‹ Back to search

10demerits

COURTYARD BY MARRIOTT CHARLOTTE

8536 OUTLETS BLVD, Charlotte, NC 28278
Year-Round Swimming Pool · NC permit/State ID 2060530550
Latest result10 demerits
Last inspectedJul 22, 2026
Inspections on record14
On record sinceJun 30, 2020

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

0510 Jun 30, 2020: 0Oct 1, 2020: 6Feb 25, 2021: 6Aug 19, 2021: 4Apr 1, 2022: 0Aug 31, 2022: 4Feb 22, 2023: 4Aug 9, 2023: 6Feb 22, 2024: 2Sep 11, 2024: 6Mar 19, 2025: 6Sep 4, 2025: 2Jan 21, 2026: 0Jul 22, 2026: 10
Jun 30, 2020Lower is betterJul 22, 2026

Inspections & violations

Jul 22, 2026 10 demerits · 2 violations
Inspector comments: Inspection was conducted with PICs Andy, Sylvia, and Rachel. APPROVED FOR NIGHT SWIMMING WITH VERIFICATION 6/30/2020. RE-VERIFIED BY EHS DEVON MOELLER ON JAN 2026. MUST BE RE-VERIFIED IN 2029.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed skimmers with debris. CPO dumped out skimmers during inspection.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed rope length measuring at 25 ft. CPO went to Lowe's during inspection to replace with brand new rope, measuring approximately at 27 ft.

View this inspection on the county portal ›

Jan 21, 2026 0 demerits · 0 violations
Inspector comments: Property has new CPO Matt Moyer. All items in compliance. Pool remains in good standing and on A status. Pool is heated. Const. Date: 5/1/2020 Rope Length: 27' Night swimming re verified during inspection by EHS - must be re verified 2029

No violations were recorded for this inspection.

View this inspection on the county portal ›

Sep 4, 2025 2 demerits · 1 violation
Inspector comments: Conducted pool inspection. Pool remains in good standing and on A status. Pool is heated. Const. Date: 5/1/2020 Rope Length: 27' APPROVED FOR NIGHT SWIMMING WITH VERIFICATION 6/30/2020 MUST BE REVERIFIED 2026
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions. Main pool stair railing loose. Tighten per manufacturers instructions.

View this inspection on the county portal ›

Mar 19, 2025 6 demerits · 2 violations
Inspector comments: Conducted inspection with CPO Patrick. Pool remains in good standing and on A status. Drain covers expire 4/10/2025. Pool has drain covers scheduled for replacement the last week of March. Ensure updated PDSC is submitted to health department once drain covers are replaced.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(10) Provide test kit capable of measuring disinfectant level, cyanuric acid and total alkalinity. Some reagents expired. Replace. No permit action.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions. Main pool stair railing loose. Tighten per manufacturers instructions.

View this inspection on the county portal ›

Sep 11, 2024 6 demerits · 2 violations
Inspector comments: Conducted inspection with CPO Brad Head. Pool remains on A status and in good standing.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions. Main pool stair railing loose. Tighten per manufacturers instructions.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. EHS observed stuck flow meter. CPO corrected. No permit action.

View this inspection on the county portal ›

Feb 22, 2024 2 demerits · 1 violation
Inspector comments: Met with new CPO Brad Head. Tighten loose handrail. All other items in compliance.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions. Main pool stair railing loose. Tighten per manufacturers instructions.

View this inspection on the county portal ›

Aug 9, 2023 6 demerits · 1 violation
Inspector comments: On site visit with operator, Seth and EHS Noel Lamarre. Night swimming remains approved. Main drain covers expire 4/10/2025.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Lifesaving equipment should be conveniently located. Ring buoy throw rope tangled to point that would not be usable in the event of emergency. Ensure rope remains untangled to allow for ring buoy use in emergency. Operator corrected.

View this inspection on the county portal ›

Feb 22, 2023 4 demerits · 1 violation
Inspector comments: Inspection conducted with operator Seth Addo. Lighting verified during inspection with no changes to original diagram. Night swimming remains approved.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Observed weekend records missing main drain checks. All other records observed in compliance. No action taken.

