24demerits
8 METRO STATION
4027 LIBBY WAY, Charlotte, NC 28262
Year-Round Swimming Pool · NC permit/State ID 2060530523
Latest result24 demerits
Last inspectedOct 26, 2026
Inspections on record15
On record sinceMay 24, 2019
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
May 24, 2019Lower is betterOct 26, 2026
Inspections & violations
Oct 26, 2026 24 demerits · 5 violations
Inspector comments: Issued intent to suspend for inadequate record keeping. Maintain daily and weekly records as required. Return visit will be made in 30 days to determine compliance. Please call James Bjorneboe at 704-507-6820 with any questions.
#3 · Water quality: pool water pH −6
Observed pH at 6.9. Adjusted to 7.2 onsite.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Observed no daily written records on file since September 1, 2026. Maintain daily written records as required.
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed excessive debris in skimmers. Keep skimmers free of debris.
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Ring bouy rope excessively tangled. Corrected on site. Keep throw rope in working condition at all times.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed gate at pump room not self latching. Corrected onsite.
May 12, 2026 6 demerits · 1 violation
Inspector comments: All violations from previous immediate suspension have been corrected. Permit reinstated.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed throw rope at 31 feet. Throw rope must be 48 feet in length. Corrected during inspection.
Sep 3, 2025 32 demerits · 8 violations
Inspector comments: Issued immediate suspension for Chlorine and missing ring bouy and throw rope. Pool must remain closed until items are corrected. Please call James Bjorneboe at 704-576-2335 once all items are corrected.
#2 · Water quality: disinfectant residual provided by −6
Observed no chlorine in pool. Maintain pool at a minimum of 1.0ppm
.2535(4) Maintain chlorine at least 1.0 ppm.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Observed no records onsite. Keep and maintain as required.
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed excessive debris in skimmers. Keep skimmers free of debris.
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed 1 loose ladder. Tighten ladder.
.2521 Install ladders per manufacturer instructions.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed ring bouy and throw rope missing. Replace.
.2530(a) Lifesaving equipment includes body hook and pole and USCG approved ring buoy with required rope length.
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed gate closest to the leasing office ice not self closing. Repair.
.2537(b) All gates and doors shall be self-closing, self-latching.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed some deck drains protruding well over 1/2” from pool deck. Repair.
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed leak in pump room causing water to stand in both pump and chemical room. Observed bags of product in chemical room on on wet floor. Correct these issues.
.2533(d) Pump room floor shall be kept dry and free of standing water.
.2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor.
Apr 9, 2025 6 demerits · 2 violations
Inspector comments: All items from immediate suspension on previous visit have been corrected. Permit reinstated.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed excessive debris in skimmers. Keep Skimmers free of debris.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed bags of sodium bicarbonate on chemical room floor. Store bags off of the floor in the chemical room.
Oct 3, 2024 30 demerits · 6 violations
Inspector comments: Issued immediate suspension for chlorine levels, tangled throw rope, emergency phone number not posted and inoperable pump. Pool must remain closed until all items have been corrected. Please call James Bjorneboe at 704-507-6820 once items have been corrected to schedule re-visit.
#2 · Water quality: disinfectant residual provided by −6
Observed chlorine at 0.5ppm. Chlorine must be at a minimum of 1.0ppm.
.2535(4) Maintain chlorine at least 1.0 ppm.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed throw rope extremely tangled. Ensure throw rope is kept in tangles and in good working condition at all times. Throw rope must be 48’ in length.
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less.
.2530(a) Lifesaving equipment includes body hook and pole and USCG approved ring buoy with required rope length.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed mesh around gate near pump room separating from fence. Repair.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed numerous deck chairs/furniture with in 6 feet of pools edge. Maintain 6 feet of clearance at all points.
.2522(a) Provide 6 ft of clear walking space around the pool at all times.
#22 · Premises: emergency telephone provided −6
Observed no phone number posted at emergency phone. Post number at phone.
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed pump motor detached from pump at time of visit. Repair pump as needed.
.2518(h) Provide approved pump in good repair.
Jan 5, 2024 12 demerits · 3 violations
Inspector comments: Immediate suspension lifted. Permit sticker issued. Advised that drain covers expire on 4/1/2024 and require replacement before 2024 operating permit will be issued. A new and complete PDSC form must be submitted to this department and approved before permit issued. Pool information and PDSC form can be found at www.mecknc.gov. Please contact James Bjorneboe at 704-507-6820 with any questions
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Excessive debris present in skimmers. Removed debris on site.
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed throw rope extremely tangled. Corrected on site.
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed bags of sodium bicarbonate on the floor of chemical room. Corrected onsite.
Mar 6, 2023 8 demerits · 2 violations
Inspector comments: General comment: 911 operator had address for pool as 5025 Wembley Central Dr at corner of Libby Wy., which is the leasing office address. Address for pool is 4027 Libby Wy. Contact phone company to have address for pool changed in 911 system to 4027 Libby Wy. Please call James Bjorneboe with any questions at 704-507-6820.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed excessive debris in skimmers. Keep skimmers free of debris.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed deck furniture within 6 feet of pools edge. Maintain 6 feet of clearance at all points. Corrected on site.
Nov 17, 2022 6 demerits · 1 violation
Inspector comments: 911 operator had address for pool as 5025 Wembley Court Way. Address for pool is 4027 Libby Wy. Have phone company change address so that when 911 is called 4027 Libby Wy shows up as the pool address. Return visit will be made in 10 business days. Call James Bjorneboe at 704-507-6820 with any questions.
