‹ Back to search

4demerits

ADAMS PLACE CONDOMINIUMS

10105 REVOLUTION CT, Charlotte, NC 28262
Year-Round Swimming Pool · NC permit/State ID 2060530564
Latest result4 demerits
Last inspectedJul 9, 2026
Inspections on record12
On record sinceJun 4, 2020

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

01326 Jun 4, 2020: 6Jul 21, 2020: 26Apr 22, 2021: 20May 26, 2021: 6Aug 12, 2021: 16Apr 11, 2022: 24Dec 13, 2022: 20Mar 29, 2023: 26Oct 4, 2023: 14Jun 26, 2024: 8Oct 1, 2024: 4Jul 9, 2026: 4
Jun 4, 2020Lower is betterJul 9, 2026

Inspections & violations

Jul 9, 2026 4 demerits · 1 violation
Inspector comments: POOL HAS PASSED INSPECTION AND BEEN ISSUED PERMIT DECAL. POST PERMIT DECAL AT THE POOL. THE PAPER PERMIT SHOULD BE AVAILABLE WITHIN 1-3 BUSINESS DAYS ON THE HEALTH DEPARTMENT POOL WEBSITE. POOL IS NOT APPROVED FOR NIGHT SWIMMING. MAIN DRAINS EXPIRE 4/29/2030.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Fence is not to current specifications. Footholds are present. Fence horizontals are less than 45” (32”) apart. Fence was built prior to 2010. No permit action taken.

View this inspection on the county portal ›

Oct 1, 2024 4 demerits · 1 violation
Inspector comments: Inspection conducted with CPO Hector Villanueva. Main drains and equalizer line covers expire 5/6/2025 and 5/19/2025. Equalizer line cover at steps a dummy cover that will need to be abandoned per state guidelines when cover expires. Replace with new ANSI/APSP/ICC-16 approved drain covers and provide updated Pool Drain Suction Compliance form to our office for approval prior to drain cover expiration. Also have the option to abandon equalizer lines per state guidelines. Paint on pool floor bubbling and chipping. Prior to 2025 pool permit being issued, will need to repaint or replaster pool.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Mulch built up over time. Pre-2010 fence < 48" high throughout. Fence with footholds < 30". .2528 Pool fence shall be at least 48" in height measured from outside of barrier and with footholds no less than 30 inches for pre-2010 fencing.

View this inspection on the county portal ›

Jun 26, 2024 8 demerits · 3 violations
Inspector comments: Inspection conducted with CPO Hector Villanueva. Verified emergency phone working correctly. Items from previous inspection corrected. No label on pump. Verified Pentair Challenger pump with 1.5 HP motor. Main drains and equalizer line covers expire 5-6-2025, and 5-19-2025. Prior to expiration, replace with ANSI/APSP/ICC-16 approved drain covers and provide updated Pool Drain Suction Compliance form to MeckPools@MeckNC.gov for approval. For equalizer line covers also have the option of abandoning per state guidelines. Equalizer line at pool steps has been abandoned, dummy cover in place will need to be removed when it expires. Some offsets where deck meets coping. Maintain with no gaps or offsets > 1/2 inch. Permit issued No Night Swimming Paper permit will be posted on our website in 3-5 business days for your records.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Mulch built up over time. Pre-2010 fence < 48" high throughout. Fence with footholds < 30". .2528 Pool fence shall be at least 48" in height measured from outside of barrier and with footholds no less than 30 inches for pre-2010 fencing.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Fan off in chemical storage room. Tied to light switch. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room. - Corrected. Fan and light left on.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Observed no soap in restrooms. .2526(j) Provide soap and soap dispenser, no glass, at each sink. No toilet paper in men’s restrooms. .2526(l) Provide toilet paper on toilet paper dispensers in restrooms.

View this inspection on the county portal ›

Oct 4, 2023 14 demerits · 4 violations
Inspector comments: Inspection conducted with CPO Seth Pardon. New Kings III call box added. Old emergency phone and signage still on pool deck. Operator removed phone. Be sure to remove sign and call box as well. Will verify old equipment and signage has been removed on next visit. Failure to remove will result in permit suspension. Intent to suspend issued 5)
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Missing weekend checks. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity. - Intent to suspend item.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Most baskets full of leaves. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Corrected.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Fresh mulch added. Pre-2010 fence < 48" high throughout. Fence with footholds < 30". .2528 Pool fence shall be at least 48" in height measured from outside of barrier and with footholds no less than 30 inches for pre-2010 fencing.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Bag of chemicals on floor. .2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor. - Corrected. Leak in the pump room. .2533(d) Pump room floor shall be kept dry and free of standing water.

