BRIDGES AT MALLARD CREEK

7916 HARRIS HILL LN, Charlotte, NC 28269
Year-Round Swimming Pool · NC permit/State ID 2060530507
Latest result20 demerits
Last inspectedFeb 19, 2026
Inspections on record11
On record sinceMay 22, 2019

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

02142 May 22, 2019: 10Aug 29, 2019: 42Jul 1, 2020: 16Apr 20, 2021: 26Jun 15, 2022: 16Apr 25, 2023: 24May 30, 2024: 18Aug 21, 2024: 24May 15, 2025: 32Sep 3, 2025: 18Feb 19, 2026: 20
May 22, 2019Lower is betterFeb 19, 2026

Inspections & violations

Feb 19, 2026 20 demerits · 5 violations
Inspector comments: Issued immediate suspension for pH and return flow. Pool is to remain closed until items are corrected. Please call James Bjorneboe at 704-507-6820 when items are fixed to schedule re-visit.
#3 · Water quality: pool water pH −6
Observed pH at 6.9. Maintain between 7.2-7.8. .2535(1) Maintain pH at 7.2 to 7.8.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Observed no records being kept since December. Maintain records as required. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed end caps missing on all ladders. Replace. .2521 Install ladders per manufacturer instructions.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed deck chairs within 6 feet of pools edge. Maintain 6 feet of clearance at all points. .2522(a) Provide 6 ft of clear walking space around the pool at all times.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed return flow at 70 gpm. Return flow must remain between 59- 63 gpm.

View this inspection on the county portal ›

Sep 3, 2025 18 demerits · 6 violations
Inspector comments: Inspection conducted with CPO Randy Frack. Outer rope on ring buoy and throw rope fraying. Recommend replacing with new US Coast Guard approved ring buoy with attached 30 foot throw rope at least 1/4 inches in diameter. Decking around ladder chipped, some caulking missing from expansion gaps and some gaps between deck drains. Maintain deck with no gaps or offsets > 1/2 inches. Static on emergency phone line. Recommend having phone company/Kings III check emergency phone. Permit condition that flow meter read between 59 and 63 GPM. Verified at 63 GPM.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Skimmer baskets full of leaves. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Corrected.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Ladders extend > 6" into the pool. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall. Ladder missing endcaps. .2521 Install ladders per manufacturer instructions.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Some chairs too close to pool edge. .2522(a) Provide 6 ft of clear walking space around the pool at all times. - Corrected. Hole in the deck where one of the volleyball net poles go. .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. - Corrected.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter stuck. .2518(g) Keep flow meter operational. - Corrected.
#27 · Equipment room: filter backwash discharged through an air gap −2
No air gap for backwash line. .2513(b) Filter backwash shall be discharged through an air gap.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
One faucet in men’s and one faucet in women’s restroom not functioning. .2526(m) Keep restrooms and fixtures clean and in good repair.

View this inspection on the county portal ›

May 15, 2025 32 demerits · 10 violations
Inspector comments: Inspection conducted with CPO Randy Frack. Pool re-plastered. Equalizer lines planted over on pool walls. Now have tiled contrasting color bands. Verified PDSC information for new drain covers. Outer rope on ring buoy fraying. Recommend replacing with new US Coast Guard approved ring buoy. Decking around ladder chipped, some caulking missing from expansion gaps and some gaps between deck drains. Maintain deck with no gaps or offsets > 1/2”. Mirrors were changed last year, do not have documentation that mirrors are shatterproof or have safety backing. Will need to provide documentation before 2026 pool permit will be issued. Intent to suspend issued 8) 17) 24) Have until 5/31/2025 to make corrections before current permit expires. Contact Will Harrison (704) 507-6824 for re-inspection once issues have been corrected.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
One weir not fully installed. .2518(k) Provide functional weirs. - Corrected. Observed skimmer equalizer valves installed. Will need to remove and abandon equalizer lines per state guidelines. .2518(l) Skimmer equalizer lines shall be in compliance with ANSI/PHTA/ICC-7 or disabled by plugging the line under the skimmer basket and on the pool wall. - Intent to suspend item.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Ladders extend > 6" into the pool. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Gate to patio not self-latching. .2528(a) Access gates shall swing away from the pool and be self-latching, self-closing. - Corrected. Pre-2010 fencing with gap > 4” through fence. .2528(a) Provide no openings in fence and/or gate greater than 4"x4".
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Chairs and umbrella too close to pool edge. .2522(a) Provide 6 ft of clear walking space around the pool at all times. - Intent to suspend item.
#22 · Premises: emergency telephone provided −6
I corrected phone number posted for emergency phone. .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. - Corrected.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Pool recently replastered. Vacuum cap not installed. Vacuum off in the pump room. .2518(f) Provide a vacuum cap or self-closing cap for pools built after May 1, 2010. - Intent to suspend item.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Bag of dry chemicals stored on pump room floor. .2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor.
#27 · Equipment room: filter backwash discharged through an air gap −2
No air gap for backwash line. .2513(b) Filter backwash shall be discharged through an air gap.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
One faucet in men’s restroom not functioning. .2526(m) Keep restrooms and fixtures clean and in good repair. New mirrors. Not able to determine if shatterproof or have safety backing. .2526(k) Provide shatterproof mirrors.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
Fill spout directly on pool deck and extends > 2 inches into the pool. .2512(c) Over the rim fill spouts shall not protrude greater than two inches beyond the edge of the pool and shall be at least two pipe diameters above the pool.