#3 · Water quality: pool water pH −6
Observed pH at 7.0. Adjusted to 7.2 onsite.
Mar 8, 2022 6 demerits · 2 violations
Inspector comments: Inspection conducted with Germain Murray. Due to COVID-19 precautions, inspection not signed by the operator.
Outer rope on ring buoy starting to fray. Recommend replacing with new, USCG approved ring buoy. Throw rope length for this pool is 48 feet.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Some deck chairs too close to pool edge. .2522(a) Provide 6 ft of clear walking space around the pool at all times. - Corrected.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Dry chemicals on the ground in the chemical storage room. .2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor.
Muriatic acid stored in pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
Aug 30, 2021 10 demerits · 2 violations
Inspector comments: Inspection conducted with Gerald Hinson. Due to COVID-19 precautions, inspection was not signed by the operator.
Outer rope on ring buoy starting to fray. Recommend replacing with new USCG approved ring buoy. Ensure throw rope is 48 feet long.
Observed some sand washed away from between pavers and coping. Recommend grouting, caulking, or filling this back in with polymetric sand prior to this Winter.
Observed eyeball for bubblers have now been installed.
Facility is changing ownership. Please fill out updated pool application and return it to our office so that we can update our records. Application emailed to management.
#3 · Water quality: pool water pH −6
pH 7.1. .2535(1) Maintain pH at 7.2 to 7.8. - Corrected to 7.2.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
No recent total alkalinity checks. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. - Corrected. TA tested at 50ppm.
Apr 19, 2021 16 demerits · 5 violations
Inspector comments: Inspection conducted with Lewis Bower. Due to COVID-19 precautions, inspection was not signed by the operator.
Outer rope on ring buoy starting to fray. Recommend replacing with new USCG approved ring buoy. Ensure throw rope is 48 feet long.
Intent to suspend issued
12)
16)
Contact Will Harrison (704-507-6824) when issues corrected for reinspection.
“Executive Order No. 141 or subsequent Orders are in effect unless such Orders are rescinded or superseded by another applicable Order.”
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
3 of 6 bubblers with broken eyeball fittings. .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. - Intent to suspend item.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Main gate recently damaged. No longer self-closing and self-latching. .2537(b) All gates and doors shall be self-closing, self-latching. - Intent to suspend item.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Both vacuum caps not latched. .2518(f) Provide a vacuum cap or self-closing cap for pools built after May 1, 2010. - Corrected.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Fan not working in the pump room. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Faucet damaged in men's restroom.
.2526(m) Keep restrooms and fixtures clean and in good repair.
Jul 23, 2020 4 demerits · 1 violation
Inspector comments: Inspection conducted with Lewis Bower. Due to COVID-19 precautions, inspection was not signed by the operator.
“Executive Order No. 141 or subsequent Orders are in effect unless such Orders are rescinded or superseded by another applicable
Order.”
Intent to suspend issued
5)
#5 · Water quality: daily written records of water quality and test kit kept on site −4
CPO on file no longer works here. Provide updated CPO information to our Department. .2537(c) Pool owner shall provide for the operation and maintenance of the pool by a trained pool operator. - Intent to suspend item.
Feb 19, 2020 10 demerits · 3 violations
Inspector comments: Pool no longer using backup erosion chlorinator. Using a liquid chlorine/acid feeding system. Tested that system shuts off when the pump is off.
Far skimmer basket floating. Recommend using an NSF approved weighted skimmer basket to keep debris from getting past the basket. Can also use adjustable float valves to limit flow on skimmers closer to the pump room for better pull at far skimmer.
Intent to suspend issued.
5)
16)
#5 · Water quality: daily written records of water quality and test kit kept on site −4
No main drain checks. Pool not checked every day, few maintenance activities recorded. If pool is closed ensure that is reflected in the pool log book and closed signs are posted. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, and pool water maintenance. Provide weekly recordings for cyanuric acid and total alkalinity weekly. - Intent to suspend item.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Gate by restrooms not self-latching. .2528(a) Access gates shall swing away from the pool and be self-latching, self-closing unless an attendant AND lifeguard are present. - Intent to suspend item.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Dry chemicals on the ground in the chemical storage room. .2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor.
Aug 14, 2019 14 demerits · 4 violations
Inspector comments: Left copy of state pool log sheet in the chemical storage room for operator to use.
Unable to check doors from meeting room that open onto the pool deck. Ensure that doors are self-closing and self-latching or are alarmed.
Intent to suspend issued.
5)
8)
17)
#5 · Water quality: daily written records of water quality and test kit kept on site −4
No recent main drain checks. CYA consistently 90-100ppm. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, and pool water maintenance. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Maintain CYA at no more than 100ppm. - Intent to suspend item.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
All the skimmers with debris. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Intent to suspend item.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Many of the deck chairs too close to the pool edge. .2522(a) Provide 6 ft of clear walking space around the pool at all times. - Intent to suspend item.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Bags of soda ash stored on the floor in the chemical storage room. .2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor.
May 24, 2019 0 demerits · 0 violations
Inspector comments: Observed no non-compliant conditions.
Verified PDSC information.
Pool Width – 32’
Rope Length – 48’
Max Depth – 4’
Pump – Pentair XFE-8
Filter – Pentair TR140C
Main Drains – Aquastar 914xxx
Permit restrictions
Salt not approved as primary chlorination
Pool is not approved night swimming
No violations were recorded for this inspection.
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “8 METRO STATION” or State ID 2060530523). Inspection type (routine vs. follow-up) is not published in the county's data.