View this inspection on the county portal ›

Mar 29, 2023 26 demerits · 7 violations
Inspector comments: Inspection conducted with Michael Wells. NOTE* Skimmers turned off in the pump room. Even after turning the valve back on still no flow in the skimmers. Large amount of bubbles coming from the floor returns. Pump strainer basket lid opaque, not able to determine when it needs cleaned. Recommend cleaning or replacing. Shower nozzle creates a sharp stream. Recommend replacing with a conventional shower head. Exposed wiring by pump room door. Recommend replacing broken lid for electrical box. Intent to suspend issued. 5) 8) 24)
#5 · Water quality: daily written records of water quality and test kit kept on site −4
No total alkality or cyanuric acid readings for March. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections,and pool water maintenance activities. Provide weekly recordings for cyanuric acid and total alkalinity. - Intent to suspend item.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
No flow in the skimmers. .2518(k) The flow-through rate through any one skimmer shall be between 20 GPM and the maximum flow rated under NSF 50. - Intent to suspend item.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed ladder missing one endcap. .2521 Install ladders per manufacturer instructions.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Pre-2010 fence < 48" high in places. Fence with footholds < 30". .2528 Pool fence shall be at least 48" in height measured from outside of barrier and with footholds no less than 30 inches for pre-2010 fencing.
#22 · Premises: emergency telephone provided −6
Emergency phone not functioning. .2530(f) Emergency phone shall remain operable. - Corrected.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Pump basket not installed correctly and damaged, allowing leaves and debris into the impeller. Both spare baskets damaged as well. .2518(e) Provide a spare basket for pump. - Intent to suspend item. Pump does not seem to be working properly. No flow in the skimmers. .2518(b) The pool circulation system shall be sufficient to clarify and disinfect the entire volume of the pool four times in 24 hours. - Intent to suspend item. Flow meter reads 35 GPM, but is air locked. .2518(g) Keep flow meter operational. - Intent to suspend item.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Fan not functioning in the chemical storage room. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room.

View this inspection on the county portal ›

Dec 13, 2022 20 demerits · 6 violations
Inspector comments: Issued Intent to suspend for records and flow meter. Return visit will take place in 30 days. Please call James Bjorneboe at 704-507-6820 with any questions.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Observed. No daily written records for December. Keep daily records as required. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed 1 of 4 weirs missing. Replace. .2518(k) Replace missing weirs.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed ladder missing endcaps. Replace. .2521 Install ladders per manufacturer instructions.
#18 · Premises: lifeguards present or warning signs posted −4
“WARNING NO LIFEGUARD ON DUTY” sign not present. Corrected on site.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter stuck. Repair. .2518(g) Keep flow meter operational.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed bags of chemical on floor. Store paper bags of chemicals off of the floor. .2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up.

View this inspection on the county portal ›

Apr 11, 2022 24 demerits · 5 violations
Inspector comments: OBSERVED 9AM-9PM POOL HOURS SIGN. POOL IS NOT APPROVED FOR NIGHT SWIMMING. POOL MUST ONLY BE OPEN DAWN TO DUSK. IF NIGHT SWIMMING IS DESIRED, A NIGHT SWIMMING EVALUATION MUST BE PERFORMED. CONTACT C. ELMORE AT 704-507-6814 FOR THIS EVALUATION IF NIGHT SWIMMING IS DESIRED. CPO AGREED TO EMAIL OF REPORT.
#3 · Water quality: pool water pH −6
pH was at 7.1 on arrival. Corrected to 7.3 C.D.I.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed 1 weir missing out of 4 total. Replace the missing/broken skimmer. No permit action taken.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed ladder missing rubber bumper feet. Replace the rubber bumper feet.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed throw rope for ring buoy to be 39 feet when 36 feet is required. C.D.I. rope shortened to 36 feet.
#22 · Premises: emergency telephone provided −6
.2530(f) Emergency phone shall remain operable. Observed emergency phone to have too much interference on the line to be heard or understood by 911 dispatch. Pool closed as phone is not properly operable. Phone must function and have a working call-back number that is posted with local 911 service along with the proper address. Proper address and call-back number must be correct and on file with local 911. PERMIT SUSPENDED POOL CLOSED TO SWIMMING. Contact C. Elmore when correction is made. 704-507-6814.

View this inspection on the county portal ›

Aug 12, 2021 16 demerits · 4 violations
Inspector comments: Inspection conducted with Andy Bermudez. Due to COVID-19 precautions, inspection was not signed by the operator. No label observed on pump. Observed Pentair Challenger pump with 1 1/2HP motor. Offset between deck and coping. Maintain deck with no gaps or offsets > 1/2". Caulking around the pool deteriorating, recommend re-caulking before Winter. Intent to suspend issued 5)
#5 · Water quality: daily written records of water quality and test kit kept on site −4
No records for Sundays. Total alkalinity and cyanuric acid have both consistently been 80 ppm for the last 3 months. Ensure total alkalinity and cyanuric acid are checked with a test kit. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, and pool water maintenance. Provide weekly recordings for cyanuric acid and total alkalinity weekly. - Intent to suspend item.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
One weir damaged, hole in it. .2518(k) Provide functional weirs.
#22 · Premises: emergency telephone provided −6
New emergency phone no longer automatically dials 911, incorrect dialing instructions posted. .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. - Corrected.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Fan not functioning in the chemical storage room. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room.

