Score history

01428 Jul 9, 2021: 0Feb 22, 2022: 28Sep 28, 2022: 10Feb 28, 2023: 18Aug 2, 2023: 4Apr 19, 2024: 0Jul 17, 2024: 8Jan 29, 2025: 22Aug 27, 2025: 18Mar 10, 2026: 14Jul 20, 2026: 6
Jul 9, 2021Lower is betterJul 20, 2026

Inspections & violations

Jul 20, 2026 6 demerits · 2 violations
Inspector comments: Conducted inspection with regional manager Andre. Pool remains on A status and in good standing. NOTES: 1) Heater and salt system not approved. Permits were never finaled. Contact EHS if either are in use. 2) POOL IS NOT APPROVED OR SALT AS PRIMARY CHLORINATION. Const. Date: 7/7/2021 Rope Length: 50' Night Swim?: N
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Some pool furniture within 6’ of pool. .2522(a) Provide 6 ft of clear walking space around the pool at all times. Operator moved furniture and corrected. No permit action.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
.2526(h) Shower(s) shall be provided. Shower not operational at time of inspection.

View this inspection on the county portal ›

Mar 10, 2026 14 demerits · 4 violations
Inspector comments: Note: Main drains expire 06/2026. Failure to replace and submit PDSC form/paperwork for approval PRIOR to expiration will warrant permit action. Submit to pdsc@mecknc.gov Salt not approved as primary chlorination. Heater not approved, must remain off. If either is to be used, contact Health Dept for approval and pull permits prior to turning on. Pool and wading pool have not paid for next permitting season. Contact mainline at 980-314-1620 for payments and applications can be submitted to meckpools@mecknc.gov Contact Marie Daley at 704-507-6806 for operating permit inquires and updates Inspection with Mike Campbell
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Rope too long for buoy at time of inspection. .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Operator cut rope to 50’ and corrected.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Some pool furniture within 6’ of pool. .2522(a) Provide 6 ft of clear walking space around the pool at all times. Moved furniture and corrected.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
One bag of dry chemicals on floor. .2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
Shower broken, turned off. .2526(h) Shower(s) shall be provided.

View this inspection on the county portal ›

Aug 27, 2025 18 demerits · 5 violations
Inspector comments: Note: Coping starting to crack at edge of sun shelf. Monitor and repair if worsens. Main drains expire 6/25/2026. Replace and submit updated PDSC form PRIOR to expiration for approval to avoid permit action. Updated CPO to Anthony Demaio Heater and salt not approved. Heater off and no night swimming.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Weekly total alkalinity and cyanuric acid not recorded. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Operator checked all required tests and recorded. Corrected.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Debris in skimmers at time of inspection. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Operator emptied and corrected.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
One gate not latching at time of inspection. .2537(b) All gates and doors shall be self-closing, self-latching. Operator adjusted and corrected.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Some pool furniture within 6’ of pool. .2522(a) Provide 6 ft of clear walking space around the pool at all times. Moved furniture and corrected.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
Shower broken, turned off. .2526(h) Shower(s) shall be provided.

View this inspection on the county portal ›

Jan 29, 2025 22 demerits · 5 violations
Inspector comments: No Night Swimming. Salt not approved as primary chlorination. Heater not approved. Updated CPO to Omar Hernandez
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Last few days of records missing. Weekly total alkalinity and cyanuric acid not recorded. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Operator checked all required tests and recorded. Corrected.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Debris in skimmers at time of inspection. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Operator emptied and corrected.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Rope around buoy in disrepair at time of inspection. .2530(a) Provide USCG approved ring buoy. A rescue tube with lifeguard may be substituted for ring buoy.Operator replaced buoy with 50’ rope and corrected.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
One gate not latching at time of inspection. .2537(b) All gates and doors shall be self-closing, self-latching. Operator adjusted and corrected.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Some pool furniture within 6’ of pool. .2522(a) Provide 6 ft of clear walking space around the pool at all times. Moved furniture and corrected.

View this inspection on the county portal ›

Jul 17, 2024 8 demerits · 2 violations
Inspector comments: Pool is not currently using salt system or heater and does not intend to use either. CPO, Jason Rivera is aware that there is not a permit for salt system or heater and neither can be used until permitted. NO NIGHT SWIMMING.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Debris in skimmers at time of inspection. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Operator emptied and corrected.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
One gate not latching at time of inspection. .2537(b) All gates and doors shall be self-closing, self-latching. Operator adjusted and corrected.

View this inspection on the county portal ›

Apr 19, 2024 0 demerits · 0 violations
Inspector comments: NO VIOLATIONS NOTED DURING INSPECTION

No violations were recorded for this inspection.

