completed with Toemars Levell on-site. No signature due to COVID-19. PDSC information verified in-field.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Dec 3, 2019 34 demerits · 9 violations
Inspector comments: Observed chlorine pucks on the pool bottom. Pucks cannot be in the pool when it is open. Observed pool pump switched out. Mecklenburg County Health Department has no record of this change. This must be resolved with the Health Department. The pool cannot reopen for swimming without Health Department follow-up inspection and approval. Permit Suspended. Electrical inspection may also be required.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
Observed Intelliflo VSF pump with 3HP motor installed. Mecklenburg County Health Department does not have record of this pump being installed on this system. Permit is suspended. Pool must remain closed to swimming until Health Department approved reopening.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed skimmer basket damaged to the point that debris is passing into the pump. Replace the skimmer basket.
#10 · Pool maintenance: safety ropes with floats and contrasting color bands provided at shallow area breakpoints −2
Observed breakpoint rope not in place.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
Observed 1 missing eyeball fitting from the returns. Observed vacuum port to be open and not have the cap on. Provide vacuum port cover.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed ring buoy throw rope to be 33ft. long. Corrected to 30ft. as required. -CDI
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed furniture to be too close to the water edge. Items must be back at least 6 feet. -CDI Items were moved.
#18 · Premises: lifeguards present or warning signs posted −4
Observed warning signs not properly posted. Proper warning signs with correct language and letter heights must be posted.
#27 · Equipment room: filter backwash discharged through an air gap −2
Observed no air gap at the backwash line.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
Observed no shower sign posted.

View this inspection on the county portal ›

May 28, 2019 24 demerits · 5 violations
Inspector comments: Permit suspended based on unapproved PDSC form (Item 6), as well as expired test kit chemicals (Item 5) and inoperable flow meter (Item 24). Ensure that all are corrected before next visit to ensure facility can return to A status. Night swimming is not approved at this facility.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(10) Provide test kit capable of measuring disinfectant level, cyanuric acid and total alkalinity. Observed test kit with expired chorine reagent and pH reagent expiring 06/19. PIC stated that new kit had been ordered.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
.2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance. Observed PDSC form with expired main drain and equalizer covers. CPO must submit updated form to Department before facility may oprate.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed ring buoy rope at 28 ft, where 30 ft is required. CDI: PIC un-knotted the rope and afterwords, rope measured 30 ft.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Access gates shall swing away from the pool and be self-latching, self-closing unless an attendant AND lifeguard are present. Observed pool gate not self-latching during inspection. CDI: CPO applied WD-40 to springs on gate, and after a few minutes, gate was self closing and self latching.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Observed flow meter inoperable during visit.

View this inspection on the county portal ›

Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “SHARON CROSSING” or State ID 2060530496). Inspection type (routine vs. follow-up) is not published in the county's data.