View this inspection on the county portal ›

May 26, 2021 6 demerits · 1 violation
Inspector comments: Inspection conducted with Kendall Siddons and Andy Bermudez. Due to COVID-19 precautions, inspection was not signed by the operator. No label observed on pump. Observed Pentair Challenger pump with 1 1/2HP motor. Emergency phone with heavy static. Recommend checking the line. Pre-permit issues from previous inspection have been addressed. Permit issued with the following conditions: No Night Swimming Dummy equalizer line cover at pool steps. Line plugged per state guidelines. Will need to remove cover prior to expiration 5-19-2025. Paper permit will be on our website, Meckpools.Charmeck.org in 3-5 business days to print for your records.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Throw rope 40 feet. Pool measures 24 feet wide. .2530(a) Provide USCG approved ring buoy with 36 foot throw rope. Corrected.

View this inspection on the county portal ›

Apr 22, 2021 20 demerits · 5 violations
Inspector comments: Inspection conducted with Seth Pardon. Due to COVID-19 precautions, inspection was not signed by the operator. No label observed on pump. Observed Pentair Challenger pump with 1 1/2HP motor. Newly installed electronic gate latch. Ensure that latch operates on a battery backup or is designed to remain latched if there is a power outage. Offsets between coping and deck. Maintain deck so there are no gaps or offsets > 1/2". Caulking deteriorating along coping. Recommend re-caulking. Immediate suspension issued 22) Inspection did not pass. A $100 reinspection fee will need to be paid prior to scheduling a reinspection. This can be done by calling our main office (980-314-1620) and paying with a credit card.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
New electronic gate latch installed extends out 4", < 45" high creating a foothold. .2528(b) Gate horizontals and footholds shall not be located less than 45" in height. - Intent to suspend item.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Deck chair too close to pool edge. .2522(a) Provide 6 ft of clear walking space around the pool at all times. - Corrected.
#22 · Premises: emergency telephone provided −6
Unable to get emergency phone to pick up when called. Unable to reach 911. .2530(f) Pool telephone shall be capable of directly dialing 911 or another emergency notification system. - Immediate suspension item.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter stuck. .2518(g) Keep flow meter operational. - Intent to suspend item.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Fan not functioning in the chemical storage room. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room.

View this inspection on the county portal ›

Jul 21, 2020 26 demerits · 7 violations
Inspector comments: Inspection conducted with Adam House. Due to COVID-19 precautions, inspection was not signed by the operator. - Some green algae growing on pool walls. Maintain pool free of algae. - Handle on gate < 45" high, sticks out 2.5". Recommend moving handle above 45" or removing the handle. Facility plans on replacing with keyfob system. Ensure that there are no footholds < 45" and that keyfob system operates on a battery backup. - Caulking missing or damaged around coping. Recommend recaulking prior to this winter to avoid freeze damage. - Flow meter heavily faded, recommend replacing. - Emergency phone does not ring when called. Ensure that phone rings so that if a call is dropped 911 can call back. Will be back in 2 weeks to check on this. Failure to correct will result in permit action. - A8Rxxx equalizer line cover installed at steps missing riser ring. Install A112 approved cover per manufacturer's instructions or abandon per state guidelines. Will be back in 4 weeks to check on this. Failure to correct will result in permit action. “Executive Order No. 141 or subsequent Orders are in effect unless such Orders are rescinded or superseded by another applicable Order.” Intent to suspend issued Records Test kit
#3 · Water quality: pool water pH −6
pH 6.8. .2535(1) Maintain pH at 7.2 to 7.8. Corrected to 7.3.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Records spotty. Missing some weekends, some main drain checks, no cyanuric acid checks since 6/4. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, and pool water maintenance. Provide weekly recordings for cyanuric acid and total alkalinity weekly. - Intent to suspend item. Most pool chemicals have expired. .2535(10) Provide test kit capable of measuring disinfectant level, cyanuric acid and total alkalinity. - Intent to suspend item.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Ladder missing endcaps, extends > 6" into the pool. .2521 Install ladders per manufacturer instructions. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Throw rope 40 feet. .2530(a) Provide USCG approved ring buoy with 38 foot throw rope. Corrected.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Fence < 48" high in places. Fence with footholds < 30". .2528 Pool fence shall be at least 48" in height measured from outside of barrier and with footholds no less than 30 inches.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Fan not working in chemical storage room. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
No toilet paper in women's restroom. Toilet paper not on a holder in men's restroom. .2526(l) Provide toilet paper and dispensers in restrooms. Corrected.

View this inspection on the county portal ›

Jun 4, 2020 6 demerits · 2 violations
Inspector comments: Verified PDSC information. Seth present during inspection. No signature due to COVID19 social distancing requirements.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed cracked tiles on pool wall. Filled during inspection. .2537(14) Keep pool surface and pool floor free of debris and in good repair.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Observed no soap in restrooms. .2526(j) Provide soap and soap dispenser, no glass, at each sink.

View this inspection on the county portal ›

Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “ADAMS PLACE CONDOMINIUMS” or State ID 2060530564). Inspection type (routine vs. follow-up) is not published in the county's data.