View this inspection on the county portal ›

Aug 31, 2022 4 demerits · 1 violation
Inspector comments: OBSERVED THAT THE 1HP MOTOR WAS SWAPPED OUT FOR A NEW 1HP MOTOR. THERE IS AN ELECTRICAL PERMIT DOCUMENTED FOR THE CHANGE, BUT THE FINAL ELECTRICAL INSPECTION HAS NOT BEEN PERFORMED. THIS MUST BE DONE. IT IS RECOMMENDED THAT THE POOL BE CLOSED TO SWIMMING UNTIL THE ELECTRICAL FINAL INSPECTION IS PERFORMED. THE POOL WILL NOT RECEIVE NEW PERMIT FOR THE NEXT OPERATING SEASON IF THE ELECTRICAL FINAL INSPECTION IS NOT PERFORMED. OBSERVED THE POOL AND DECK LIGHTS OPERATING SO THAT NIGHT SWIMMING APPROVAL IS VERIFIED.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Observed some gaps in the log record. Keep all records properly. No permit action taken, records were largely kept correctly.

View this inspection on the county portal ›

Apr 1, 2022 0 demerits · 0 violations
Inspector comments: POOL WAS PREVIOUSLY APPROVED FOR NIGHT SWIMMING. OBSERVED LIGHTS TO BE OPERATIONAL FOR NIGHT SWIMMING. CPO AGREED TO EMAIL OF THE REPORT NO VIOLATIONS NOTED.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Aug 19, 2021 4 demerits · 1 violation
Inspector comments: OBSERVED LIGHTS TO BE OPERATIONAL FOR NIGHT SWIMMING. CPO AGREED TO EMAIL OF THE REPORT PLEASE CONTINUE TO FOLLOW ALL RELEVANT COVID REQUIREMENTS NO SIGNATURE DUE TO COVID PRECAUTIONS.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed pool furniture to be too close to the water edge (4 feet). Items were moved to at least 6 feet back.

View this inspection on the county portal ›

Feb 25, 2021 6 demerits · 1 violation
Inspector comments: “issuance of a permit by this department does not negate closure required by Executive Order No. 120, 138, 141, 147, or subsequent Orders in effect unless such Orders are rescinded or superseded by another applicable Order.” NO SIGNATURE WAS OBTAINED DUE TO COVID-19 SOCIAL DISTANCING RESPONSIBLE PARTY AGREED TO EMAIL OF REPORT.
#2 · Water quality: disinfectant residual provided by −6
Observed chlorine to be at 0.6ppm. -CDI corrected to 1.0ppm. .2535(4) Maintain chlorine at least 1.0 ppm.

View this inspection on the county portal ›

Oct 1, 2020 6 demerits · 2 violations
Inspector comments: “issuance of a permit by this department does not negate closure required by Executive Order No. 120, 138, 141, 147, or subsequent Orders in effect unless such Orders are rescinded or superseded by another applicable Order.” NO SIGNATURE WAS OBTAINED DUE TO COVID-19 SOCIAL DISTANCING POOL IS NOT APPROVED FOR NIGHT SWIMMING. IF NIGHT SWIMMING IS DESIRED, A NIGHT SWIMMING EVALUATION MUST BE PERFORMED. CONTACT C. ELMORE AT 704-507-6814 FOR THIS EVALUATION IF NIGHT SWIMMING IS DESIRED. Ensure that a Certified Pool Operator is does visit the pool every day the pool is open. This is a requirement.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
pH, chlorine, and main drains must be checked once a day when the pool is open. Total Alkalinity and Cyanuric Acid (if in use) must be checked once a week, 100ppm maximum for Cyanuric Acid. Observed gaps in pool log book records. Keep records properly. No Permit Action taken, most records were in order.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed stair rail to be loose. Fix the loose rail.

View this inspection on the county portal ›

Jun 30, 2020 0 demerits · 0 violations
Inspector comments: Observed no non-complaint conditions. Verified PDSC information. Raymond Watts present during inspection No signature due to COVID19 social distancing.

No violations were recorded for this inspection.

View this inspection on the county portal ›