View this inspection on the county portal ›

Aug 21, 2024 24 demerits · 8 violations
Inspector comments: Inspection conducted with CPO Randy Frack. Contrasting color bands fading. Prior to 2025 permit being issued. Will need to repaint at least 2” wide contrasting color band at leading edge of pool steps. Takes a while for Kings III to connect when calling back to the box. Recommend to have Kings III adjust to connect in 3 rings or less. Intent to suspend issued 5)
#5 · Water quality: daily written records of water quality and test kit kept on site −4
No place on log sheet for main drain checks. No records for the weekends. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. - Intent to suspend item.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Ladders extend > 6" into the pool. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall. Ladder missing endcaps. .2521 Install ladders per manufacturer instructions.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Throw rope not attached to ring buoy. .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. - Corrected.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Hole in the deck where one of the volleyball net poles go. .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. - Corrected.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Fan not working in pump room. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room. Bag of dry chemicals stored on pump room floor. .2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor.
#27 · Equipment room: filter backwash discharged through an air gap −2
No air gap for backwash line. .2513(b) Filter backwash shall be discharged through an air gap.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
One faucet in men’s restroom not functioning. .2526(m) Keep restrooms and fixtures clean and in good repair. New mirrors. Not able to determine if shatterproof or have safety backing. .2526(k) Provide shatterproof mirrors.
#33 · Dressing and sanitary facilities: hose bibbs and floor drains provided −2
Hose Bibb for restrooms not observed. .2526(d) Provide hose bib so that all parts of restroom can be reached with a 50 ft hose.

View this inspection on the county portal ›

May 30, 2024 18 demerits · 7 violations
Inspector comments: Inspection conducted with CPO Randy. New Pentair SuperflowVST pump installed. Electrical permit E4595394 passed inspection 3/25/2024. New permit condition. Flow meter must remain operable and read between 59 GPM and 63 GPM to meet minimum turnover and flow restriction of the filter. Deck chipping around handrail. Maintain in good condition. Main drains expire 9-26-2025. Replace with ANSI/APSP/ICC-16 approved drain covers and provide updated Pool Drain Suction Compliance form to MeckPools@MeckNC.gov for approval. Contrasting color bands fading. Prior to 2025 permit being issued. Will need to repaint at least 2” wide contrasting color band at leading edge of pool steps. Takes a while for Kings III to connect when calling back to the box. Recommend to have Kings III adjust to connect in 3 rings or less. Permit issued. Paper permit will be issued online in 3-5 days for your records.
#3 · Water quality: pool water pH −6
PH 7.1. .2535(1) Maintain pH at 7.2 to 7.8. - Corrected to 7.2.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Ladders extend > 6" into the pool. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall. Ladders missing endcaps. .2521 Install ladders per manufacturer instructions. - Corrected.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Fan not working in pump room. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room.
#26 · Equipment room: valves and pipes identified by color codes or labels −2
Some piping labels faded. New piping for new pump not labeled. .2518(d) Piping and valves shall be labeled with color codes or labels.
#27 · Equipment room: filter backwash discharged through an air gap −2
No air gap for backwash line. .2513(b) Filter backwash shall be discharged through an air gap.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
One faucet in men’s restroom and one faucet in women’s restroom not functioning. .2526(m) Keep restrooms and fixtures clean and in good repair. New mirrors. Not able to determine if shatterproof or have safety backing. .2526(k) Provide shatterproof mirrors.
#33 · Dressing and sanitary facilities: hose bibbs and floor drains provided −2
Hose Bibb for restrooms not observed. .2526(d) Provide hose bib so that all parts of restroom can be reached with a 50 ft hose.

