8demerits
ELEVEN240
10655 TISBURY RD, Charlotte, NC 28216
Year-Round Swimming Pool · NC permit/State ID 2060530594
Latest result8 demerits
Last inspectedSep 18, 2026
Inspections on record14
On record sinceApr 1, 2021
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Apr 1, 2021Lower is betterSep 18, 2026
Inspections & violations
Sep 18, 2026 8 demerits · 2 violations
Inspector comments: POOL IS NOT APPROVED FOR NIGHT SWIMMING. POOL CANNOT BE OPEN AFTER SUNSET OR BEFORE SUNRISE.
MAIN DRAIN COVERS EXPIRE 9/1/2030
SALT IS NOT APPROVED AS PRIMARY CHLORINATION.
ENSURE THAT GLASS ITEMS ARE NOT BROUGHT INTO THE POOL ENCLOSURE.
2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable.
.2535(11) Provide weekly recordings for cyanuric acid and total alkalinity.
.2535 (11) The pool operator shall inspect the pool at least daily and maintain written records.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Missing 3 out of 5 weirs. .2518(k) Provide functional weirs. - Corrected.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing, self-latching. Observed 1 gate not self-latching. Corrected during the inspection.
May 13, 2026 10 demerits · 3 violations
Inspector comments: Inspection conducted with CPO Kenneth Booker.
Intent to suspend issued
5)
Failure to correct intent to suspend items before permit expires on 5/31/2026 will result in a suspension of the pool permit.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
No place on log sheet for main drain, total alkalinity, or cyanuric acid checks. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity. - Intent to suspend item.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
One weir installed upside down. .2518(k) Provide functional weirs. - Corrected.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Most soap dispensers are empty. .2526(j) Provide soap and soap dispenser, no glass, at each sink.
Sep 10, 2025 20 demerits · 5 violations
Inspector comments: Inspection conducted with CPO Chauncey Smith.
Chauncey is the new CPO for this pool. Updated CPO information.
Immediate suspension issued
15)
Re-inspection scheduled for tomorrow at 10:00 AM. Can contact Will Harrison (704) 507-6824 to reschedule if needed.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
Missing one eyeball fitting. .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Ring buoy with 42 foot throw rope. .2530(a) Provide US Coast Guard approved ring buoy with attached 46 foot throw rope at least 1/4 inch in diameter. - Immediate suspension item.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Gates by grills and pump room not self-closing and self-latching. .2528(a) Access gates shall swing away from the pool and be self-latching, self-closing. - Intent to suspend item.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Corner piece of coping by bench loose. .2537(3) There shall be no loose coping. - Intent to suspend item.
Tops of some of the skimmers sunken into the deck. .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. - Intent to suspend item.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Some chemicals stored in the pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. - Corrected.
Some chemicals and other items stored next to pool equipment. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
May 22, 2025 20 demerits · 5 violations
Inspector comments: Inspection conducted with CPO Jeremiah Gourevitch.
Jeremiah is the new CPO for the pool. Updated the files with new CPO information.
Paper permit will be on our website, https://eh.mecknc.gov/pools, in 3-5 business days for your records.
Permit sticker issued with the following conditions:
No Night Swimming
Salt is not approved as primary chlorination
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Missing one weir. .2518(k) Provide functional weirs. - Corrected.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
Missing one eyeball fitting. .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
New US Coast Guard Approved ring buoy with 60 foot throw rope. .2530(a) Provide US Coast Guard approved ring buoy with attached 46 foot throw rope at least 1/4 inch in diameter. - Corrected.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Gate by grills won’t open. .2528(a) Access gates shall swing away from the pool and be self-latching, self-closing. - Corrected.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Some chemicals stored in the pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. - Corrected.
Fan not working in chemical storage room. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room.
Aug 19, 2024 20 demerits · 5 violations
Inspector comments: Inspection conducted with CPO Kieth Stewart.
Some algae growing on tile grout. Ensure pool is maintained free of algae.
Flow meter for chlorinator corroded. Recommend replacing with a new flow meter.
Immediate suspension issued
2)
3)
Contact Will Harrison (704-507-6824) for re-inspection once issues have been corrected.
#2 · Water quality: disinfectant residual provided by −6
Cl at 0.3 ppm. Operator able to adjust up to 0.4 ppm. .2535(4) Maintain chlorine at least 1.0 ppm. - Immediate suspension item.
#3 · Water quality: pool water pH −6
PH 8.2. .2535(1) Maintain pH at 7.2 to 7.8. Operator able to adjust to 8.0. - Immediate suspension item.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Ladder loose. .2521 Install ladders per manufacturer instructions.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Gate by office not self-latching. Catches gate post. .2528(a) Access gates shall swing away from the pool and be self-latching, self-closing. - Intent to suspend item.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
No soap in men’s restroom. .2526(j) Provide soap and soap dispenser, no glass, at each sink.