View this inspection on the county portal ›

Aug 2, 2023 4 demerits · 2 violations
Inspector comments: One gate not operable, due to lightning incident. Gate is currently zip tied together, note operable. Recommended more durable security for keeping gate inoperable. Not able to open at time of inspection, so no cation needed at this time. Advised this is not permanent solution. Small crack at sun shelf coping. Monitor and repair if this worsens. Not 1/2” or violation at this time. Salt not approved as primary coronation and heater not approved. No night swimming.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
One jug of muratic acid over dry chemicals. .2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up. Moved jug and corrected.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
No toilet paper in restrooms. .2526(l) Provide toilet paper and dispensers in restrooms. Operator placed toilet paper in restrooms. Corrected.

View this inspection on the county portal ›

Feb 28, 2023 18 demerits · 5 violations
Inspector comments: 30 day intent to suspend (ITS) issued for records and gap under fencing greater than 2 inches. Contact Marie Daley at 704-507-6806 when in compliance to lift ITS. Inspection Omi Martinez and Jimmy Legree Salt not approved as primary chlorination. No Night Swimming.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Daily records missing some days and maintenance not recorded. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. *Permit items
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Buoy and body hook behind chair and rope tangled, 60’. Keep accessible. Operator moved table and untangled rope, cut to 50’ and corrected. .2530(a) Lifesaving equipment should be conveniently located. .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Gaps greater than 2" under pool fence from wash out of mulch. .2528(a) Maintain 2" or less under fence and/or gate (post-May 2010). *Permit item
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Bucket of chemicals in pump room at time of inspection. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. Op[erator moved and corrected.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
No soap in restroom. .2526(j) Provide soap and soap dispenser, no glass, at each sink.

View this inspection on the county portal ›

Sep 28, 2022 10 demerits · 2 violations
Inspector comments: Salt and heater not approved. No Night swimming Inspection with Kinte Clark.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Missing weekly TA and CYA on records. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Operator checked and recorded. Corrected.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Buoy behind chair and table and rope tangled. Keep accessible. Operator moved table and untangled rope, corrected. .2530(a) Lifesaving equipment should be conveniently located. Rope starting to fray, advised new rope before it worsens prior to next inspection.

View this inspection on the county portal ›

Feb 22, 2022 28 demerits · 8 violations
Inspector comments: 30 Day Intent to Suspend (ITS) for gaps under fencing greater than 2", buoy beckets and records. Contact Marie Daley at 704-507-6806 when in compliance to lift ITS. Changed to "W" ITS. Pool voluntarily closed, advised signage must be posted at ALL bather entrances. 22) Kings III connects to 911. 911 operator stated the address should be Charlotte, not Pineville for dispatching and another address is listed besides address for pool. In case of emergency, services will be provided but potentially delayed due to this error. Advised manager and operator to reach out to all parties to ensure accuracy of location for emergency. Will verify at return visit. .2530(a) Emergency notification systems must provide 24 hr monitoring, be capable of routing calls to 911, and be able to electronically transfer Automatic Number and Locator Identification for the phone. Operator updated to Kinte Clark, CPO expires 6/13/23. Permit Restriction: Pool Is Not Approved For Salt As Primary Chlorination. Salt Cells Must Remain Inoperable Until Approved By The Department. Handrails Installed Are Not Marine Grade. Heater Is Not Approved By Code Enforcement And Restricted From Use Until Approved. No Night Swimming Fencing removed from wading pool, see visit under ID 540014 for more information. Work done must be inspected by Health Dept Inspection with Kinte Clark No signature due to COVID
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Records not being kept at time if inspection. Operator stated pool is closed, but signage not posted at all entrances. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. *Permit item
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Debris in skimmers at time of inspection. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Operator emptied and corrected.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Body hook behind chairs and tables, not easily accessible. Keep accessible. Operator moved table and corrected. .2530(a) Lifesaving equipment should be conveniently located. Becketts detached from buoy, but still secured to buoy. This voids USCG approval. *permit item. Allowing 30 Days for new buoy since pool is now voluntarily closed and buoy is still usable.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Gaps greater than 2" under pool fence from wash out of mulch. .2528(a) Maintain 2" or less under fence and/or gate (post-May 2010). *Permit item
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Chair with tables within 6' of pool at time of inspection. .2522(a) Provide 6 ft of clear walking space around the pool at all times. Operator moved and corrected.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Items within 3' of piping in equipment room. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
No showers at time of inspection. Shower being installed, not complete. .2526(h) Shower(s) shall be provided.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
No soap in restroom. .2526(j) Provide soap and soap dispenser, no glass, at each sink.

View this inspection on the county portal ›

Jul 9, 2021 0 demerits · 0 violations
Inspector comments: Observed gate latch with greater than 30 second delay on magnet. Reduced during inspection to less than 10 seconds. Davie Nuno present during inspection. No violations noted.

No violations were recorded for this inspection.

View this inspection on the county portal ›