View this inspection on the county portal ›

Apr 25, 2023 24 demerits · 8 violations
Inspector comments: Inspection conducted with CPO Tim Rankin. Note* Flow meter reads 75 GPM, but is installed directly between 2 elbows. System has a TR60 sand filter which isn’t capable of handling 75 GPM. Recommend installing a flow meter per manufacture’s instructions capable of reading within 10% of true flow. Light switch in pump room covered up, switch plate broken. Maintain in good condition and easily accessible. Facility changed to Kings III call box, takes 7 or 8 rings before prompted to be connected to the box. Recommend having Kings III reduce to fewer rings or taken immediately to the prompt when calling the box. Equalizer line covers expire 9/26/2023. Replace with new APSP-17 approved covers or abandon prior to cover expiration and provide updated PDSC form to our department for approval. Intent to suspend issued 7) 16) 17) Permit expires 4/30/2023. Will be back on 5/1/2023 to verify that intent to suspend items have been corrected and issue the new permit if corrections have been made.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
No recent total alkalinity or cyanuric acid checks. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. - Corrected.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Pool floor dirty. Main drains turned off in the pump room. .2537(14) Keep pool surface and pool floor free of debris. - Intent to suspend item.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Ladders extend > 6" into the pool. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall. Ladders missing endcaps. .2521 Install ladders per manufacturer instructions.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Gate to patio with missing magnalatch. .2528(a) Access gates shall swing away from the pool and be self-latching, self-closing. .2528(a) Gate latches shall be 54" in height. - Intent to suspend item.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Hole in the deck where the fill spout normally is (this was corrected), hole in the deck where one of the volleyball net poles go. .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. - Intent to suspend item.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Fan not working in pump room. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room. Dry chemicals on pump room floor. .2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor.
#27 · Equipment room: filter backwash discharged through an air gap −2
No air gap for backwash line. .2513(b) Filter backwash shall be discharged through an air gap.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Out of toilet paper in one of the stalls in the men’s restroom. .2526(l) Provide toilet paper on dispensers in restrooms.

View this inspection on the county portal ›

Jun 15, 2022 16 demerits · 6 violations
Inspector comments: Inspection conducted with new CPO, Ryan Mobley. Updated CDP with new CPO information. New 1.65 THP motor installed on existing Sta-Rite pump. Pump not labeled. Electrical permit E4174324 passed inspection 5-18-2022. Issues from previous inspection corrected. Safety signage back ordered, temporary printed signs in place in covered seating area. Will verify that permanent signage is in place on next inspection. Permit issued No Night Swimming. Paper permit will be available on our website, Meckpools.Charmeck.org in 3-5 business days for your records.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
No place on pool log sheet for main drain checks or pool maintenance activities. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections,and pool water maintenance. Provide weekly recordings for cyanuric acid and total alkalinity. - Corrected. Operator will use state log sheet.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Ladders extend > 6" into the pool. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall.
#18 · Premises: lifeguards present or warning signs posted −4
Safety signage in less than 1 inch lettering. .2530(c) Provide "Children should not use the swimming pool without adult supervision." in 1" lettering. - Corrected. New temporary signage in place. Permanent sign ordered. Safety signage in less than 1 inch lettering. .2530(c) Provide "Adults should not swim alone." in 1" lettering. - Corrected. New temporary signage in place. Permanent sign ordered.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Fan not working in pump room. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room.
#27 · Equipment room: filter backwash discharged through an air gap −2
No air gap for backwash line. .2513(b) Filter backwash shall be discharged through an air gap.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
One faucet in men’s restroom not functioning. .2526(m) Keep restrooms and fixtures clean and in good repair.

View this inspection on the county portal ›

Apr 20, 2021 26 demerits · 8 violations
Inspector comments: Inspection conducted with CPO Tim Rankin. Due to COVID-19 precautions, inspection was not signed by the operator. Lamar is no longer the CPO. Tim Rankin is new CPO. Updated the file with new CPO information. Filter pressure 32 psi, flow meter stuck, pump cavitating. Maintain equipment in good working order. Operator backwashed, psi dropped to 10, pump and flow meter then operated normally. “Executive Order No. 141 or subsequent Orders are in effect unless such Orders are rescinded or superseded by another applicable Order.” Intent to suspend issued 5) 16) 17) Facility has until May 1st when current permit expires to correct the intent to suspend items or permit will be suspended. Contact Will Harrison (704-507-6824) for reinspection when issues have been corrected.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Reagents in test kit expired. .2535(10) Provide test kit capable of measuring disinfectant level, cyanuric acid and total alkalinity. - Intent to suspend item. No main drain checks. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, and pool water maintenance. Provide weekly recordings for cyanuric acid and total alkalinity weekly. - Intent to suspend item.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
No flow in the skimmers. .2518(k) Ensure skimmers are capable of operating per manufacturer instruction. - Corrected when operator backwashed the filter.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Ladders extend > 6" into the pool. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Service gate missing gate latch. .2528(a) Gates other than pedestrian access gates shall have a self-latching device at least 54" high or shall be at least 3" below the top of the gate on the pool side of the gate with no openings > 1/2" within 18" of the release mechanism. - Intent to suspend item.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Hole in the deck where the fill spout normally is. .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. - Intent to suspend item.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter stuck. .2518(g) Keep flow meter operational. - Corrected
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Leak at the pump. Clean up build up of minerals and salts on pump and wiring. .2533(d) Pump room floor shall be kept dry and free of standing water. Pump room partially used for storage. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
#27 · Equipment room: filter backwash discharged through an air gap −2
No air gap for backwash line. .2513(b) Filter backwash shall be discharged through an air gap.