May 9, 2024 26 demerits · 7 violations
Inspector comments: Inspection conducted with CPO Kieth Stewart.
Some items from 8/31/2023 inspection have not yet been corrected. Conducted full inspection.
Operator able to get salt system working, however facility is not permitted for salt as the primary chlorination system. Salt system is undersized for this pool.
Green algae growing on pool walls. Maintain pool free of algae.
Outer rope on ring buoy worn. Recommend replacing with a new US Coast Guard approved ring buoy and attached 46 foot throw rope at least 1/4 inch in diameter.
Facility has not yet renewed pool permit for 2024 pool season. Application and instructions have been emailed to the facility. Can also call our office (980-314-1620) with questions.
Immediate suspension still in place.
2)
5)
8)
23)
Will need to pay a $100 re-inspection fee by calling our office (980-314-1620) and paying with a credit card.
#2 · Water quality: disinfectant residual provided by −6
Cl at 0.6 ppm. .2535(4) Maintain chlorine at least 1.0 ppm. - Immediate suspension item.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
No weekend or cyanuric acid checks. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity. - Immediate suspension item.
Tested for cyanuric acid in the pool. None observed. .2535(3) Outdoor pools that use chlorine must be stabilized with cyanuric acid not to exceed 100 ppm. - Immediate suspension item.
Test kit expired. .2535(10) Provide test kit capable of measuring disinfectant level, cyanuric acid and total alkalinity. - Intent to suspend item.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
4 of 5 weirs missing or damaged. .2518(k) Provide functional weirs. - Immediate suspension item.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Ladder missing endcaps. .2521 Install ladders per manufacturer instructions.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Some sections of fencing < 48" due to layers of pine straw. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. - Intent to suspend item.
#23 · Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 −4
Ensure erosion chlorinator is working properly. Salt is not approved as primary chlorination. .2535(6) Provide NSF approved automatic chlorinator installed per manufacturer instructions. - Immediate suspension item.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
One stall in women’s restroom out of toilet paper. .2526(l) Provide toilet paper and dispensers in restrooms.
Jul 27, 2023 28 demerits · 7 violations
Inspector comments: Inspection conducted with CPO Douglas Hickman.
Immediate suspension issued
2)
Contact Will Harrison (704-507-6824) to schedule re-inspection once issues have been corrected.
#2 · Water quality: disinfectant residual provided by −6
Cl at 0.5 ppm. Operator turned up chlorinator but was unable to increase chlorine levels. .2535(4) Maintain chlorine at least 1.0 ppm. - Immediate suspension item.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Cyanuric Acid at 100 ppm for the last month in pool log book. Tested today at 0ppm. .2535(3) Outdoor pools that use chlorine must be stabilized with cyanuric acid not to exceed 100ppm. - Intent to suspend item.
PH 7.8. Every day for the month of July. .2535 (11) The pool operator shall inspect the pool at least daily and maintain written records using a test kit to check water chemistry. - Intent to suspend item.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Missing 2 of 5 weirs. .2518(k) Replace missing weirs. - Intent to suspend item.
Skimmer basket broken, pieces floating in skimmer. .2518(k) Replace missing or damaged skimmer basket. - Intent to suspend item.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Two of three gates not self-closing and self-latching. .2528(a) Access gates shall swing away from the pool and be self-latching, self-closing. - Intent to suspend item.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Hole in the deck where one deck drain cover came off. .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile.
#23 · Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 −4
Ensure chlorinator is working properly. No flow on flow meter for erosion feeder observed. Low salt warning light on salt cell observed. .2535(6) Provide NSF approved automatic chlorinator installed per manufacturer instructions. - Intent to suspend item.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Bad leak at filter, water running away from pump room drains and under the pump room wall. .2533(d) Pump room floor shall be kept dry and free of standing water.
Boxes of chemicals stored in the pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
Jun 7, 2023 2 demerits · 1 violation
Inspector comments: Pre-permit inspection conducted with CPO Douglas Hickmon and Tim, regional maintenance staff.
Emergency phone number posted inside phone box. Recommend adding emergency phone number to emergency phone signage. Number posted currently is the number for the office.
Permit issued
No Night Swimming
Paper permit will be available on our website https://health.mecknc.gov/envhealth/pools in 3-5 business days for your records.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Leak at filter. .2533(d) Pump room floor shall be kept dry and free of standing water.
