4demerits
FAIRWAYS AT PIPER GLEN
6200 BIRKDALE VALLEY DR, Charlotte, NC 28277
Year-Round Swimming Pool · NC permit/State ID 2060530647
Latest result4 demerits
Last inspectedJul 28, 2026
Inspections on record5
On record sinceApr 29, 2022
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Apr 29, 2022Lower is betterJul 28, 2026
Inspections & violations
Jul 28, 2026 4 demerits · 1 violation
Inspector comments: Conducted inspection with property manager Corey. Pre 2010 fencing. Pool remains in good standing and on A status.
Permit Restriction: FlowVis flow meter must remain operable. Flow required from 223 gpm not exceed 500 gpm due to drain cover flow restriction. Suction Hazard. Possible IFPR app needed for fencing - will be moved to eliminate fitness room access 2026
Const. Date: 5/1/1995
Rope Length: 48'
Night Swim?: N
#21 · Premises: pool and deck lighting provided at pools that operate at night −4
.2537(9) Underwater light niches shall be maintained or covered so not to present a hazard.
Underwater light coming out of niche area. Operator pushed light back in and will ensure screws are tightened. No permit action.
May 20, 2026 6 demerits · 1 violation
Inspector comments: Inspection completed with Juan Miranda, Corey Gallian, and Dan Duncan present.
Permit conditions- FlowVis flow meter must remain operable. Flow required from 223 GPM not to exceed 500 GPM due to drain cover flow restriction. Suction hazard.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
Observed equalizer cap covers missing inside skimmers. Equalizer lines were capped on inner pool wall so no suction hazard present. Correct within 1 week or a 30 day intent to suspend will be issued on the permit.
May 24, 2023 6 demerits · 2 violations
Inspector comments: Issued permit. No Night Swimming.
“A” Open for Business
Main drains expire April 2024. Replace and send in updated PDSC for approval prior to expiration to avoid permit suspension.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing, self-latching. Observed gate onto pool deck not latching at time of inspection. Operator corrected to self-close, self-latch. Corrected.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Chemicals stored in pump room. Original construction. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
Dec 8, 2022 18 demerits · 5 violations
Inspector comments: Inspection completed with Scott Sandman present.
Intent to suspend issued for the following items:
1. Skimmers posing trip hazard due to settling; skimmers are below brick inlay approximately 1 inch.
2. Pool light closest to leasing office is offset from light niche.
3. Inadequate record keeping. Ensure chlorine, main drains, and pH are checked daily. Total alkalinity and cyanuric acid should be checked and recorded weekly.
Observed throw rope and ring buoy beginning to deteriorate. Repair within 30 days or pool permit may be suspended.
Correct these items by 1/7/2023. Contact Eli Freese at 704.621.2298 with questions.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Observed no record keeping for month of December and minimal records for month of November. Intent to suspend issued.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed 1 ladder without rubber end caps.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
.2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. Observed 1 missing return fitting. Observed light offset from light niche. Repair so light is seated properly inside fitting. Intent to suspend issued for light fixture.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. Observed areas of 1 inch offset around 2 skimmer baskets due to settling. Repair so no trip hazard exists. Intent to suspend issued.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(e) Provide a spare basket for pump. Observed no spare pump basket.
Apr 29, 2022 14 demerits · 3 violations
Inspector comments: Inspection completed with Juan Miranda present.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing, self-latching. Observed door leading from gym onto pool deck not self-latching.
#18 · Premises: lifeguards present or warning signs posted −4
.2530(c) All pool signage shall be visible upon entrance to the pool and permanently affixed. Observed warning signs not visible from all areas of pool deck. CDI- additional signs were purchased and mounted.
#22 · Premises: emergency telephone provided −6
.2530(f) Provide signage with location of emergency phone if not visible from all areas inside pool enclosure. Observed pool phone not visible from all entries with inadequate signs. CDI- additional signage posted.
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “FAIRWAYS AT PIPER GLEN” or State ID 2060530647). Inspection type (routine vs. follow-up) is not published in the county's data.