View this inspection on the county portal ›

Jul 1, 2020 16 demerits · 6 violations
Inspector comments: Inspection conducted with Lamar Richardson. Due to COVID-19 precautions, inspection was not signed by the operator. Issues from previous inspection corrected, including contrasting colorband repainted. Out of paper towels in women's restroom. Recommend restocking. Permit issued. No Night Swimming “Executive Order No. 141 or subsequent Orders are in effect unless such Orders are rescinded or superseded by another applicable Order.”
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Ladders extend > 6" into the pool. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall.
#22 · Premises: emergency telephone provided −6
Part of address faded on emergency phone sign. .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Corrected.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Light not working in the pump room. .2533(b) Provide sufficient lighting in pump room.
#26 · Equipment room: valves and pipes identified by color codes or labels −2
Vacuum line not labeled. .2518(d) Piping and valves shall be labeled with color codes or labels.
#27 · Equipment room: filter backwash discharged through an air gap −2
No air gap for backwash. .2513(b) Filter backwash shall be discharged through an air gap.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
One of the faucets in the men's restroom not working. .2526(m) Keep restrooms and fixtures clean and in good repair.

View this inspection on the county portal ›

Aug 29, 2019 42 demerits · 11 violations
Inspector comments: Immediate suspension issued 3) 15) 22) Contact Will Harrison (704-507-6824) for reinspection when issues have been corrected.
#3 · Water quality: pool water pH −6
pH 7.0. .2535(1) Maintain pH at 7.2 to 7.8. - Immediate suspension item.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Did not observe any records since August 6th. No maintenance activities or main drain checks this summer. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, and pool water maintenance. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Maintain Cyanuric Acid at no more than 100ppm. - Intent to suspend item.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Pool floor dirty. .2537(14) Keep pool surface and pool floor free of debris. - Intent to suspend item.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Ladders missing endcaps. Maintain in good condition. Ladders extend > 6" into the pool. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall.
#13 · Pool maintenance: contrasting band on steps and benches −4
Contrasting color bands on steps stop 4-6" from the wall. .2521(b) Provide at least 2" contrasting color band to edge of stair treads. - Intent to suspend item.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Ring buoy damaged. Throw rope heavily frayed. .2530(a) Provide USCG approved ring buoy with 30 foot throw rope. Rope shall be at least 1/4" in diameter. - Immediate suspension item. Body hook pole 11 feet long. .2530(a) Provide at least 12 foot body hook pole. Pole for body hook must be non-telescoping, non-adjustable, and non-collapsible. - Immediate suspension item.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Holes in the pool deck. .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. - Intent to suspend item. Deck chairs too close to pool edge. .2522(a) Provide 6 ft of clear walking space around the pool at all times. - Intent to suspend item.
#22 · Premises: emergency telephone provided −6
More than one set of signage for emergency phone. One with incorrect address and one with incorrect phone number. .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. - Immediate suspension item.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Lights burned out in the pump room. .2533(b) Provide sufficient lighting in pump room. Dry chemicals stored on drum of liquid chlorine. .2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up.
#26 · Equipment room: valves and pipes identified by color codes or labels −2
.2518(d) Piping and valves shall be labeled with color codes or labels.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Faucets in men's restroom not functioning. .2626(m) Keep restrooms and fixtures clean and in good repair.

View this inspection on the county portal ›

May 22, 2019 10 demerits · 3 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed pool floor in need of cleaning.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed pool chair stored to close to pool edge (4.5 ft).
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
.2512(b) Water introduced into the pool, either directly or by the circulation system, shall be supplied through an air gap, anti-siphon vacuum breaker, or backflow preventer. Observed hose bibs not having back flow preventer installed.

View this inspection on the county portal ›