Jun 5, 2023 16 demerits · 4 violations
Inspector comments: Pre-permit inspection conducted with CPO Douglas Hickmon and Tim, regional maintenance staff.
Gate by grill area sticks. Ensure gate is self-closing and self-latching and operates properly. - Corrected.
Pre-permit inspection did not pass
1)
There is a $100 re-inspection fee that must be paid prior to conducting a re-inspection by calling our office (980-314-1620) and paying with a credit card.
Tentatively scheduled re-inspection for tomorrow at 9:00 AM.
#1 · Water quality: water clear enough to clearly see bottom of pool and pool drain −6
Operator added chemicals to adjust pH. Water became too cloudy to see main drains. .2535(2) Main drains must be clearly visible from the pool deck. - Pre-permit item.
#3 · Water quality: pool water pH −6
PH 6.9. .2535(1) Maintain pH at 7.2 to 7.8. - Corrected to 7.2.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Ladder loose. .2521 Install ladders per manufacturer instructions. - Corrected.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Leak at filter. .2533(d) Pump room floor shall be kept dry and free of standing water.
Jun 1, 2023 40 demerits · 10 violations
Inspector comments: Inspection conducted with CPO Douglas Hickmon. Updated CDP with his CPO information.
Gate by grill area sticks. Ensure gate is self-closing and self-latching and operates properly.
Pre-permit inspection did not pass. Scheduled re-inspection for 6/5 at 11:30 AM. There is a $100 re-inspection fee that must be paid prior to conducting a re-inspection by calling our office (980-314-1620) and paying with a credit card.
Pre-permit items
2)
3)
5)
7)
8)
16)
18)
#2 · Water quality: disinfectant residual provided by −6
Two chlorine tabs in the skimmer closest to the pump room. G.S. 130A-2(3) Chlorine added directly to swimming pool. Chlorination must occur through chlorinator. Eliminate direct hazard to public. - Pre-permit item.
#3 · Water quality: pool water pH −6
PH 8.2. .2535(1) Maintain pH at 7.2 to 7.8. - Pre-permit item.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
No recent Total Alkalinity readings. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, and pool water maintenance. Provide weekly recordings for cyanuric acid and total alkalinity weekly. - Pre-permit item.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Pool floor dirty, some algae growing in the corners on the sunshelf. .2537(14) Keep pool surface and pool floor free of debris. - pre-permit item.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Missing one weir. .2518(k) Replace missing weirs. - Pre-permit item.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Ladder loose. .2521 Install ladders per manufacturer instructions.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Most of the fencing < 48" due to layers of pine straw. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. - Pre-permit item.
#18 · Premises: lifeguards present or warning signs posted −4
Some safety signage missing. .2530(c) Provide "Children should not use the swimming pool without adult supervision." in 1" lettering. - Pre-permit item.
Some safety signage missing. .2530(c) Provide "Adults should not swim alone." in 1" lettering. - Pre-permit item.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Digital flow meter not functioning. .2518(g) Keep flow meter operational. - Corrected.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Fan in chemical storage room not functioning. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room.
A few different leaks in the pump room. .2533(d) Pump room floor shall be kept dry and free of standing water.
Some chemicals stored in the pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
Aug 24, 2022 24 demerits · 5 violations
Inspector comments: Inspection conducted with Julius Parker.
Posted pool hours are 9 AM - 9 PM. This is after dark for part of the year. Pool is not permitted for night swimming, failed night lighting inspection. Will need to change posted pool hours to reflect that pool is not open after dark.
Immediate suspension issued
3)
15)
Contact Will Harrison (704-507-6824) to schedule re-inspection when issues have been corrected.
#3 · Water quality: pool water pH −6
PH 7.9. .2535(1) Maintain pH at 7.2 to 7.8. - Immediate suspension item.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Cyanuric Acid at 100 or 100+ for the last month in pool log book. Tested today at well over 100 ppm. .2535 (4) Lower and maintain cyanuric acid at or below 100 ppm. - Intent to suspend item.
No documentation that facility has a CPO on staff to check the pool every day. .2537(c) Pool owner shall provide for the operation and maintenance of the pool by a trained pool operator. - Intent to suspend item.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Body hook with only one screw. .2530(a) Provide at least 12 ft. long pole with body hook securely attached. - Immediate suspension item.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Gate by pump room not always self-latching, sometimes sticks. .2528(a) Access gates shall swing away from the pool and be self-latching, self-closing. - Intent to suspend item.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Digital flow meter not functioning. .2518(g) Keep flow meter operational. - Intent to suspend item.
Mar 15, 2022 24 demerits · 6 violations
Inspector comments: Inspection conducted with Darius Wilson. Due to COVID-19 precautions, inspection not signed by the operator.
Intent to suspend issued
5)
8)
#5 · Water quality: daily written records of water quality and test kit kept on site −4
No recent Total Alkalinity or Cyanuric Acid readings. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, and pool water maintenance. Provide weekly recordings for cyanuric acid and total alkalinity weekly. - Intent to suspend item.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Missing 4 of 5 weirs. .2518(k) Replace missing weirs. - Intent to suspend item.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Ladder loose. .2521 Install ladders per manufacturer instructions.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Throw rope 30 feet long. .2530(a) Provide USCG approved ring buoy with attached 46 foot throw rope at least 1/4" in diameter. - Corrected.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Some sections of fencing < 48" due to layers of pine straw. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. - Corrected.
#18 · Premises: lifeguards present or warning signs posted −4
Some safety signage missing. .2530(c) Provide "Children should not use the swimming pool without adult supervision." in 1" lettering. - Corrected.
Some safety signage missing. .2530(c) Provide "Adults should not swim alone." in 1" lettering. - Corrected.
Apr 29, 2021 4 demerits · 1 violation
Inspector comments: Inspection conducted with Chris Garcia. Due to COVID-19 precautions, inspection was not signed by the CPO.
Ensure that all ladders and handrails are rated for saltwater. Pool using salt for secondary chlorination.
Posted pool hours are 9 AM to 9PM. Lighting inspection scheduled for 6AM on 5/3 to verify that lighting is sufficient to allow for night swimming.
Recommend posting COVID-19 safety signage as required by North Carolina Executive Orders.
Facility plans to order new custom emergency phone and pool rules signage. Ensure new signage meets requirements.
Permit issued
No Night Swimming
Paper permit will be on our website in 3-5 business days. Go to our website, Meckpools.Charmeck.org to print a copy for your records.
“Executive Order No. 141 or subsequent Orders are in effect unless such Orders are rescinded or superseded by another applicable Order.”
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Fencing along road with one picket not fully secured, gap greater than 4 inches. .2528(a) Provide no openings in fence and/or gate greater than 4"x4". - Corrected.
Apr 1, 2021 32 demerits · 8 violations
Inspector comments: Inspection conducted with Chris Garcia. Due to COVID-19 precautions, inspection was not signed by the CPO.
Recommend providing a chemical safety placard on the chemical storage room door.
Ensure that all ladders and handrails are rated for saltwater. Pool using salt for secondary chlorination.
Posted pool hours are 9 AM to 9PM. Either change pool hours to reflect that pool closes at dusk or schedule a lighting inspection to ensure pool and required deck space has sufficient lighting.
Recommend posting COVID-19 safety signage as required by North Carolina Executive Orders.
Inspection did not pass. All items noted as Pre-permit item will need to be corrected before a permit can be issued.
A $100 reinspection fee will need to be paid prior to scheduling a reinspection. This can be done by calling our office (980-314-1620) and paying with a credit card.
“Executive Order No. 141 or subsequent Orders are in effect unless such Orders are rescinded or superseded by another applicable Order.”
#5 · Water quality: daily written records of water quality and test kit kept on site −4
No recent records. Last month's records missing TA, CA, and Main Drain checks. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, and pool water maintenance. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Corrected. Operator took chemical readings today.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
One weir floating in the skimmer. .2518(k) Replace missing weirs. Corrected by operator.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Fencing along road with one picket not fully secured, gap greater than 4 inches. .2528(a) Provide no openings in fence and/or gate greater than 4"x4". - Pre-permit item.
Sections of fencing along road with very little pine straw. Gaps as much as 4 inches under the fence. .2528(a) Maintain 2" or less under fence and/or gate (post-May 2010). - Pre-permit item.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Some deck chairs and set of table and chairs too close to pool edge. .2522(a) Provide 6 ft of clear walking space around the pool at all times. - Pre-permit item.
#18 · Premises: lifeguards present or warning signs posted −4
Some safety signage missing. .2530(c) Provide "Children should not use the swimming pool without adult supervision." in 1" lettering. - Pre-permit item.
Some safety signage missing. .2530(c) Provide "Adults should not swim alone." in 1" lettering. - Pre-permit item.
#22 · Premises: emergency telephone provided −6
Phone number posted is for the main office, not the number for the emergency phone or what 911 has. 911 does not have the correct address for the pool. .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. - Pre-permit item.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Spare pump basket not observed. .2518(e) Provide a spare basket for filtration pump. - Pre-permit item.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Fan in pump room not functioning. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room. - Pre-permit item.
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “ELEVEN240” or State ID 2060530594). Inspection type (routine vs. follow-up) is not published in the county's data.